| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹43.6 LAccepted-AOC | L1 | Accepted-AOC being L1 | |
| 2 | L2₹44.3 L+₹46,612 (1.06%)Rejected-Finance SITE NO 29 30 1ST CROSS NAGAPPA REDDY LAYOUT KAGGADASAPURA CV RAMAN NAGAR PO BANGALORE 560 093 | BANGALORE | BANGALORE | KARNATAKA | 560093 | L2 | Rejected-Finance Rejected being L2 | |
| 3 | L3₹44.4 L+₹53,124.50 (1.21%)Rejected-Finance 606 80 FEET ROAD 7TH BLOCK 2ND PHASE BANASHANKARI 3RD STAGE BANGALORE 560 085 | BANGALORE | BANGALORE | KARNATAKA | 560085 | L3 | Rejected-Finance Rejected being L3 | |
| 4 | L4₹45.3 L+₹1.4 L (3.17%)Rejected-Finance NO 45 5TH CROSS MALLAPPA LAYOUT BABUSAPALYA KALYAN NAGAR BANGALORE 560043 | BENGALURU URBAN | KARNATAKA | 560043 | L4 | Rejected-Finance Rejected being L4 | |
| 5 | L5₹48.2 L+₹4.3 L (9.84%)Rejected-Finance | L5 | Rejected-Finance Rejected being L5 |
Tender Value
₹47.7 L
EMD Value
₹95,400
Closing Date
31 Oct 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE I RD East Bangalore
GE I RD East Bangalore 93
UPGRADATION OF BUILDING NO P162 FOR TURBOCHARGER PROJECT OFFICE AT GTRE BANGALORE
2022_MES_555761_1
8308
Open Tender
Civil Works
Item Rate
270 days
GE I RD East Bangalore
D a (i) b (i)
8 documents required · 8 mandatory
₹500
Yes
GE I R AND D East Bangalore
₹95,400
Yes
28 Dec 2022
3 Oct 2022
2 Nov 2022
4 Oct 2022
31 Oct 2022
19 Oct 2022
5 Oct 2022 - 15 Oct 2022
Amount
Demolition of cement concrete of any description and in any position not otherwise specifically provided for complete
M&L 100 mm thick cement concrete 1:2:4, type B-1 (using 20mm graded crushed stone aggregate) finished even and smooth, using extra cement as in floors complete all as specified.
Dismantling floor, hearth or wall tiling including cement mortar bedding (not backing) removing serviceable tiles to store and rubbish off the premises.
Meterial and labour for screed bed 15mm thick in CM 1:3 finished fair and even on cement/ brick surface in sunken slabs by using water proofing compound as per manufacture's instructions. Note: Supply only water proofing compound will measured seperately.
Supply only Intergal waterproofing compound.
Material and labour for applying evenly a tack coat of industrial bitumen 85/25@ 1.20Kg /sqm on plastered suefaces over a coat of primer complete all as specified and as directed
Material and labour for PCC 1:5:10, type E-2 (using 40mm graded stone aggregate) as in sunken slabs filing complete all as specified and as directed
M&L for PCC 1:2:4 type B1, 25mm thick (using 20mm graded stone aggregate) as in flooring/ paving finishing rough to receive cement tiles complete all as specified and as directed
M&L Non - skid ceramic tiles 7 to 8 mm thick ( square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sq, in floors etc. set and jointed in neat cement slurry and pointed in white or colored cement to match including 15mm thick screed bed in cm 1:6 complete all as specified and as directed
Material and labour for jointless glazed coloured ceramic tiles in vertical surfaces for wall tiles of size 450 x 300 x 7 mm thick as in dados, set and jointed in neat cement slurry and pointed in coloured cement to match coloured tiles with joint free including 10mm thick screed bed in cm 1:4 complete all as specified and as directed
S & F in repairs Vitreous China wash down water closet pan (pedestal pattern), white or colour (excluding fixing bolts, flushing cistern and flush pipe including connection to trap and to flushing pipe anti syphonage pipe ect complete including making good to floor complete all as specified and as directed. Make :CERA
Supply only plastic water closet seat, white closed pattern with flat bottom and cover and mild steel chromium plated or aluminised highing device. Make : CERA
S & F in repairs Vitreous china wash basin (Countersunk / top )angle back (Rectangle / Oval type ) , size 560x460mm white excluding taps waste chain and plug and porcelain stopper including cutting for and pinning in ends of brakets or eracting stand, waste pipe complete all as specified and as directed Make : CERA
M&L Granite (of any type) work 20 mm thick ( table rubbed and polished) in steps, jambs, pillars, windowcills, cooking platforms and like in including cement mortar (1:4) pointing in white cement (1:2) using marble dust with admixture of pigment to match including 15mm thick screed bed in CM 1:4 complete all as specified and as directed
S&F in repairs pillar taps, cast copper alloy with capstan heads chromium plated screwed down high presuure with or without lettered Hot or cold with long screwed shanks and fly nuts screwed for iron pipe and fixed complete all as specified and as directed
Supply and fix in repairs PVC valveless, symphonic action type, flushing cisten low level, white with inlet ball valve float and valve flaot and handle including brackets 10 ltrs capacity Make : CERA
Supply and fix flush pipe of polyethylene of high density of PVC 32 mm for low level cistern complete all as specified and as directed
Supply and fix in repairs brass chromium plated bottle traps for wash basins with inlet and outlet screwed for pipe or connections including necessary packing union cap and fixed 32mm complete all as specified and as directed
Supply and fix PVC connection 15mm size with PTMT nuts of length 600mm complete
Supply and fix in repairs stop valves, cast copper alloy, screwed down, high pressure with crutch or butter fly handle screwed both ends for iron pipe, fancy type chromium plated, 15mm size complete all as specified and as directed
Taking up or down steel tubing and connection 15mm dia
Taking up or down steel tubing and connection 20mm dia
Supply and fix tubes medium grade, galvanaized, with all fittings and fixed complete to walls and ceilling or laid in floors 15mm bore complete all as specified and as directed
Supply and fix tubes medium grade, galvanaized, with all fittings and fixed complete to walls and ceilling or laid in floors 205mm bore complete all as specified and as directed
Supply and fix PVC (SWR) floor trap 125/110 mm setting and jointing with solvant cement fixed complete.
Taking down PVC (SWR) pipes any dia .
Supply and fix PVC (SWR) pipes single socketed 110mm bore laid in floor trenches /wall complete all as specified and as directed
Supply and fix UPVC (SWR) pipes single socketed 75mm bore laid in floor trenches /wall complete all as specified and as directed
Supply and fix in repairs bib taps, fancy type, chromium plated with crutch or butter fly handle screwed both iron pipe or for brass ferrule and fixed 15mm size complete all as specified and as directed
Supply and fix health faucet(ABS BODY) mild steel chromium plated suitable for 15mm dia pipe with 1.25metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified
Supply and fix towel ring of PTMT fixed with and including chromiumeplated brass screws and wooden/plastic cleats.(Minimum weight 90 gms)
Supply and fix PTMT 450mm towel rail fixed with and including chromium plated brass screw wooden/plastic cleats.
Dismantling of water tanks and removing to store 1000 ltrs.
S&F for rotational moulded polyethylene water storage tanks 1000 ltrs (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR part I
M&L for surface excavation n.exc (not exceeding )30cm deep and averaging 15cm deep and getting out hard/dense soil
M&L for hardcore of 75mm thick of gauge n.exc 63 mm deposited, spread and levelled in layers n exc. 15cm thick , watered and rolled/rammed to a true surface complete all as specified and as directed
M & L for PCC 1:3:6 type C2 (using 40mm graded stone aggregate) as in plinth protection 75 mm thick finished even and fair all as specified Note :The plinth protection shall belaid in panels and length of the each panel shall not be more than 2.00 metre all as directed. 6mm joints filled with 85/25 grade bitumen and sand (1:3 ratio) shall be provided. No deduction for joints shall be made while making payment against the item.
M&L for PCC 75mm 1:3:6 type C2 (using 40mm graded stone aggregate) as in sub base complete all as specified and as directed
M&L 75mm thick, cement concrete 1:2:4 type B-1, (using 20mm graded crushed stone aggregate) finished even & smooth, using extra cement, as in floors complete all as specified and as directed
Dismantling stuctural steel work including doors, gate,steel railing etc.
M&L for stainless steel hand railing of required size, fixed to sides of platform/ path/ stairways etc of grade 304 with 50mm dia top rail 40mm dia vertical and runs of 20mmdia horizontal rails including suitable size steel bolt/ fastners/ fitting etc complete all as specified and directed.
M&L for steel rolling shutter in repairs with motor operated (motor taken in the E/M Schedule) thickness of lath in 1.0mm including top cover, anchoring rod,hasp and staple and one shop coat of primer erected in position as directed by Engr-incharge complete.
Supply and fixing steel collapsible steel gates, top hung, consisting of channel pickets, pivoted flat bars, top and bottom runners brasshandle etc, as specified,errected in postion and securing runners with hold fasts and brackets, complete by Engr-in-charge.
M&L Prepration of new surface of any description, over 10cm in width or girth, not otherwise discribed, two coat synthetic enamel paint over a coat of red oxide primer on iron surface complete all as specified and as directed
M&L Preparation of old painted wall surfaces by complete removal of existing paint and applying two coats of synthetic enamel paint over a coat of primer complete all as specified ans as directed
Grinding & Polishing of existing mosaic flooring removing thin layer of stone flooring using good quality of grits in a single disc machine removing tough stains and scratches from the floor after cleaning apply good quality mirror polish complete all as specified and as directed
M&L for 2mm thick epoxy based floor topping after priming the surface with solvent based epoxy resin primer designed for maximum absorption & adhesions per manufactures specification including preparation of floor by wire brushing or light grit blasting to remove laitance, dust & cleaning the same to achieve mechanical key between floor and coating system & applying epoxy putty/mortar mixed with suitable filler to cover the worm out areas all as specified & directed by Engineer-in-charge. Providing and applying 2mm thick self leveling epoxy flooring 4 component self leveling pigmented epoxy floor top coating which consists of surface preparation including removal of contaminants like dust, laitance, oil, paint and preparing the surface by grinding or shaliprime 2 E @0.2-0.25kg/m^2 & top coated with 2mm thick 4 componentet pigmented self leveling topping material shalifloor SL TC 4E @ 3.2Kg/m having shore hardness of 70-80 compressive strength or > 1N/mm^2 in 7days completely as per company specification completely of approved make of approved colour & Engineer-in-charge
Material & labour for providing the sealant( pouring grade) in the existing 10mm wide & 40mm deep groove/joint after preparation of joint as per manufacture instruction along with application of primer as per manufacture instructions. (a) Thioflex 600 shall be of M/s FOSROC/MASTERFLEX TM 700i of BASF or equivalent in CIPY. (b) Primer 7E shall be M/s FOSROC or equivalent in BASF/CIPY. Note for item No 48 &49 :- Application of epoxy and sealant shall be carried out by authorised application of manufacture.
M&L for Pre-cast cement concrete block masonry with solid block of type C1 1:3:6 (using 20mm graded stone aggregate) 10cm in width and setting in CM 1:6, complete all as specified and as directed.
M&L for Pre-cast cement concrete block masonry with solid block of type C1 1:3:6 (using 20mm graded stone aggregate) 10cm in width and setting in CM 1:4, complete all as specified and as directed.
Taking down plastering or brick or stone wallls etc including racking out joints,hacking for key, scrubbing down with water etc.
M&L Rendering 10mm thick cement mortar 1:6 on fair faces of brick masonry or concrete surface wall even and smooth without using extra cement complete all as specified and as directed
M&L Rendering 15mm thick cement mortar 1:6 on fair faces of brick masonry or concrete surface wall even and smooth without using extra cement complete all as specified and as directed
Demolition of cement concrete in roofs other than ground floor complete
M&L plain cement concrete 1:2:4 type B0 (using 12.5mm graded crushed stone aggregate) as in roof padding concrete as leveling course complete all as specified and directed
M&L for rendering 10mm thick over roof concrete surface in CM 1:3 and finishing the surface even and smooth without using extra cement with water proofing compound complete all as specified and directed. (WPC shall be measured and paid seperately).
M&L APP based polymeric membrane minimum weighing 3Kg/Sqm and minimum 3mm thick reinforced with polyster non woven fabric (Weight not less than 150 gms/Sqm)laid on primed surfaces by forced application iclbituminous primer confirming of IS-3384applied @ 0.3 ltr/Sqm and applying aluminium paint @ 100 ml/Sqm including taking out existing roof treatment complete all as specified and directed. Four cource of roof treatment consist of as under:- (a) Applying one coat of bituminous primer conforming to IS [email protected]/Sqm (b) Laying of APP based membrane as specified thickness and weight. (c) Applying one coat bitumen grade 85/25 @ 1.2Kg/Sqm. (d) Applying one coat of aluminium paint @ 100ml/Sqm
Excavating in trenches in Hard/dese soil, n exc 1.5 m wide and n exc 1.5m in depth for foundation , etc or for shafts, wells, cesspits, manholes, pier holes, etc n exc 10 sqm on plan and getting out
M&L PCC 1:4:8 type D2 (using 40mm graded stone aggregate) as in foundations, filling and mass concreting complete all as specified and as directed
M&L for plain cement concrete in surface channels and drains avg 50mm thick type B0 1:2:4 (using 12.5 mm graded stone aggregate) complete all as specified and as directed
M&L pre- cast cement concrete block masonry type C1 1:3:6 (using 20mm graded stone aggregate) with solid block, exc. 10cm in width and setting in cement and sand mortar 1:6 complete all as specified and directed.
M&L rendering 15mm thick CM 1:4 on surfaces other than fair faces of brick work finished even and smooth without using extra cement complete all as specified and as directed
M & L PCC in 1:3:6 type C-2 (using 20 mm graded stone aggrgate) as in copings including necessary formwork complete all as specified and as directed
M & L pre cast reinforced cement concrete 1:2:4 type B-l (using 20mm graded stone aggregate) as in cover slabs for man holes, water tanks etc., set in CM 1:4 complete all as specified and as directed
M&L for MS TMT bars 10 mm dia and over, cut to length, bent to shape required, and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips.
Exc in post holes each n exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around in layers not exc 25cm watering and removing surplus soil to a distance n exc 50m and making good surface in hard / dense soil.
M&L for PCC 1:2:4 type B1 (Using 20mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified and as directed
S&F pre-painted galvalume aluminium zinc coating Gl based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering fixed with self tapping screws as specified.(height upto 15mtr and above)
All as per item No 69 here-in-before, but plain sheet for ridge complete all as specified and as directed
S&F Joist, channel, angle or tee sections fixed independently without connecting plates etc. complete all as specified, conforming Fe 41 OW (Gde E-250) Quality B complete all as specified and as directed
S&F framed work such as grill fancy type, gratings with ends of bars shouldered or riveted or forged into spikes, framed guard bars, barred iron doors etc complete all as specified and as directed
M&L prepration of old surface on wall and applying one coats of distemper oil emulsion over a coat of primer complete all as specified and as directed
M&L Preparation of old surface on wall and applying one coats of distemper oil emulsion complete all as specified and as directed
Returning, filling in including spreading, levelling, watering and well ramming in layers not exc25 cm complete all as specified and as directed
Removing excavated material exc. 1.50 KM but n. exc 5 KM and depositing where directed.
Taking down u/s perished point wiring for light/fan/socket/power with all fittings and fixtures complete including making good the disturbed surfaces complete all as specified and as directed
Point wiring complete with Multi stranded copper conductor size 1.5 sqmm PVC insulated, unsheathed, FRLSH cable , 1100 volts grade conforming to IS 694 multistranded , drawn in and including rigid PVC surface type conduit / casing capping on walls/ floors/ ceiling etcwith and including metal flush boxes of suitable size and modular white plate with frame for mounting of fittings, modular type switches, regulator and also including 1.5 sqmm PVC insulated unsheathed copper cable green in colour as continuous earth continuity conductor and connecting to earth dolly, cutting chasis to the walls/ floors/ ceiling and repairing with existing surface after work, complete all as specified and directed.
One light point controlled by one switch
One celing fan /exhaust fan point controlled by one switch
All as per ser item No 78 above but using 4 sqmm PVC insulated unsheathed, multistranded copper conductor cable with 4 sqmm continuous earth conductor for one 3 pin 15 amps socket outlet on an independent board
Supply and fixing of switch modular 1 way 6 amps, 1 module with frame and cover 230 volts complete all as specified
Supply & fix ceiling rose surface backlite three terminal complete all as directed
Supply and fixing of switch modular 1 way 16 amps, 1 module with frame and cover 230 volts complete all as specified
Supply and fixing of socket modular 6/16 Amps 2/3 pin combined 2 module with frame and cover 230 volts grade complete all as specified
Supply & fixing only LED batten with aluminium housing provided for efficient heat dissipation with polycarbonate diffuser and intregrated electronic driver1 x 20 watts fixing on wall/ celing complete all as specified as directed.( FOR PASSAGE)
Supply and fixing only LED luminaires square type 2x2 35/36 W with environmental friendly new generation aestheticall designed ,ultra modern recess mounting iuminaire with high brightness SMD LEDs as light sourse sutible for armstong/gypsum or similar ceiling mounting system including connecting to ceiling rose with twin copper conductor of size 0/0.24 complete all as specified and directed by Engr-in-charge.
Supply and fix Suspension LED (Pendant) luminaires with efficient Diffuser ensuring perfectly uniform illumination, ensured optimised and unparalleled light distribution. Inter-connectable luminaires for aesthetically appealing downlight application of Cap 20W all as specified and directed
Supply and fix extra efficient (120 Lm/W) next Gen Highbay with Elliptical design, modular lens Optics for optimized Lighting distribution to improve 20% operational efficiency, with EMC/ EMI Complient Potted Driver & easy maintenance, Flicker free Illumination for Industrial Space all as specified and directed.
S&F exhaust fan 230 volts 300 mm sweep 900 RPM having metal body and metal blade with louver shetter including cutting the wall of stone/ brick masomery as per the size of exhaust fan including grouting the bolts,nuts etc for fixing necessary connection with three core flrxible wire from exhsust fan to ceiling rose complete all as directed . MAKE Havells/CG / BAJAJ
M&L for submain wiring with 2 runs of 2.5sqmm single core PVC insulated stranded copper conductor cable drawn through suitable rigid non metallic PVC conduit with one run of1.5 Sqmm PVC insulated copper conductor cable as earth continuity conductor and necessary connections all as directed. Note : 2 runs of 2.5 sqmm PVC insulated unsheathed copper conductor and 1 run of 2.5sqmm PVC insulated unsheathed copper conductor and 1 run of PVC conduit will be measured as single run (FOR HIGHBAY LIGHT /AIR CIRCULATOR /BUILDING SECURTIY LIGHT)
M&L for submain wiring with 2 runs of 4.0 sqmm single core PVC insulated stranded copper conductor cable drawn through suitable rigid non metallic PVC conduit with one run of 4.0 Sqmm PVC insulated copper conductor cable as earth continuity conductor and necessary connections all as directed. Note : 2 runs of 4 sqmm PVC insulated unsheathed copper conductor and 1 run of 4.0sqmm PVC insulated unsheathed copper conductor and 1 run of PVC conduit will be measured as single run (for AC point)
M&L for submain wiring with 2 runs of 6.0 sqmm single core PVC insulated stranded copper conductor cable drawn through suitable rigid non metallic PVC conduit with one run of 6.0 Sqmm PVC insulated copper conductor cable as earth continuity conductor and necessary connections all as directed. Note : 2 runs of 6 sqmm PVC insulated unsheathed copper conductor and 1 run of 6.0sqmm PVC insulated unsheathed copper conductor and 1 run of PVC conduit will be measured as single run
M&L for submain wiring with 4 runs of 6.0 sqmm single core PVC insulated stranded copper conductor cable drawn through suitable rigid non metallic PVC conduit with one run of 6.0 Sqmm PVC insulated copper conductor cable as earth continuity conductor and necessary connections all as directed. Note : 4 runs of 6 sqmm PVC insulated unsheathed copper conductor and 1 run of 6.0sqmm PVC insulated unsheathed copper conductor and 1 run of PVC conduit will be measured as single run
M&L for submain wiring with 4 runs of 10 sqmm single core PVC insulated stranded copper conductor cable drawn through suitable rigid non metallic PVC conduit with one run of 10 Sqmm PVC insulated copper conductor cable as earth continuity conductor and necessary connections all as directed. Note : 4 runs of 10 sqmm PVC insulated unsheathed copper conductor and 1 run of 10 sqmm PVC insulated unsheathed copper conductor and 1 run of PVC conduit will be measured as single run
S&F SPN MCBs distribution board of sheet metal enclosure factory made double door powder coated single pole and neutral with 200 amps rated bus bar 4 way 240 Volts
S&F SPN MCBs distribution board of sheet metal enclosure factory made double door powder coated single pole and neutral with 200 amps rated bus bar 8 way 240 Volts
S& F MCB SPN 63 Amps 10 KA capacity 240 Volts all as directed Make :- Indo Asian/ C&S /CG/Legrand
S& F MCB SPN 32 Amps 10 KA capacity 240 Volts all as directed Make :- Indo Asian/ C&S /CG/Legrand
S& F MCB single pole 6 to 32 Amps 10 KA capacity 240 Volts all as directed Make :- Indo Asian/ C&S /CG/Legrand
Triple pole and earth enclosure with a three pin and earth plug with socket complete with one triple pole MCB 63 Ampscomplete all as specified and as directed
Supply and fix entire drum assembly, consisting of round pipe, brackets, flange assembly, roller chains etc., automated with suitable motor for lifting of capacity 1500 kg Jielong Rolling Shutter complete kit all as specified and directed by Engr-in-charge. Size of rolling shutter required - Width 27 feet and hight 15 feet
S&F High efficient LED Street Bldg security light fitting 35 watt, with Aluminium pressure Die cast housing parts for long life, High purity PC Fresnel diffuser with silicon gaskets for IP65 Protection, in-built electronic driver pre- wired up to terminal block,Suitable for external pole dia. Up to 35 mm, LED Make-Nichia/Cree/Osram, CRI >70,Temperature range- 0 to 45DegC, Driver efficiency>85%, Power factor>0.95, THD<10%, Colour Temperature- 5700K, Surge protection in CM-3.5KV, 50000 burning hours as per L70 Criteria, Multistage Isolated Constant Current- Constant Voltage Operated driver with range 150-270V AC and Safety Extra Low Voltage Safe level<60V DC as per IEC standard.
Supply and fixing Distribution board Power line Vertical TPN MCCB DBs with IP 54 Protection metal door 415 volts,8 way with double door fixed on flush to the wall including making the hole in th wall and fixing the DB including cement work and plastering complete including comprising the following all as specified and as directed Make of VTPN MCCB 125A DBs INDOASIAN /ABB/L&T (a) MCCB with thermal magnetic release 415 volts 4 pole 100 Amps capacity and breaking capacity 25 KA - 01 No (b) MCB 230 Volt SP 10 KA braeking Capacity of cap 6 to 32 Amp-12 Nos
Earthing complete with 600x600x6.00mm thick GI earth plate electrode buried directly in ground not less than 2.25 mtr below GL with the top edge of the plate at a depth not less than 1.5 mtr from GL, connected to GI earth lead of 4.0 mm dia by means of nuts, bolts, washers, checknuts etc, made out of galvanised iron or steel, earth wire protected by galvanised iron pipe, connected to main switch board complete including necessary earth work,excavation,PCC chamber, watering pipe, funnel, wire mesh, RCC chamber cover etc all as specified and directed in EP No:3 of SSR Part-I
M & L for taking out existing old vintage/unserviceable LT panel board with all unserviceable control switches complete after taking proper shut down of electric supply and disconnecting all in coming/ out going connections & keeping in safe custody complete all as specified and as directed.
Supply & install, testing and commissioning INDOOR type LT panal consisting of double door, separate compartment for each out going feeders with locking arrangement for each feeder floor mounting fabricated out of 2 mm thick MS sheet on angle iron frame of 25x25x5mm and legs made of angle iron 40x40x6, painted with powder coated and pre coted primer including necessary PCC 1:3:6 type C2 foundation of panel boad and earth work including comprising the following :- (a) Bus bar chamber of 3 phase and neutral 4 strip 415 volts with 600 Amps copper strip - 1 set (b) Moulded Case Circuit Breaker 3 pole 35 KA breaking capacity 400 Amps capacity with thermal magnetic trip unit (TMD) - 1 Nos (in comming) (c) Moulded Case Circuit Breaker 3 pole 25 KA breaking capacity 250 Amps capacity with thermal magnetic trip unit (TMD) - 1 Nos (Out going) (d) Moulded Case Circuit Breaker 3 pole 25 KA breaking capacity 100 Amps capacity with thermal magnetic trip unit (TMD) -2 Nos (Out going) (e) Moulded Case Circuit Breaker 3 pole 25 KA breaking capacity 63 Amps capacity with thermal magnetic trip unit (TMD) - 3 Nos (Out going) (g) Three phase volt meter - 01 No (h) Three phase Ammeter - 01 No (j) LED Indicator lamp Red, Yellow, Blue - 01 Set (k) Complete internal wiring with suitable copper condutor wires - 1 Lot Note : (i) All termination of existing cable should be provided with copper lugs/thimbles and suitable size of glands & rate for the same is deemed to be included in the item
M&L earthing complete with galvanised iron plate electrode 600 x 600 x 6.00mm thick GI earthing lead burried directly in ground vertically to a depth not less than 2.25 mtr deep below GL with the top edge of the plate at a depth not less than 1.5 mtr from below normal GL, connected to and including Galvanised iron strip 32x6 mm as earthing lead by means of nuts, bolts, washers, checknuts of galvanised iron and connected to earthing test point all as shown in electric plate No. 3 of SSR Part l of 2010 and as specified or indicated and testing on completion including excavation / earth work in any type of strat PCC (1:3:6) type C1 earthing chamber, pre cast slab 50 mm thick in cement cioncreat (1:2:4) type B1 (Reinforced with welded steel wire fabric (XPM)) weight not less than 4 Kg/sqm,cast iron frame, funnel with wire mesh, including GI earth strip with GI protection pipe of 40mm medium grade 7.5 meter long etc complete and testing on completion all as specified and directed. Note: 1. Rate quoted shall deemed to include cost of excavation in any type of strata, RFR and removal upto 50metre, PCC pit, funnel and RCC cover plate. 2. GI strip above 7.5m will be measured and paid seperately. 3. Earth resistance not exceeding 1.0 ohm.
Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or burried in ground or drawn in conduit/GI pipe or fixed to poles or any other indicated situation for loop earthing etc as required of GI strip 32 x 6 mm complete all as specified and as directed
Supply and install hi wall split units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 5 star rating and EER 3.2.of capacity of 2 TR and 220 to 250 volt 50 Hz all as spcified and directed (including copper pipe and refrigerant gas).
Supply and install hi wall split units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 5 star rating and EER 3.2.of capacity of 1.5TR and 220 to 250 volt 50 Hz all as spcified and directed (including copper pipe and refrigerant gas).
S&F voltage stablizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 volts to 250 volts with out put voltage stablized at 230 volts with accuracy of +/- 2.5% and of capacity 5 KVA. Make-V Gaurd/Oricon/Orient
S&F voltage stablizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 volts to 250 volts with out put voltage stablized at 230 volts with accuracy of +/- 2.5% and of capacity 4 KVA. Make-V Gaurd/Oricon/Orient
M & L for HDPE pipe 20 mm dia fixed to wall on roof complete all as directed.
Making opening/drilling of size 65 mm dia, using heavy duty stone driller/cutter machine in the stone machinry wall for installing spilit type air conditioners and for passing suction and discharge refrigerant pipe lines, drain pipe, cable etc and making good the disturbed surface all as directed.
B5BUILDING SOLUTIONS
Lucky Enterprises
M/S Suresh Raju
VSHVAS CIVIL AND ELECTRICAL SERVICES PRIVATE LIMITED
S CHANDRASHEKAR (SREE BUILDERS)
GKR and CO
Sreyas Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .