Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.5 LAccepted-AOC | L1 | Accepted-AOC Being L1 Bidder | |
| 2 | L2₹14.0 L+₹53,549 (3.97%)Rejected-AOC WZ 409 0 B 1ST FLOOR PLOT NO 12 JANAK PARK HARI NAGAR NEW DELHI 110064 | NEW DELHI | WEST DELHI | DELHI | 110064 | L2 | Rejected-AOC Not L1 Bidder | |
| 3 | L3₹26.0 L+₹12.5 L (92.7%)Rejected-AOC 801802 SAKAR IV OPP MJ LIBERARY ELLISBRIDGE ASHRAM ROAD AHMEDABAD AHMEDABAD GUJARAT 380006 | 801802 | L3 | Rejected-AOC Not L1 Bidder | |
| 4 | Rejected-Technical | - | Rejected-Technical Not Found in order | |
| 5 | Rejected-Technical 205 PARSHAV VIHAR PLOT NO 50 IP EXTN PARPARGANJ DELHI 110092 | EAST | DELHI | 110092 | - | Rejected-Technical Not Found in order |
Tender Value
Refer Docs
EMD Value
₹28,660
Closing Date
21 Jun 2021, 6:00 pmClosed
GE U WATER SUPPLY DELHI CANTT 10
GE U WATER SUPPLY DELHI CANTT 10
PROVN OF SCADA SYSTEM FOR WATER SUPPLY NETWORK AT NOM VARUNA MESS UNDER GE U WATER SUPPLY DELHI CANTT 10
2021_MES_446652_1
GE/WS/D-29 of 2021-22
Open Tender
Civil Works
Item Rate
120 days
GE U WATER SUPPLY DELHI CANTT 10
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE U WATER SUPPLY DELHI CANTT 10
₹28,660
Yes
26 Jun 2021
29 May 2021
23 Jun 2021
29 May 2021
21 Jun 2021
9 Jun 2021
Amount
Enclosure for SCADA RTUV 400mm x 400mm x 200mm (minimum) fabricated from 1.6mm thick CRCA sheet and must be powder coated.
S&F of electromagnetic type flow meter suitable for 100 NB, with IP66 protection,1.4KV isolation, accuracy of 0.5% of MV, linearity of 0.5% of MV, mounting in horizontal, 10kg/Sqcm max pressure local indication through LCD display and RS485 Modbus RTU communication protocol, capable of working in ambient temperature of 0 degree Centigrade to 75 degree Centigrade and humidity up to 95% with response time of less than 1 sec, working on 90-250V AC, 50Hz including necessary welding work, cutting of existing MS/DI/CI/GI pipe line and inserting new 200mm bore MS pipe with necessary MS beds and straight pipe up to 6mtr and connecting with existing pipe line with necessary flanges, nut, bolts, gasket and DI/CI specials complete all as specified and as directed.
RS 485 Communication Cable Two pairs stranded (7*32) tinned copper conductors, polyethylene insulation, twister pairs, Aluminum/Polyester 100% coverage, Tinned copper braid shield 90% coverage, 24 AWG strained tinned copper drain wire, PVC jacket Outer Jacket: Polyvinyl Chloride, 0.34 in Conductor DCR: 24 Ohms/ 1000 ft Nominal Outer Shield DCR: 2.2 Ohms / 1000 ft Nom Capacitance Conductor to Conductor: 12.8pF/ ft Nom Capacitance Conductor to other Conductor to shield: 23 pF/ ft Nominal Characteristic Impedance: 120 Ohms Frequency: 1 MHz Nom Insertion Loss: 0.6 DB/ 100m
S&F of ultrasonic type water level sensor for underground tank suitable for up to 6 meter water level depth of U/G sump, with dead band of less than 0.6meter, IP66 protection, accuracy of 0.25% of F.S. and RS485 Modbus RTU communication protocol, Capable for working in ambient temperature of 0 degree Centigrade to 75 degree Centigrade, non-condensing at 25 degree Centigrade and humidity up to 95% with response time of less than 1 sec with 230VAC to 24VDC, 50Hz power supply, LCD display type, vertical type mounting on top of OHTs with all connections and fixing including clamp, nut-bolt etc complete all as specified and as directed.
S&F of SCADA Ready ultrasonic type water meter for 50 mm Lines of A,B,C Block. The meters will have inbuilt battery with minimum life of 08 Years. (OEM Certification Mandatory). Permanent Flow rate 2.5 Cu Mtr/Hr, Max flow rate: 3.125 Cu Mtr/ Hr Pressure Class: PN16, Temp Class: T50, Protection: IP 68 With LoRa RF.
S&F of SCADA Ready ultrasonic type water meter for 25-35 mm Lines of Ranvir Block, Swaraj Block, Canteen, Sports Complex, VARDHI, Main Bldg, Rana Block and Sailor Block. The meters will have inbuilt battery with minimum life of 08 Years. (OEM Certification Mandatory). Permanent Flow rate 2.5 Cu Mtr/Hr, Max flow rate: 3.125 Cu Mtr/ Hr Pressure Class: PN16, Temp Class: T50, Protection: IP 68 With IP 68 With LoRa RF.
Multifunction Meter with RS 485 port, Modbus RTU for integration with energy management system True RMS electrical parameters: per phase voltage, current, demand, W, VA, VAr Integrated parameters: kWh, kVARh, kVAh Neutral current, frequency, Power factor, % Load, % Unbalance (V&I), Phase angle Total Harmonic Distortion (THD) measurement for both Voltage and Current circuit, per phase Monitoring of active/ apparent power & energy consumption, load current, Run hours, ON hours in single meter with simultaneous display of Amps, Volts, Frequency and Power factor. Class 1.0, 0.5, 0.5S & Cl 0.2 meters as per IEC 62052-11, 62053-21, 62053-23 & ANSI Cl 12.20
CT For 3 phase Multi Function Meters
Single Pole MCB 6A for Multi Function Meters
2.5 mm 2 Core PVC Insulated multi strand copper cable
SCADA Cloud and Internet Subscription for 2 Year with SCADA Software for receiving station Must have user customizable dashboards and SLD (without any coding/ scripting) Reporting must be user-configurable and changeable. Utility like billing reports must be supported. Multi-site data viewing within same interface without any physical cable connection of sites to SCADA room SCADA must be accessible over internet and must have adequate security with dual factor authentication with username/ password alongwith OTP on email. All device communication with Cloud based SCADA must be secured using TLS/SSL encryption. SCADA must not support non-secure connections. System must work without any need of static IP. No static IP will be provided for any location. The web-based software must be hosted in a MEITY ( Ministry of Electronics & Information Technology) approved data center, empanelled under Meghraj initiative of Govt of India. The cloud Service Provider shall provide a Non Disclosure Agreement, mandatory for Ministry of Defence establishments as prescribed in Guidelines for Government Departments On Contractual terms related to Cloud Services, Meghraj Cloud Initiative of Ministry of Electronics & Information Technology, Govt of India
SCADA SUBSCRIPTION for Water Meters Each with 1 Years Subscription of internet Connectivity and Cloud Server as per GOI guidelines with SCADA Software for receiving station Must have user customizable dashboards and SLD (without any coding/ scripting) Reporting must be user-configurable and changeable. Utility like billing reports must be supported. Multi-site data viewing within same interface without any physical cable connection of sites to SCADA room SCADA must be accessible over internet and must have adequate security with dual factor authentication with username/ password alongwith OTP on email. All device communication with Cloud based SCADA must be secured using TLS/SSL encryption. SCADA must not support non-secure connections. System must work without any need of static IP. No static IP will be provided for any location. The web-based software must be hosted in a MEITY ( Ministry of Electronics & Information Technology) approved data center, empanelled under Meghraj initiative of Govt of India. The cloud Service Provider shall provide a Non Disclosure Agreement, mandatory for Ministry of Defence establishments as prescribed in Guidelines for Government Departments On Contractual terms related to Cloud Services, Meghraj Cloud Initiative of Ministry of Electronics & Information Technology, Govt of India
Installation Charges for SCADA System
Flint India
CIMCON SOFTWARE INDIA PVT. LTD.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .