| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L 1₹51.3 LAccepted-AOC SHOP NO 5 BACHAT BHAWAN UNA TEHSIL UNA HP 174303 | UNA | UNA | HP | 174303 | L 1 | Accepted-AOC AOC done | |
| 2 | L2₹53.7 L+₹2.5 L (4.84%)Rejected-Finance | L2 | Rejected-Finance L 2 | |
| 3 | L 3₹66.8 L+₹15.6 L (30.4%)Rejected-Finance H NO 199 W NO 6 NEAR OLD SDM OFFICE DISTT HAMIRPUR HP 177001 | HAMIRPUR | HAMIRPUR | HP | 177001 | L 3 | Rejected-Finance L 3 | |
| 4 | Rejected-Technical | - | Rejected-Technical Un- Responsive |
Tender Value
Refer Docs
EMD Value
₹90,000
Closing Date
8 Jul 2021, 5:00 pmClosed
Executive Engineer Electrical HPPWD Division Una
Executive Engineer Electrical HPPWD Division Una
Providing E.I. and Power wiring therein
2021_PWD_49260_1
C/O Govt. I.T.I. building Santohgarh at Mehatpur
Open Tender
Electrical Works
Item Rate
365 days
Una
Please refer Tender documents.
7 documents required · 7 mandatory
₹2,000
₹90,000
4 Oct 2022
30 Jun 2021
9 Jul 2021
30 Jun 2021
8 Jul 2021
30 Jun 2021
Amount
Wiring for light point / fan point / exhaust fan / call bell point with 1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit with modular switch, modular plates, suitable G.I. box and earthing the light point with 1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable as required.(Make :-Legrand (Arteor)/Anchor Panassonic (Vision/L&T (Entice)
Group C.
Wiring for twin control light point with 1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit with 2-way, 5/6 amps. modular switch, modular plates, suitable G.I. box and earthing the light point with 1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable as required.(Make :-Legrand (Arteor)/Anchor Panassonic (Vision/L&T (Entice)
Group C.
Wiring for power plug with 2x4 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 1 No.4 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable for earthing as required.(KEI/Anchor/L&T make)
Wiring for power plug with 4x4 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 2 No.4 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable for earthing as required.(KEI/Anchor/L&T make)
Wiring for circuit/sub-main with following size PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 1 No.HRFRLS/PVC insulated single core copper conductor cable of same size for earthing as required.(KEI/Anchor/L&T make)
2x1.5 Sq. mm.
2x6.0 Sq. mm.
2x10 Sq. mm.
Wiring for circuit / sub-main with 4x6 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 2 No.6 Sq.mm. (4x6+2x6) HRFRLS/PVC insulated single core copper conductor cable for earthing as required.(KEI/Anchor/L&T make)
Wiring for circuit / sub-main with 4x10 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 2 No.10 Sq.mm. (4x10+2x10) HRFRLS/PVC insulated single core copper conductor cable for earthing as required.(KEI/Anchor/L&T make)
Supplying and drawing following size of PVC insulated, heat resistant, flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in existing surface / recessed, Steel/PVC conduit as required.(KEI/Anchor/L&T make)
3x1.5 Sq. mm.
6x1.5 Sq. mm.
Supplying and fixing following rating Modular switch /socket in the existing switch box / cover plate including connections etc. as required.(Make :-Legrand (Arteor)/Anchor Panassonic (Vision/L&T (Entice)
S.P. 5/ 6 Amps one way Modular switch.
5 pin, 5/ 6 Amps Modular socket outlet.
Supplying and fixing stepped type Modular fan regulator on the existing modular box including making connections etc. as required.(Make :-Legrand (Arteor)/Anchor Panassonic (Vision/L&T (Entice)
Supplying & fixing Modular blanking plate on the existing modular metal box as required:-(Make :-Legrand (Arteor)/Anchor Panassonic (Vision/L&T (Entice)
Supplying and fixing G.I. Modular box of (140mmx78mmx50mm) size with modular plate and cover in recess including providing and fixing 5 pin 5/6 amps modular socket outlet and 5/6 amps, modular switch, connections etc. as required.(Make :-Legrand (Arteor)/Anchor Panassonic (Vision/L&T (Entice)
Supplying and fixing G.I. Modular box of (140mmx78mmx50mm) size with modular plate and cover in recess including providing and fixing 6 pin 15/16 amps modular socket outlet and 15/16 amps, modular switch, connections etc. as required.(Make :-Legrand (Arteor)/Anchor Panassonic (Vision/L&T (Entice)
Supplying and fixing bakelite batten/angle holder including connections etc. as required:- (SSK/Anchor make)
Supplying and fixing call bell / buzzer, suitable for D.C./A.C. single phase,230 volts complete as required:-
Supplying and fixing Ding-Dong / Electronic musical bell, suitable for D.C./A.C. single phase,230 volts complete as required:-(SSK/Anchor make)
Supplying and erection of wall mounted metal boards for switch gear mounting of suitable size, with permissible variation in size of plus minus 5mm, welded frame work made of M.S. angle iron 35 mm x 35 mm x 6 mm thick duly welded complete with 2.80mm thick M.S. sheet fixed with hinges as open able front, complete with locking arrangement including painting and bonding to the existing earth as required:-
Supplying and erection of following depth sheet metal cubical pedestal of suitable dimensions with plus-minus 5 cm variation made from (50 mm x 50 mm x 6 mm thick) M.S. angle iron frame, covered with 1.6 mm thick M.S. sheet duly welded on five sides & front side hinged, complete with locking arrangement with sufficient No. vertical and horizontal intermediate switchgear supporting members each of M.S. flat 50mmx6mm thick of suitable length duly welded. The cubical pedestal shall have cable entry box at one or two sides and 4 No. legs of 50mmx50mmx6mm thick M.S. angle iron each 60 cm long including, powder coated painting and bonding to the existing earth etc., the same shall be erected in the 1:2:4 cement concrete plat-form of suitable dimensions 15 cm high from ground level and 45 cm thick. The cubical pedestal shall be 15 cm from the top of cement concrete plat-form:-(EVA,Power & Control System,Supertech make or its equivalent approved make)The panel should be approved /Tested from the CPRI lab.& should confirmed to ISI: 64139
300 mm deep (nominal)
Supplying and fixing sheet metal bus-bar chamber suitable for 63 Amp. 415 volts capacity with 4 No. copper strip bus-bars each of length 300mm & cross-sectional area (16mmx3.17mm), enclosure made from 1.6 mm thick M.S. sheet having overall dimensions (380mmx350mmx150mm) nominal with all accessories including connections, earthing the body etc. as required:-(Legrand/Schneider/Siemens make)
Supplying and fixing sheet metal bus-bar chamber suitable for 100 Amp. 415 volts capacity with 4 No. copper strip bus-bars each of length 300mm & cross-sectional area (25.4mmx3.17mm), enclosure made from 1.6 mm thick M.S. sheet having overall dimensions (380mmx400mmx150mm) nominal with all accessories including connections, earthing the body etc. as required:-
Supplying and fixing copper strip bus-bars suitable for 100 Amp. 415 volts capacity 4 No. each of cross-sectional area (25.4mmx3.17mm),in the existing enclosure with all accessories including connections etc. as required:-
Supplying and fixing copper strip bus-bars suitable for 400 Amp. 415 volts capacity 4 No. each of cross-sectional area (38.10mmx6.35mm),in the existing enclosure with all accessories including connections etc. as required:-
Providing and fixing following rating, four pole, 415 volts, On-Load change over switch unit, panel mounting, front handle operation, including drilling holes in the cubical, making connections, etc. as required.(Legrand/L&T/ABB/Siemens make)
Providing and fixing following rating and breaking capacity MCCB in the existing cubical panel board including drilling holes in the cubicle panel, making connections, etc. as required.(Legrand/L&T/ABB/Siemens make)
100 Amp. -10 KA
315/400 Amp. -50 KA
Supplying and erection of 6 amps. to 32 amps. rating, 10 KA breaking capacity, 240 volts, 'C' curves, miniature circuit breaker of following poles in the existing MCB DB complete with connections etc. as required:- (Legrand/Hagger/ABB/L&T make)
Single pole. 6 Amps.Cat-A.
Single pole. 16 Amps.Cat-A.
Single pole. 25 Amps.Cat-A.
Supplying and erection of 40/50/63 amps rating, 10 KA breaking capacity, 240 volts, 'C' curves, miniature circuit breaker of following poles in the existing MCB DB complete with connections etc. as required:- (Legrand/Hagger/ABB/L&T make)
63 Amps. Cat-A.
Supplying and fixing following rating, double pole (single phase & neutral) 240 volts, residual current circuit breaker (RCCB), having a sensitivity current up to 300 miliampers in the existing MCB DB complete with connections, testing and commissioning etc. as required. (Legrand/Hagger/ABB/L&T make)
40 Amps. Cat-A.
63 Amps. Cat-A.
Supplying and fixing 20 Amps, 240 volts, SPN industrial socket outlet, 2-pole & earth, metal enclosed plug top, sheet steel enclosure, suitable to accommodate a 20 Amp SPN-MCB/DP, on surface or in recess, with chained metal cover for the socket outlet, complete with connections, testing and commissioning etc. as required. (Legrand/Hagger/ABB/L&T make)
Supplying and fixing of following way, single pole and neutral sheet steel MCB distribution board, 240 volts, on surface / recess, complete with tinned copper bus- bar, wire-set, neutral link, earth bar, din-bar, detachable gland plate, blanking plate, cable, identification labels interconnections, phosphatized and powder painted, including earthing etc. as required:- (Legrand/Hagger/ABB/L&T make)
Double door-4 way
Double door-8 way
Double door-12 way
Double door-16 way
Earthing with copper earth plate 600 mmx600 mmx 3 mm thick, including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. ( but without charcoal or coke and salt ) complete as required.
Extra for using salt and charcoal for G.I. or copper plate earth electrode complete as required.
Providing and fixing 25mm x 5mm copper strip on surface or in recess for earth connections etc. as required.
Providing and fixing M.V.danger notice plate of 200 mm x 150 mm made of mild steel at least 2 mm thick, and vitreous enameled white on both sides and with inscription in signal red color on front side as required.
Providing and laying of one No. aluminium conductor, PVC insulated and PVC sheathed, armoured/XLPE power cable, working voltage 1100 volts grade direct in ground; to be laid 1 meter below the ground level including excavation sand cushioning, protective covering and refilling the trench etc. of the required size:-(KEI/Havells or its equivalent make)
Armoured cable 500 sq. mm (3.5 core)
armoured cable 16 sq. mm (twin core)
armoured cable 10 sq. mm twin core)
armoured cable 6 sq. mm twin core)
Providing, laying and fixing of one No. aluminium conductor, PVC insulated and PVC sheathed, unarmoured/XLPE power cable, working voltage 1100 volts grade on surface etc. of the required size:-(KEI/Havells or its equivalent make)
Armoured cable 500 sq. mm (3.5 core)
Armoured cable 16 sq. mm (Twin core)
Providing and laying of aluminium conductor, PVC insulated and PVC sheathed, armoured/XLPE power cable, working voltage 1100 volts grade direct in ground in the same trench, in one tier horizontal formation to be laid 1 meter below the ground level including excavation and refilling the trench etc.as required, but excluding sand cushioning and protective covering etc. of required size:-(KEI/Havells or its equivalent make)
Armoured cable 500 sq. mm (3.5 core)
Providing and laying of aluminium conductor, PVC insulated and PVC sheathed, unarmoured/XLPE power cable, working voltage 1100 volts grade direct in ground in the same trench, in one tier horizontal formation to be laid 1 meter below the ground level including excavation and refilling the trench etc.as required, but excluding sand cushioning and protective covering etc. of required size:-(KEI/Havells or its equivalent make)
Unarmoured cable 10 sq. mm (twin core)
Unarmoured cable 10 sq. mm (four core)
Unarmoured cable 35 sq. mm (3.5 core)
Providing and installation of exhaust fan of following sizes in the existing opening, including making the hole to suit the size of the above fan, making good the damages, connections, testing and commissioning etc. as required:- (Usha - SPH Turbo HDEF 900 RPMISI or its Equivalent make)
Exhaust Fan, Light duty, (Domestic) 300 mm sweep
Exhaust Fan, Heavy duty, 300 mm sweep
Providing, Installation, testing and commissioning of ceiling fan without regulator, including wiring the down rods of standard length (up to 30 cm) with 16/0.20 mm twin twisted flexible, cotton braided, copper cable, including providing and fixing phenolic laminated sheet cover on the fan box and earthing etc. as required:- ( Usha-Technixplus BEE 3 Star rated model) or its equivalent make)
Ceiling Fan 1200 mm sweep, Category-A
Supplying and fixing Fan box of M.S.sheet with iron rod hook 12 mm.in place of junction box complete as required.
Supplying and fixing exhaust fan louver shutter for 300 mm.exhaust fan on the existing wall,painting etc, as required.(National or its equivalent make)
S/F Computer board comprising 3 No.5 amps.switch (Modular) and 3 No.3 pin 5 amps. Socket out let (Modular) and 1 No.12 Modular switch board with cover plate and 1 No.4 modular switch board with cover plate and 1 No.computer jack with shutter including connections etc,as required,complete in all respects.(Make :-Legrand (Arteor)/Anchor Panassonic (Vision/L&T (Entice)
Supplying and fixing LED digital mounting Ammeter 0 to 500 Amps.3 phase of size 96x96 sq.mm.flush mounting in the existing pannel complete with connections etc, as required.(L&T make Cat.No.WL131020OOOO or its equivalent make )
Supplying and fixing LED digital mounting Voltmeter 0 to 500 Amps.3 phase of size 96x96 sq.mm.flush mounting in the existing pannel complete with connections etc, as required.(L&T make Cat.No.WL132020OOOO or its equivalent make)
Supplying and fixing Coolio Fuzi LED Panel indicating set R,Y and B with 3 Nos.Kit kat (Neon type) to shown the three phase indicating in the existing panel complete with connections etc, as required.
Supplying and fixing C.T.coil 100/5 Amps.in the existing pannel complete with connections etc,as required.
Supplying and fixing of Rubber matt 1x2 mtrs.long 2.5 mm. thick (Jyoti) in the front of main panel etc,as required
Supplying and fixing shock trearment chart in main panel room on the existing wall etc, as required
Supplying and laying G.I.pipe of 40 mm. dia (Heavy duty) underground 1.00 mtr.below ground level for laying the wire/cable etc, as required
Supplying and laying G.I.pipe of 100 mm. dia (Heavy duty) underground 1.00 mtr.below ground level for laying the wire/cable etc, as required
Supplying and fixing indicating bell Red Green with 3 module box on the existing main door wall complete with connections etc, as required
Supply and fixing of IP40 Led fixture 40 W with Surface Mounted 4 Feet with Polycarbonate diffuser with aluminium housing minimum lumen output 4000 lumens with P.F.>0.95 with THD<10% ,CRI 80,Surge Protection 2 Kv with IP Protection of IP20 .The LEDs with minium life of 50000 burning hours.The LED shall be tested with LM80-08 standard with Useful life of 50000 Hrs at L70 with five years warranty . The LEDs used in the luminaire shall have CCT of ANSI Bin 5700 K with CRI of minimum 80. LEDs used must be tested as per EN62471 for Photobiological Safety of humans. The Input voltage range shall be 150V to 270V . Driver Output voltage shall be less than SELV Limits for safe operation and maintenance.Wipro Cat. No LL24-541-XXX-57-XX or Equivalent in Philips : BN308C LED40S-6500 L120 PSU WH or Trilux:TRL-X F OTA 4000-857 ET
Supply & fixing of IP20 linear Led fixture 20 W with connection Suspended Mounted 4 Feet having PMMA diffuser with extruded aluminum housing minimum system lumen output 2100 lumens P.F.>0.95 with THD<10% ,CRI 80,Surge Protection 2 Kv with IP Protection of IP20 .The LEDs with minium life of 50000 with five years warranty . The LEDs used in the luminaire shall have CCT of ANSI Bin 5700 K with CRI of minimum 80. LEDs used must be tested as per EN62471 for Photobiological Safety of humans. The Input voltage range shall be 150V to 270V . Wipro Cat. No LM34-251-XXX-57WCG1 or Equivalent in Philips : SP781 X LED27S-6500 PSU W6L112 OD SI or OSRAM.
Supply of 10W 300mm L Connector Suitable for connecting linear fixture in L Shape complete with connections etc,as required.Wipro Cat.No.LM34-930300L57WCG1/Philips/Trilux/LT make
Supply & fixing of 32W 4ft High efficiency Linear suspended luminaire with Edge lit optics derived from Reflector+ Light guide plate+Diffuser configuration. CRI>80, IP20, Ambient temp-0 to 45DegC, Driver efficiency>85%, THD<10%, CCT- 5700K, 50,000 hrs @ L70 life, Powerfactor>0.95, Surge protection-2 kV .Voltage operated driver with range 150-270V AC and Safety Extra Low Voltage Safe level<60V DC as per IEC standard. Luminaire lumen ≥ 2743 lm. Wipro Cat. Code : LM77-441-XXX-57-V1 or Equivalent in Philips or Osram.
Supply & fixing of IP20 Round Ring type decorative suspended fixture 35 watts having system lumen efficacy of 85 lumen/watt. Housing made up of extruded Aluminum powder coated in White (RAL9003)/Black(RAL9005) with High efficiency, non-yellowing PMMA diffuser having dia of 600 mm having CCT : 5700K. Wipro Cat. Code : LM23OR-621-XX57-XW or Equivalent in Philips or Trilux or OSRAM.
Supply & fixing of Suspended mounted cylindrical led downlighter 10W Suspended Fixture having inset clear glass diffuser with extruded aluminium black housing minimum lumen output1000 lumens P.F.>0.95 with THD<10% ,CRI 80,with beam angle 36degree .The LEDs with minium life of 50000 The LEDs used in the luminaire shall have CCT of ANSI Bin 4000 K with CRI of minimum 80. LEDs used must be tested as per EN62471 for Photobiological Safety of humans. The Input voltage range shall be 150V to 270V . .Wipro Cat. : LD30-101-36W-40-PS or Equivalent in Philips and Osram.
Supply and fixing of 2ft Led Batten 10 W surface mounted with polycarbonate diffuser and with extruded aluminum housing/polycarbonate housing minimum lumen output 1000 lumens P.F.>0.95 with THD<20% ,CRI 80,Surge Protection 2 Kv with IP Protection of IP20 .The LEDs with minium life of 50000 with five years warranty . The LEDs used in the luminaire shall have CCT of ANSI Bin 65000 K with CRI of minimum 80. LEDs used must be tested as per EN62471 for Photobiological Safety of humans. The Input voltage range shall be 150V to 270V . Driver Output voltage shall be less than SELV Limits for safe operation and maintenance.Wipro Cat. NoLL20-111-XX-65NE3 or Equivalent in Philips : BN 021 LED10S- 6500 PSU GR S1 or Trilux:TRL-X F OTA 2000-857 ETor LT
Supply and fixing of led fixture 18 W LED Surface Mounted Downlighter Round Shape with minimum system lumen efficacy of 90 lm/W with and P.F.>0.95 with THD<20% ,CRI 80.The LED shall be tested with LM80-08 standard with Useful life of 50000 Hrs at L70 with five years warranty .. The LEDs used in the luminaire shall have CCT of ANSI Bin 6000 K with CRI of minimum 80. LEDs used must be tested as per EN62471 for Photobiological Safety of humans. The Input voltage range shall be 150V to 270V .Fixture have Surge Protection 2kV .Driver Output voltage shall be less than SELV Limits for safe operation and maintenance.Wipro Cat. No LD80-171-XXX-60-SM or Equivalent in Philips: SM251C LED20S- 6500 PSU WH or Trilux :Ambiella IND D LED1000-860 ET 01 ET or LT :
Providing and fixing MCCB four pole 32 amps to 63 amps.rating and 18 KA breaking capacity 415 volts AC.supply 50 HZ four pole DU 100 D type in the existing enclosure including making connections etc,as required. (L&T/Legrand/ABB/Siemens make)
Providing and fixing MCCB enclosure for DU 100 D/DU MCCB following rating on the existing board complete as required.(L&T/Legrand/ABB/Legrand make)
Supplying and fixing LED Lamp 9 watts 6500 K E-27 ,900 Lumens 240 volts AC.supply 50 HZ in the existing batten holder,pendent holder,wall bracket & bulk head fitting etc, as required.(Tisva cat. No.AL946611X/Panasonic/Philips make)
Supplying and fixing of Bulk head fitting LED 10 watts and it should be compatible with specifications i.e.Power factor >0.9,Harmonic distortion <10% & efficacy >100 Lumen per watts,CRI >80 ,6500 K suitable for input voltage 220-240 Volts,50 HZ, Length 232x Width 105x Height 50 mm size complete with connections etc,as required.(Panasonic Ellipto Code No.PBHM01107/Philips/ Jaquor/Tisva make )
Providing and fixing DLP U-PVC adaptable trunking system and accessories 80X50 mm.on existing wall at required height from floor level including fixing partition chip,flexible cover,internal angle,external angle,flat angle,centre tap complete with end cap etc,as required.( Legrand Cat.No.010412 or its equivalent make)
Providing and fixing DLP U-PVC adaptable trunking system and accessories 80X50 mm.on existing wall at required height from floor level including fixing flexible cover,internal angle,external angle,flat angle,centre tap complete with end cap etc,as required.( Legrand Cat.No.010412 or its equivalent make)
Providing and fixing DLP U-PVC adaptable trunking system and accessories 105x50 mm.on existing wall at required height from floor level including fixing lexible cover,internal angle,external angle,flat angle,centre tap complete with end cap etc,as required.( Legrand Cat.No.010422 or its equivalent make)
Providing and fixing DLP U-PVC adaptable trunking system and accessories 195X50 mm.on existing wall at required height from floor level including fixing partition chip,flexible cover,internal angle,external angle,flat angle,centre tap complete with end cap etc,as required.( Legrand 010452 or its equivalent make)
Providing and fixing Internal angle adjustable from 80* to 100* on the DLP U-PVC trunking for making compact joint as required.( Legrand Cat.No.010602 or its equivalent make)
Providing and fixing External angle adjustable from 60* to 120* on the DLP U-PVC trunking for making compact joint as required.( Legrand Cat.No.010622 or its equivalent make)
Providing and fixing 90* Flat angle on the corner of DLP U-PVC 80x50 mm.trunking for making compact and good looking joint as required.( Legrand Cat.No.010767 or its equivalent make)
Providing and fixing 90* Flat angle on the corner of DLP U-PVC 105x50 mm.trunking for making compact and good looking joint as required.( Legrand Cat.No.010785 or its equivalent make)
Providing and fixing 90* Flat angle on the corner of DLP U-PVC 150x50 mm.trunking for making compact and good looking joint as required.( Legrand Cat.No.010789 or its equivalent make)
Providing and fixing Flat junction for to tap - off to a branch smaller than 50x105 mm. as required.(Legrand Cat.No.010732 or its equivalent make)
Supplying and fixing 4.0 mtrs.2 stepped Decorative pole made of Galvanised mild steel tubes with cast aluminium embellishments.The pole are primer coated and painted with polyurethane paint.The pole has a service window at the bottom comprising four way 25 amps connector terminal and a MCB.Pole can be mounted with four numbers Anchor bolts as per foundaation.Pole make :-Twinkle LuxMax-SP-140-400-4 mtr.or its equivalent make
Supplying and fixing Post top lantern LED 90 watts made of spun aluminium housing with sturdy bracket with power LED's are mounted directly on extruded aluminium heat sinks.A UV stabilized PC/PMMA diffuser is provided for glare free lighting with high visual comfort.input voltage AC-100-270,FREQUENCY 50~60HZ,Power factor 0.950,efficacy 100 Lum/W,CRI 80,THD 10% LIFE 50000 H with five years warranty ..Colour temperature NW 4000K.(Twinkle LuxMax-PT-157-H-CR Post top or its equivalent make
S/F of 2.0 ton split type air conditioner Hot & cold or its equivelent make & model 4 star rating-2 virus safe fittrer,triple filter,E-saver mode.Quit mode,white display,auto clean.Anti Bacteria filter jet cool ON/OFF timer,sleep mode compressor cordless remote complete in all respects or any other equivelent make as per Voltas comprising to ISI with latest amensment suitable to operate on 230/240 volts +/- 10% AC.supply capable to perform the function of cooling dehumidification air circulation,ventilation and fitting in the size of nominal cooling capacity complete with 5 KVA automatic voltage stabilizer Microtek model EM5170+ confiming to ISI specifications.The stabilizer should have high voltage trip and MCB high low voltage trip and time relay complete in all respects.inluding drain pipe 20 mm.dia approximatelly 3 mtrs.long,2 No.copper pipe with insulator for inlet and outlet approximatelly 3 mtrs.long and M.S.power coated frame/stand for errection of out door unit of split type A.C.including carriage of material with in all leads & lifts. (Voltas Make Invertor 4 Star Model No.Voltas SAC 244DZV(R-410) or its equivalent make)
Kalra Hardware and Electric Store
SHARMA ELECTRICAL CO.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .