| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹17.8 LAccepted-AOC KE 100 B KAVERI KUNJ PHASE I KAMLA NAGAR AGRA 282005 | AGRA | AGRA | UTTAR PRADESH | 282005 | L-1 | Accepted-AOC Being L1 | |
| 2 | L-2₹20.0 L+₹1.6 L (8.48%)Rejected-Finance | L-2 | Rejected-Finance Being other than L-1 | |
| 3 | L-3₹20.5 L+₹2.1 L (11.2%)Rejected-Finance 111 YADAV ELECRIC MARKET GB MARG LUCKNOW LUCKNOW UTTAR PRADESH 226018 | LUCKNOW | UTTAR PRADESH | 226018 | L-3 | Rejected-Finance Being other than L-1 | |
| 4 | L-4₹21.5 L+₹3.1 L (16.6%)Rejected-Finance | L-4 | Rejected-Finance Being other than L-1 | |
| 5 | L-5₹22.0 L+₹3.5 L (19.2%)Rejected-Finance NAGLA UDHA NEAR PRIMARY SCHOOL POST DHANOLI AGRA UP AGRA 282010 | AGRA | AGRA | UP | 282010 | L-5 | Rejected-Finance Being other than L-1 |
| Sl No | Description | Qty | Unit | Industrial Traders L3 | Balaji Associate L2 | TRIVENI ASSOCIATES L6 | BUILDTECH ASSOCIATES L4 | MUKTA AND COMPANY L5 | M/s Sumer Associates L1 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Excavation in trenches in soft/loose soil not exc 1.5m wide and not exc 1.5m depth for laying of cable, errection of poles, stay and pipe line,and getting out complete all as specified and directed. | 700 | Cum | 310 ₹2,17,000 | 100 ₹70,000 | 150 ₹1,05,000 | 100 ₹70,000 | 150 ₹1,05,000 | 90 ₹63,000 Lowest |
| 2.00 | Returning & filling including spreading, leveling watering and well ramming in layers not exc 25 cm thick in any type of soil complete all as specified and directed. | 600 | Cum | 113 ₹67,800 | 45 ₹27,000 | 65 ₹39,000 | 10 ₹6,000 Lowest | 50 ₹30,000 | 40 ₹24,000 |
| 3.00 | Removal of excavated soil to a distance not exc. 50 m above the starting point complete all as specified and directed. | 100 | Cum | 260 ₹26,000 | 55 ₹5,500 | 51 ₹5,100 | 10 ₹1,000 Lowest | 50 ₹5,000 | 30 ₹3,000 |
| 4.00 | Supply & laying double walled corrugated (DWC) HDPE full rounded pipe in 6 m lenght conforming to IS 16205 Pt-24 of approved colour complete with fittings for cable protection of size 75 mm outer dia and 63 mm inner dia complete all as specified and directed. | 800 | RM | 106 ₹84,800 | 80 ₹64,000 Lowest | 125 ₹1,00,000 | 90 ₹72,000 | 85 ₹68,000 | 80 ₹64,000 Lowest |
| 5.00 | Supply & laying double walled corrugated (DWC) HDPE full rounded pipe in 6 m lenght conforming to IS 16205 Pt-24 of approved colour complete with fittings for cable protection of size 63 mm outer dia and 50 mm inner dia complete all as specified and directed. | 2,050 | RM | 73 ₹1,49,650 | 70 ₹1,43,500 | 101 ₹2,07,050 | 80 ₹1,64,000 | 65 ₹1,33,250 Lowest | 80 ₹1,64,000 |
| 6.00 | M & L for drilling suitable dia horizontal bore holes for insertion/ laying of 50 to 350 mm bore GI/HDPE tubing of any description below/ under road surface/ floors etc with using mechanical or manual devices as required at site complete all as specified and directed. | 60 | RM | 406 ₹24,360 | 320 ₹19,200 | 500 ₹30,000 | 300 ₹18,000 Lowest | 500 ₹30,000 | 310 ₹18,600 |
| 7.00 | Supply laying & testing for XLPE LT UG cable PVC insulated, bedded armoured heavy duty electric cable 1100 volts grade with aluminum conductor of of cable 50 Sqmm 3.5 Core, including taking down the unserviceable UG cable complete all as specified and directed. | 500 | RM | 274 ₹1,37,000 Lowest | 440 ₹2,20,000 | 450 ₹2,25,000 | 450 ₹2,25,000 | 380 ₹1,90,000 | 375 ₹1,87,500 |
| 8.00 | Supply laying & testing for XLPE LT UG cable PVC insulated, bedded armoured heavy duty electric cable 1100 volts grade with aluminum conductor of of cable 70 Sqmm 3.5 Core, including taking down the unserviceable UG cable complete all as specified and directed. | 500 | RM | 361 ₹1,80,500 Lowest | 525 ₹2,62,500 | 600 ₹3,00,000 | 550 ₹2,75,000 | 510 ₹2,55,000 | 500 ₹2,50,000 |
| 9.00 | Supply laying & testing for XLPE LT UG cable PVC insulated, bedded armoured heavy duty electric cable 1100 volts grade with aluminum conductor of of cable 25 Sqmm 4.0 Core, including taking down the unserviceable UG cable complete all as specified and directed. | 800 | RM | 202 ₹1,61,600 Lowest | 235 ₹1,88,000 | 290 ₹2,32,000 | 350 ₹2,80,000 | 250 ₹2,00,000 | 240 ₹1,92,000 |
| 10.00 | Supply laying & testing for XLPE LT UG cable PVC insulated, bedded armoured heavy duty electric cable 1100 volts grade with aluminum conductor of of cable 16 Sqmm 4.0 Core, including taking down the unserviceable UG cable complete all as specified and directed. | 1,800 | RM | 158 ₹2,84,400 Lowest | 182 ₹3,27,600 | 210 ₹3,78,000 | 220 ₹3,96,000 | 200 ₹3,60,000 | 180 ₹3,24,000 |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
4 Feb 2026, 6:00 pmClosed
GE AF Adm Area Agra
GE (AF) Adm Area Agra UP 282008
REPAIR MAINT AND REPLACEMENT OF LT OH LINE TO LT UG CABLES AND CONNECTED WORKS AT 2 AREA NP OFFR AREA UNDER GE AF ADM AREA AGRA
2026_MES_747832_1
8000-2315/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE AF Adm Area Agra
Please refer Tender documents.
4 documents required · 4 mandatory
₹500
GE AF Adm Area Agra
₹50,000
26 May 2026
15 Jan 2026
6 Feb 2026
15 Jan 2026
4 Feb 2026
29 Jan 2026
Excavation in trenches in soft/loose soil not exc 1.5m wide and not exc 1.5m depth for laying of cable, errection of poles, stay and pipe line,and getting out complete all as specified and directed.
Returning & filling including spreading, leveling watering and well ramming in layers not exc 25 cm thick in any type of soil complete all as specified and directed.
Removal of excavated soil to a distance not exc. 50 m above the starting point complete all as specified and directed.
Supply & laying double walled corrugated (DWC) HDPE full rounded pipe in 6 m lenght conforming to IS 16205 Pt-24 of approved colour complete with fittings for cable protection of size 75 mm outer dia and 63 mm inner dia complete all as specified and directed.
Supply & laying double walled corrugated (DWC) HDPE full rounded pipe in 6 m lenght conforming to IS 16205 Pt-24 of approved colour complete with fittings for cable protection of size 63 mm outer dia and 50 mm inner dia complete all as specified and directed.
M & L for drilling suitable dia horizontal bore holes for insertion/ laying of 50 to 350 mm bore GI/HDPE tubing of any description below/ under road surface/ floors etc with using mechanical or manual devices as required at site complete all as specified and directed.
Supply laying & testing for XLPE LT UG cable PVC insulated, bedded armoured heavy duty electric cable 1100 volts grade with aluminum conductor of of cable 50 Sqmm 3.5 Core, including taking down the unserviceable UG cable complete all as specified and directed.
Supply laying & testing for XLPE LT UG cable PVC insulated, bedded armoured heavy duty electric cable 1100 volts grade with aluminum conductor of of cable 70 Sqmm 3.5 Core, including taking down the unserviceable UG cable complete all as specified and directed.
Supply laying & testing for XLPE LT UG cable PVC insulated, bedded armoured heavy duty electric cable 1100 volts grade with aluminum conductor of of cable 25 Sqmm 4.0 Core, including taking down the unserviceable UG cable complete all as specified and directed.
Supply laying & testing for XLPE LT UG cable PVC insulated, bedded armoured heavy duty electric cable 1100 volts grade with aluminum conductor of of cable 16 Sqmm 4.0 Core, including taking down the unserviceable UG cable complete all as specified and directed.
M&L Earthing complete with 60cm x 60cm x 6 mm thick GI plate electrode buried in ground vertically not less than 2.25mtrs deep below ground level with top edge of the plate not less than 1.5mtrs below ground level with GI wire 4.0mm dia as earthing lead including necessary excavation and earth work (in any of strata) providing charcoal dust, salt mixed with fine sand in continuous layers, PCC (1:3:6 ) type C1 in chember ,Precast 50 mm thick in cement ( 1: 2:4) type B.1 with CI frame with cover, 20mm dia bore light grade GI watering pipe furnel etc fixing of GI Pipe 40 mm bore protection for earthing strip from earth pit to test point complete & making connection all as specified in Electrical plate No 3 complete all as specified and directed.
M&L form preparation of steel surface of electric pole upto 11 Mtr long extension portion, apply one coat of aluminum paint over full length and marking of pole number and five strips as per approved colour by the departmetn using synthetic enamel paint complete all as specified and directed.
M&L Point wiring for one light/ fan/exhaust fan point controlled by one way switch with Multi stranded copper conductor size 1.5 sqmm PVC insulated, unsheathed,FRLS cable , 1100 volts grade conforming to IS 694 multistranded , drawn in rigid PVC type conduit concealed in walls / floors/ ceiling etcwith and including metal flush boxes of suitable size and modular white plate with frame for mounting of fittings, modular type switches, regulator and also including 1.5 sqmm PVC insulated unsheathed copper cable green in colour as continuous earth continuity conductor and connecting to earth dolly,cutting chasis to the walls/ floors/ ceiling and repairing with existing surface after work ,complete including taking down carefully U/S aluminium/ copper point wiring (light, fan,socket or power) complete with fittings such as switches, sockets, ceiling rose, light fittings etc complete all as specified and directed.
All as per item no -13 here in above for one three pin socket outlet 6 amps socket on the same board with other switches
All as per item no -13 here in above for one 3 pin socket point 5 Amps on the independent board.
All as per item no -13 here in above but using copper conductor 2.5 sqmm PVC insulated unsheathed FRLS cable with copper conductor size 1.5 sqmm PVC insulated unsheathed continuous earth continuity for 3 pin 15 amps socket outlet independently complete all as specified and directed.
Supply & fix switch modular type single pole 1 way 5 Amp 230 volt complete all as specified and directed.
Supply & fix socket 6 Amps modular type, 230 volts grade complete all as specified and directed.
Supply & fix switch modular type 1 way 16A, 1 module complete all as specified and directed.
Supply & fix Socket Modular type 6A/16A 2-3pin combined 2 module 230Volts grade complete all as specified and directed.
Supply & fix ceiling rose surface bakelite two to three terminal complete all as specified and directed.
Supply and fix in replacement of LED type 4 feet tube light fitting surfac mounted of 25 Watts decorative ultra slim polycarbonate LED lighting fixture with high lumen output, envioronmental friendly energy efficient ready to use pack complete all as specified and directed. Make :Havells Cat Part No :LHEXAWP7IN1W025 or equivalent in CG/BAJAJ/Phillips
Supply and fix in replacement of 50 Watt LED street light with pressure die cast housing with toughened glass and individual LED with secondary optics and IP 66 protection for building security complete all as specified and directed.Make :Havells Cat Part No :LHETAVU7PA7J050 or equivalent in CG/BAJAJ/Phillips
S&F street light brackets suitable for mounting on existing or new poles, made from 40 mm galvanized mild steel pipe/conforming to IS standards. The bracket shall be of single arm design, 1.0 to 1.5 meter in length, with appropriate bend (typically 105° to 120°), including necessary clamps, bolts, nuts, and washers for secure installation on the Building. The bracket shall be duly painted (if not galvanized) with corrosion-resistant paint complete all as specified and directed.
Supply and fix in replacement of MCB DB SPN 8 way DB double door type single phase 230 Volts complete all as specified and directed.
Supply and fix in replacement of MCB SPN 32Amps 230 Volts , C curve single phase all as specified complete all as specified and directed.
Supply and fix in replacement of MCB SP 6-32Amps 230 Volts single phase complete all as specified and directed.
M & L for submain wiring of 2 run 6 Sqmm size PVC insulated unsheathed multistranded copper conductor 1100 Volts FRLS grade drawn through and including suitable size of PVC conduit accessories concealed in wall/roof including one run of 4 Sqmm PVC insulated multistranded copper wire for earth , ISI marked and connecting up complete including removing old unserviceable cables complete all as specified and directed. Note :-(i) One run of PVC conduit, two runs of copper cable and one run of earth wire shall be measured and paid as one unit.
M&L for providing, fabricating, supplying, and installing a Substation Name Board of size 1800 mm × 900 mm × 100 mm (or as approved by the Engineer-in-Charge), made of an extruded aluminium/ SS304 frame with 3–4 mm ACP sheet backing and 3–5 mm UV-stabilized acrylic/polycarbonate front fascia, with the board background in blue colour and all lettering in white colour. The contractor shall submit the substation name, lettering style, colour shade, and final layout for approval by the Engineer-in-Charge before fabrication. The board shall be internally illuminated using high-brightness IP65-rated LED strip/module lighting with constant-voltage LED driver, including FRLS internal wiring, terminals, cable glands, and all required electrical accessories. The enclosure shall be weather-proof (IP54 or better), corrosion-resistant, and suitable for continuous outdoor operation. The name board shall be rigidly fixed on the building wall using heavy-duty GI/SS brackets and stainless-steel fasteners, complete with all supports and finishing. The work includes connection to a nearby power source through an MCB, testing, commissioning, and handing over, complete all as specified and directed.
M&L for providing, fabricating, supplying, and installing a Substation Name Board of size 1200 mm × 600 mm × 75 mm (or as approved by the Engineer-in-Charge), made of an extruded aluminium/SS304 frame with 3–4 mm ACP sheet backing and 3–5 mm UV-stabilized acrylic/polycarbonate front fascia, with the board background in blue colour and the substation name/letters in white colour. The contractor shall submit the name, text style, colour shade, and layout of the board for approval from the Engineer-in-Charge before fabrication. The board shall be internally illuminated using high-brightness IP65 LED strip/module lights with constant-voltage LED driver, complete with FRLS internal wiring, connectors, cable glands, and all necessary electrical accessories. The enclosure shall be weather-proof (IP54 or better), corrosion-resistant, and structurally robust for outdoor conditions. The board shall be firmly fixed on the building wall using GI/SS brackets and stainless-steel fasteners, including all mounting supports and making good the surface. The work includes connection to the nearest power source through an MCB, testing, commissioning, and handing over complete all as specified and directed.
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.33 MB
TenderT69.pdf
Tender Documents • 0.96 MB
BOQ_837464.xls
BOQ • 0.44 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .