Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.1 LAccepted-AOC NO 6 A ANNASANDRAPALYA NEAR BIG MASJID BUILDING HAL VIMANAPURA POST BANGALORE 560017 | BENGALURU URBAN | KARNATAKA | 560017 | L1 | Accepted-AOC L1 bidder | |
| 2 | L2₹14.0 L+₹2.8 L (25.0%)Rejected-Finance | L2 | Rejected-Finance Not L1 | |
| 3 | L3₹14.6 L+₹3.4 L (30.1%)Rejected-Finance | L3 | Rejected-Finance Not L1 |
Tender Value
Refer Docs
EMD Value
₹26,000
Closing Date
16 Oct 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GARRISON ENGINEER CENTRAL BANGALORE
MILITARY ENGINEER SERVICES GARRISON ENGINEER CENTRAL AGRAM POST BANGALORE 560007
MISC BR REPAIR WORKS TO EM INSTALLATION UNDER AGE BR II OF GE CENTRAL BANGALORE
2020_MES_378903_1
8963
Open Tender
Civil Works
Item Rate
180 days
BANGALORE
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
Yes
GARRISON ENGINEER CENTRAL BANGALORE
₹26,000
Yes
3 Dec 2020
18 Sept 2020
19 Oct 2020
18 Sept 2020
16 Oct 2020
2 Oct 2020
18 Sept 2020 - 1 Oct 2020
60 days
Amount
Taking down cement plaster on brick or stone walls etc including racking out joints, hacking for key, scrubbing down with water removing the rubbish out side MD land complete all as specified and directed
Dismantling of asbestos cement (corrugated or semicorrugated) sheeting, any thickness, in roof covering including ridges complete as directed. (measured flat overall)
Dismantling of wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
Dismantling of chain link fencing, any mesh, any size and type, fixed with steel or wood fillets complete all as specified and diected.
Demolition of stone slabs of any description and thickness in floors/ walls laid, bedded and pointed in any mortar etc complete including removing the same and debrises outside MD land all as directed.
Demolition of plain cement concrete (unreinforced) in ground floors and pavings not exceeding 15 cm thickness. (below or above ground level) removing the rubbish out side MD land complete all as specified and directed.
Demolition of brick work or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars etc removing the rubbish out side MD landcomplete all as specified and directed.
M & L for 75mm thick Plain cement concrete 1:4:8, type D-2 (using 40 mm graded stone aggregate) as in sub-base of floor, etc complete all as specified and directed.
M & L for 50 mm thick, plain cement concrete 1:2:4, type B-1 (using 20 mm graded stone aggregate) as in floors laid in panels, finishing the surfaces even & smooth without using extra cement complete all as specified and directed.
M&L for precast cement concrete block masonry type C1, 1:3:6 (20 mm graded granite stone aggregate) with solid blocks, exc 10 cm in width and setting in cement mortar 1:6 complete all as specified and directed.
M & L for precast machine pressed interlocking paver block any shaped and size conforming to IS- 15658-2006, 60mm thick, M-35 grade concrete with grey cement and no pigment, set and jointed in dry sand including providing 60mm thick dry sand filling below paver blocks complete all as directed
M & L for precast chequered cement concrete tiles of size 30cm x 30cm x 20mm to 25mm thick, as in floors etc, including 20 mm thick screed bed in cement mortar 1:4 and set & jointed in neat cement slurry and pointed in grey cement and pigments to match with the shade of tiles complete all as specified and directed.
M & L for Mild steel framed work such as grills, gratings, gates etc., with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bar, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar work conforming to Fe-410-0 Gde E-250 complete all as specified and directed.
S & F Rolled mild steel work as in trusses,purlins, posts etc using Joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc including cutting, welding complete. Steel section conforming to Fe-410-W (Gde-E-250) quality-B complete all as specified and directed.
S&F for pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick (Total coated thickness) of any colour, finished with resin coat on both surfaces @ 150 gm/sqm of coating (total both surfaces) having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with best quality self tapping screws as specified
S & F Pre-Painted galvalume aluminium zinc coating GI based Plain steel sheet 0.50mm thick (Total coated thickness) of any colour, finished with resin coat on both surfaces @ 150 gm/sqm of coating (total both surfaces) having tensile strength of 550 Mpa as in ridges/valley gutter, fixed with self tapping screws complete all as specified and directed. (Colour of ridge shall be same colour as that of sheet used for roof)
M&L 6mm thick asbestos cement corrugated or semi corrugated sheets in roof fixed with L type J type cranked hook bolts
S & F asbestos cement two piece serated ridge for corrugated sheets fixed with 'L' or 'J' type or cranked nut & bolts as in repairs complete all as specified.
Supply and Fixing chain link fencing of 4mm dia galvanised iron wire, mesh size 50X50mm, including provision of binding wire complete all as specified and directed. Note :- Weight of chain link shall be determined through BOO.
S & F in repair Galvanised 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured) complete all as specified and as directed.
S & F Mild steel works as in fencing posts and struts including necessary cutting tops tp shape as directed, drilling holes, bolting, notching for wire etc complete and other similar items of work conforming to Fe-290, Gde E-165 complete all as specified and as directed.
M & L for rendering 10 mm thick in cement mortar 1:6 on other than fair faces of brick masonry or concrete surfaces and finishing the surfaces even and smooth without using extra cement complete all as specified and directed.
M & L for rendering 15 mm thick in two layer (10mm + 5mm thick) on fair faces of brick work or concrete surfaces in cement mortar 1:4, mixed with water proofing compound at top 5mm thick layer by weight of cement as per manufacturer's instructions and finished the surface even and smooth without using extra cement complete all as specified and directed. (Note : WPC shall be measured and paid separately against respective item).
"Supply only" integral water proofing compound (ISI marked) complete all as specified and directed. (Make : Dr FIXIT/Fosroc/choksey)
M & L for rendering 5 mm thick in cement mortar 1:3 on concrete surfaces as in ceilings (sunshed, chajja, fins etc) and finishing surfaces even and smooth without using extra cement complete all as specified and directed.
M & L for Preparation of newly plastered surfaces of walls and applying two coats of cement base paint over a coat of alkali resistant priming paint complete all as specified and directed.
M & L for preparation of new plastered surfaces of walls and applying three coats of white wash complete all as specified and directed.
M & L for preparation of new plastered surfaces of ceiling and applying three coats of white wash complete all as specified and directed.
M & L for preparing old plastered surfaces of walls by complete removal of existing treatment and applying two coats of distemper-oil-emulsion over a coat of primer over 1 to 2 mm thick wall care putty complete all as specified and directed.
M & L for preparing old plastered surfaces of walls, etc and applying one coat of cement base paint complete all as specified and directed.
M & L for preparing old plastered surfaces of ceilings, etc and applying one white wash complete all as specified and directed.
M & L for Preparation of new steel surfaces of any description, over 10 cm in width or girth, not otherwise described and applying two coats of aluminium paint over a coat of red oxide, zinc chrome primer complete all as specified and directed.
M & L for Preparation of new steel surfaces of any description, over 10 cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide, zinc chrome primer complete all as specified and directed.
M & L for Preparation of old previously treated wood and wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
M & L for Preparation of old painted steel surfaces of any description, not otherwise described, over 10 cm width or girth and applying one coat of Synthetic enamel paint complete all as specified and directed.
M & L for cleaning concrete surfaces thoroughly with wire brush and removing of all loose particles and plaster shall be prepared with polymer modified mortar after applying a bond coat of Dr. Fixit pidicrete URP with cement @ 1:1 ratio, dust and sharp prostrations to get a sound surface before applying the water proof coating complete all vissble cracks shall be cut open in a V or U shaped groove to receive the polymer modified mortar. All the prepared surface shall be wetted before the application of polymer modified mortar. If cracks width is less than 10mm, Dr. Fixit crack X past/powder/URP shall be used and if the cracks width is more than 10mm, PU sealent shall be used and covered with fibre mesh complete. Providing and applying Dr. Fixit pidifine 2K an acrylic polymer modofied liquid applied contineous water proof coating in two coats to form a seamless membrane on top of the concrete surfaces. Pidilite 2K is CFTRI approved food grade materials which forms 1 mm thick membrane with 50% alongation after application. The product is designed to bridge a crack of 1 mm width. All application to be done as per manufacturer's specification ang instruction complete all as directed.
Supply and fix steel rolling shutters, gear operated type (Mechanical type) with bevel gear box and crank handle, with ball bearing, made out of 1.00 mm thick laths section, including 1mm thich mild steel hood/top cover, anchoring rod, hasp and staple finished with one shop coat of primer, erected in position as directed
Supply and fixing mild steel safety lever locks with 4 levers for rolling shutters complete all as directed.
M & L for Cutting out cracks to V-section in existing roofs or terracing, cleaning out and filling solidly with a hot mixture of bitumen and clean dry sand 1:1 (by weight).
M & L Water proofing treatment on RCC roof etc. comprising with the following operation and as specified herein below and as directed:- (a) Taking down existing old tarfelt, bituminous compound including cleaning & removing debris to a distance exc 100m & n.exc.250m. (b) 10 mm thick plastering in cement mortar 1:3 mixed with water proofing compound as per manufaturer's instruction, finished even & smooth. (WPC shall be measured and paid separately under respective item). (c) Preparing & cleaning of fully dried cement plastered surface (d) Applying one coat of cold bituminous primer to the plastered surface @ 0.25 liters per sqm conforming to IS-3384 . (e) A layer of APP based polymeric membrane membrane 3mm thick (minimum) weighing 3.5 kg per sqm reinforced with polyster non woven fabric (weighing not less than 160 gms/sqm )shall be applied over bituminous primer as specified above. Application of polymeric membrane shall be by torch application. The over lap shall be minimum 100 mm on transverse direction and 75 mm in longitudinal direction. (f) One coat of aluminium paint over the APP based membrane @ 0.11 Kg/Sqm
M & L for 75 mm thick, plain cement concrete 1:3:6, type C-2 (using 40mm graded stone aggregate) as in plinth protection laid in proper slope/gradient etc, finishing cement concrete surface even and smooth without using extra cement including making joints with bitumastic filing in proportion of bitumen and sand 1:2 complete all as specified and directed.
SHANTA DURGA TRADERS
Srisrinivasaenterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .