Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.2 LAccepted-AOC H N 131 GOPLAPUR NEW SHIVPURI GOPLAPUR GORAKHPUR UTTAR PRADESH 273016 | GORAKHPUR | UTTAR PRADESH | 273016 | L1 | Accepted-AOC Lowest bid | |
| 2 | L2₹10.5 L+₹27,010 (2.64%)Rejected-Finance JHARIA BENIGANJ HARDOI | BENIGANJ | HARDOI | UTTAR PRADESH | L2 | Rejected-Finance Second Lowest | |
| 3 | L3₹10.8 L+₹59,510 (5.81%)Rejected-Finance HNO 365 STREET NO 12 TALAB TILLO JAMMU RISHI TRADING CO TALAB TILLO ROAD OPP FRIENDS LANE JAMMU JAMMU KASHMIR 180002 | JAMMU | JAMMU AND KASHMIR | 180002 | L3 | Rejected-Finance Third Lowest |
Tender Value
Refer Docs
EMD Value
₹11,000
Closing Date
30 May 2020, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Superintending Engineer
ELECTRICITY URBAN DISTRIBUTION CIRCLE, BUNGLOW NO.-9, OLD POWER HOUSE COLONY, RAILWAY STATION ROAD, GORAKHPUR
FOR THE WORK OF AGAINST SANCTIONED PACKAGE NO. 79/2019-20, 82/2019-20, 83/2019-20, 84/2019-20, 172/2019-20 AND 203/2019-20
2020_PVVNV_472512_1
13/EUDC(G)/2020-21
Open Tender
Electrical Works
Lump-sum
60 days
Area of EUDC
Please refer Tender documents.
2 documents required · 2 mandatory
₹3,540
Superintending Engineer, EUDC, Gorakhpur
₹11,000
16 Jun 2020
19 May 2020
1 Jun 2020
19 May 2020
30 May 2020
19 May 2020
180 days
Amount
fo|qr uxjh; forj.k [k.M&izFke] xksj[kiqj ds vUrxZr fctusl Iyku 2019&20 esa Lohd`r iSdst la[;k 79] 82] 83 ,oa 84@2019&20 ds vUrxZr fofHkUu LFkkuksa ij LFkkfir dqy 4 vnn 630 ds0oh0,0 ds ifjorZd dk Hkkj de djus gsrq dqy 4 vnn vfrfjDr 400 ds0oh0 dk ifjorZd yxkus ds dk;ksZ dks lseh VuZdh vk/kkj ij djk;s tkus gsrq dk;Z dk fooj.k%&
Loading, unloading and Carriage of following material from Store Centre, Gorakhpur to work site:-11/0.4 KV 400 KVA Transformer- 04 No., ST Pole 11 Mtr long- 16 Nos., ST Pole 9 Mtr long- 20 Nos., ACSR Dog Conductor- 3.50 Km., LT Cable Al (1x400 Sq.mm.)- 192 mtr., 11 KV Pin Insulator with fitting- 36 Nos., 11 KV Disc Insulator with fitting- 12 Nos., 11 KV Dropper Angle- 08 Nos., 11 KV Top Channel- 04 No., 11 KV T-off - 04 No., Stay complete- 19 Nos., Earthing Complete- 08 Nos., 11 KV XLPE Cable 3X70 Sq.mm- 600 mtr., 11 KV XLPE Cable Jointing Kit- 4 Nos., 11 KV V Type X arms- 14 Nos.
Fabrication & erection of substation Double Pole structure on 11 mtr. Long ST Pole with fixing of necessary clamps & accessories required such as Top Channel, Pin insulator etc including digging of pit 2 mtr. as well as grouting and plinthing of ST Pole (Size of the pole plinth is kept as 450x450 mm x depth and height 300 mm above ground level with top 100 mm is kept tapered so that no rainwater gets accumulated on the top) with 1:4:8 CC ratio of cement, sand & brick ballast, backfilling of pits with mud completely (As per RESPO norms). All required materials such as Holding clamp, Nuts & Bolts off size etc. will be provided by the contractor.
Fabrication & erection of single 11 mtr. Long ST Pole with fixing of necessary clamps & accessories required including digging of pit depth 1/6 of the length of pole as well as grouting and plinthing of ST Pole (Size of the pole plinth is kept as 450x450 mm x depth and height 300 mm above ground level with top 100 mm is kept tapered so that no rainwater gets accumulated on the top) with 1:4:8 CC ratio of cement, sand & brick ballast, backfilling of pits with mud completely (As per RESPO norms). All required materials such as Holding clamp/STP clamp, F-Bracket, Nuts & Bolts off size etc will be provided by the contractor.
Fabrication & erection of single 9 mtr. Long ST Pole with fixing of necessary clamps & accessories required including digging of pit depth 1/6 of the length of pole as well as grouting and plinthing of ST Pole (Size of the pole plinth is kept as 450x450 mm x depth and height 300 mm above ground level with top 100 mm is kept tapered so that no rainwater gets accumulated on the top) with 1:4:8 CC ratio of cement, sand & brick ballast, backfilling of pits with mud completely (As per RESPO norms). All required materials such as LT clamp, Shackle insulator, Nuts & Bolts etc shall be provided by the contractor.
Painting of Pole by double coating Aluminium & Red oxide paint. Paint will be provided by contractor
Earthing of ST Pole by MS earthing Rod & 6 SWG earthing Wire as per RESPO norms.
Erection and grouting of stay in CC ratio 1:4:8 of Cement, Sand and Stone Ballast including cost of grouting material with nozelling and binding of stay wire (Complete work)
Laying, stringing, sagging, binding and jumpering of ACSR Dog conductor of LT/HT Line with providing and fixing of LT Clamps/other clamps, Shackle insulator and nuts&bolts off size by the contractor
Laying, stringing, sagging, binding and jumpering of 11 KV XLPE cable 3x70 Sq.mm. Overhead Line with providing and fixing of Holding Clamps/other clamps, and nuts&bolts off size by the contractor
Errection of Cable Jointing Kit 3X70 Sq.mm.
Construction of T/F plinth of size 2x2x1.2 mtr with the help of first class brick & 9" masonary in the ratio 1:4 cement & sand coarse. Filling the structure completely and plastering outer surface as per RESPO norms. Top of the plinth covered with 4" RCC Slab of ratio 1:1.5:3 (Cement, sand & concrete) grouting with 2 Nos. ISMC size 125X65X6 MM (confirming to IS 808:1989) of 2000 mm long for resting. All required materials will be provided by the contractor.
Grill fencing of 11/0.4 KV S/S shall be made of rectangular of size & height approx 2 meter as per site requirement with fabrication 50X50X5 mm angel the frame is also have 1 no. Horizontal runner of MS flat 40x5 welded in middle to support of grill, having a gate on road side must have provision of locking arrangement. The work is including painting of fencing as per norms. Work will be done as per RESPO specification.
Fabrication, errection, commissioning & Testing of 400 KVA T/F on Double Pole with all accessories including make its LT and HT connection. All neessary materials such as Holding clamp, Copper Z clamp, Al.Lugs (Confirming to IS 8309), Nuts & Bolts will be supplied by the Contractor.
Chemical earthing of Transformer (Body+Neutral) as per IS Code 3043 - 1987 specification
fo|qr uxjh; forj.k [k.M&izFke] xksj[kiqj ds vUrxZr fctusl Iyku 2019&20 esa Lohd`r iSdst la[;k 203@2019&20 ds vUrxZr ykyfMXxh ij LFkkfir 1 vnn 1000 ds0oh0,0 ds ifjorZd dk Hkkj de djus gsrq 1 vnn vfrfjDr 400 ds0oh0 dk ifjorZd yxkus ds dk;ksZ dks lseh VuZdh vk/kkj ij djk;s tkus gsrq dk;Z dk fooj.k%&
Loading, unloading and Carriage of following material from Store Centre, Gorakhpur to work site:-11/0.4 KV 400 KVA Transformer- 01 No., ST Pole 11 Mtr long- 3 Nos., ST Pole 9 Mtr long- 2 Nos., ACSR Dog Conductor- 0.150 Km., LT Cable Al (1x400 Sq.mm.)- 48 mtr., 11 KV Pin Insulator with fitting- 12 Nos., 11 KV Disc Insulator (T&C Type)-45N with fitting- 03 Nos., 11 KV V type Cross Arm- 1 No., 11 KV Dropper Angle- 02 Nos., 11 KV Top Channel- 01 No., 11 KV T-off Channel - 01 No., Stay complete- 02 Nos., Earthing Complete- 05 Nos.,
Fabrication & erection of substation Double Pole structure on 11 mtr. Long ST Pole with fixing of necessary clamps & accessories required such as Top Channel, Pin insulator etc including digging of pit 2 mtr. as well as grouting and plinthing of ST Pole (Size of the pole plinth is kept as 450x450 mm x depth and height 300 mm above ground level with top 100 mm is kept tapered so that no rainwater gets accumulated on the top) with 1:4:8 CC ratio of cement, sand & brick ballast, backfilling of pits with mud completely (As per RESPO norms). All required materials such as Holding clamp, Nuts & Bolts off size etc. will be provided by the contractor.
Fabrication & erection of single 11 mtr. Long ST Pole with fixing of necessary clamps & accessories required including digging of pit depth 1/6 of the length of pole as well as grouting and plinthing of ST Pole (Size of the pole plinth is kept as 450x450 mm x depth and height 300 mm above ground level with top 100 mm is kept tapered so that no rainwater gets accumulated on the top) with 1:4:8 CC ratio of cement, sand & brick ballast, backfilling of pits with mud completely (As per RESPO norms). All required materials such as Holding clamp/STP clamp, F-Bracket, Nuts & Bolts off size etc will be provided by the contractor.
Fabrication & erection of single 9 mtr. Long ST Pole with fixing of necessary clamps & accessories required including digging of pit depth 1/6 of the length of pole as well as grouting and plinthing of ST Pole (Size of the pole plinth is kept as 450x450 mm x depth and height 300 mm above ground level with top 100 mm is kept tapered so that no rainwater gets accumulated on the top) with 1:4:8 CC ratio of cement, sand & brick ballast, backfilling of pits with mud completely (As per RESPO norms). All required materials such as LT clamp, Shackle insulator, Nuts & Bolts etc shall be provided by the contractor.
Laying, stringing, sagging, binding and jumpering of ACSR Dog conductor of LT/HT Line with providing and fixing of LT Clamps/other clamps, Shackle insulator and nuts&bolts off size by the contractor
Painting of Pole by double coating Aluminium & Red oxide paint. Paint will be provided by contractor
Earthing of ST Pole by MS earthing Rod & 6 SWG earthing Wire as per RESPO norms.
Erection and grouting of stay in CC ratio 1:4:8 of Cement, Sand and Stone Ballast including cost of grouting material with nozelling and binding of stay wire (Complete work)
Construction of T/F plinth of size 2x2x1.2 mtr with the help of first class brick & 9" masonary in the ratio 1:4 cement & sand coarse. Filling the structure completely and plastering outer surface as per RESPO norms. Top of the plinth covered with 4" RCC Slab of ratio 1:1.5:3 (Cement, sand & concrete) grouting with 2 Nos. ISMC size 125X65X6 MM (confirming to IS 808:1989) of 2000 mm long for resting. All required materials will be provided by the contractor.
Grill fencing of 11/0.4 KV S/S shall be made of rectangular of size & height approx 2 meter as per site requirement with fabrication 50X50X5 mm angel the frame is also have 1 no. Horizontal runner of MS flat 40x5 welded in middle to support of grill, having a gate on road side must have provision of locking arrangement. The work is including painting of fencing as per norms. Work will be done as per RESPO specification.
Fabrication, errection, commissioning & Testing of 400 KVA T/F on Double Pole with all accessories including make its LT and HT connection. All neessary materials such as Holding clamp, Copper Z clamp, Al.Lugs (Confirming to IS 8309), Nuts & Bolts will be supplied by the Contractor.
Chemical earthing of Transformer (Body+Neutral) as per IS Code 3043 - 1987 specification
fo|qr uxjh; forj.k [k.M&izFke] xksj[kiqj ds vUrxZr fctusl Iyku 2019&20 esa Lohd`r iSdst la[;k 172@2019&20 ds vUrxZr jkuhckx iks"kd dk Hkkj de djus gsrq vfrfjDr Hkkj cq) fogkj iks"kd ij f'k¶V djus ds dk;ksZ dks lseh VuZdh vk/kkj ij djk;s tkus gsrq dk;Z dk fooj.k%&
Loading, unloading and Carriage of following material from Store Centre, Gorakhpur to work site:-ST Pole 11 Mtr long- 11 Nos., ACSR Weasel Conductor- 0.920 Km., 11 KV Pin Insulator with fitting- 24 Nos., 11 KV Disc Insulator with fitting- 24 Nos., 11 KV Dropper Angle- 03 Nos., 11 KV Top Channel- 01 No., 11 KV T-off - 07 No., Stay complete- 5 Nos., 11 KV XLPE Cable 3X120 Sq.mm- 100 mtr., 11 KV XLPE Cable Jointing Kit- 4 Nos., 11 KV V Type X arms- 6 Nos.
Fabrication & erection of substation Double Pole structure on 11 mtr. Long ST Pole with fixing of necessary clamps & accessories required such as Top Channel, Pin insulator etc including digging of pit 2 mtr. as well as grouting and plinthing of ST Pole (Size of the pole plinth is kept as 450x450 mm x depth and height 300 mm above ground level with top 100 mm is kept tapered so that no rainwater gets accumulated on the top) with 1:4:8 CC ratio of cement, sand & brick ballast, backfilling of pits with mud completely (As per RESPO norms). All required materials such as Holding clamp, Nuts & Bolts off size etc. will be provided by the contractor.
Fabrication & erection of single 11 mtr. Long ST Pole with fixing of necessary clamps & accessories required including digging of pit depth 1/6 of the length of pole as well as grouting and plinthing of ST Pole (Size of the pole plinth is kept as 450x450 mm x depth and height 300 mm above ground level with top 100 mm is kept tapered so that no rainwater gets accumulated on the top) with 1:4:8 CC ratio of cement, sand & brick ballast, backfilling of pits with mud completely (As per RESPO norms). All required materials such as Holding clamp/STP clamp, F-Bracket, Nuts & Bolts off size etc will be provided by the contractor.
Laying, stringing, sagging, binding and jumpering of ACSR Weasel conductor of LT/HT Line with providing and fixing of LT Clamps/other clamps, Shackle insulator and nuts&bolts off size by the contractor
Laying, stringing, sagging, binding and jumpering of 11 KV XLPE cable 3x120 Sq.mm. Overhead Line with providing and fixing of Holding Clamps/other clamps, and nuts&bolts off size by the contractor
Errection of Cable Jointing Kit 3X120 Sq.mm.
Painting of Pole by double coating Aluminium & Red oxide paint. Paint will be provided by contractor
Erection and grouting of stay in CC ratio 1:4:8 of Cement, Sand and Stone Ballast including cost of grouting material with nozelling and binding of stay wire (Complete work)
M/s Anil kumar singh
Rishi Trading Co.
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .