Tender Value
₹12.2 L
EMD Value
₹12,200
Closing Date
27 Aug 2020, 2:00 pmClosed
SE/O/THIRUVALAM
EB KOOT ROAD, 230 KV SS CAMPUS, THIRUVALAM - 632 515.
AMC OF HOSUR 230 KV SS OF THIRUVALAM OPERATION CIRCLE FOR A PERIOD OF SIX MONTHS FROM THE DATE OF COMMENCEMENT OF WORK.
2020_EB_174888_1
E 80
Open Tender
Electrical and Maintenance Works
Works
180 days
Hosur
please refer tender document
2 documents required · 2 mandatory
₹0
₹12,200
Yes
17 Sept 2020
7 Aug 2020
28 Aug 2020
7 Aug 2020
27 Aug 2020
7 Aug 2020
7 Aug 2020 - 27 Aug 2020
Amount
Deweeding of SS yard (regular maintenance) SS Area
Clearing of scrub jungle (Other than SS Equpiment Yard area)
a) To remove birds nest and clean the tower in the SS premises in 230 KV tower (3 x 12)
b) To remove birds nest and clean the tower in the SS premises in 110 KV tower (5 x 12)
a)Transport of oil drums with oil from store room to SS yard and back Up to 100 Mtrs.
b) Transport of oil drums with oil from store room to SS yard and backf for Every additional 100 Mtrs.
a) Transport of Trolley mounted Aluminium Ladder from shed to the yard /work spot and back for Ladder of height up to 20 feet
b) Transport of Trolley mounted Aluminium Ladder from shed to the yard /work spot and back for Ladder of height above 20 feet
c) Transport of Trolley mounted Aluminium Ladder from shed to the yard /work spot and back for Ladder of height above 20 feet without trolley
To carry LC accessories (discharge rods, ladder below 20 feet, red flags etc.,) from stores to work spot/yard and back
To carry Tools and Plants (Pliers, screw drivers, spanners, lifting devices etc.,) Scientific instruments (megger, Voltmeter, Ammeter etc.)
a) 230 KV Breaker Cleaning outer surface
b) 110 KV Breaker
c) 33 KV and 11 KV
a) Cleaning of outer surface (bushings, Conservator Tank OLTC, Cooling (fins, Fans, Pipe lines etc.) in 230 KV /110 KV Auto Transformers(3 x 12)
b) Cleaning of outer surface (bushings, Conservator Tank OLTC, Cooling fins, Fans, Pipe lines etc.) in 110 KV Power Transformers
a) Applying grease for contacts and cleaning insulators in 230 KV, 110 KV AB switches
b) Applying grease for contacts and cleaning insulators in 33 KV,11 KV AB switches
a) Cleaning of Insulators and housing in 230 KV/110 KV P.T/C.T/LAS
b) Cleaning of Insulators and housing in 33KV/11 KV P.T/C.T/LAS
Replacement of Silica Gel in 230/110KV Auto Transformers and Power Transformers & drying out (9 x 12)
Periodical checking of tightness in Bolts and Nuts of 110 KV Bus clamps
Periodical checking of tightness in Bolts and Nuts of 230 KV Bus clamps
a) Single Kundha/Zebra taking measurement cutting and allied all works
a) Replacement of Support Insulators for 230 KV
b) Replacement of Support Insulators for 110 KV
a) Releasing and Refixing of Fixed contacts for 33/11 KV
b) Releasing and Refixing of jumpers FOR 333/11 KV
c) Releasing and refixing of Moving contacts for 33/11 KV
Releasing and refixing of ceiling fans/exhaust fans
Cleaning the Earth Pits & checking tightness of bolts and Nuts
Station Transformer cleaning of station Tr. Yard and Earth pits and outer surface and checking up tightness of connection (2 x 12)
Overhauling of Spring charing motor, MOM motor, Compressor motor in 400 KV, 230 KV, 110 KV, 33 KV , 11 KV Breaker, Releasing and refixing etc
a) Releasing and refixing after rectification - Tube light fitting
b) Releasing and refixing after rectification - SV lamp,
a) Releasing and refixing of Tube ight fitting in the premises of control room office room after rectification
b) Rectification of wiring defects in yard light/street lights
Labour charges for Transport of SF6 Gas cylinder from store to yard and back upto 60kg (3 x 12)
Cleaning of Air compressor (4 x 12)
Draining of Compressor Oil cleaning of container, Drying and Refilling with new compressor oil (4 x 12)
Renewal of Rubber washers in the non-return valve
Cleaning of dust in the Battery contacts and plates using wooden stick, topping up distilled water, checking and tightening of connections and applying vaseline etc. (4X12) Weekly Maintenance
Cleaning of diesel generator set and outer surface of panel Board, cheking of oil, and diesel level and filling the same if necessary (4 x 12)
Replacement of defective capacitor bank cells & dismandling the defective one and providing connections
GST AMOUNT AS APPLICABLE FOR THE ABOVE
PERUMAL.S.K
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .