Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical | Admitted-Fee/PreQual/Technical |
| 2 | Admitted-Fee/PreQual/Technical | Admitted-Fee/PreQual/Technical |
| 3 | Admitted-Fee/PreQual/Technical | Admitted-Fee/PreQual/Technical |
Tender Value
Refer Docs
EMD Value
₹5,300
Closing Date
11 Aug 2026, 2:00 pmClosed
AE/SSKM(H.)ESD, PWDte.
244 A.J.C. Bose Road
Electrical Installation Work.
2026_WBPWD_5017650_1
WBPWD/SSKM(H.)ESD/NIQ-21 of 2026-27
Open Tender
ELECTRICAL WORKS ORG
Item Rate
15 days
Kolkata
Please refer Tender documents.
4 documents required · 4 mandatory
₹5,300
10 Sept 2026
30 Jul 2026
13 Aug 2026
4 Aug 2026
11 Aug 2026
5 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supplying and fixing double door 4 way Vertical TPNMCB Distribution board for MCCB (Breaking capacity 25kA/35kA with fixed thermal and fixed magnetic / adjustable thermal and fixed magnetic setting) as incomer with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish incl. Interconnection with suitablesize of copper wire and neutral link & provision for earthing attachment with 160A MCCB as incommer and 2 Nos 63 A TP MCB and 2 Nos 32A TP MCB (10 KA, C ) as outgoing including necessary connection as required. (All Legrand make) | 1 | Set | - | - |
| 2 | Supplying and fixing double door sheet steel (16SWG), powde rcoated cable end box for TPN DB horizontal / vertical enclosurewith IP-42/43 protection, on angle ironframeon wall & mending good the damagestooriginal finish with nuts bolts etc incl. provision for earthing attachment. | 2 | Set | - | - |
| 3 | Supply of 4 Core 95 Sq mm XLPE Insulated & Sheathed Armoured stranded Aluminium Conductor cables for Working Voltage up to 1100 Volts of following sizes [Make:Polycab/RR /KEI/ Havells/ Gloster as approved by E.1.C] | 45 | RM | - | - |
| 4 | Laying of Core 95 Sq mm XLPE Insulated & Sheathed Armoured stranded Aluminium Conductor cables on wall as per direction of EIC. | 45 | RM | - | - |
| 5 | Supplying and fixing compression type gland and finishing those for following XLPE / PVC armoured cable (2 / 4 / 3.5) Core as per GS.
4 Core 95 Sq. mm | 2 | Set | - | - |
| 6Distribution wiring in 1.1 KV single core stranded 'FRLSH' PVC insulated & unsheathed copper wire (Havells/Polycab/KEI/Gloster) in suitable size PVC rigid conduit 'FR' (Precision/Polycab make, HMS/MMS type) incl. necy. fittings as required | |||||
| 6.1 | 3 x 1.5 sqmm (for separate plug points) | 160 | RM | - | - |
| 6.2 | 2 x 2.5 sqmm+1x1.5 sqmm (Computer points in proposed nursing area) | 185 | RM | - | - |
| 6.3 | 4 x 6 sqmm + 2 x 4 sqmm ECC (for heater) | 20 | RM | - | - |
| 6.4 | 4 x 10 sqmm + 2 x 6 sqmm ECC (for AHU Panel) | 35 | RM | - | - |
stage.html
html • 0.03 MB
tech_bid_open.pdf
cancelled_1.pdf
pdf • 0.54 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.33 MB
BOQ_5087978.xls
BOQ • 0.25 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .