| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.0 LAccepted-AOC VILLAGE SATOJ TEHSIL SUNAM DISTT SANGRUR | SANGRUR | PUNJAB | 148001 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹33.0 L+₹2.0 L (6.56%)Rejected-Finance GANDHI CHOWK MANIPURA JAISALMER RAJ 345001 | JAISALMER | JAISALMER | RAJASTHAN | 345001 | L2 | Rejected-Finance Not lowest Bidder | |
| 3 | L3₹34.0 L+₹3.0 L (9.76%)Rejected-Finance | L3 | Rejected-Finance Not lowest Bidder | |
| 4 | L4₹34.1 L+₹3.1 L (10.1%)Rejected-Finance 40 VISHNU VIHAR KHERAI SHAMSHABAD ROAD KHERAI AGRA UTTAR PRADESH 282001 | AGRA | UTTAR PRADESH | 282001 | L4 | Rejected-Finance Not lowest Bidder | |
| 5 | L5₹34.4 L+₹3.5 L (11.3%)Rejected-Finance | L5 | Rejected-Finance Not lowest Bidder |
Tender Value
Refer Docs
EMD Value
₹62,000
Closing Date
28 Dec 2020, 6:00 pmClosed
GE (AF) Jaisalmer
GE (AF) Jaisalmer
Special repair to certain ORs/NCs (E) accommodation at Air Force Station Jaisalmer
2020_MES_380642_3
8695/GE/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
GE (AF) Jaisalmer
As per tender documents
7 documents required · 7 mandatory
₹500
Yes
GE (AF) Jaisalmer
₹62,000
Yes
31 Dec 2020
1 Dec 2020
30 Dec 2020
1 Dec 2020
28 Dec 2020
14 Dec 2020
Amount
S&F coloured glazed ceramic tiles in dado/skirting 450x350x7mm or 350x250x7mm thick on vertical surfaces, dado and skirting over and including 10mm thick cement and sand mortar (1:4) backing coat set and jointed in neat cement slurry and pointed in coloured cement to match the colour of tile and including dismantling floor, hearth or wall tiling including cement mortar bedding complete all as specified and directed
S&F coloured Non Skid ceramic tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm in floors etc over 15mm thick in cement and mortar (1:6) bedding set and jointed in neat cement slurry and pointed in coloured cement to match and including dismantling floor, hearth or wall tiling including cement mortar bedding complete all as specified and directed
M&L for 20-25mm thick green marble machine cut laid in floor surfaces and jointed with grey cement slurry mixed with pigment to match the shade of the slab and including cutting, rubbing and mirror polishing over and including screed bed or bedding layer of 15mm thick in cement and sand mortar 1:6 and including dismantling floor, hearth or wall tiling including cement mortar bedding complete all as specified and directed.
Demolition of cement concrete wall and pavings not exceeding 15cm thickness (below or above ground level) unreinforced complete all as specified and directed by Engr-in-Charge.
M&L for 100mm thick PCC 1:4:8 type D-2 (using 40mm graded stone aggregate) as in sub base of flooring complete all as specified and directed.
M&L for 25mm thick PCC 1:2:4 type B-0 (using 12.5mm graded stone aggregate) as in flooring, finished even and smooth with using extra cement complete all as specified and directed).
M&L for 75mm thick PCC 1:3:6 type C-2 (using 40mm graded stone aggregate) as in plinth protection and flooring complete all as specified and directed.
M&L for 10mm thick plaster in cement (1:6) on stone masonry surface or surface other than fair face of brick work or concrete surface or stone masonry surfaces of wall and including taking down old cement plaster complete all as specified and directed.
M&L for 5mm thick plaster in cement (1:4) on fair face of brick work or concrete surface or stone masonry surfaces of ceiling and including taking down old cement plaster complete all as specified and directed.
M&L for rendering 15mm thick on fair faces of brick work or concrete surfaces in two layers i.e 1st layer 10mm thick in cement and sand mortar (1:6) and 2nd layer 5mm thick in cement and sand mortar (1:4) with water proofing compound and finished even and smooth (without using extra cement) complete all as specified and directed. Note : Water proofing compound shall be measured and paid for separately.
Demolition of reinforced cement concrete any discription and in any position not otherwise specifically provided (reinforcement cut as required to facilitate demolition) complete all as specified and directed
S&F mild steel work as in roof trusses (framed), trussed, purlins, crane gantries, wind ties also screwing with bolts, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats, necessary welding etc. conforming to Gde E-250 (Fe 410-W) quality `A’ complete all as specified and as directed.
S&F 0.80mm thick galvanised corrugated mild steel sheeting class 4 with two corrugation side lap fixed with coach screws and washers, in roofs, walls etc. with grade of zinc coating 275 complete all as specified & as directed.
M&L for squared rubble walling, Jodhpur type regular coursed, well bonded, bedded and solidly hearted, built in cement mortar (1:6) complete as specified and directed.
M&L for preparation of newly plastered or unplastered surfaces and applying two coats of white wash on ceiling surface complete all as specified and directed.
M&L for preparation of newly plastered or unplastered wall surfaces and applying two coats of oil bound distempering over a coat of cement primer and including 3mm thick wall care putty finished even and smooth complete all as specified and directed.
M&L for preparation of newly plastered surface of walls and applying two coats of cement base paint over a coat of alkali resistant priming on surfaces of walls any colour as approved complete all as specified.
M&L for preparation of old painted plastered or unplastered wall surfaces and applying one coat of cement based paint complete all as specified and directed.
M&L for preparation of old painted plastered or unplastered wall surfaces of any description and applying one coat of oil emulsion distemper complete complete all as specified and directed by Engr-in-charge.
M&L for preparation of old decorated surfaces of walls of any description and applying one coat of white wash complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of old decorated surfaces of ceilings of any description and applying one coat of white wash complete all as specified and directed by Engineer-in-Charge.
M&L for cutting chases, pinning in, making good to facings as original where required and pointing in cement mortar 1:3 for concealed water tubing etc. and making good, cutting exceeding 10cm but not exceeding 20 cm girth in stone masonry walls complete all as specified and directed.
M&L for galvanized steel water tubing medium grade of 15mm bore with & including all fittings and complete to walls and ceiling or laid in floors, including taking up or down old unserviceable steel water tubing and connections of 15mm bore, complete all as specified and directed.
Taking up or down steel water tubing and connecting including cleaning and including refixing for 15mm bore old steel water tubing and connection in new or old position including all new fittings and fixtures (wall, ceiling, floor etc) complete all as specified and directed.
M&L for galvanized steel water tubing medium grade of 20mm bore with & including all fittings and complete to walls and ceiling or laid in floors, including taking up or down old unserviceable steel water tubing and connections of 20mm bore, complete all as specified and directed.
Taking up or down steel water tubing and connecting including cleaning and including refixing for 20mm bore old steel water tubing and connection in new or old position including all new fittings and fixtures (wall, ceiling, floor etc) complete all as specified and directed.
Taking down door chowkhats or frame with shutters (without taking off shutters from the frames), area not exceeding 1.50 Sqm each complete all as specified and directed.
Taking down door chowkhats or frame with shutters (without taking off shutters from the frames), area exceeding 1.50 sqm but not exceeding 4.00 sqm each complete all as specified.
S&F steel windows with side hung shutters including box type hinge of size 50mm with 'z' type steel handle and steel peg stay and 02 No.100 mm size MS tower bolts welded on each shutter complete with glazing bars, dovetailed or welded all as specified and directed.
S&F steel ventilator with top hung shutter including hinges, steel peg stay, guard bars 10mm square, MS bars welded @ 175mm centre to centre horizontally, handle including one shop coat of zinc chromate primer complete all as specified and directed.
S&F mild steel work in framed work such as grills, gratings, framed guard bars etc. with ends of bars shouldered and/ or riveted, or forged into spikes, and in ladders, railings, frame of water tank etc.and similar work confirming to Fe-290 Grade E-165 for framed and hung as gates, including pintle hinges, stops, hand-made sliding bolts, etc. complete all as specified and directed.
S&F Second class hard wood plain, solid sraight door chowkats and frames, wrought including transoms or mullions, framed rebatted on the solid, rounded or chamfered, put together with glue pinned at joints all as specified and directed by Engineer-in -Charge
S&F Factory made second class hard wood 35mm thick glazed and skeleton door shutters, open rebated and prepared to receive glass, gauze etc. divided into squares with plain chamfered or rounded, mitred and rebated sash bars any numbers, edges of framing plain, chamfered or founded, fitted with cut and mitred beads for securing glass or wire cloth any number, etc sizes of members of shutter as specified in SSR Part-I.
S&F factory made 35mm thick second class hard wood plain framed, paneled shutter (Two panels) with lock rail and panel of 9mm thick BWP commercial ply or 12mm thick veneered particle board with commercial veneering on both faces, size of rail and styles as per IS : 1003 (Part-I), kiln seasoned and chemically pressure treated using second class hard wood rail and styles, fixed to chowkat, complete all as specified.
S&F factory made solid panel PVC door shutter 30mm thick (style), consisting of frame made out of MS tubes for stiles and for top & bottom rails. MS frame shall be covered with heat moulded plain colour PVC profile ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheet for top rail, lock rail and bottom rail on either side and as gap insert for top rail and bottom rail. Panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles and rails with suitable PVC sheet beading and joined together with solvent cement complete all as specified.
S&F Solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube and PDM rubber gasket weather seal to be provided through out the frame. The profile shall be mitre cut at two corners and jointed by inserting 02 Nos of 150mm long brackets of MS square tube inside the MS square tube and suitably screwed complete all as specified.
S&F in replacement of stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed.
Supply only stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed.
M&L for Plain cement concrete (1:3:6) type C-1 (using 20 mm graded stone aggregate) as in hold fast, parapets, copings, bed plates, surfaces channels, drains and like including weathering slightly rounded or chamfered angles and throating, necessary formwork as required etc complete all as specified and directed.
S&F 3mm thick sheet glass ordinary quality and glazing with oil putty not exceeding 0.50 sqm in each pane including Hacking out broken glass (any thickness, size, quality or description) from wooden/steel or stone, concrete or brick surrounds, glazed with putty or fixed with beads and fixing new ones complete all as specified and directed
S&F 3mm thick frosted sheet glass ordinary quality and glazing with oil putty in squares not exceeding 0.50 sqm each pane including Hacking out broken glass (any thickness, size, quality or description) from wooden/steel or stone, concrete or brick surrounds, glazed with putty or fixed with beads and fixing new ones complete all as specified and directed.
S&F 150mm long mild steel barrel tower bolts, stove enamelled black, with bright bolt complete all as specified.
S&F 200mm long mild steel barrel tower bolts, stove enamelled black, with bright bolt complete all as specified.
Supply and fixing 300mm long mild steel sliding door bolts clip type, stove enameled black, with bright bolt not less than 12mm dia and including a minimum of 06 bolts and nuts, four on bolt plate and two on staple plate and fixed, ISI marked complete all as specified and directed.
S&F in replacement of butt hinges of size 100mm, medium weight, cold rolled mild steel ISI marked complete all as specified and directed.
S&F mild steel pressed handles ovel type stove enameled black 150mm long complete all as specified.
M&L for prepariation of newly or previously untreated steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
M&L for preparation of old painted steel surfaces of any discription over exceeding 10cm in width or girth not other wise described and applying one coat of synthetic enamel paint complete all as specified and directed.
M&L for preparation of new surfaces of wood or wood based materials of any description over 10 cm width or girth and applying two coats of synthetic enamel paint of approved tint over a coat of pink primer complete all as specified and directed.
M&L for preparation of old painted wooden surfaces of any description exceeding 10cm width or girth and applying one coat of synthetic enamel paint of any tint etc complete all as specified and directed
Demolition of brickwork or stone/boulder masonry built in cement mortar including all quoins, arches, pillars,etc, but excluding ashlar facings, dressed stone work and precast concrete articles complete all as specified.
M&L for precast cement concrete (1:3:6), type C-1 (using 20 mm graded stone aggregate) solid block masonary exceeding 10cm and set in cement and sand mortar (1:6), complete all as specified and directed.
M&L for cutting holes in brick walls/stone masonry built in cement mortar for inserting hold fasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4, exceeding one brick & not exceeding two bricks (Depth of embedded portion of holdfasts or lugs measured from the face of the jamb into the wall) complete all as specified and directed.
S&F in replacement of stainless steel plate rack 0.63mm thick of size 600x600x250mm for kitchen fixing stainless steel screw on wall properly complete all as specified & directed
S&F in replacement of Vitreous china squatting pan 'Orissa Pattern' of size 580x440mm white with integral foot rest (excluding flushing cistern and flush pipe) with P' or 'S' trap complete including jointing and making good to floor provision of PCC 1:5:10 bed as in repairs complete all as specified and directed.
S&F in replacement of vitreous china wash hand basin white flat back of size 450x330mm with including a pair of cast iron brackets embedded in PCC 1:3:6 type C-1 blocks of size 10x7.5x15cm with fixed complete all as specified.
S&F in replacement of LDPE waste pipes of 32mm bore pressure rating 6 Kg/Sqcm for wash basin complete all as specified.
Supply only 15mm dia pillar taps, cast copper alloy with capstan heads, chromium plated, screwed down high pressure with or without lettered 'Hot or cold' long screwed shanks and fly nuts, screwed for iron pipe complete all as specified and directed.
S&F in replacement of 10 litres capacity PVC valve less syphonic action type, low level flushing cistern, white coloured, with inlet ball valve float and handle including brackets, polythylene flush pipe etc complete all as specified and directed.
S&F as in repairs Towel rail 450mm long of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 170gms) all as directed. Make : Prayag, Polytuf, Jindal
S&F in replacement of 15mm bore fancy type chromium plated Bib taps, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed.
S&F in replacement of 15mm bore fancy type chromium plated Bib taps long body, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed.
S&F in replacement of 15mm bore stop cock, chromium plated (concealed type) cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed.
S&F in replacement of 15mm bore CP angle cock, fancy type chromium plated, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed.
Supply and fixing in replacement of PVC connection 450 mm long suitable for 15mm bore Galvanised Iron pipe including PTMT nuts on both sides complete all as specified.
Supply and fixing in replacement of 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified.
Supply and fixing in replacement of 75mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified.
S&F in replacement of 110mm bore PVC (SWR) bend any radius provided with access door.
S&F in replacement of 75mm bore PVC (SWR) bends any radius provided with access door
S&F in replacement of PVC floor trap with out let 75mm dia plain with grating including jointing complete all as specified and directed.
S&F as in repair shower rose, PVC suitable for 15 mm bore pipe with swieveling joints, size -75mm or 110mm complete all as specified.
S&F in replacement of sink made of stainless steel 1.00 mm thick for Kitchen or laboratory with plugs, washers and wastes including bedding in cement mortar to dwarf wall or incl fixing cantilever brackets and connecting union to pipe over all size 495mm x 420mm, bowl size 410mm x 330mm complete all as specified.
M&L cutting out cracks to V-section in existing roofs or terracing, cleaning out, wetting, grouting with cement and sand slurry 1:3 complete all as specified and as directed.
M&L for applying evenly a tack coat of industrial bitumen 85/25 grade at the rate of 0.60 Kg per sqm including cleaning surfaces and including 10mm thick plaster in cement (1:4) with water proofing compound over green concrete sufaces finished even and smooth (without using extra cement) (WPC will be measured and paid for seperately) and including dismantling of existing water proofing roof treatment any type and if any location upto existing RCC slab by chiesling, drilling, scraping etc complete all as specified and directed.
M&L for APP based polymeric membrane minimum weighing 3.0 Kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (weight not less than 150 gms/sqm) land on primed surface by forced application complete all as specified and directed.
Supply only integral water proofing compound (ISI marked).
Disconnecting & taking down the existing unserviceable water tank not exceeding 1000 Litre capacity, setting aside (or lowering if required) for repair, cleaning etc and same re-fixing in old position & making necessary arrangements complete as specified in SSR Part-I.
S&F 500 Litre capacity Rotational moulded polyethylene water storage tanks, two layered, white coloured (cylindrical vertical with closed top), ISI marked, hoisted & fixed in position and including disconnecting & taking down the existing unserviceable water tank complete all as specified and directed.
Fixing only 500 Litre capacity Rotational moulded polyethylene water storage tanks, two layered, white coloured (cylindrical vertical with closed top), hoisted & fixed in position complete all as specified and directed.
S&F in replacement of MCB, 6 to 32 Amp, Single Pole, 240 Volt, repturing capacity 10 kA, ‘C’ Curve, complete all as specified. Make : Legrand Cat Part No. 4085 95 or equivallent
S&F in replacement of MCB, 40 Amp, Single Pole with Neutral, 240 Volt, repturing capacity 10 kA, ‘C’ Curve, complete all as specified. Make : Legrand Cat Part No. 4086 18 or equivallent.
S&F in replacement of MCB, 63 Amp, Three Pole, 415 Volt, repturing capacity 10 kA, ‘C’ Curve, complete all as specified. Make : Legrand Cat Part No. 4086 61 or equivallent.
S&F in replacement of MCB, 40 Amp, Three Pole with Neutral, 415 Volt, repturing capacity 10 kA, ‘C’ Curve, complete all as specified. Make : Legrand Cat Part No. 4086 20 or equivallent.
M&L for point wiring for one light point controlled by one, one way 5/6 Amp switch with 1.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor Flame Retardant Low Smoke (FRLS) cable 1100 Volt grade including 1.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade as continuous earth wire in green colour to common earth and connected to earth dolly laid/drawn into and including non metalic rigid PVC conduit 20mm dia with accessories fixed to cutting chases in walls by cutter and making good surface in cement and sand mortar 1:3 and to the original specification and PVC conduit on ceiling for steel structure/surfaces conduit with clamps, gutties etc for RCC ceiling with including cast iron/pressed steel/wooden terminal boxes (as per site requirement) including providing new 3mm thick plastic laminated sheet cover (Hylem) and including taking down old unserviceable point wiring complete all as specified. Note : (i) Unit rates quoted by contractor shall be deemed to included for cutting chases in walls, ceilings and making good surfaces in cement and sand mortar (1:3) and finishing the surfaces to match with existing surfaces. (Make : Hylem/Anchor/Formica including machine screws and washer etc for fixing switches sockets etc including 1.5 sqmm copper conductor, standard (green colour earth), PVC insulated unsheathed earth wire to commen earth and connected to earth dolly as specified and directed by Engineer-in-Charge.
All as per serial item No. 85.00 here-in-before but for one fan point controlled by one switch and regulator.
All as per serial item No. 85.00 here-in-before but for one 3 Pin, 5/6 Amps, socket outlet controlled by one 5/6 Amps switch on independent board.
All as per serial item No. 85.00 here-in-before but for one 3 Pin, 5/6 Amps, socket outlet controlled by one 5/6 Amps switch on same board.
All as per serial item No. 85.00 here-in-before but for One bell point controlled by one bell push.
All as per serial item No. 85.00 here-in-before but for one light point controlled by two, two way switches.
M&L for point wiring for one 6 pin controlled by 15/16 Amp socket outlet with 2.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor Flame Retardant Low Smoke (FRLS) cable 1100 Volt grade including 2.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade as continuous earth wire in green colour to common earth and connected to earth dolly laid/drawn into and including non metalic rigid PVC conduit 20mm dia with accessories fixed to cutting chases in walls by cutter and making good the surface in cement and sand mortar 1:3 and to the original specification and PVC conduit on ceiling for steel structure/surfaces conduit with clamps, gutties etc for RCC ceiling with including cast iron/pressed steel/wooden terminal boxes (as per site requirement) including including providing new 3 mm thick plastic laminated sheet cover (Hylem) and including taking down old unserviceable point wiring complete all as specified and directed. Note : (i) Unit rates quoted by contractor shall be deemed to included for cutting chases in walls, ceilings and making good surfaces in cement and sand mortar (1:3) and finishing the surfaces to match with existing surfaces. (Make : Hylem/Anchor/Formica including machine screws and washer etc for fixing switches sockets etc including 2.5 sqmm copper conductor, standard (green colour earth), PVC insulated unsheathed earth wire to commen earth and connected to earth dolly as specified and directed by Engineer-in-Charge.
S&F in replacement of switch piano, flush type, single pole, one way, 5/6 Amp, 230 Volts (ISI Marked).
Supply and fixing in replacement of socket outlet, 2 in 1, 3 pin, 5/6 Amp, flush type, (ISI Marked), 240 Volts.
S&F in replacement of switch piano, flush type, single pole, one way, 15 Amp, 230 Volts (ISI Marked).
S&F in replacement socket outlet 2 in 1, 3 pin, 15 Amps flush type, (ISI Marked), 240 Volts.
Supply and fixing in replacement of switch piano, flush type, single pole, two way, 5/6 Amp (ISI Marked), 230 Volts.
Supply and fixing in replacement of bell push, flush type, single pole, 5 Amp, (ISI Marked) 230 Volts.
Supply and fixing in replacement of Bell Multi Music Type, AC, 230 Volts, single pole, (ISI Marked).
Supply and fixing stepped type electronic fan regulator, flush type and connecting up, ISI marked, 240 Volts including taking down unserviceable complete all as specified.
Supply and fixing in replacement of ceiling rose surface bakelite 65mmx17.5mm with two or three terminal PVC/Polycarbonate, isolated body (ISI Marked) complete all as specified.
M&L for Sub main wiring with 2x4.00 sqmm, single core, PVC insulated unsheathed multistranded copper conductor Flame Retardant Low Smoke (FRLS) 1100 volts grade conforming to IS 694 including and 4.00 Sqmm single core PVC insulated and unsheathed multistranded copper conductor Flame Retardant Low Smoke (FRLS) cable 1100 Volt grade as continuous earth wire in green colour including drawn through in 25mm dia PVC conduit including taking down old unserviceable submain wiring complete all as specified and directed. Note : Two run of 4.00 sqmm cable and one run of 4.00 sqmm cable as earth wire continuity conductor and one run 25mm dia PVC conduit shall be measured & paid as one unit.
M&L for Sub main wiring with 2x6.00 sqmm, single core, PVC insulated unsheathed multistranded copper conductor Flame Retardant Low Smoke (FRLS) 1100 volts grade conforming to IS 694 including and 6.00 Sqmm single core PVC insulated and unsheathed multistranded copper conductor Flame Retardant Low Smoke (FRLS) cable 1100 Volt grade as continuous earth wire in green colour including drawn through in 25mm dia PVC conduit including taking down old unserviceable submain wiring complete all as specified and directed. Note : Two run of 6.00 sqmm cable and one run of 6.00 sqmm cable as earth wire continuity conductor and one run 25mm dia PVC conduit shall be measured & paid as one unit.
S&F in replacement surface and wall mounted LED tube light fittings of capacity 9 watt, basic all purpose decorative ultra slim round profile LED fighting fixture with extruded polycarbonate environmental friendly, energy efficient ready complete all as specified and directed by Engineer-in-Charge. Make : Havells Cat Part No. LHEXBLP7IN1W009 or equivallent in Philips/CG
S&F in replacement surface and wall mounted LED tube light fittings of capacity 18 watt, basic all purpose decorative ultra slim square profile LED fighting fixture with extruded polycarbonate environmental friendly, energy efficient ready complete all as specified and directed by Engineer-in-Charge. Make:Havells Cat Part No. LHEXBTP7IN1W018 or equivallent in Philips/CG
S&F in replacement 15 watt LED bulb. Make : Havells Cat Part No. LHLDDEEEML8R015 or equivalent.
S&F in replacement of Prewired Distribution Board factory made sheet metal enclosure double door distribution board class IP-43 IK 09 with 200 Amps rated copper bus bar 240 Volts, 8 way, SPN DB, suitable for fixing MCB as outgoing and MCCB Triple Pole 100 Amp, rupturing capacity 25 kA as main incoming duly painted including fixing of lugs in main incoming and outgoing line and fixing of cable glands of suitable size including grouting the same in wall by means of nut bolts, angle iron and making good distrurbed surfaces complete all as specified and directed. Make : Standard/Legrand/Indoasian/Siemens/Schneider.
S&F Exhaust Fan 300mm sweep, BEE approved, ISI Marked with mounted in suitable opening arrangement with louvers and shutters suitable for operation on 240 volts, Single Phase, AC supply and connecting upto including three core PVC insulated PVC sheathed copper conductor flexible cable 23/0.0076 from ceiling rose or connector block including marking of MES number complete all as specified and directed. Make : Crompton Greaves/Usha/Bajaj/Orient/Havells.
M&L in repair for earthing complete with galvanized steel earth plate electrode 60cmx60cmx6mm thick burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of plate not less than 1.5 m deep below normal ground level and connected to and including galvanized iron lead earth wire 4mm dia by means of GI nuts, bolts, check nuts, washers thimbles, etc as shown in electrical plate No 3 of SSR Part-I and connection to main switch board/Test point/panel/equipment and testing on completion including excavation and earth work in any type of soil, returning filling in, and removal of surplus spoil to a distance not exc 50 metre, charcoal and salt in alternate layer 15cm thick all around the earth plate electrode, MS funnel with wire mesh, GI pipe medium grade 20 mm bore for watering and 15mm bore 7.50 metre long GI pipe light grade for earth wire protection fixed with poles with two clamps, made from MS flat 25 mmx3mm, bolts, nuts and washers, PCC chamber (1:3:6) type C1, 23 mm thick sand stone slab pit cover complete all as specified & as directed including dismantling & taking out old existing unserviceable earthing. Note : PCC chamber shall be constructed at least 1.5 mtr away from the earth electrode and pipe for watering shall be provided in slanting manner.
Supply, install, testing and commissioning factory made and tested (including CPRI type test certified) LT panel size 800mm x 600mm x 150mm enclosures cubical weather and vermin proof totally enclosed made out of 1.60mm thick CRCA sheet machince pressed of suitable size to operate on 3 phase, 4 wire system, 415 volts, 50 Hz, AC supply system, double door with front openable and PVC arculic glass cover suitable size for checking of meter reading without opening door with locking arrangement including inner shutters for mounting switch grear etc, suitable arragement for fixing of electrical meter and SPN 40-63 Amp including pre wiring from copper bus bars to meter and meter to MCB SPN (for pre wiring use 6 sqmm single core copper cable and suitable size of lugs for connecting from suitable size bus bar to meter and meter to MCB SPN) including bottom gland plate with suffient numbers of circular cable entry holes, including prewired complete as per drawing with masonry work for fixing in wall duly powder coated with comprising of the following:- (a) Copper bus bar suitable capacity - 01 Set (b) MCCB, 4 Pole, 63 Amps rating, rupturing capacity 25 kA, 415 volt grade, AC, 50 Hz, adjustable thermal and fixed magnetic type - 01 No (In coming)
(c) MCB, SP, 32 Amps, rupturing capacity 10 kA, 415 volt grade, AC, 50 Hz - 03 No. (out going) (d) Phase indicating lamp LED type with HRC fuse - 1 set of three (e) On/Off indicating lamp on incomer feeder for status of feeder - 02 Nos (f) Single phase electronic energy meter with LCD display of rating 5-30 Amp class 1.0, 240 Volt, 50 Hz counter type display with transparent hinge including connection from SPN to meter with 6 Sqmm copper stranded conductor including earth wire. Make : HPL Cat Part No SPPC131000000200C00 or equivalent in Neptune - 04 No. Note:- (i) LT panel base frame shall be grouted in PCC (1:2:4) type B-1 using 20mm graded stone aggregate. The base shall be 60cm height from the nearest road level/floor level or as directed. (ii) All incoming MCCB shall be connected through MCB spreaders with incoming bus bar and incoming cable shall be connected with incoming bus bar. Disconnecting, dismantling & taking down old unserviceable LT Panel any capacity with fixtures (iii) Drawing of LT Panel shall be got approved well in advance from Engineer-in-Charge before fabrication of LT Panel. (iv) The quoted rate shall deemed to include supply & provision of 65mm lock with 2 keys. Make of Lock:- Godrej/Harrison/Link. (v) Cost of platform, MCCB spreaders, cable glands, locking arrangement with lock and key and any minor addition/alteration if required at site (the decision of GE will be final and binding regarding extent to which the change can be considered as minor addition/alteration) shall be deemed to be included in the quoted rates.
BHAGWATI CONSTRUCTION
BHIM ENTERPRISES
S.D. And Company
Nitin Enterprises
rajesh builders
MAHAVIR CONSTRUCTION CO
S.G.ENGINEERING COMPANY
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .