Loading…
Loading…
Tender Value
₹70.6 L
EMD Value
₹1.4 L
Closing Date
2 Apr 2026, 3:00 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
TENDER
17 conditions · 3 needing a document upload
The tenderer must have minimum average annual contractual turnover of V/N or "V" whichever is less V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover.
Tenderer should have valid "A" class electrical contractor license issued by electrical inspector to state government and submit it along with the Bid offer. If "A" class electrical contractor license has been expired, tenderer should also submit the receipt of renewal electrical contractor license issued by electrical inspector to state government, along with bid offer. At the time of contract agreement, contractor must submit valid "A" class electrical contractor license issued by electrical inspector to state government. If tenderer have not submit the valid "A" class electrical contractor license/License renewal receipt, the offer will be summarily rejected.
25 conditions · 11 needing a document upload
Documents to be Submitted Along with Tender (i) The tenderer shall clearly specify whether the tender is submitted on his own (Proprietary Firm) or on behalf of a Partnership Firm / Company / Joint Venture (JV) / Registered Society / Registered Trust / Hindu Undivided Family (HUF) / Limited Liability Partnership (LLP) etc. The tenderer(s) shall enclose the attested copies of the constitution of their concern, and copy of PAN Card along with their tender. Tender Documents in such cases are to be signed by such persons as may be legally competent to sign them on behalf of the firm, company, association, trust or society, as the case may be. (ii) Following documents shall be submitted by the tenderer:(a) Sole Proprietorship Firm: (i) All documents in terms of Para 10 of the Tender Form (Second Sheet) above. (b) HUF: (i) A copy of notarized affidavit on Stamp Paper declaring that he who is submitting the tender on behalf of HUF is in the position of 'Karta' of Hindu Undivided Family (HUF) and he has the authority, power and consent given by other members to act on behalf of HUF. (ii) All other documents in terms of Para 10 of the Tender Form (Second Sheet) above. (c) Partnership Firm: (i) All documents as mentioned in para18 of the Tender Form (Second Sheet). (d) Joint Venture (JV): All documents as mentioned in para 17 of the Tender Form (Second Sheet). (e) Company registered under Companies Act2013: (i) The copies of MOA (Memorandum of Association) / AOA (Articles of Association) of the company (ii) A copy of Certificate of Incorporation (iii) A copy of Authorization/Power of Attorney issued by the Company (backed by the resolution of Board of Directors) in favour of the individual to sign the tender on behalf of the company and create liability against the company. (iv) All other documents in terms Para 10 of the Tender Form (Second Sheet) above.
(f) LLP (Limited Liability Partnership): (i) A copy of LLP Agreement (ii) A copy of Certificate of Incorporation (iii) A copy of Power of Attorney/Authorization issued by the LLP in favour of the individual to sign the tender on behalf of the LLP and create liability against the LLP. (iv) An undertaking by all partners of the LLP that they are not blacklisted or debarred by Railways or any other Ministry / Department of the Govt. of India from participation in tenders / contracts as on the date of submission of bids, either in their individual capacity or in any firm/LLP or JV in which they were / are partners/members. Concealment / wrong information in regard to above shall make the contract liable for determination under Clause 62 of the Standard General Conditions of Contract. (v) All other documents in terms of Para 10 of the Tender Form (Second Sheet). (g) Registered Society & Registered Trust: (i) A copy of Certificate of Registration (ii) A copy of Memorandum of Association of Society/Trust Deed (iii) A copy of Power of Attorney in favour of the individual to sign the tender documents and create liability against the Society/Trust. (iv) A copy of Rules & Regulations of the Society (v) All other documents in terms of Para 10 of the Tender Form (Second Sheet) above.
(iii) If it is NOT mentioned in the submitted tender that tender is being submitted on behalf of a Sole Proprietorship firm / Partnership firm / Joint Venture / Registered Company etc., then the tender shall be treated as having been submitted by the individual who has signed the tender. (iv) After opening of the tender, any document pertaining to the constitution of Sole Proprietorship Firm / Partnership Firm / Registered Company/ Registered Trust / Registered Society / HUF/LLP etc. shall be neither asked nor considered, if submitted. Further, no suo moto cognizance of any document available in public domain (i.e., on internet etc.) or in Railway's record/office files etc. will be taken for consideration of the tender, if no such mention is available in tender offer submitted. (v) A tender from JV shall be considered only where permissible as per the tender conditions. (vi) The Railway will not be bound by any change of power of attorney or in the composition of the firm made subsequent to the submission of tender. Railway may, however, recognize such power of attorney and changes after obtaining proper legal advice, the cost of which will be chargeable to the Contractor.
The tenderer whether sole proprietor / a company or a partnership firm / joint venture (JV) / registered society / registered trust / HUF / LLP etc if they want to act through agent or individual partner(s), should submit along with the tender, a copy of power of attorney duly stamped and authenticated by a Notary Public or by Magistrate in favour of the specific person whether he/they be partner(s) of the firm or any other person, specifically authorizing him/them to sign the tender, submit the tender and further to deal with the Tender/ Contract up to the stage of signing the agreement except in case where such specific person is authorized for above purposes through a provision made in the partnership deed / Memorandum of Understanding / Article of Association /Board resolution, failing which tender shall be summarily rejected. A separate power of attorney duly stamped and authenticated by a Notary Public or by Magistrate in favour of the specific person whether he/they be partner(s) of the firm or any other person, shall be submitted after award of work, specifically authorizing him/them to deal with all other contractual activities subsequent to signing of agreement, if required. Note: A Power of Attorney executed and issued overseas, the document will also have to be legalized by the Indian Embassy and notarized in the jurisdiction where the Power of Attorney is being issued. However, the Power of Attorney provided by Bidders from countries that have signed the Hague Legislation Convention 1961 are not required to be legalized by the Indian Embassy if it carries a conforming Appostille certificate.
Please submit your bank details i.e. Name of the Bank along with Bank Branch Code, Account Number, IFSC Code, and PAN Number.
Please furnish list of plant and Machinery available on hand own and proposed to be inducted own and hired to be given separately for the subject work.
Please furnish list of Works on hand indicating Description of Work, Contract Value, Approximate value of balance work yet to be done and Date of award.
Please furnish list of Works completed in last three financial years giving Description of Work, Organization for whom executed, approximate value of contract at time of award, Date of award and Date of Completion. Date of actual Start, Actual Completion and Final value of Contract shall also be given.
Please furnish list of personal, organization available on hand and proposed to be engaged for the subject work.
The tenderer whether sole proprietor / a company or a partnership firm / joint venture (JV) / registered society / registered trust / HUF / LLP etc if they want to act through agent or individual partner(s), should submit along with the tender, a copy of power of attorney duly stamped and authenticated by a Notary Public or by Magistrate in favour of the specific person whether he/they be partner(s) of the firm or any other person, specifically authorizing him/them to sign the tender, submit the tender and further to deal with the Tender/ Contract up to the stage of signing the agreement except in case where such specific person is authorized for above purposes through a provision made in the partnership deed / Memorandum of Understanding / Article of Association /Board resolution, failing which tender shall be summarily rejected. All tenderers ensure that this Para/Clause of GCC should be a part of Board of resolution and Power of attorney.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Rates are inclusive of all taxes/octroi, license fee, royalty charges etc. legally leviable by State, Central Govt. and/or any other local authority.
INDIAN RAILWAY STANDARD GERNERAL CONDITION OF CONTRACT is available on the Indian Railways website. Tenderers are requested to visit the website and be aware of the Terms and Conditions of GCC.
Security Deposit: The Security Deposit shall be 5% of the contract value. The Bid Security submitted by the Contractor with his tender will be retained/encashed by the Railways as part of security for the due and faithful fulfillment of the contract by the Contractor. Provided further that, if Contractor submits the Cash or Term Deposit Receipt issued from a Scheduled commercial bank of India or irrevocable Bank Guarantee Bond from a Scheduled commercial bank of India, either towards the Full Security Depositor the Part Security Deposit equal to or more than Bid Security, the Railway shall return the Bid Security, to the Contractor. Balance of Security Deposit may be deposited by the Contractor in cash or Term Deposit Receipt issued from Scheduled commercial bank of India or irrevocable Bank Guarantee bond issued from Scheduled commercial bank of India, or may be recovered at the rate of 6% of the bill amount till the full Security Deposit is recovered. Provided also that in case of defaulting Contractor, the Railway may retain any amount due for payment to the Contractor on the pending "on account bills" so that the amounts so retained (including amount guaranteed through Performance Guarantee) may not exceed 10% of the total value of the contract. The Irrevocable Bank Guarantee submitted towards Security deposit shall be initially valid up to the stipulated date of Maintenance period plus 60 days and shall be extended from time to time, depending upon extension of contract granted in terms of Clause 17A and 17B of the Standard General Conditions of Contract. Note: Security Deposit deposited in cash by the Contractor or recovered from the running bills of a Contractor or submitted by contractor as Term Deposit Receipt(s) can be refunded/returned to the contractor, in lieu of irrevocable Bank Guarantee bond issued from scheduled commercial bank of India, to be submitted by him, for an amount equal to or more than the already available Security Deposit, provided however that, in a contract of value less than Rs. 50 Crore, such refund/ return of the already available Security Deposit is permitted up to two times and in a contract of value equal to or more than Rs. 50 Crore, such refund / return of the already available Security Deposit is permitted up to three times.
The successful bidder shall have to submit a Performance Guarantee (PG) within 21 (Twenty one) days from the date of issue of Letter of Acceptance (LOA). Extension of time for submission of PG beyond 21 (Twenty one) days and upto 60 days from the date of issue of LOA may be given by the Authority who is competent to sign the contract agreement. However, a penal interest of 12% per annum shall be charged for the delay beyond 21(Twenty one) days, i.e. from 22ndday after the date of issue of LOA. Further, if the 60thday happens to be a declared holiday in the concerned office of the Railway, submission of PG can be accepted on the next working day. In all other cases, if the Contractor fails to submit the requisite PG even after 60 days from the date of issue of LOA, the contract is liable to be terminated. In case contract is terminated railway shall be entitled to forfeit Bid Security and other dues payable to the contractor against that particular contract, subject to maximum of PG amount. In case a tenderer has not submitted Bid Security on the strength of their registration as a Startup recognized by Department of Industrial Policy and Promotion (DIPP) under Ministry of Commerce and Industry, DIPP shall be informed to this effect. The failed Contractor shall be debarred from participating in re-tender for that work.
The successful bidder shall submit the Performance Guarantee (PG) in any of the following forms, amounting to 5% of the original contract value:- (i) A deposit of Cash; (ii) Irrevocable Bank Guarantee;(iii) Government Securities including State Loan Bonds at 5% below the market value; (iv) Pay Orders and Demand Drafts tendered by any Scheduled Commercial Bank of India; (v) Guarantee Bonds executed or Deposits Receipts tendered by any Scheduled Commercial Bank of India; (vi) Deposit in the Post Office Saving Bank; (vii) Deposit in the National Savings Certificates; (viii) Twelve years National Defence Certificates; (ix) Ten years Defence Deposits; (x) National Defence Bonds and (xi) Unit Trust Certificates at 5% below market value or at the face value whichever is less. Also, FDR in favour of FA&CAO (free from any encumbrance) may be accepted.
The following deduction will be done on the time of passing bill for payment: - 1 . 2% Income Tax on the total cost of the contract. 2. TDS: -1% CGST & 1% SGST or 2% IGST whichever applicable. Moreover, any other charges will be deducted from contractor's bill as per Railway board latest guidelines.
General Electrification work in connection with Miscellaneous Telecom Works- Standby master telephone, strengthening OFC media & S&T service building in place of PORTA hut, Miscellaneous Signalling Work for raising the sectional speed 130 KM/H in Rampur-Lalkuan Section, Extension of relay room at Kashipur station, Interlocking of 06 nos. LCs having restricted visibility in various sections, Provision of 2nd loop line at Aliganj station and Construction of electric loco trip shed at Lalkuan yard of Izzatnagar Division.
IZN-Elect-OT-11-2026
IZN-Elect-OT-11-2026
Open
Works - General
12 Months
Gorakhpur, Uttar Pradesh
₹0
₹1.4 L
2 Apr 2026
11 Mar 2026
19 Mar 2026
109 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 70,59,237.54 | ||
| — | — | — | Above/ 201427.50 Below/P | ||
| Supply and recessing/fixing of PVC Conduit pipe 25 mm (Medium) conforming to IS 9537/ Part III/1983 (Latest version) with accessories, junction box, bend etc including making chase, plastering/ clamping etc | — | 5350.00 | — | — | |
| — | — | — | Above/ 34850.00 Below/P | ||
| Supply and recessing/fixing of PVC Conduit pipe 25 mm (Medium) conforming to IS 9537/ Part III/1983 (Latest version) including supply of all accessories i.e., junction box, bend, brass screw & cup washer as per specification with suitable size M.S. clamp etc., complete in all respect as per direction of engineer incharge. | — | 1000.00 | — | — | |
| — | — | — | Above/ 7375.00 Below/P | ||
| Supply and Installation of Ceiling rose 3 plate as per IS No. 371/1999 (Latest Version) including connections, Testing and commissioning. | — | 500.00 | — | — | |
| — | — | — | Above/ 15362.10 Below/P | ||
| Supply and Erection of white finish single mounting cover plate with base frame suitable 12 module suitable for mounting of Modular type piano switches/ plug Socket, fan regulator and connection to wiring. | — | 78.00 | — | — | |
| — | — | — | Above/ 9317.88 Below/P | ||
| Supply and Erection of Modular Metal boxes concealed Boards suitable for mounting of 12 module white finish single mounting cover plate with Frame and Modular type piano switches/ plug Socket, fan regulators. Metal board boxes are to be concealed in wall. | — | 78.00 | — | — | |
| — | — | — | Above/ 9821.52 Below/P | ||
| Supply and Erection of white finish single mounting cover plate with base frame suitable 8 module suitable for mounting of Modular type piano switches/ plug Socket, fan regulator and connection to wiring. | — | 72.00 | — | — | |
| — | — | — | Above/ 5346.72 Below/P | ||
| Supply and Erection of Modular Metal boxes concealed Boards suitable for mounting of 8 module white finish single mounting cover plate with Frame and Modular type piano switches/ plug Socket, fan regulators. Metal board boxes are to be concealed in wall. | — | 72.00 | — | — | |
| — | — | — | Above/ 9233.51 Below/P | ||
| Supply and Erection of white finish single mounting cover plate with base frame suitable 3 module suitable for mounting of Modular type piano switches/ plug Socket, fan regulator and connection to wiring. | — | 143.00 | — | — | |
| — | — | — | Above/ 6058.91 Below/P | ||
| Supply and Erection of Modular Metal boxes concealed Boards suitable for mounting of 3 module white finish single mounting cover plate with Frame and Modular type piano switches/ plug Socket, fan regulators. Metal board boxes are to be concealed in wall. | — | 143.00 | — | — | |
| — | — | — | Above/ 140.40 Below/P | ||
| Supply & Erection of Modular Type switch blankimng set to fill the blank space white finished mounting cover plate complete in all respect. | — | 20.00 | — | — | |
| — | — | — | Above/ 48424.00 Below/P | ||
| Supply, Erection, Testing and Commissioning of Modular Type switch 6/10A (1-way) complete in all respect. | — | 800.00 | — | — | |
| — | — | — | Above/ 34030.60 Below/P | ||
| Supply, Erection, Testing and Commissioning of Modular type Plug socket outlet 2/3 Pin 10A complete in all respect. | — | 340.00 | — | — | |
| — | — | — | Above/ 24206.00 Below/P | ||
| Supply, Erection, Testing and Commissioning of Modular Type switch 16/20A (1-way) complete in all respect. | — | 196.00 | — | — | |
| — | — | — | Above/ 28002.52 Below/P | ||
| Supply, Erection, Testing and Commissioning of Modular type Plug socket outlet 5/3 Pin 20A complete in all respect. | — | 196.00 | — | — | |
| — | — | — | Above/ 3836.20 Below/P | ||
| Supply, Erection, Testing and Commissioning of Modular Type step type electronic fan regulator complete in all respect. | — | 20.00 | — | — | |
| — | — | — | Above/ 88200.00 Below/P | ||
| Supply of HRFR PVC insulated multi stranded copper conductor single core 1.5 Sq.mm cable conforming to IS 694 (Latest Version), and drawing in Laid (recessed /surface) M.S/PVC conduit pipe for wiring of point wiring/circuit wiring/sub main/ main as required, including connections, testing and commissioning. | — | 7350.00 | — | — | |
| — | — | — | Above/ 220200.00 Below/P | ||
| Supply of HRFR PVC insulated multi stranded copper conductor single core 2.5 Sq.mm cable conforming to IS 694 (Latest Version), and drawing in Laid (recessed /surface) M.S/PVC conduit pipe for wiring of point wiring/circuit wiring/sub main/ main as required, including connections, testing and commissioning. | — | 12000.00 | — | — | |
| — | — | — | Above/ 274852.50 Below/P | ||
| Supply of FRLS PVC insulated multi stranded copper conductor single core 4.0 Sq.mm cable conforming to IS 694 (Latest Version), and drawing in Laid (recessed /surface) M.S/PVC conduit pipe for wiring of point wiring/circuit wiring/sub main/ main as required, including connections, testing and commissioning. | — | 9750.00 | — | — | |
| — | — | — | Above/ 258751.50 Below/P | ||
| Supply of HRFR PVC insulated multi stranded copper conductor single core 6.0 Sq.mm cable conforming to IS 694 (Latest Version), and drawing in Laid (recessed /surface) M.S/PVC conduit pipe for wiring of point wiring/circuit wiring/sub main/ main as required, including connections, testing and commissioning. | — | 6650.00 | — | — | |
| — | — | — | Above/ 98020.00 Below/P | ||
| Supply of HRFR PVC insulated multi stranded copper conductor single core 10.0 Sq.mm cable conforming to IS 694 (Latest Version), and drawing in Laid (recessed /surface) M.S/PVC conduit pipe for wiring/sub main/main as required, including connections, testing and commissioning. | — | 1000.00 | — | — | |
| — | — | — | Above/ 110707.29 Below/P | ||
| Supply of LED tube light fitting 20 Watt, 1200 mm long, colour temperature 6500K, Lamp shell material- Polycarbonate, Lamp efficiency-100 Lm/W, LED tubelight life of 25000 hours predicted as per TM21 report on data Obtained as per test conducted for 6000 hrs as per LM80, operating voltage range 100-300 volt, Replacement warranty-5 years. and Fixing, testing & commissioning including making of hole in the wall by drill machine for fixing for fitting with 2 no. rowal plugs, 02 no. screws and wiring connection with existing ceiling rose. | — | 521.00 | — | — | |
| — | — | — | Above/ 76973.00 Below/P | ||
| Supply, Installation, Testing & commissioning of SPN MCB Distribution board 8 way double door made with 1.2 mm thickness CRCA sheet fully powder coated of 50-70 micron with 01 No. MCB 02 pole 40 Amperes 10 KA 230 V as incoming and 06 Nos MCB of 6-20 Amp single pole 10 KA, 230 volts as outgoing complete in all respect including connection as required. | — | 31.00 | — | — | |
| — | — | — | Above/ 2098.04 Below/P | ||
| Supply, Installation, Testing and Commissioning of SPN MCB Distribution Board 4 Way double door made with 1.2 mm thickness CRCA sheet fully powder coated of 50-70 micron with 01 No. MCB 02 Pole 40 Amp 10 KA 230V as incoming and 02 Nos. MCB of 6-25 Amp single pole 10 KA 230 Volt as outgoing complete in all respect including connection as required. | — | 2.00 | — | — | |
| — | — | — | Above/ 279791.10 Below/P | ||
| Supply, Fixing, connecting, testing & commissioning of Exhaust fan, wall mounting 380 mm sweep as per IS.2312 suitable for 220-230 volts, 50 Hz, AC supply, complete in all respect as per direction of engineer incharge. | — | 85.00 | — | — | |
| — | — | — | Above/ 229471.90 Below/P | ||
| Supply of BLDC Fan with Brush less DC Motor 1400 mm sweep, 35 watt, power factor 0.9, Air delivery 230 Cubic meters per minute, three Nos aluminium blade, blade thickness 1.1 mm, double ball bearing, BEE 5 Star rated, ISI marked, as per IS:374:2019 latest with electronic regulator warranty of ceiling fan 60 Months and Installation, connection with Twin core PVC insulated flexible copper conductor FRLS cable of size 14/0.193 mm (0.41 Sq. mm) testing and commissioning of 1200/ 1400 mm sweep AC ceiling fan/Air Circulator (on the installed CI/MS Box) including earthing. | — | 98.00 | — | — | |
| — | — | — | Above/ 2784.74 Below/P | ||
| Supply and fixing of single door box inside dimensions size 300 x 300 x 120 (WxHxD), fabricated from 1.6 mm CRCA sheet steel, powder coated, hinged door, gasket, cable gland plate 2 mm thick with five no, holes provided at bottom, cam locking arrangement with complete TPN 100 Amp copper busbar fixing with insulator and complete connection of incoming & outgoing cables. | — | 2.00 | — | — | |
| — | — | — | Above/ 311661.00 Below/P | ||
| Digging of trench of all kinds of soil up to the depth of 750 mm and 350 mm wide for laying of cable with supply and placing of second-class bricks approx 10 bricks per mtrs. & refilling of cable trench with solid earth consolidating by ramming by 270 mm above the surrounding level over trench as per IS: 1255/1983. | — | 6300.00 | — | — | |
| — | — | — | Above/ 72450.00 Below/P | ||
| Laying and connecting of XLPE 1100 volts grade (L.T.) cable of suitable size cable in excavated cable trench of above item as per IS:1255/1983 (latest version). Note :- XLPE (L.T.) cable will be supplied by the Railway at site. | — | 12600.00 | — | — | |
| — | — | — | Above/ 489955.48 Below/P | ||
| Supply, erection and testing of hot dip galvanized tapered octagonal pole of 5.0 Mtrs. long top dia 70 mm, bottom dia 130 mm, base plate length) (4 x M16 x 600 mm), anchor plate thickness 3 mm with hot dip 2 dia sleeve. (Octagonal IS: 2629 or latest.) Note: 1. Galvanized thickness of pole should be minimum 65 microns and test mm, sheet thickness 3 dimension (L x B x T) 200 mm x 200 mm x 12 mm & foundation bolts size (No. x dia x galvanized detachable type single arm bracket made by 48.3 mm outer dia 300 mm long with 32 mm outer pole shall confirm to report to be submitted by the contractor at the time of supply.2. Octagonal pole shall have flush door arrangement and suitable size & length of cable connecting plate for incoming and outgoing cables as per standard. | — | 74.00 | — | — | |
| — | — | — | Above/ 71115.80 Below/P | ||
| Supply, erection and testing of hot dip galvanized tapered octagonal pole of 5.0 Mtrs. long top dia 70 mm, bottom dia 130 mm, base plate length) (4 x M16 x 600 mm), anchor plate thickness 3 mm with hot dip 2 dia sleeve. (Octagonal IS: 2629 or latest.) Note: 1. Galvanized thickness of pole should be minimum 65 microns and test mm, sheet thickness 3 dimension (L x B x T) 200 mm x 200 mm x 12 mm & foundation bolts size (No. x dia x galvanized detachable type Double arm bracket made by 48.3 mm outer dia 300 mm long with 32 mm outer pole shall confirm to report to be submitted by the contractor at the time of supply.2. Octagonal pole shall have flush door arrangement and suitable size & length of cable connecting plate for incoming and outgoing cables as per standard. | — | 10.00 | — | — | |
| — | — | — | Above/ 158767.56 Below/P | ||
| Making trench of size 300 mm x 300 mm x 1000 mm and Casting/grouting of pre- cast foundation CC 1:2:4 block size 300 mm x 300 mm x 1000 mm grouting with 20 mm size stone aggregate with cement & coarse sand including supply, fixing and removing all firm work and finishing exposed surface including grouting and holding down-M 16x 450 mm- 4 Nos bolts in cement block as per requirement of pole base plate of size 200x200x12 mm and supply & fixing Double Walled Corrugated (DWC DPDE Duct Pipe, size 90/76 mm, confirming to IS:14930 (Part-II) 0.75 meter length in the centre of cement concrete block for cable entry and fixing properly with all labour, material, cement etc. complete in all respect as per direction of engineer in-charge at site. | — | 84.00 | — | — | |
| — | — | — | Above/ 108412.86 Below/P | ||
| Supply of Led Luminaire street light, Power 90 Watt, Rated voltage 240 V AC 50 Hz LED luminaire as per IS:10322/Part 5/Section 3/2012 latest, IS: 16107 (Part 2/Sec 1):2012 latest, and LED module as per IS: 16103(Part-2)/2012 - Type-3 latest, IP-66 as per IS:10322 (Part 1):1982 latest. and Fixing connecting testing and commissioning of LED street light fitting including supply and connection with twin core PVC insulated flexible copper conductor cable of size 1.5 sq.mm complete in all respect as per direction of engineer incharge at site. | — | 114.00 | — | — | |
| — | — | — | Above/ 430810.50 Below/P | ||
| Supply, Fixing, connecting, testing & commissioning of 60/63 Amps CLS Panel confirming to RSDO specification No. TI/SPC/PSI/CLS/0020 (12/02) with A& C slip No 1 to 4 or latest. Preferred make:-CORE approved venders, Complete in all respect. | — | 15.00 | — | — | |
| — | — | — | Above/ 586316.50 Below/P | ||
| All work pertaining to Horizontal Directional Drilling (HDD)/Boring and trench less cabling. It includes supply, transportation and insertion of self lubricated HDPE pipe and laying of cable in boring under the track/road by using different sizes of pipes depending on total number of cables will be crossed. The depth of horizontal boring should be minimum 3.0 Mtrs from rail flange/road level. This item will be used for track crossing of running lines. a). By using self- lubricated HDPE pipe of minimum 107.40 mm inner dia and 125 mm outer dia in the bore and the laying of cables in the bore under the track/road.(HDPE Pipe shall be supplied by contractor). | — | 550.00 | — | — | |
| — | — | — | Above/ 70173.96 Below/P | ||
| Supply, making testing & commissioning of pipe earthing arrangement with GI pipe 'B' class, 40 mm dia 4.50 mtrs, long including accessories & providing masonry enclosure with cover plate of 16 SWG M.S. having locking arrangement watering pipe, salt, charcoal etc. as per Drg. NO. DRM / Elect/IZN /1-89 to achieve earth resistance less than 10 ohms and connecting the equipment with 6 SWG G.I. wire as per site requirement. Earthing shall be done on the basis of code of practice for earthing as per IS: 3043/1987. | — | 51.00 | — | — | |
| — | — | — | Above/ 57000.00 Below/P | ||
| Supply, making testing & commissioning of chemical earthing arrangement to achieve earth resistance less than 2.5 ohms and connecting the equipment complete as per site requirement. Earthing shall be done on the basis of code of practice for earthing as per IS: 3043/1987. | — | 20.00 | — | — | |
| — | — | — | Above/ 79140.00 Below/P | ||
| Supply, Installation, testing and commissioning of Split Air conditioner 1.5 ton capacity, inverter type, copper coil, 5 star rated, suitable for operation on 230 volts, 50 Hz, AC supply, conforming to IS:1391 latest, Warranty of machine - 01 year, including installation of stabilizer and wall/floor mounting stand of outdoor unit complete in all respect. | — | 2.00 | — | — | |
| — | — | — | Above/ 8000.00 Below/P | ||
| Supply of Automatic Voltage stabilizer 4.0 KVA capacity, copper winding, Single phase 120 volts to 280 Volts with digital voltmeter, wall mounting type conforming to IS: 8448:1989 latest, having warranty of 36 months. | — | 2.00 | — | — | |
| — | — | — | Above/ 84960.00 Below/P | ||
| Supply and fixing of suction and discharge copper pipe with insulation | — | 80.00 | — | — | |
| — | — | — | Above/ 14400.00 Below/P | ||
| Supply and fixing of Air Conditioner PVC drain pipe in concealed manner complete in all respect. | — | 80.00 | — | — | |
| — | — | — | Above/ 4833.54 Below/P | ||
| Supply, installation, testing & commissioning of Metal plug & socket board 20/32 Amps enclosure with 2 pole and earth metal plug & socket for incorporating SP MCB 20/32 Amps complete with fitted MCB 'C' curve. Board should be fixed in the wall including cutting of wall and making good with cement mortar as per direction of engineer in-charge at site. | — | 6.00 | — | — | |
| — | — | — | Above/ 179134.80 Below/P | ||
| Design, supply & making of double door feeder pillar box made of 2.0 mm thick cold rolled steel sheet of size 600 mm (L) x 450 mm (W) x 300 mm (D) with provision of water proof, hinged door, suitable locking arrangements, proper hole in the bottom for cable entry (incoming & out going cables 05 No), suitable of MS channel of size 75 mm x 40 mm x 4.8 mm should be fixed across the panel for grouting on the foundation, earthing terminals and panel shall be powder coated (paint) greenish grey shade with TPN copper bus bar 400 Amps - 01 Set, including Supply, fixing, connecting, testing & commissioning of MCCB-100 Amps 04 pole - 01 No & MCB SP&N 32 Amps - 02 Nos in the feeder pillar box. Providing and making foundation for double door feeder pillar box (cubical type LT panel) in CC 1:2:4 with stone aggregate of [Size 1220 mm high x 800 mm length and 600 mm width (610 mm under the earth & 610 mm above the earth) with fine finish to exposed surface, two coats white washing including excavation of foundation, making proper size hole for incoming and outgoing cables. Grouting of holding down bolt in CC (size of bolt 150 mm long 16 mm dia) included fixing of subdistribution box on CC foundation as per direction of Engineer in charge at site. | — | 13.00 | — | — | |
| — | — | — | Above/ 165315.50 Below/P | ||
| SITC of VTPN distribution board 4 way as per IEC 61439-3, suitable for flush mounting and surface mounting, 100 Amps copper bus bar for each phase with two neutral bar, two earth bar and cable ties for cable management, fully insulated bus bar & shrouded Neutral bars, Improved Pan assembly for ease of installation, refitted masking sheet, with provision for TPN MCB as incomer and SP MCB's outgoing, IP 43 with metal door with fixing & connecting. Along with MCCB's 4 pole 100 Amps, Breaking capacity 25 KA, rated voltage 415V 50 Hz AC supply conforming to IS: 13947 (Pt.1&2)/IEC60947- 1&2 - 01 No, MCB 'C' curve, no. of poles - two pole, rated voltage 415 V AC, rated current Amps: 63 Amps, rated short circuit current capacity 10 KA rated frequency: 50 Hz, AC conforming to IS:60898-1/2002 - 03 Nos and Single pole MCB 16 Amps, 'C' curve, 10 KA, ISI marked conforming to IS/IEC 60898-1-2002- 10 Nos. | — | 7.00 | — | — | |
| — | — | — | Above/ 20182.50 Below/P | ||
| Dismantaling of existing erected MS tubular pole/ Rail pole including removing of cross arm bracket with insulator, overhead conductor as per direction of Engineer in charge at site. (1 span=1 job) Note: Dismantled MS tubular/Rail pole & other related material (cross arm bracket with insulator, overhead conductor etc.) to be handed over to the concerned engineer incharge at site. | — | 30.00 | — | — | |
| — | — | — | Above/ 126100.00 Below/P | ||
| Design, Manufacturing, supply, installation, connecting & commissioning of cubical type LT. switch board panel, fabricated with CRCA sheet of 1.6 mm thick with 9 tank process powder coated CPRI approved specification, IP-44. Supply, fixing, testing & commissioning of main TPN copper bus bar (600 Amps) - 02 sets in the panel including supply & fixing of CT's and sub copper bus bar to connecting outgoings MCCB to main copper bus bar of suitable size with aluminium lugs of all incoming side. All MCCBs with outgoing cable will be connected with aluminium lugs through cable glands, wiring of meter & indication lamp etc., as per required with suitable size of copper conductor cable. (Note: The following material will be Supply, fixing & connecting in the cubical type LT switch board panel including testing & commissioning) 1. Incoming Main MCCB 250 Amps, 04 poles with thermal braking capacity 25 KA, conforms to Ics- 100% Icu as per IEC 60947-2, adjustable thermal setting 0.7 x1x In suitable for 415 volts 50 Hz, AC supply - 01 No. 2. On load Manual Change with 63 Amps. 04 pole, complete with all respect-1 No. 3. Outgoing MCCB 63 Amps, 04 poles, braking capacity 25 KA-03 No. 4. Outgoing MCCB 25-32 Amps. 04 poles, braking capacity 18 KA. - 03 No. 5. RYB LED Indication lamps for incoming & outgoing feeders-18 No. 6. LED Multifunction Meter, accuracy class 1 with RS485. Input voltage measurement range 170-520 VAC. Aux supply 90-300 VAC. flush mounted 96 x 96 mm. Parameters Model A V, A, F, PF KW, KVA, KVAR. KWh, KVAh, kVARh. Runhours. On hours, Intrrupts, RPM. %Unbalance (VA) Phase angle, THD-06 Set. All MCCB & COS shall be of reputed make. | — | 1.00 | — | — | |
| — | — | — | Above/ 164767.50 Below/P | ||
| "Supply, fixing, connecting, testing and commissioning of LED Pit Light luminaire of 16 Watt complete with Power Factor> 0.9, input Voltage 48 V AC ±10%, Frequency Range 50 Hz, LED matrix - 12 LED matrix, approximate light output 1300-1400 lumens, LED Driver- High brightness driver system. Source PWM constant current, Reverse polarity protection, Short circuit protection, Open circuit protection, Material and insulation of driver Fire retardant material (ABS & Polycarbonate). Diffuser-P12 prismatic polycarbonate & toughened glass. (Juction temperature) Less than 90 degree centigrade of each LED after continuous operation of 12 hours. The whole luminaire fixture shall be provided with high impact resistance i.e. IK10. The whole luminaries fixture shall ensure tightness level of IP67 and all accessories of luminaries shall be pre wired upto the terminal block and the connecting lead wire shall be 3 core (phase, neutral & earth), PVC insulated of suitable size and minimum 1.0 metre long, Luminaire shall be locking & mounting arrangement. The approximate dimension of luminaire shall be 290 mm lung, 210 mm width and 72 mm deep, Fixing, connecting, testing and commissioning on the washing pit column with the help of with the help of G.I.Strip clamp and bolt fastener and anti theft arrangement of LED washing pit light including with all material as per direction of engineer in charge at site. Note :-LED fitting should be guarantee for a period of five year." | — | 50.00 | — | — | |
| — | — | — | Above/ 186042.00 Below/P | ||
| "Supply, Fixing, connecting, testing and commissioning of LED Catwalk Light luminaire of 22 Watt complete with Power Factor > 0.9, input Voltage 48 V AC ±10%, Frequency Range 50 Hz, LED matrix - 15 LED matrix, approximate light output 1600-1700 lumens, LED Driver- High brightness driver system, Source PWM constant current, Reverse polarity protection, Short circuit protection, Open circuit protection, Material and insulation of driver Fire retardant material (ABS & Polycarbonate), Diffuser- P12 prismatic polycarbonate & toughened glass, (Juction temperature) - Less than 90 degree Centigrade of each LED after continuous operation of 12 hours, The whole luminaire fixture shall be provided with high impact resistance i.e. IK10, The whole luminaire fixture shall ensure tightness level of IP67 and all accessories of liminaire shall be pre wired upto the terminal block and the connecting lead wire shall be 3 core (phase, neutral & earth), PVC insulated of suitable size and minimum 1.0 metre long. Luminaire shall be provided with suitable mounting arrangement and shall be suitable for semi flush/fully flush/surface mounting and locking arrangement The top cover of the luminaire shall be fitted with allen screws to avoid theft. The approximate dimension of luminaire shall be 320 mm long, 210 mm width and 72 mm deep. Fixing, connecting, testing and commissioning on the washing pit column with the help of with the help of G.I. Strip clamp and bolt fastener and anti theft arrangement of LED washing pit light including with all material as per direction of engineer in charge at site Note :-LED fitting should be guarantee for a period of five year." | — | 50.00 | — | — | |
| — | — | — | Above/ 80000.00 Below/P | ||
| Design, supply, installation, testing and commissioning of step down 3 KVA transformer wall/pole mounting type, input voltage single phase 220 volts± 10%, 50 Hz, AC supply and output voltage 48 volts± 10%, AC supply with volt meter, ampere meter, indication lamp. high & low voltage and short circuit protection including made by CRCA sheet 16 mm thick with hinged cover locking arrangement and making hole in the bottom for cable entry with cable glands and supply & fixing of cable connector terminals etc as required as per site requirement. | — | 4.00 | — | — | |
| — | — | — | Above/ 135595.80 Below/P | ||
| Supply and installation of RFID based Electronic Cable/pipe marker 22.5 Cms dia 1.5m Depth range, 10 Digits Hexadecimal ID code, 101.4 Khz frequency. | — | 45.00 | — | — | |
| — | — | — | Above/ 364180.97 Below/P | ||
| Supply of RFID Marker locator, 8000 Marker records, built in GPS Module, 1.5m depth range 4 X 20 Digits LCD display. (Inspection: Consignee). | — | 1.00 | — | — | |
| — | — | — | Above/ 491039.40 Below/P | ||
| Supply of LED High bay light, aluminium dia cast body round 150 watt, complete in all respect and Fixing, connecting, testing and commissioning of LED light fitting including supply and connection with twin core PVC insulated flexible copper conductor cable of size 1.5 sq.mm complete in all respect as per direction of engineer incharge at site. | — | 60.00 | — | — | |
| — | — | — | Above/ 111899.80 Below/P | ||
| Supply of 600 mm wall air circulator fan conforming to IS:2997 latest, complete in all respect and Installation, testing and commissioning of Air circulating fan 600 mm sweep, as per direction of site engineer. | — | 20.00 | — | — | |
| — | — | — | Above/ 74900.00 Below/P | ||
| Supply of cable junction box of size for lighting of size 100x100x75 mm,IP 66 (as per ISMEC 60529:2001 latest), fire 6 retardant class -FV-0(as per IS:11731 part-II) front lid cover with 4 numbers of quarter turn tool operated licking knobs with cable glands on junction box and fixing, testing commissioning of cable junction box of Size 100x100x75 mm on the wall /structure as per the direction of site supervisor. All material (bracket, clamp bolt fastener etc and other accessories) required for fixing shall be done by the contractor. | — | 100.00 | — | — | |
| — | — | — | Above/ 332799.14 Below/P | ||
| Design, Manufacturing, supply, installation, connecting & commissioning of cubical type LT. Switch Board Distribution panel fabricated with CRCA sheet of thickness minimum 2.0 nam with 9 tank process powder coated CPRI approved specification, IP-44. Supply, fixing, testing & commissioning of main TPN copper bus bar (400 Amps 40x10mm) - 01 set in the panel including supply & fixing of CT's and sub copper bus bar to connecting outgoings MCCB to main copper bus bar of suitable size with aluminium lugs of all incoming side. All MCCBs with outgoing cable will be connected with aluminium lugs through cable glands, wiring of meter & indication lamp etc., as per required with suitable size of copper conductor cable. (Note: The following material will be Supply, fixing & connecting in the cubical type LT switch board panel including testing & commissioning) 1. Incoming main MCCB 320 Amp., 04 pole, 36 KA,- 01 No. 2. On load changeover 250 Amps, 04 poles, 35 KA-01 No. 3. Outgoing MCCB 63 Amps, 04 poles, 18 KA-07 No. 4. Outgoing MCCB 200 Amps, 04 poles, 36 KA-01 No. 5. Supply & fixing of LED Multifunction Meter conforming to IEC 62053-21, Accuracy class -1.0 as per IEC 61036, three phase voltage, current, frequency, PF, kW, kVA, kVAR, kWh, kVAh, kVARh with communication, two output contact for trip, optional RS485, Auxiliary Supply: 85-300V AC/DC, Rated Current: 5Amp, Frequency Measurement: 20-200 Hz-9 No. 6. RYB LED Indication lamps for incoming & outgoing feeders-27 No. All MCCB & COS shall be of reputed make. | — | 1.00 | — | — |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
GCCApril2022correctionslip1to10.pdf
ATTACHMENT
HQJPO_Digginginthevicinityofcable_20.05.24_1.pdf
ATTACHMENT
TenderBookletCombinedSTWorkOT112026_compressed.pdf Tender Document
ATTACHMENT
GCCApril2022.pdf
ATTACHMENT
TenderBookletCombinedSTWorkOT112026_compressed.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .