Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.8 LAccepted-AOC | L1 | Accepted-AOC Being L1 and found in order | |
| 2 | L2₹11.2 L+₹7,513.61 (0.68%)Rejected-AOC | L2 | Rejected-AOC Not being L1 | |
| 3 | L3₹11.2 L+₹14,508.65 (1.31%)Rejected-AOC HOUSE NO 102 LANE NO 4 C ANAND NAGAR BOHRI JAMMU 180002 J K | JAMMU | JAMMU AND KASHMIR | 180002 | L3 | Rejected-AOC Not being L1 | |
| 4 | L4₹11.9 L+₹84,432.05 (7.62%)Rejected-AOC C O OPPOSITE MH MANDA POONCH ROAD AKHNOOR 181201 J K | JAMMU | JAMMU AND KASHMIR | 181201 | L4 | Rejected-AOC Not being L1 | |
| 5 | L5₹12.3 L+₹1.2 L (10.9%)Rejected-AOC | L5 | Rejected-AOC Not being L1 |
Tender Value
Refer Docs
EMD Value
₹28,000
Closing Date
9 Dec 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
HQ 135 WE
v C o 56 APO
SPL REP OF 11 KV HT OVERHEAD LINE TO UNDER GROUND CABLE AND CONNECTED ITEM OF MANDIWALA FEEDER FROM VILL POTHA TO MAIN ROAD AT MANDIWALA UNDER GE SOUTH AKHNOOR
2020_MES_393916_1
CWE/JA-30/2020-21
Open Tender
Civil Works
Item Rate
180 days
Akhnoor
As per NIT
7 documents required · 7 mandatory
₹500
Yes
GE South
₹28,000
Yes
16 Jan 2021
10 Nov 2020
11 Dec 2020
10 Nov 2020
9 Dec 2020
26 Nov 2020
10 Nov 2020 - 16 Nov 2020
60 days
Amount
Dismantling of old unserviceable ACSR Conducter of any size and any type, complete all as specified and directed.
Dismantling of old PCC Pole any size and any type, complete all as specified and directed.
Dismantling of old unserviceable insulater of any size and any type, complete all as specified and directed.
Excavation in trenches n.exc. 1.5 mtr wide and n.exc 1.5 mtr deep for foundations of poles/stays/cable etc not exc 10 Sqm area on plan and getting out in soft/loose soil, complete all as specified and directed.
All as per item No. 4 here-in before but depth exceeding 1.5 mtr and not exceeding 3 mtr, complete all as specified and directed.
Removing surplus soil to a distance not exc. 50 mtr and depositing where directed at a level n.exc. 1.5 mtr above the starting point, complete all as specified and directed.
Supply and erecting, in truly vertical position prestressed concrete pole 11 Mtr long of cross section 152mm x 152 mm at top and 152mm x 260mm at bottom class 9 complying with requirement of IS-1678-1978 including painting of poles with two coats of synthetic enamel paint over a coat of primer, black and white strips 30 cm wide each (5 Nos) upto 1.5 meter high from coping including numbering of poles, complete all as specified and directed. (Note - PCC, earth work and MS work in cross arms etc. shall be measured and paid for separately).
PCC (1:4:8) type D-2 using 40mm graded stone aggregates as in foundation and sides of poles & PCC blocks etc including necessary form work, complete all as specified and directed.
PCC (1:3:6) type C-1 using 20mm graded stone aggregates as in stay and coping of poles including necessary form work and fair finish to exposed surface without using cement, complete all as specified and directed.
M&L for PCC (1:2:4) type B-1 using (20mm) graded stone aggregates as in PCC coping of poles or for stays, complete all as specified and directed.
Supply and fixing HT lightning arrestor metal oxide type (gas less) heavy duty single pole suitable for rated system voltage of 12 KV and working rated arrester voltage of 9 KV with normal discharge current of 10 KA all as per IEC 99.4 effectively earthed, complete all as specified and directed. Note :- Test certificate for LA shall be suppied, without which no payment shall be admissible.
S & F Anti Climbing Device spring type fabricated out of MS Bar (round square and flat) including nut, bolts and washers and welding in two havles made to shape to suit the cross section of the pole, complete all as specified and directed.
S & F Danger notice plate for HT pole of size 20cm x 25cm of 1.6 mm thick mild steel sheet vitreous enamelled white with letters, figure and conventional skull and bones "DANGER" written in English and Punjabi, Hindi in signal red colour and fixed with MS clamps made out of 25mm x 3mm MS flat iron bolts, nuts complete including two coats of aluminium paint over a coat of red oxide primer, complete all as specified and directed.
S&F Aerial bunch cable of 11 KV three phase3x95Sqmm +70 Sqmm cable constitute of three single core of screend cable twisted around an Al alloy insulated messenger conducter enabling it to carry the full load of the cable with screend by an extuded semi conducting layer and a coppar tape with XLPE insulation over all sheathed with PVC/Polythelene incl anchor clamp,suspension clamp, inline connecter,service clamp,insulation peircing connecter, Insulation peircing connecter for Tap from bare lines mounted on PCC pole or Steel tubular pole, complete all as specified and directed.Make Havells, Polycab, Finolex, CCI
Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick burried directly in ground vertically to a depth not less than 3 meter below ground level with top edge of the earth plate at a depth not less than 2.25 mtr below ground level earth plate surrounded from all sides by 15cm thick packed layer of charcoal dust and common salt filling in alternate layers, all around top and bottom and electrode connection by using GI Wire 4 Sqmm (upto the body of equipment) by means of bolts, nuts, check nuts and washers made of galvanised iron and thimbles. GI pipe 20mm bore light grade for watering with funnel and wire mesh including medium grade GI Pipe 40mm bore protection and 40 mm GI pipe light grade for protection of strip. PCC chamber in cement concrete 1:3:6 type C-2 and RCC pit cover in M20 (design mix) complete all as shown in Electrical Plate No.3 of MES Standard Schedule of Rates (Part-I) of 2009 complete all as specified and testing on completion. i) The unit rate shall include for protection pipe, GI water pipe, wire mesh, funnel, excavation. RCC pit cover, test point, 32mm GI strip from top of earth plate upto 5M above ground level and if GI protection is less than 5 meter, no price adjustment shall be made. iii) If the testing result of earthing work is not been found satisfactorily then the contractor shall do other earthing work at his own cost and nothing shall be permissible on this account. iv) Earthing work will be carried out in presence of MES representative.
S & F in replacement Cable jointing kit for 11 KV (Earthed) grade cable for outdoor type termination heat shrinkable joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm, complete all as specified and directed. Make: Denson/ M Seal/ Raychem
Jiwan Singh
SUMEET TRADING CORPORATION
Usha Engineering Co.
Shree Balaji Construction
darshan kumar gandhi
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .