| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹49.2 LAccepted-AOC | L1 | Accepted-AOC Being L1 bidder | |
| 2 | L2₹51.6 L+₹1.3 L (2.66%)Rejected-Finance | L2 | Rejected-Finance Other than L1 Bidder |
| Sl No | Description | Qty | Unit | M/S MOHD KARIM L1 | M/S HONY CAPT RIGZIN SAMPHEL L2 |
|---|---|---|---|---|---|
| 1.00 | S&F 0.63mm thick Galvanised, corrugated mild steel sheeting with two corrugations side lap, fixed with coach screws and washers, in roofs, walls etc. with grade of zinc coating 275 fixed with L-type or J-type or cranked hook bolts in lieu of screws complete all as specified and directed by the Engineer–in–Charge. | 60 | Sqm | 820 ₹49,200 Lowest | 890 ₹53,400 |
| 2.00 | S&F 0.63mm thick Plain, galvanised, mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275 complete all as specified and directed by the Engineer–in–Charge. | 10 | Sqm | 800 ₹8,000 Lowest | 810 ₹8,100 |
| 3.00 | Precast cement concrete block masonry with solid blocks , type C1 1:3:6 (using 20 mm graded aggregate) .exc 20 cm in width and set in cement mortar 1:6 complete all as specified. | 8 | Cum | 9,000 ₹72,000 Lowest | 9,100 ₹72,800 |
| 4.00 | M&L, Rendering 15mm thick on fair faces of brick work finished even and fair in CM 1:4, complete all as specifeid and directed by engr-in-charge. | 30 | Sqm | 320 ₹9,600 Lowest | 324 ₹9,720 |
| 5.00 | M&L for Hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15cm thick, watered and rammed to a true surface with broken stone or Boulder all as specified and directed. | 6 | Cum | 690 ₹4,140 Lowest | 700 ₹4,200 |
| 6.00 | Framed work as in door or gates of angle or other section with gusset plates, rails, braces etc complete drilled for fixing of steel sheeting or other covering. Door to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings and hanging incl fastening and fixing complete all as specified and directed. | 350 | Kg | 130 ₹45,500 Lowest | 132 ₹46,200 |
| 7.00 | M&L for PCC 1:2:4 type B2 using 40mm graded in foundations, filling and mass concrete complete all as specified and directed by the Engineer–in–Charge. | 4 | Cum | 9,000 ₹36,000 Lowest | 9,100 ₹36,400 |
| 8.00 | M&L for PCC 1:2:4 type B1 (20mm graded agg) 100mm thick in foundations, filling and mass concrete complete all as specified and directed by the Engineer–in–Charge. | 37.62 | Sqm | 600 ₹22,572 Lowest | 610 ₹22,948.2 |
| 9.00 | Forming contraction (Dummy) joints 65mm deepx10mm wide, filled with sealing compound complete all as specified and directed by the Engineer–in–Charge. | 4 | 10RM | 900 ₹3,600 Lowest | 999 ₹3,996 |
| 10.00 | Forming 12mm thick expansion joints filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing com pound, Grade 'A' complete all as specified and directed by the Engineer–in–Charge. | 4 | 10 Sqm | 650 ₹2,600 Lowest | 676 ₹2,704 |
Tender Value
₹49.3 L
EMD Value
₹98,700
Closing Date
13 Sept 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE 873 EWS
Garrison Engineer 873 Engineer Works Section PIN 913 873 C/O 56 APO
PROVN OF GARBAGE DISPOSAL CHUTE WITH INCINERATOR AND WASTE COMPOSTER AT 30 (I) R AND O FLT AND SPL REPAIR (E/M) TO TXN NETWORK AT OLD BDE CAMP UNDER GE 873 EWS. (2nd Call)
2025_MES_724491_2
GE/873/EWS-64/2025-26
Open Tender
Civil Works
Item Rate
270 days
GE 873 EWS
Please refer NIT and Tender Documents
8 documents required · 8 mandatory
₹500
GE 873 EWS
₹98,700
Yes
15 Oct 2025
30 Aug 2025
15 Sept 2025
30 Aug 2025
13 Sept 2025
6 Sept 2025
Amount
S&F 0.63mm thick Galvanised, corrugated mild steel sheeting with two corrugations side lap, fixed with coach screws and washers, in roofs, walls etc. with grade of zinc coating 275 fixed with L-type or J-type or cranked hook bolts in lieu of screws complete all as specified and directed by the Engineer–in–Charge.
S&F 0.63mm thick Plain, galvanised, mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275 complete all as specified and directed by the Engineer–in–Charge.
Precast cement concrete block masonry with solid blocks , type C1 1:3:6 (using 20 mm graded aggregate) .exc 20 cm in width and set in cement mortar 1:6 complete all as specified.
M&L, Rendering 15mm thick on fair faces of brick work finished even and fair in CM 1:4, complete all as specifeid and directed by engr-in-charge.
M&L for Hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15cm thick, watered and rammed to a true surface with broken stone or Boulder all as specified and directed.
Framed work as in door or gates of angle or other section with gusset plates, rails, braces etc complete drilled for fixing of steel sheeting or other covering. Door to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings and hanging incl fastening and fixing complete all as specified and directed.
M&L for PCC 1:2:4 type B2 using 40mm graded in foundations, filling and mass concrete complete all as specified and directed by the Engineer–in–Charge.
M&L for PCC 1:2:4 type B1 (20mm graded agg) 100mm thick in foundations, filling and mass concrete complete all as specified and directed by the Engineer–in–Charge.
Forming contraction (Dummy) joints 65mm deepx10mm wide, filled with sealing compound complete all as specified and directed by the Engineer–in–Charge.
Forming 12mm thick expansion joints filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing com pound, Grade 'A' complete all as specified and directed by the Engineer–in–Charge.
S & F puff water tank 500 litres capacity, insulated cylindrical vertical type double layer duly filled with glass wool with closed top hoisted and to resist in temprature -30 degree to +35 degree celcius fixed in position with all fittings over PCC platform complete all as specified and directed.
Excavating in post holes (or similar holes) in soft/loose soil each not exceeding 0.5 Cum, getting out and removing excavated soil to a distance not exceeding 50m and making good surface complete all as specified and as directed by the Engineer-in-Charge.
Surface dressing n exc 15 cm deep in hard dense soil and getting out complete all as specified and directed by the Engineer–in–Charge.
S&F steel work as in roof trusses size 65x65x6 mm (framed) trussed, purlings, crane gantries, rails and fasternings and heavy bracket framing (Beam, Tee, angle channel or flat sections) including distance pieces, cleats etc( Fe-410-W (Gde E-250) Quality-A.
S&F rolled Mild steel plates plain square cot or notched (ordinary and counter sunk) forming holes, without any attachment.(Fe-410-W(Gde E-250) Quality-A) all as per specifed.
M&L for plate girder or single stanchions, built up of one beam or channel section with flange plates, caps, bases, splices, angle brackets, cleats and other connections etc (Fe-410-w (Gde E-250) Quality complete all as specified and directedby engineer-in-charge.
S&F 25 mm 3-layer PP-R Polypropylene random copolymer) concealed pipes SDR 7.4 (PN16)UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded poly-propyl-ene random fittings fixed complete to walls, ceilings or in floors etc.
S&F 40mm outer dia 3-layer PP-R poly-propylene random copolymer concealed pipes SDR 7.4 (PN-16) UV stavlized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete to walls, ceiling or floors etc. complete all as specified and directed.
Supply and fixing in replacement of PP-R Gate valve (brass insert) for 25 mm dia pipe as per requirement of the site all as specified and directed. Make: SFMC/Prince or equivalent.
Supply and fixing in replacement of PP-R Gate valve (brass insert) for 40 mm dia pipe as per requirement of the site all as specified and directed. Make: SFMC/Prince or equivalent
M&L for elestometric Nytral rubber isulation to PP-R pipes suitable for 25mm outer dia 22/19 thick with chicken wire mesh wire netting 25mm gauge, 20mm mesh with 0.01 mm aluminium foil including jointing and fixing material such as solvent adhesive SR-998 complete.
M&L for elestometric Nytral rubber isulation to PP-R pipes suitable for 40mm outer dia 22/19 thick with chicken wire mesh wire netting 40mm gauge, 35mm mesh with 0.01 mm aluminium foil including jointing and fixing material such as solvent adhesive SR-998 complete.
M&L for preparation of new untreated steel surfaces of any description, not otherwise described over 10cm width or girth and painting with two coats of synthetic enamel paint over a coat of red oxide complete all as specified and directed by Engr-in-charge.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in hard/dence soil complete all as specified.
Excavating in trenches, exc 1.5 m wide and n exc 3.00 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 3.00 m in depth and getting out in hard/dence soil complete all as specified.
M&L Returing, filling in incl spreading, levelling watering and well remming in layers n.exc 25cm width, Complete all as specified and directed.
M&L for Removing excavated materialn. exc 50m and depositing where directed at a level n exc. 1.5m above the starting point.
Unwashed Sand cushioning to under ground cable provided with a layer of 8 cm deep before laying and 15 cm covering above the top edge of cable after laying complete all as specified. Note : maesurement shall be done after puning down of sand.
M&L unreinforcedprecast factory made concreate cable cover class LV type-I with flat size 250X150x40mm complete all as specified and directed.
Material and Labour for PCC (1:3:6) type C-2 using 40 mm graded aggregate as in foundaton of pole/stay complete all as specified and directed by the Engineer–in–Charge.
M&L for Cement concrete Type D-2, 1:4:8 mix using 40mm graded stone aggregae as in foundation fillings, mass concrete complete all as specified and directed.
M & L for 150 mm thick PCC 1:4:8 type D-2(40 mm graded stone agg) as in foundation fillings, mass concrete complete all as specified and directed.
M&L for rolling and consoli dating formation surfaces in cutting exc 5 to n exc 8 ton for rolling include for watering as necessary and consolidation to the required lever, gradient or camber, keeping roller wheels wet, if required filling in hollows and depressions complete all as specified and directed.
Supply, laying, fixing, passing through pipe or laid in trenches and testing underground XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross section area 25 sqmm 4 core complete all as specified and directed by Engineer-in-charge.
Supply, laying,fixing, passing through pipe or laid in trenches and testing underground XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross section area 3.5 core 35 sqmm all as specified and directed by Engineer-in-charge.
Taking out un-serviceable/faulty cable/service connection cable of any grade / type / class of any size for repair / replacement from pole / wall / cable duct under ground trench etc for re-use or removal from site of work all as specified and as directed by the Engineer-in-charge (Note- Excavation and earth work shall be measured and paid separately).
Supply, laying and cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm 2 core complete all as specified and directed Make : Polycab, Havells. NOTE: The cable must be FRLS.
Supply, laying and cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 4 core complete all as specified and directedMake : Polycab, Havells. NOTE: The cable must be FRLS.
6.Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sq mm 3.5 core complete all as specified and directed Make : Polycab, Havells. NOTE: The cable must be FRLS.
7.Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 70 sq mm 3.5 core complete all as specified and directedMake : Polycab, Havells NOTE: The cable must be FRLS. .
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 sq mm 3.5 core complete all as specified and directedMake : Polycab, Havells. NOTE: The cable must be FRLS.
Supply, installation, testing and commissioning LT panel, factory made dust and vermin proof outdoor type made out of 3.15 mm thick CRCA sheet including seperate compartment for each MCCB & for cable and busbar, cable alley for incoming and outgoing cables, mounted on frame of MS angle iron 40mmx40mmx5 mm with front and back openable door with lock & Key, lifting hooks on top of the canopy, gasket protection to each compartment, including necessary grouting and double coat powder coated of grey colour painting complete with following accessories.The degree of protection and Aluminium bus bar chamber (4 nos of aluminum bus bar of size 40mmx10mm), 3 phase 415 volts 400 Amps all as required panel shall be IP-65 including foundation all as specified and directed.
Supply, installation, testing and commissioning LT panel, factory made dust and vermin proof outdoor type made out of 3.15 mm thick CRCA sheet including seperate compartment for each MCCB & for cable and busbar, cable alley for incoming and outgoing cables, mounted on frame of MS angle iron 40mmx40mmx5 mm with front and back openable door with lock & Key, lifting hooks on top of the canopy, gasket protection to each compartment, including necessary grouting and double coat powder coated of grey colour painting complete with following accessories.The degree of protection and Aluminium bus bar chamber (4 nos of aluminum bus bar of size 40mmx10mm), 3 phase 415 volts 400 Amps all as required panel shall be IP-65 including foundation all as specified and directed.
Supply and install, testing and commissioning of Bus bar chamber of size 60 cm x 60cm x 40 cm outdoor type suitable for LT 415 volts 3 phase 4 wire system factory made cubical complete materialised dust and vermin proof (protection class IP 54), made out of 3.15mm thick MS sheet (CRCA) including factory made hinged type door both side openable with locking arrangement duly painted with two coats of synthetic enamel paint with powder coated finish over a coat of zinc chrome primer, the panel should be mounted on 30mmx30mmx5mm angle iron on all four legs and base of the feeder pillar. PCC work shall be deemed to be included in the quoted rates. 150mm x150 mmx300 mm on each legs of angle iron, complete all as specified and directed by Engineer-In-Charge. the panel board shall be comprising of the following accessories:_
Supply and erecting and fixing in proper position steel tubular swaged poles complete with cast iron base plate, final taper plug, bolts, nuts and screws as specified type 410 SP-31 (9.00metres long) all as specified and as directed. Note: (i) Excavation ,earth work and PCC shall be measured and paid separately. (ii) Painting will be measured and paid seperately under relevent item. Make : TATA, MS.
M & L for bracket made out of GI tubing 25mm/40mm dia,light grade 1.5 mtr long including fixing with MS clamps 2 Nos made out of 25 mm wide 3mm thick flat iron with M.S nuts bolts 75 mm long 12 mm dia 4 Nos with flat washer (3mm thick) 2 No for each including painting with aluminium paint over one coat of red oxide to the M.S clamps & bracket etc complete.
Supply and fixing LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete making all necessary connection with suitable capacity of 3 core circular cable complete all as specified and directed. Make: Havells/Crompton/Bajaj
Supply & fix PVC sintex Junction box of size 280 X 170 X 130 mm Cat No GS-JB-2817 Hinged (L) wiith 2 way connector mounted on epoxy insulators for looping of cable for 1Phase and 1neutral fixed on pole with the help of MS nuts bolts and MS clamps-2 Nos of size 40 mm X 4 mm thick with one No MCB SP 6 Amp capacity mounted on din rail inside box. work also includes making suitable hole in pole to take out connections to fitting if required at site and provisioning of 1.0 sqmm 3.0 core flexible PVC insulated copper cable from junction box to conector of street light.
Supply, laying,fixing, passing through pipe or laid in trenches and testing PVC heavy duty electric cable with aluminium conductor 1100 volts grade cross section area 3 core 1.5 sqmm all as specified and directed.(Make -Havells NOTE: The cable must be FRLS.
M & L for GI tubing 40 mm dia,Medium grade 1.5 mtr long including fixing complete all as specified and directed.
S&F pin type, pocelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 150mm height, 150mm dia for 1100 volts grade.
M&L for aluminium conductor steel reinforced (ACSR) on pole stringing properly on insulators and binding with aluminium binding wire, jumper set complete for any size (Ferret, Wessal, Squirel) of conductor complete all as specified and as direcetd by the Engineer-in-Charge.(NOTE:- Measurement and payment shall be made by measuring horizontal distance between centre of two adjustant poles and adding 3% extra for sag, joints and jumpers etc).
Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique & necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 Mpa working pressure.
Supply, fabricating , fixing structural mild steel channel angle iron, flat iron and brackets etc for fabrications of cross arms, bracings, supports, D-clamps, stiffeners, eye hooks, bolts, pole clamps and back plates including nuts, bolts and washers, welding banding cold , or hot drilling holes for insulators bolts in any shape or size as indicated or directed and inclusive of one red oxide primer coat ,one under coat and one finishing coat of aluminium paint complete.(Insulators to be measured and paid for separately)
Supply and fix galvanised stay strand wire 7/4mm suitable for staying of poles etc
M&L for Earthing complete with galvanized steel earth plate electrode 600x600x6mm thick burried directly in ground ( earth plate not less than 2.25 mtr deep below normal ground level) with top edge of earth plate not less than 1.5 mtr below the normal ground level connected to galvanized strip of size 32 x 6 mm thick by means of nuts bolts and washers of galvanized iron or steel all as shown in electrc plate No. 3 of SSR Part-I connected to OH conductor on pole/Panel/main switch board etc all as specified or indicated and testing on completion including provison galvanized strip protected by 40mm bore, light grade pipe and watering pipe shall be 20mm bore medium grade GI pipe including excavation & earth work, PCC pit with RCC cover, charcoal, salt, funnel, GI strip and protection pipe upto 7.5 mtr complete all as specified and directed by Engineer-in-charge.
Supply and fix galvanized iron strip 32x6mm fixed with saddles & fixing screws, PVC dash fastners, insulators fixed from test point to earth on walls or burried in ground/drawn into hume pipe. Note: Excavation & earth work shall be measured and paid for separately under relevant item of schedule.
Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique & necessary machine including GI pipe 40mm medium grade.
M & L Point wiring using approved colour coding as per IS for modular switch and socket in concealed conduit with 1.5 Sq mm FRLS multi stranded copper conductor single core PVC insulated and unsheathed 1100 V grade drawn through conduit and including rigid 20 MM In stove enamelled Steel conduit and conduit accessories ISI marked with valid CML No (IS-9537-1983 for conduit and IS:3419:1976 for conduit accessories) medium grade including fixing/grouting with mild steel / pressed steel sunken boxes (with earth dolly) of not than 2.0 mm thickness covered with suitable modular cover plate including running up of 1.5 Sq mm multistranded copper conductor PVC insulated cable as earth continuity conductor along with wiring and connecting to the common earth dolly for fixing the switches/ sockets/ regulators etc all as specified and directed at site for the followings. NOTE: 1. Modular Cover Plate is inclusive of the rated quoted by the contractor 2. Swittches and sockets shall be measured and paid separately.
(a) One light/fan/bell point controlled by one, one way SP switch
(d) One 3/5 pin 5/6 Amps switch socket outlet point controlled by one switch on the independant board.
All as per item No. 1 but point wiring using 2.5 Sqmm single core multistranded copper conductor PVC insulated unsheathed FRLS 1100 Volts grade including running of 2.5 Sq mm multi stranded copper conductor PVC insulated cable as earth continuity conductor for 3/5 Pin 15/16 Amps switch socket combination point on independent board.
S & F Modular switch 1 way 5/6 Amps, 1 Module ISI marked with valid CML No complete all as specified and directed.
S & F Modular switch 1 way 15/16 Amps, 1 Module ISI marked with valid CML No complete all as specified and directed.
S &F modular socket multipurpose 2/3 Pin, 6 amps, 2 Module ISI marked with valid CML No complete all as specified and directed.
S &F modular socket multipurpose 2/3 Pin, 16 amps, 2 Module ISI marked with valid CML No complete all as specified and directed.
S & F ceiling rose three brass terminal, ISI marked PVC/Polycarbonate surface, isolated body complete all as specified and directed.
S & F wall mounted compact one piece, FLAMEPROOF well glass fitting 200W GLS/125W HPMV/160W MLL/70 W Metal Halide Indirect only fitting 1x200w comprises of extruded channel in thermally conductive material, high translucent serrated milky white diffuser, input operating voltage range 120-270V, CCT-6500K, view angle 120(Min),operating temprature -10 to 50 degree centigrade, PF more than 0.90, luminous flux efficacy equal/ greater than 100 lumens per watt, CRI equal/ greater than 75, complete and connecting to the point wiring with necessary flexible copper conductor of multistrand two core 1.0 sqmm of suitable length from fitting to the ceiling rose.Make: WG/A/1231
S&F MCB Distribution board,concealed fluch to wall for mounting MCCBs and MCBs, factory made,double door type with hinged door with locking arrangement, IP43 protection,Mechanical impact strength IK 08, fabricated out of CRCA sheet not less than 1.20 mm thick fitted with DIN channel,isolated neutral bar, 200 amps rated bus bar, DBs shall be semi glossy finished with epoxy polester based powder paint process to ensure smooth finish and protection against corrosion atmosphere complete all as specified and directed for following sizes. make: Legrand/L&T/Havells/Indo asian.
(b) TPN DB 4 way, 240V
S&F MCBs rated short-circuit breaking capacity, Icn 10kA, C curve, ISI/CE marked as per IS/IEC 60898 of the following type and rating all as specified and directed.
(a) MCB DP 40A
(b) MCB TPN 63A
M & L Submain wiring with 4 runs of single core 10 sqmm PVC insulated unsheated multistranded FRLS 1100 volts grade with copper conductor drawn through 40 mm GI conduit and conduit accessories of light grade including one run of single core 10 sqmm PVC insulated unsheated multistranded 1100 volts grade with copper conductor cable as earth continuty conductor along with the wiring and connected from DB to DB/main board complete all as specified and as directed. Note:1. Five runs of 10 sqmm wire shall be measured as one unit length. 2. GI pipe will be paid and measured seperately
M&L for earthing complete with galvanised steel earth plate electrode 60cm X 60cm X 6mm thick, burried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr below normal ground level connected to galvanized earth lead wire 4.00 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or stee all as shown in electrcal plate No 3 of SSR Part-I connected to continious earth wire or main switch board/ panel etc all as specified or indicated and testing on completion including provision of earth wire protection by 15 mm dia,light grade GI pipe and watering pipe shall be 20 mm bore medium grade GI pipe including excavation & earth work, PCC pit with RCC cover, charcoal, salt, funnel, GI wire and protection pipe upto 7.5 mtr complete all as specified and directed.
S&F Fire Extinguisher water, CO2 9 ltr (IS-940/6234)
S & F Fire extinguisher mechanical form CO2 9 ltr
S&F Bucket sand/Water (IS-2546)
S&F Firemen Axe (IS-926)
S&F Fire hook (IS-927)
S&F Fire beater
S& F Fire spade
S&F dry powder type (ABC) fire extinguisher of cap 9 Kg as per IS specification
M&L for erection of fire point with PCC steps for keeping above items, provision of hooks, fire beater, spade, Axe for keeping them inside fire point shelter. The shelter should be neatly painted red and font Aag both in Hindi and fire painted in white colour on the fire point, complete all as specified and directed.
Supply, install, testing and commissioning of oil fired incinertor having 25Kg/Hr burning capacity horizontal/vertical type comprising of primary chamber, secondary chamber, designed on "controlled air" incineration principle and provided with minimum of 115 mm thick refractory and insulation bricks conforming to IS-8-1994 and IS-2042-2006 to sustain minimum temperature of 1000 Degree centrigrade in the primary chamber and 1200 Degree centrigrade in secondary chamber, one fully automatic presssure jtet type burner for each chamber, chamber made of mild steel plate of adequate thickness (minimum 5mm thick), 4.5 to 5 Mtr chimney exhaust system, high pressure ventury scrubber, droplet separator etc. Note :- (a) Fuel tank suitable fabricated out of mild steel, provided with connection for supply, return, drain & vis checking of quantity of fuel in the tank. (b) An emergency stack to vent out the gases in case of power failure. (c) Circulation pump, recirculation tank, inter connection piping, ID fan, FD fan, instruments, valves, dampers & fittings etc.
Supply, install, testing and commissioning of compost machine having 50 Kg/ day capacity of converting organic waste into compost. The machine should handle organic waste, including food scraps, yard waste and paper. should minimise or eliminate unpleasant odors associated with composting . Composting type -Microorganism based 24 Hrs composting. Operation - fully automatic within 24 Hrs, Input - segregated organic waste, Out put- dry organic compost, Power supply -415 Volts, frequency -50 Hz, three phase electric supply, power rating 4 -5 HP, composting tank shall be made of stainless steel body or MS body with powder coated, Control panel system - Integrated or extruded panel system. Type of composting - Microorganism based natureal composting in high temperature, Volumen reduction 85-90 %, compost generated per day 10-15% of waste input.
Supply and fix double wall corrugated (DWC) outer pipe 63 mm and inner dia 50 mm fix complete to wall, poles etc with suitable clamp for protection of cable complete all as specified and directed by Engineer-in-charge.
Deduct Schedule of Credit of Rs (-) 83,145- (Minus) as listed in Schedule 'A' Part-II. Contract Sum shall be arrived after deducting the credit amount. Note :- Tenderers will not quote against this item being a firm amount.
M/S HONY CAPT RIGZIN SAMPHEL (BID ID -3424822)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .