Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹6.5 LAdmitted-Finance | -17.50% | ₹6.5 L | L1 | Admitted-Finance |
| 2 | L2₹6.8 LAdmitted-Finance | -13.20% | ₹6.8 L | L2 | Admitted-Finance |
| 3 | L3₹6.8 LAdmitted-Finance | -13.10% | ₹6.8 L | L3 | Admitted-Finance |
Tender Value
₹7.8 L
EMD Value
₹15,700
Closing Date
18 Feb 2026, 6:00 pmClosed
SPD, RCSCE, Jaipur, Block No. 6, Dr. Radha Krishan
SPD, RCSCE, Jaipur, Block No. 6, Dr. Radha Krishan Siksha Sankul, JLN Marg, Oppsite of OTS, Jaipur
Major Repair Work at GOVT. SENIOR SECONDARY SCHOOL BHOORTHAL, JALSU, JAIPUR
2026_RCSCE_535061_37
NIT15 (CIVIL)/2025-26/6940 DATE 02-02-2026 ADPC SMSA JAIPUR
Open Tender
Civil Works
60 days
Major Repair Work at GOVT. SENIOR SECONDARY SCHOOL
As per Tender Documents, NIB Documents
2 documents required · 2 mandatory
₹1,000
DPC RMSA JAIPUR / MD RISL JAIPUR
₹15,700
15 Mar 2026
9 Feb 2026
19 Feb 2026
9 Feb 2026
18 Feb 2026
9 Feb 2026
Building & Sainatary Work Based on BSR PWD - 2022, Jaipur Circle, Electric Work Based on BSR PWD 2022, Jaipur Circle, Part -A Civil Work
Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge
Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer-in-charge. 1: 3: 6 or richer mix.
Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel props and removal of formwork for upto floor five level for : Suspended floors, roofs, landings, staircases, balconies, girders, cantilevers, bands, coping bed plates, anchor blocks, sills, chhajjas, lintel, beam, plinth beam etc.
Providing and laying in position specified grade of cement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement for Beams, suspended floors, roofs, griders having slopes up to 15º, landings, balconies, shelves, chajjas, lintels, bands, plain windows sills, staircases and spiral staircases etc. M20 grade Nominal Mix / Design Mix
Grading roof for water proofing treatment with water proffing compound Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
Brick work with clay flyash F.P.S. brick (IS 13757- 1993 ) of class designation 75 in superstructure above plinth level upto floor five level in : Cement mortar 1 : 6 (1 cement : 6 coarse sand)
Supplying & Stacking good earth at site complete including loading unliading & transporation etc. Filling qvailable excabated earth (excluding rock) in trenches, plinth side of foundation etc,in layers mot excluding lead up to 50mt and with all lift
Kharanja - Random Rubble dry stone kharaja under floor
PCC: Providing and laying in position cement concrete including curing compaction etc. complete in spcified grade excluding the cost of centering and shuttering all work upto plinth level 1:3:6(1 cement:3 Coarse sand :6 graded stone aggregate 20 mm nominal size).M 10 grade nominal mix
Kota stone slabs 25 mm thick inover 20mm (Av) thick base laid over and jointed with grey cement slirry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1:4 ( 1 cement :4 coarse sand )te For area of each slab 2001 to 5000 Sqcm
Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor five level. ('Original producers' who manufacture billet directly from iron ores and roll the bilets to produce steel conforming to IS:1786)
6 mm thick cement plaster to celling of mix 1:3 ( 1Cement :3Fine sand)
Internal Plaster :- Plaster on new surface on walls in cement sand mortar 1:6 including racking of joint etc. complete fine finish : 12mm thick Sqm
External Plaster :- Plaster on new surface on walls in cement sand mortar 1:6 including racking of joint etc. complete fine finish : 20mm thick Sqm
Providing and applying white cement based putty over plastered surface to prepare the surface even and smooth complete
Distempering with 1st quality acrylic washable distemper (ready mixed) of approved manufacturer and of required shade and colour completeincluding all scaffolding as per manufacturer's specification. Two or more coats on new work including prepartion of base with primer, putty, lippy etc complete in all respect.
Finishing walls with acrylic smooth exterior paint of required shade including all scaffolding. New work (two or more coat applied @1.67/ ltr/10 sqm over and including base coat of water proofing cement paint applied @ 2.20 kg/ 10 sqm.)
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 13.49 MB
NIT15Civilandspcial.pdf
Tender Documents • 22.78 MB
BOQ_955296.xls
BOQ • 0.25 MB
Download all tender documents and submit your bid