Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.0 CrAdmitted-Finance | ₹1.0 Cr | L1 | Admitted-Finance |
| 2 | L2₹1.1 Cr+₹4.3 L (4.13%)Admitted-Finance | ₹1.1 Cr+₹4.3 L (4.13%) | L2 | Admitted-Finance |
| 3 | L3₹1.1 Cr+₹7.7 L (7.39%)Admitted-Finance B 3 88 PASHCHIM VIHAR NEW DELHI 110063 | WEST | DELHI | 110063 | ₹1.1 Cr+₹7.7 L (7.39%) | L3 | Admitted-Finance |
| 4 | L4₹1.2 Cr+₹13.6 L (13.1%)Admitted-Finance X 125 NEW ROSHANPURA SHAHEED RAJESH GILL MARG NAJAFGARH SOUTH WEST DELHI DELHI 110043 UDYAM DL 10 0019190 06AADCJ2143B1Z8 B 07AADCJ2143B1Z6 R MSME STATUS AS VERIFIED | WEST DELHI | DELHI | 110043 | ₹1.2 Cr+₹13.6 L (13.1%) | L4 | Admitted-Finance |
| 5 | L5₹1.2 Cr+₹15.2 L (14.6%)Admitted-Finance 8 99 GROUND FLOOR GEETA COLONY NEW DELHI DELHI 110031 | SHAHDARA | DELHI | 110031 | ₹1.2 Cr+₹15.2 L (14.6%) | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | TRANSCEND CONTRACTS PVT. LTD. L5 | SMD Solutions L2 | HONEY COLLECTION L3 | Utility Services L6 | JUHI AND JAI CONTRACTORS PVT LTD L4 | Spectrum A2Z Solutions L1 | Mvac Engineers L7 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00Supply Installation, Testing & Commissioning of not less than following capacity air cooled Ductable AC unit suitable for cooling, having all twin rotary / Scroll Compressor(s), complete with ductable indoor and matching outdoor, with R-410 A or environment friendly Refrigerant, vibration isolators, with suitable foundation for outdoor and ceiling suspender for indoor etc. complete as required. The unit shall deliver the rated capacity at AHRI conditions and work even at 50 degree Centigrade ambient temperature without tripping. The unit shall be suitable to work on 400 V+/-10%, 3 Phase, 50Hz AC power supply. The Indoor unit shall be equipped with washable synthetic media pre-filter, fan section with low noise fan/ dynamically balanced blower, multispeed motor, coil section with DX copper coil, expansion valve, outer cabinet, corded or cordless remote control with batteries, drain pan, necessary accessories etc. suitable for operation on 230 V ± 10%, 50 Hz, single phase ac supply, complete as required. The cooling capacity of indoor unit will be at air inlet conditions of 27 degree C DB and 19 degree C WB temperature. The unit shall be filled with first charge of the refrigerant and ready for use as required (any additional refrigerant required due to long pipe lines shall be within the scope of contractor). Providing and making proper canvass connection alongwith matching with existing duct entry, collar formation etc. are within the scope of the work. The COP / EER shall not be less than 2.4. (Acceptable make: Daikin / LG / Blue Star / Toshiba / Carrier / O'General / Mitsubishi) | ||||||||||
| 1.01 | 11.0 TR (having minimum two compressors) | 11 | Each | 2,27,326 ₹25,00,586 Lowest | 2,55,000 ₹28,05,000 | 3,71,018 ₹40,81,198 | 2,54,290 ₹27,97,190 | 2,58,513.02 ₹28,43,643.22 | 2,45,000 ₹26,95,000 | 2,40,300 ₹26,43,300 |
| 1.02 | 8.5 TR | 4 | Each | 1,76,527 ₹7,06,108 | 2,15,000 ₹8,60,000 | 3,00,000 ₹12,00,000 | 1,75,230 ₹7,00,920 Lowest | 2,11,012.03 ₹8,44,048.12 | 2,05,000 ₹8,20,000 | 1,96,400 ₹7,85,600 |
| 2.00Supply Installation, Testing & Commissioning of not less than following capacity air cooled Ductable AC unit suitable for cooling, having all twin rotary / Scroll Compressor(s), complete with ductable indoor and matching outdoor, with R-410 A or environment friendly Refrigerant, vibration isolators, with suitable foundation for outdoor and ceiling suspender for indoor etc. complete as required. The unit shall deliver the rated capacity at AHRI conditions and work even at 50 degree Centigrade ambient temperature without tripping. The unit shall be suitable to work on 400 V+/-10%, 3 Phase, 50Hz AC power supply. The Indoor unit shall be equipped with washable synthetic media pre-filter, fan section with low noise fan/ dynamically balanced blower, multispeed motor, coil section with DX copper coil, expansion valve, outer cabinet, corded or cordless remote control with batteries, drain pan, necessary accessories etc. suitable for operation on 230 V ± 10%, 50 Hz, single phase ac supply, complete as required. Indoor Unit shall be fitted with eye ball type spot jet diffuser (4 nos. or 3 nos. as directed) made of Aluminum construction with fully reversible spout with 180 degree rotation. Jet nozzle section is mounted in aluminium / GI square plate covered by flanged border onto the unit delivery mouth with necessary ducting work or modifications. The cooling capacity of indoor unit will be at air inlet conditions of 27 degree C DB and 19 degree C WB temperature. The unit shall be filled with first charge of the refrigerant and ready for use as required (any additional refrigerant required due to long pipe lines shall be within the scope of contractor). Providing and making proper canvass connection alongwith matching with existing duct entry, collar formation etc. are within the scope of the work. The COP / EER Shall not be less than 2.4. (Acceptable make: Daikin / LG / Blue Star / Toshiba / Carrier / O'General / Mitsubishi) | ||||||||||
| 2.01 | 8.5 TR | 3 | Each | 2,00,656 ₹6,01,968 | 2,15,000 ₹6,45,000 | 3,25,000 ₹9,75,000 | 1,94,110 ₹5,82,330 Lowest | 2,34,762.53 ₹7,04,287.59 | 2,05,000 ₹6,15,000 | 2,05,300 ₹6,15,900 |
| 3.00Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft / hard drawn copper refrigerant piping for VRV / VRF / Split AC system, complete with fittings (including Y-joints), with suitable adjustable ring type hanger supports, jointing / brazing including accessories, cutting of glass window wherever required with proper finishing, insulated with XPLE Class-O tubular insulation / with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquidlines, all accessories as per specifications etc. packing of all leakage either on wall or window with silicon / insulation, as required : [Acceptable make of copper pipes : Uniflow / Manibhadra / Ganpati / Mexflow / Mandev / Indigo / Godrej / Visiaro) Acceptable make of tubular insulation: Visiaro / Marshland / Avi Global / Armaflex / Aajjo / Dynamic / Uttam] NOTE: (1) The copper piping and piping circuit should be with minimum number of joints, which shall be attained by: (a) Using one end expanded tubes (b) bending the tubes instead of using elbow joints wherever 90 degree bending is required (2) Piping should be routed at site in such a manner, that brazed joints in the refrigeration piping are kept to a minimum (3) The makes of tube fittings shall be same as that of tubes (4) The thickness of fittings used shall be same as that of the pipe | ||||||||||
| 3.01 | 9.5 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation | 200 | Metre | 532 ₹1,06,400 | 150 ₹30,000 Lowest | 350 ₹70,000 | 696 ₹1,39,200 | 680.09 ₹1,36,018 | 850 ₹1,70,000 | 420 ₹84,000 |
| 3.02 | 12.7 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation | 120 | Metre | 702 ₹84,240 | 950 ₹1,14,000 | 450 ₹54,000 Lowest | 863 ₹1,03,560 | 892.7 ₹1,07,124 | 1,000 ₹1,20,000 | 570 ₹68,400 |
| 3.03 | 22.2 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation | 200 | Metre | 1,149 ₹2,29,800 Lowest | 1,500 ₹3,00,000 | 1,400 ₹2,80,000 | 1,425 ₹2,85,000 | 1,563.25 ₹3,12,650 | 1,250 ₹2,50,000 | 1,270 ₹2,54,000 |
| 3.04 | 28.58 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation | 120 | Metre | 1,391 ₹1,66,920 Lowest | 1,850 ₹2,22,000 | 2,000 ₹2,40,000 | 1,808 ₹2,16,960 | 1,992.56 ₹2,39,107.2 | 1,400 ₹1,68,000 | 1,610 ₹1,93,200 |
Tender Value
₹1.4 Cr
EMD Value
₹2.8 L
Closing Date
4 Jun 2025, 3:00 pmClosed
Assistant Executive Engineer-in-charge, AC Divisio
Assistant Executive Engineer-in-charge, AC Division, Works Department, IIT Delhi, Hauz Khas, New Delhi-110016
SITC of Ductable AC Units in Different Places in IIT Delhi
2025_IIT_860280_1
IITD/WORKS (SP-4997)/2025
Open Tender
Miscellaneous Works
Works
120 days
Indian Institute of Delhi Hauz Khas
As per tender documents
11 documents required · 11 mandatory
₹0
₹2.8 L
4 Jul 2025
15 May 2025
5 Jun 2025
15 May 2025
4 Jun 2025
15 May 2025
Amount
Supply Installation, Testing & Commissioning of not less than following capacity air cooled Ductable AC unit suitable for cooling, having all twin rotary / Scroll Compressor(s), complete with ductable indoor and matching outdoor, with R-410 A or environment friendly Refrigerant, vibration isolators, with suitable foundation for outdoor and ceiling suspender for indoor etc. complete as required. The unit shall deliver the rated capacity at AHRI conditions and work even at 50 degree Centigrade ambient temperature without tripping. The unit shall be suitable to work on 400 V+/-10%, 3 Phase, 50Hz AC power supply. The Indoor unit shall be equipped with washable synthetic media pre-filter, fan section with low noise fan/ dynamically balanced blower, multispeed motor, coil section with DX copper coil, expansion valve, outer cabinet, corded or cordless remote control with batteries, drain pan, necessary accessories etc. suitable for operation on 230 V ± 10%, 50 Hz, single phase ac supply, complete as required. The cooling capacity of indoor unit will be at air inlet conditions of 27 degree C DB and 19 degree C WB temperature. The unit shall be filled with first charge of the refrigerant and ready for use as required (any additional refrigerant required due to long pipe lines shall be within the scope of contractor). Providing and making proper canvass connection alongwith matching with existing duct entry, collar formation etc. are within the scope of the work. The COP / EER shall not be less than 2.4. (Acceptable make: Daikin / LG / Blue Star / Toshiba / Carrier / O'General / Mitsubishi)
11.0 TR (having minimum two compressors)
Supply Installation, Testing & Commissioning of not less than following capacity air cooled Ductable AC unit suitable for cooling, having all twin rotary / Scroll Compressor(s), complete with ductable indoor and matching outdoor, with R-410 A or environment friendly Refrigerant, vibration isolators, with suitable foundation for outdoor and ceiling suspender for indoor etc. complete as required. The unit shall deliver the rated capacity at AHRI conditions and work even at 50 degree Centigrade ambient temperature without tripping. The unit shall be suitable to work on 400 V+/-10%, 3 Phase, 50Hz AC power supply. The Indoor unit shall be equipped with washable synthetic media pre-filter, fan section with low noise fan/ dynamically balanced blower, multispeed motor, coil section with DX copper coil, expansion valve, outer cabinet, corded or cordless remote control with batteries, drain pan, necessary accessories etc. suitable for operation on 230 V ± 10%, 50 Hz, single phase ac supply, complete as required. Indoor Unit shall be fitted with eye ball type spot jet diffuser (4 nos. or 3 nos. as directed) made of Aluminum construction with fully reversible spout with 180 degree rotation. Jet nozzle section is mounted in aluminium / GI square plate covered by flanged border onto the unit delivery mouth with necessary ducting work or modifications. The cooling capacity of indoor unit will be at air inlet conditions of 27 degree C DB and 19 degree C WB temperature. The unit shall be filled with first charge of the refrigerant and ready for use as required (any additional refrigerant required due to long pipe lines shall be within the scope of contractor). Providing and making proper canvass connection alongwith matching with existing duct entry, collar formation etc. are within the scope of the work. The COP / EER Shall not be less than 2.4. (Acceptable make: Daikin / LG / Blue Star / Toshiba / Carrier / O'General / Mitsubishi)
Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft / hard drawn copper refrigerant piping for VRV / VRF / Split AC system, complete with fittings (including Y-joints), with suitable adjustable ring type hanger supports, jointing / brazing including accessories, cutting of glass window wherever required with proper finishing, insulated with XPLE Class-O tubular insulation / with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquidlines, all accessories as per specifications etc. packing of all leakage either on wall or window with silicon / insulation, as required : [Acceptable make of copper pipes : Uniflow / Manibhadra / Ganpati / Mexflow / Mandev / Indigo / Godrej / Visiaro) Acceptable make of tubular insulation: Visiaro / Marshland / Avi Global / Armaflex / Aajjo / Dynamic / Uttam] NOTE: (1) The copper piping and piping circuit should be with minimum number of joints, which shall be attained by: (a) Using one end expanded tubes (b) bending the tubes instead of using elbow joints wherever 90 degree bending is required (2) Piping should be routed at site in such a manner, that brazed joints in the refrigeration piping are kept to a minimum (3) The makes of tube fittings shall be same as that of tubes (4) The thickness of fittings used shall be same as that of the pipe
9.5 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation
12.7 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation
22.2 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation
28.58 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation
GI TRAY SUPPORT: Supplying and installing following size of perforated Hot Dipped Galvanised Iron Cable tray (galvanisation thickness not less than 50 microns) with perforation not more than 17.5% in convenient sections, joined with connectors, suspended / supported from the ceiling / wall with GI suspenders including GI bolts and nuts, GI C-Channels, etc. including GI protective sheet covering outside the room as required. (Only for outdoor portion)
225 mm width x 50 mm depth x 1.6 mm thickness
DRAIN PIPE: Supplying and laying of ISI marked CPVC pipe of 32 mm dia for draining of sweated water / drawing communication cable from AC evaporator (indoor) unit including providing tee, joints, elbows, supports, etc. insulated with XLPE class - O tubular insulation / with Class-O closed cell elastomeric nitrile rubber tubular sleeves sections of 19 mm thick etc. complete as required. (Acceptable make: Astral / Geroge Fischer / Finolex / Prakash / Supreme / Prince)
Supplying and fixing of following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc as required. (but without MCB/RCCB/Isolator) (Acceptable make: Havells / Siemens / L&T / Legrand / ABB / Schneider / C&S / HPL / Hager)
12 Way, Double door
8 Way, Double door
Supplying and fixing of following ways surface/ recess mounting, 7 Segment vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 100 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's (but without MCB's and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) (Acceptable make: Havells / Siemens / L&T / Legrand / ABB / Schneider / C&S / HPL / Hager)
6 Way, Double door
4 Way, double door
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (Acceptable make: Havells / Standard / HPL/ Legrand / L&T / Polycab / C&S / ABB / Siemens / Schneider)
Single Pole
Double pole (as incomer to DB)
Triple pole and neutral
Supplying and fixing Cable End Box (loose wire box) suitable for following single pole and neutral sheet steel, MCB DB, 240 volts, on surface / recess complete with testing and commissioning etc. as required.
8 Way, Double door SPN MCBDB
12 Way, Double door SPN MCBDB
Supplying and fixing Cable End Box (loose wire box) suitable for following triple pole and neutral, sheet steel, MCB DB, 415 volts, on surface / recess complete with testing and commissioning etc. as required.
4 Way, Double door 7 segment TPN MCBDB
6 Way, Double door 7 segment TPN MCBDB
Providing and fixing 4 mm dia copper wire on surface or in recess for loop earthing along with existing surface / recessed conduit / submain wiring / power cable as required.
Supplying and laying of ISI marked PVC insulated FR multistranded following type copper cable of following size of 1.1 kv grade conforming to IS694:2010 as required. (for communication and power) (Acceptable make: KEI / Finolex / Polycab / Universal / Havells / Gloster / RR Kabel / Rallison) [NB: Single stranded cable not to be used]
2 core x 1.0 sqmm
3 core x 4.0 sqmm
5 core x 6.0 sqmm
5 core x 10.0 sqmm
4 core x 25 sqmm
4 core x 70 sqmm
Providing and fixing following rating and breaking capacity and pole MCCB Conforming to IS/IEC 60947-2 & IEC 60947-2 with thermomagnetic release and terminal spreaders in sheet steel enclosure including drilling holes, duly factory painted as required, making connections, providing spreader terminal, etc. as required. (Acceptable make: Siemens / L&T / GE Power / C&S / Crompton / Havells / Legrand) For main power connection.
200 A, 35 kA, FPMCCB
100 A, 25 kA, FPMCCB
Supplying and making end termination with brass compression gland and tinned copper lugs for following size of pvc insulated and pvc sheathed / XLPE copper conductor cable of 1.1 kV grade as required.
4 core x 25 sqmm
4 core x 70 sqmm
Fabricating, Providing and fixing M.S. iron frame fabricated with M.S. C-channel of size 50 mm x 50 mm x 6 mm (thick) for resting the condenser unit on the roof / floor of the building duly supported from the bottom as required including painting and grouting the framework with cement concrete etc. complete as required. (Acceptable make of angle: SAIL / Jindal / TATA / Prakash / Nezone)
Providing and laying in position cement concrete 1:3:6 (1 cement : 2 coarse sand : 6 graded stone aggregate 40 mm nominal size) in foundation of pump, DG set etc including form work etc as required.
Supply, installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular / round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vane hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. [For outdoor application] (Acceptable make of sheet: TATA / Jindal / SAIL / HSL / Nippon / National)
Thickness 0.63 mm sheet
Thickness 0.80 mm sheet
Duct Thermal Insulation: Supplying and fixing of following thickness duly laminated aluminium foil of mat finish closed cell nitrile rubber (Class "O") insulation on existing duct after applying suitable adhesive for nitrile rubber. The joints shall be sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required. (Acceptable make: Armaflex / Aerofoam / Aflex)
Supply, installation, testing and commissioning of GI volume control duct damper complete with neoprene rubber gasket, nuts, bolts, screws, linkages, flanges, etc. as per specifications. (Acceptable make: System Air / Advance Aircool / Caryaire)
Supply, installation, testing and commissioning of GI volume control duct damper complete with neoprene rubber gasket, nuts, bolts, screws, linkages, flanges, etc. as per specifications. (Acceptable make: System Air / Advance Aircool / Caryaire)
SUB HEAD - 2 (AMC) (Supplementary agreement shall be formed after DLP) under ARMO Fund Comprehensive (Routine, Preventive and Breakdown) maintenance of 11 x 11.0 TR & 7 x 8.5 TR Ductable Type AC unit including its all accessories, condensers, evaporator units, time to time checking of refrigerant leakage, electrical circuits, etc. for smooth operation of the entire AC units during the defect liability period of 1 year after date of commissioning as per maintenance schedule. (No payment shall be made separately for this period): 1st Year
Comprehensive (Routine, Preventive and Breakdown) maintenance of 11 x 11.0 TR & 7 x 8.5 TR Ductable Type AC unit including its all accessories, condensers, evaporator units, time to time checking of refrigerant leakage, electrical circuits, etc. for smooth operation of the entire AC units after defect liability period of 1 year from the date of commissioning as per maintenance schedule. Any breakdown shall be attended within 4 hours of reporting. Spare parts required during breakdown maintenance shall be arranged and replaced by the Contractor. This is applicable for the whole system of AC units installed. (N.B.: 01 Job means during a period of one year)
2nd year (For 12 months)
3rd year (For 12 months)
4th year (For 12 months)
5th year (For 12 months)
6th year (For 12 months)
SMD Solutions (BID ID -3222083)
HONEY COLLECTION (BID ID -3222370)
JUHI AND JAI CONTRACTORS PVT LTD (BID ID -3225958)
TRANSCEND CONTRACTS PVT. LTD. (BID ID -3218730)
Utility Services (BID ID -3224897)
Mvac Engineers (BID ID -3224600)
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.98 MB
BOQ_904383.xls
BOQ • 0.29 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .