| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹29.2 LAccepted-AOC NAGLA UDHA NEAR PRIMARY SCHOOL POST DHANOLI AGRA UP AGRA 282010 | AGRA | AGRA | UP | 282010 | L-1 | Accepted-AOC FOUND LOWEST AND REASONABLE | |
| 2 | L-2₹30.9 L+₹1.7 L (5.94%)Rejected-Finance 9 NAROTTAM KUNJ MADHU NAGAR AGRA CANTT 282001 | AGRA | UTTAR PRADESH | 282001 | L-2 | Rejected-Finance Being other than lowest | |
| 3 | L-3₹34.9 L+₹5.8 L (19.8%)Rejected-Finance 38 49 D OLD IDGAH COLONY AGRA U P 282001 | AGRA | AGRA | UTTAR PRADESH | 282001 | L-3 | Rejected-Finance Being other than lowest | |
| 4 | L-4₹35.0 L+₹5.8 L (20.0%)Rejected-Finance | L-4 | Rejected-Finance Being other than lowest | |
| 5 | L-5₹38.1 L+₹8.9 L (30.7%)Rejected-Finance | L-5 | Rejected-Finance Being other than lowest |
Tender Value
Refer Docs
EMD Value
₹55,000
Closing Date
30 Sept 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) (TECH AREA) AGRA
GE (AF) (TECH AREA) AGRA
REPAIR / REPLACEMENT OF U/S TARMAC LIGHTS AT CERTAIN DISPERSAL IN TECHNICAL AREA AT AF STN AGRA
2020_MES_374826_1
8200-1227/E8
Open Tender
Civil Works
Item Rate
180 days
GE (AF) (TECH AREA) AGRA
For enlisted contractor scanned copy of contractor appl on letter head scanned copy of tender fee in the form of DD or bankers cheque scanned copy of enlistment letter scanned copy of PF code Number for un enlisted contractor as per NIT
8 documents required · 8 mandatory
₹500
Yes
GE (AF) (TECH AREA) AGRA
₹55,000
Yes
19 Dec 2020
5 Sept 2020
3 Oct 2020
5 Sept 2020
30 Sept 2020
18 Sept 2020
7 Sept 2020 - 11 Sept 2020
60 days
Amount
Taking down old U/S panel including main switch/MCB/MCCB etc complete all as specified and directed. Note : Old u/s panel including all fittings/fixtures shall be contractor's property as per schedule of credit.
Taking down / out U/S cable of different size from certain location all as specified and directed. Note : Old u/s cable shall be contractor's property as per sch of credit.
Excavation in trenches not exceeding 1.5 Mtr wide and not exceeding 1.5 Mtr depth for laying of cable, errection of poles, stays and pipe line etc and getting out in soft / loose soil complete all as specified and directed.
Surface excavation not exceeding 30cm deep and averaging 15cm deep and getting out in soft / loose soil complete all as specified and directed.
M&L for soling (or sub base) of thickness 150 mm with broken boulders or quarried stone,inter stices filled, surface formed and rolled and consolidated to required gradient and camber complete all as specified and directed.
Returning, filling in , including spreading , leveling, watering and well ramming in layers n.exc. 25 cm thick in soft / loose soil complete all as specified and directed.
Removing surplus excavated materials n.exc.50mtr and depositing where directed at level n.exc 1.5 mtr above the starting point complete all as specified and directed
M&L for plain cement concrete 1:3:6 type C-2 (using 40mm graded crushed stone aggregate) as in foundation filling and mass concrete, complete all as specified and directed.
M&L for brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in cement motar 1:4 complete all as specified and directed
M&L for rendering 15 mm thick 1:4 on fair faces of brick work or concrete surfaces finished even and smooth (without using extra cement) all as specified and directed
M&L for painting on new plastered surfaces of walls with, 2 coats of cement base points over one cost of primer all as specified and directed
S & F LED Flood light 150 W efficient high output emitter with IP66 protection including hanging/fixing arrangement (with & including suitable size of angle iron, pipe and nut bolts etc) including taking down old unserviceable light fitting of any type/ size complete all as specified & directed. Make : Crompton cat part No LFLN-150-CDL/60-M or equivalent model in specified makes as per list of makes. Note : Old u/s light fittings any type shall be contractor's property as per schedule of credit.
S & F LED Flood light 250 W efficient high output emitter with IP66 protection including hanging/fixing arrangement (with & including suitable size of angle iron, pipe and nut bolt etc) including taking down old unserviceable light fittings of any type / size complete all as specified & directed. Make : Crompton cat part No LSFO-250-CDL/60 or equivalent model in specified makes as per iist of makes. Note : Old u/s fittings any type shall be contractor's property as per schedule of credit
Supply, laying, testing of cable XLPE insulated, screened, PVC insulated, bedded, armoured heavy duty electric under ground LT cable 1100 volts grade with stranded aluminium conductor of size 10 sqmm 4 core complete all as specified and directed
All as per ser items No 14.00 above but for cable size 16 Sqmm 4 core.
All as per ser items No 14.00 above but for 50 Sqmm 3.5 core.
M&L for GI tubing 50 mm bore (light grade) with all fittings, laid in trenches or under road crossing as protection pipe or fixed alongwith walls/poles with necessary clamps, nuts bolts and washers etc including taking out/ down old unserviceable pipe complete all as specified and directed. Note : Old u/s GI pipe including fittings shall be contractor's property as per schedule of credit.
M&L for GI tubing 80 mm bore (light grade) with all fittings, laid in trenches or under road crossing as protection pipe or fixed alongwith walls/poles with necessary clamps, nuts bolts and washers etc including taking out/ down old unserviceable pipe complete all as specified and directed Note : Old u/s GI pipe including fittings shall be contractor's property as per schedule of credit.
M&L for providing sand cushioning with dry fine sand including filling, spreading, levelling in layers in cable trench for protection of under ground cable complete all as specified and directed. Note : Only punned thickness shall be measured & paid
Supply and lay well burnt bricks sub-class 'B' locally available old size laid flat accross the length of trench for protection of cable complete all as specified and as directed.
M & L for earthing complete with galvanised steel earth plate electrode 600mmx600mmx6 mm thick directly burried in ground (earth pit not less than 2.25m deep below normal ground level) with top edge of earth plate not less than 1.5 m below the normal ground level with and including provision of earth test point terminal block made out of gun metal or phosphorous bronze of size 75x75x25 mm drilled and screwed with and including 3 nos. 8 mm dia 25 mm long hexagonal head GI screw and necessery connection complete, connected to GI strip 25x4mm dia by means of bolts, nuts, check nuts and washers of GI or steel, 15mm bore GI pipe medium grade including necessery fittings for protection of earthing strip, watering pipe 20mm bore GI medium grade, concrete chamber in PCC (1:4:8) type D-2 using 40mm grade aggregate, coping shall be in PCC (1:3:6) type C-1 using 20mm grade aggregate and internal surfaces of cocrete chamber shall be given 12mm thick plaster in CM(1:4), funnel with wire mesh including 50mm thick cover of RCC(1:2:4) type B-1 using 20mm grade stone aggregate reinforced with 8mm MS deformed bar@75mm C/C both ways, charcoal dust and common salt all as shown in electrical plate no. 3 of SSR part-1 (2009) inclding all necessary excavation & earth work and removal of surplus soil to a distance not exc 50m, providing connection points with MS bolts & washers as required and connection from earth test point to earth electrode with same GI strip alongwith protection pipe (upto a distance of 7.5 mtr is included in unit rate) and testing on completion complete all as specified and directed.
Boring of holes under road, pavement, hard standing by trenchless technology using ultra sound technique and necessary machine complete all as specified and directed.
S&F Weather Proof thermo plastic (Polysterene) Cable Junction box , having protection class IP-66 and of overall size 210mm x 155mm x 92mm having metric knockouts on the wall, duly fixed with the pole with aluminium strip (25x3mm) clamp, GI bolts, nuts, washers and 2 Nos polymide weather proof cable glands of cable sealing range 10mm to 17mm (Complete with check nut) and including 1 No 30 Amps 4 Way cable connector and 1 No. 6 Amps SP MCB including taking down old unserviceable cable junction boxes complete all as specified and as directed. Make of Box : HENSEL (Cat No.- DK 2525G) or Equivallent model in SPELSBERG / RITTAL/SINTEX Make of Cable gland : HENSEL (Cat No. - 1555.25.17) or Equivallent in SPELSBERG / RITTAL Note : Old u/s cable junction boxes any type shall be contractor's property as per schedule of credit.
S&F PVC insulated, sheathed twin core copper wire of size 1.50 sqmm duly passing through the holes of existing steel pole / street/ flood light brakets including necessary connection at pole mounted street / flood light junction box and at the street light fittings all as specified and as directed
Design, supply, erection, testing and commissioning of outdoor type LT Feeder Pillar Box of overall size not less than 1600 mm width x 700mm Height (With Canopy & Base Channel) x 400mm Depth, M.S. Channel Base Frame mounted (to be mounted on the brick pedestal of total height 1050 mm i.e. 600mm above GL and 450mm below GL with and including 150 mm thick PCC 1:2:4 type B2 flooring on top of pedestal and 4 Nos 12 mm dia, 300 mm long countersunk bolts with nouts and 10 mm thick plaster on all sides and top, finished even & smooth w/o using extra cement), suitable for 3 phase 4 wire, 415 volts AC supply and having 4 Nos Aluminium bus bars of rating 150 amps, Provision of Spreader link to both incoming & Outgoing MCCBs for termination of cables . The Feeder Pillar shall be fabricated in a approved / certified factory / fabrication House having CPRI test certificate IP-56 and short critical test 2000 Amp latest (wihtin 02 years) for similar type of Feeder Pillar and having modern fabrication and testing facility which includes atleast seven (07) tanks pre treatment facility comprising of de-greasing, rinsing, de-rusting, rinsing, phosphating, rinsing and passivation followed by powder coated painting (thickness not less than 80 Micron) with approved shade of RAL 7032 (SIEMENS GRAY). The Feeder Pillar shall be provided with suitable rubber gasket to make it completely dust and vermin proof and degree of protection not less than IP-56 and general construction conforming to IS : 13947. The feeder pillar shall be made out of 3.00mm thick CRCA mild steel sheet and 3.00mm thick gland plate and having compartmentalized construction for individual switchgears and Bus Bars and having front opening facility (with double layer shutter) and rear opening facility with single layer shutter with locking facility and 2 side slanting canopy type roof on top and mild steel channel (MC-75) base frame at bottom, suitable for mounting on the brick pedestal through grouting bolt, The panel board shall be provided with ventilation facility in the form of louvers for better heat dissipation. The feeder pillar shall be comprising of the followings :-
PROVISION FOR CABLE ENTRY :- The provision for cable entry / exit shall be provided in the bottom for both incoming and outgoing cables.
BUS BARS & INTERNAL CONNECTIONS :- The bus bars should be made of Aluminium, duly insulated with 1100 volts grade standard colour coded heat shrink type PVC sleeves and rigidly mounted on suitable size 'F' class insulators of non hygroscopic non combustable, track resistant, high strength FRP / SMC / DMC material. 4 Nos Aluminium bus bars of rating 150 amps, . For all internal connections from main bus bars to switch gears shall be carried out with heat shrink type PVC insulated aluminium flats of suitable size and from bus bars to MCBs with suitable size FRLS PVC insulated multi flexible type copper wires as per the current carrying capacity of individual switch gears. Earthing bar shall be provided as per standard practice and shall be made of Galvanized Steel flats of size 25mm x 6 mm
INCOMING :- (i) 4 pole MCCB ( with panel mounted rotary handle ) having breaking capacity 16 KA, Fixed magnetic and adjustable thermal setting from 80% to 100% and of rating 100 Amps. Make : LEGRAND /SCHNEIDER / ABB
OUTGOINGS :-
(i) 4 pole MCCB ( with panel mounted rotary handle ) having breaking capacity 16 KA and thermal setting from 80% to 100% and of ratings :-40 Amps - 02 Nos Make : LEGRAND /SCHNEIDER / ABB
DISPERSAL LIGHT CONTROLLER This should be made of the following articles complete with all wiring harness as required :-
(ii) TPN MCCB 16 Amps having breaking capacity 10 KA - 01 No Make : LEGRAND /SCHNEIDER / ABB
(ii) 3 Pole power contactor, suitable for 415 volts AC 50 Hz supply and current carrying capacity 32 Amps. - 01 No. Make : L&T (ML-2) / BCH / TC
(iii) TPN MCCB 10 Amps having breaking capacity 10 KA - 02 Nos Make : LEGRAND /SCHNEIDER / ABB
(iv) DIN rail mounted, Astronomical Time Switch, 1 Channel, suitable for operate in 230 volts AC 50 Hz supply and operating mechanism based on sun rise / sun set timing of a preset lattitude and longitude of a particular location - 01 No. Make : LEGRAND (Cat No. - 412654 Alpharex D21 astro) OR Equivallent model in SCHNEIDER
MISCELLANEOUS ITEMS :- (a) SP MCB 6 Amps 10 KA (For Control Wiring) - 01 No. Make : LEGRAND /SCHNEIDER / ABB
(b) 4 Way ebonite cable connector, 32 Amps, with GI Bolts, Nuts, Flat Washers & Spring Washers etc. complete. - 02 Nos. Make : ACDC / RAMANUJ / DEEPAK
INSTRUMENTATION SYSTEM :-
(a) LED Phase Indicating light, shrouded type, 22mm, with cluster LED suitable for 230 Volts AC - 01 set of 3 lamps (RED,YELLOW & BLUE) Make : L&T /SIEMENS/ C&S (RASS)
(b) Digital Volt Meter (96mm x 96mm), 4 1/2 digit,Accuracy Class 1% - 01 No. Make : L&T / AE/ CONZERV / ELMEASURE
(c) Digital Ammeter (96mm x 96mm), 4 1/2 digit,Accuracy Class 1% - 01 N0 Make : L&T / AE/ CONZERV / ELMEASURE
(d) C.T having Ratio 100/5, tape wound,BPL, rated burden 5 VA - 03 Nos. Make : L&T / AE / ELMEASURE / RISHABH
(g) Danger Notice Plate duly written in Signal Red colour on Aluminium plate in English & Hindi language and of size not less than 150mm x 100mm - 02 Nos
M/s SCHOLASTIC ENTERPRISES
GUPTA ENGINEERING WORKS
D K Bhugra and Brothers
M/s S.M. Construction
AGRA AND COMPANY
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .