Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.0 LAccepted-AOC FLAT NO 601 TOWER NO 30 SECTOR NO 21 AMANORA PARK TOWN HADAPSAR PUNE 411028 | PUNE | MAHARASHTRA | 411028 | L1 | Accepted-AOC AOC | |
| 2 | L2₹38.3 L+₹2.3 L (6.43%)Rejected-Finance B 1 2 MAHESH NAGAR AMBALA CANTT 133001 HRY | AMBALA CANTT | AMBALA | HARYANA | 133001 | L2 | Rejected-Finance High Rate |
Tender Value
₹47.7 L
EMD Value
₹95,300
Closing Date
30 May 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer (Central) Pune
Garrison Engineer (Central) Pune PIN - 411001
SPL REPAIRS TO BLDG NO P-103 (COOK HOUSE DINNING HALL) P-1A , PROVN OF CHEQURED TILE PATH ADJACENT TO CHILDREN PARK PROVN OF CHEQURED TILE PATH ADJACENT TO BLDG NO P-2 (SWIMMING POOL) AT AIPT AND APTC DEPOT UNDER GE (CENTRAL) PUNE
2025_MES_706412_1
8591 SPL REPAIRS TO BLDG NO P-103 (COOK HOUSE DINNING HALL) P-1A , PROVN OF CHEQURED TILE PATH
Open Tender
Civil Works
Item Rate
180 days
Garrison Engineer (Central) Pune
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
Garrison Engineer (Central) Pune
₹95,300
Yes
8 Jul 2025
2 May 2025
2 Jun 2025
2 May 2025
30 May 2025
16 May 2025
Amount
M&L water proofing treatment to RCC roof slab,walls,chajjas etc,shall be carried out as specified below and as directed by Engr-in-charge (a) Removing of existing old bitumenous tarfelt (water proofing treatment) including cement screed bed and clean the surface with wire brush and washing with water to achieve the original surface of slab. (b) M&L for 10mm thick plaster bscreed bed layer in CM 1:3 on concrete surfaces mixed with WPC @ 3% by weight of Cement. (c) Preparing plastered surfaces of roof slab,walls, chajjas etc by brooming with broom sweeping free from dirt dust etc and applying one coat of oil based cold bituminius primer @ 0.40 ltr per Sqm of area complete all as specified . (d) Laying APP polymer modified approved membrane ,non woven,polyster,weighing not less than 3.5Kg /Sqm and 3mm thick with side laps and over laps as specified and joints sealed and applied complete by torch application method all as specified and directed by Engr -in-charge .Carring out test by flooding water for 24 hrs for leekage and seepage and rectifying the same to the entire satisfaction of GE. (e) Finally applying a coat of solar reflective bituminous aluminium paint @ 0.15ltr/Sqm on the top of membrane complete all as specified and directed by Engr-in-Charge.
Demolition of unreinforced cement concrete of any description and in any position on roof slab/sunken slab as in padding etc including removing rubbish off the premises out side MD land complete all as specified and as directed.
M&L for cement concrete (1:2:4) type BO (12.5 mm graded aggregate) as in sunken floor,roof padding and similar items mixed with liquid water proofing compound @ 200ml/Bag of cement complete all as specified and directed. Note: Liquid WPC shall be measured and paid seperately.
Supply only liquid water proofing compound of approved make all as specified.
Taking down chowkats or frames with shutter (without taking off shutter from the frames) n. exc 1.50 Sqm each with and including including making good the disturbed surfaces as original with CM (1:6) or PCC (1:2:4) type B0 complete all as specified and as directed.
Taking down chowkats or frames with shutter (without taking off shutter from the frames) exc 1.50 Sqm but not exc 4 Sqm each with and including making good the disturbed surfaces as original with CM (1:6) or PCC (1:2:4) type B0 complete all as specified and as directed.
S&F pressed steel frames of size 125x60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc. complete all as specified and directed.
S&F pressed steel frames of size 105x60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc. complete all as specified and directed.
M&L for Cement concrete 1:3:6 type C1 (20mm graded stone aggregates) for filling of pressed steel frame and hold fast block cutting etc complete
S&F 35 mm thick flush shutters, solid core construction, with particle board core and plywood face panels, commercial type on both sides, both face is covered with decorative face veneer with lipping/frame to match complete all as specified and directed
Supply and fixing (factory Made) 2nd class hard wood 35 mm thick glazed and skelton shutters open rebated and prepared to receive gauge. (With sash bars ) edges of framing plain chamfered or rounded fitted with cut and mitred beads for securing glass etc both faces to be coverd with decorative face veneers, sizes of members of shutters as specified in SSR Part-I section 8 clause 8.24 (a) supplied and fitted to chowkats complete all as specified.
S&F Factory Made Solid PVC Moulded Door Shutter, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front face & 2mm plain colour PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing complete all as specified and directed.
S&F factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 50 x 100 mm comprising (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant 152 SECTION 8 and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately). ® Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made.
S&F factory made wood grain printed (Prelaminated) solid panel PVC door shutter 30mm thick (Style) consisting of frame made out of MS tubes 19 mm x 19 mm having wall thickness 19 gauge for stiles. MS tube 15mmx 15mm having wall thickness 19 mm gauge for top and bottom rails. MS frame shall be covered with 5mm thick heat moulded prelaminated colour PVC 'C' channel having 5mm thick PVC sheet strip 20mm wide struck inside with solvent cement for stiles and 5mm thick PVC sheet for top rail, lock rail and bottom rail on either side and 10mm (5mm x 2mm) thick, 20mm wide cross PVC sheet as gap insert for top and bottom rail. Paneling of 5mm thick prelaminated colour PVC sheet to be fixed in MS frame welded/sealed to the stiles and rails with 5mm x 30 mm PVC sheet beading and jointed together with solventcement complete all as shown in drg give on page 176 of SSR 2020 part II. The width of stiles and rails shall be as specified in para 8B.2.1 on page 145 of SSR 2020 part II. Each PVC door shutter leaf consist of 3 Nos 100 mm long stainless steel butt hinges. complete all as specified and directed.
S&F Factory made wood grain printed (Prelaminated) solid PVC single door frame of size 50 x 47 mm with a wall thickness of 5mm prelaminated colour sheet reinforced with 19 mm x 19mm MS square tube having wall thickness 19 guge complete all as shown in sketch on page 150 of SSR 2020 Part II complete all as specified and directed.
S&F aluminium powder coated frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc complete all as specified and directed
S&F anodised powder coated aluminium door shutters (single / double leaf) or partitions, aluminium section weighing 0.55kg/m including necessary joining cleats, al powder coated glazing clips, rubber neoprene packing, Al powder coated handles 2 Nos in each door, Al powder coated tower bolt 02 Nos, powder coated MS butt hinges 03 Nos, Al powder coated snap beading, screws, door stopper 01 No etc. complete all as specified. Note :- Glass pane and particle board shall be measured and paid seprately.
S&F anodised powder coated window and ventilator shutters in three track sliding (whichever the case may be ordered to sliding horizontally or vertically) with two or more shutters with sliding arrangement with two or more shutter rubber beading and glazing clips using aluminium sections weighing not less than 0.55 Kg/M , aluminium handle / handle slot, locking arrangement etc complete all as specified and directed. Note:- Wiremesh and glass pane shall be measured and paid sepratly.
S&F anodised powder coated ventiator with louvers with partially guaged shutter using 5 mm thick x 10 cm wide frosted glass strips with rubber beading and glazing clips etc using aluminium sections weighing not less than 0.55 Kg/M complete all as specified and as directed
S&F Steel windows with side hung shutters including projecting type hinges with steel handle, tower bolts and steel peg stay, complete with glazing bars, dovetailed or welded, complete all as specified and as directed
Supply only 4.0mm sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane, complete all as specified and as directed
Supply only 9 mm thick prelaminated particle board interior gde prelaminated both side with decorative choice and other side white lamination fixed with screws as in aluminium partation & aluminium door shutter etc all as directed.
Supply only stainless steel wire 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed to aluminium window / ventilator shutters / steel windows etc complete all as specified and directed
Supply only Anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved nodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in-charge.
S&F stainless steel butt hinges 100mm, complete all as specified and directed.
S&F 150 mm extruded aluminium alloy handles ,fabricated type complete all as specified and directed.
S & F Aluminium anodised powder coated barrel tower bolt of extruded section 150mm long all as specified and directed .
S&F in repairs brass handles, cast type, polished bright 150 mm long complete all as specified and directed.
S&F in repair 300 mm size Brass barrel tower bolts, with cast or sheet barrel and rolled or cast bolts and fixed complete all as specified and directed.
S&F in repair 150mm long aluminium anodized floor door stopper double legged with rubber shoe, fixed to bottom rail of door complete all as specified and directed.
S&F in repairs 300 mm long Brass, sliding door bolt with sand or die-cast brass hasp, staple (bolt type) and fixing bolt with rolled or drawn brass bolts and fixed complete all as specified and directed.
S&F in repair Door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed Aluminium (extruded section body) complete all as specified and directed
S&F 250 mm long aluminium alloy anodised sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts & sliding bolts of extruded sections or cast aluminium alloy complete all as specified and directed.
Hacking out old broken glass (any thickness, size quality or description) from metal frame including punching or drilling out old glazing pins/spring clips and providing and fixing new ones, complete all as specified and as directed
S & F sheet glass 3mm thick ordinary quality and glazing with oil putty in squares n exc 0.50 Sqm in each pane. complete all as specified and as directed
Supply and fix in repairs stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed to steel windows/steel ventilator including necessary screw and bolts etc complete all as specified and directed.
Resecuring or easing and adjusting of steel window/steel ventilator without taking down for easy opening and closing all as per direction of Engr-in-Charge.
S&F in repairs drapery rod, 25mm dia, stainless steel with and including fency type stainless bracket / wall to wall/side bracket 02 Nos at each opening and stainless steel side stopper fency type of required shape and size complete all as specified and directed.
Demolition of brick work / Stone masonary / PCC block masonary built in cement morter of any description and removing of rubbish from the MOD land, complete all as specified and as directed
M&L for precast concrete solid block masonry exc 10cm width with solid block of PCC (1:5:8) Gde D-5 and setting in CM 1:6 complete all as specified and directed.
M&L for brick work with old size subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius, built in CM 1:6 complete all as specified and directed.
Surface excavation n.exc. 30 cm deep and averaging 15cm deep and getting out in soft / loose soil, complete all as specified and as directed
Removal excavated soil n.exc 50m and depositing where directed at a level n.exc 1.5 m above the starting point complete all as specified and as directed
M&L for hard core of broken stone of gauge exe 63 mm deposited spread and leveled in layers not exe 15cm thick watered and rammed to a true surface, complete all as specified and as directed
M&L for preparation newly plastered surfaces of wall and applying three coats of white wash complete all as specified.
Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish from the MOD land complete all as specified and directed.
Demolition of Cement Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) un-reinforced cleaning the premises and removal of rubbish out side the MD land at the location notified complete all as specified and directed.
M&L for 75mm thick PCC (1:3:6) Type-C2 (using 40mm graded crushed stone aggregate) as in plinth protection / path finishing cement concrete surface even and smooth without using extra cement complete all as specified and directed.
M&L for plain cement concrete (1:4:8) Type-D2 (using 40mm graded crushed stone aggregate) as in levelling course / sub base of flooring complete all as specified and directed.
M & L Non - skid ceramic coloured tiles,size 300x300x 7 mm thick laid on floor , over and including 15mm thick screed bed in cement mortar 1:6 and pointed in white cement with pigment to match the shade of the tiles, complete all as specified and as directed.
M&L machine cut kota stone slab flooring 20- 25mm thick over and including 20mm screed bed in CM(1:4)cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.
M&L machine cut kota stone(one piece) 20-25mm thick in riser/trade of steps, skirting, dado and pillar laid over 20mm screed bed CM(1:4)cement screed bed laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete
Mirror polishing on marble/ granite/ Kota stone/ stone work where ever required to give high gloss finish complete all as specified and directed.
M&L for rubber moulded glossy chequered cement concrete coloured tiles 30cm x 30cm x 20mm thick, set, jointed and pointed in neat cement slurry in floors over and including 20mm thick screed bed in cement mortar 1:6 complete all as specified and directed.
M&L for providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc. of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand;
M&L for coloured glazed ceramic tiles in vertical surface 300X 450X 7 mm/300x600x7mm/450x600x7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match over and including 10mm thick backing coat in CM 1:4 complete all as specified.
Taking down cement or cement lime plaster, any description, on brick or stone walls, etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
M&L rendering 10 mm thick in CM 1:6 on fair face of brick /concrete / stone surfaces of any description and finishing the surfaces even and smooth with a thin layer of sogal finish complete with complete all as specified and directed.
M&L rendering 15 mm thick in CM 1:4 in on brick/concrete wall surfaces of any description, and finishing the surfaces even and smooth complete all as specified and directed.
M&L for 10mm thick rendering in CM 1:3 on concrete surface as in ceiling finished even and smooth complete all as specified and directed .
M& L dubbing out average 10mm thick on irregular face of walls complete all as specified and as directed.
M&L for preparing new plastered surfaces of walls and applying two coats of oil bound distemper over a thin layer of wall care putty complete all as specified and directed.
M&L for preparing new plastered surface of walls and applying two coats of cement based paint over a coat of cement primer of same make complete all as specified and directed.
M&L for preparing new plastered or unplastered surfaces of ceiling and applying two coat of oil bound distemper a over a thin layer of wall care putty complete all as specified and directed.
M&L for preparing old plastered or unplastered surfaces of walls and applying two coats of oil bound distemper over a thin layer of wall care putty including complete removal of existing treatment of any layer on wall complete all as specified and directed.
M&L for preparing old plastered or unplastered surface of walls and applying two coat of cement based paint complete all as specified and directed.
M&L for preparing old plastered or unplastered surfaces of ceiling and applying two coat of oil bound distemper over a thin layer of wall care putty complete all as specified and directed.
M&L for preparation of old wooden surfaces and applying two coats of synthetic enamel paint over a coat of pink primer all as specified.
Complete removal of old decorated surface of wall including brooming down and cleaning the surface and applying two coat of cement base paint of approved tint all as specified and directed.
Complete removal of old decorated surface of walls including brooming down and cleaning the surfaces and applying two coat of distemper (Oil emulsion) over a coat 1mm putty of approved tint all as specified and directed.
M&L preparation of new or previously untreated wooden surface of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
Taking up or down 15mm bore steel / composite / UPVC tubing and connection from any position concealed / exposed including cleaning for refixing or removal to store complete all as specified and directed.
Taking up or down 20mm bore steel / composite / UPVC tubing and connection from any position concealed / exposed including cleaning for refixing or removal to store complete all as specified and directed.
S&F 15 mm dia GI tube medium grade with all fittings / connections & MS clamps / clips and necessary screwing as reqd and fixed with or without concealed to walls & surface of roof slab with and including making good to required surfaces by using white/grey cement complete all as specified and directed.
S&F 20 mm dia GI tube medium grade with all fittings / connections & MS clamps / clips and necessary screwing as reqd and fixed with or without concealed to walls, ceilings or laid in floors complete all as specified and directed.
Dismantling water tank of capacity exceeding 250 liters but not excedding 500 Ltrs complete all as specified and directed.
S&F rotational moulded polythene water storage tank 500 ltrs (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-I complete all as specified and directed.
S&F in repair vitreous china pedestal pattern water closet white with including cast iron 'P' or 'S' trap, matching sheet cover with drainage pipe and connection to trap seat cover and . including making good to floor, complete all as specified. Make Jaquar cat part no: CNS-WHT-551 or equivalent model in KOHLER and ROCA.
S&F in repair vitreous China, squatting pan, Orissa Pattern, size 580 x 440 mm white, with integral foot rests (excluding flushing cistern and flush pipe) with PTMT trap of suitable size ( P or S type) including connection to trap and to flushing pipe, anti syphonic pipe etc complete including provision of cement concrete bedding & making good to floor complete all as specified and directed including taking out old one.
S&F in repairs 10 Ltr capacity PVC valveless syphonic action type flushing cistern low level white, with inlet, ball valve, float and handle including PVC flush pipe and brackets complete fixed in wall and floor to trap of WC as reqd complete all as specified and directed.
S&F in repair Vitreous China urinals, half stall (back or corner wall type), complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing flush pipe, grating and Union for discharge pipe including urinal spreader, bottle trap/waste pipe. Make Jaquar cat part no:URS-WHT-13253N or equivalent model in KOHLER and ROCA.
S&F in repair chromium plated fancy type 15mm bore auto closing concealed urinal flush valve with wall flange.Make Jaquar cat part no:PRS-CHR-073 or equivalent model in KOHLER and ROCA.
S&F in repair 15mm bore chromium plated bib cock fancy type with wall flange. Make Jaquar cat part no:FLR-CHR-5047N or equivalent model in KOHLER and ROCA.
S&F in repair 15mm bore chromium plated angle cock fancy type with wall flange.Make Jaquar cat part no:FLR-CHR-5053N or equivalent model in KOHLER and ROCA.
S&F in repair 15mm bore chromium plated concealed cock fancy type body with exposed part kit with operating lever .Make Jaquar cat part no:ALD-CHR-083FT & CON-CHR-069FTK or equivalent model in KOHLER and ROCA.
S&F in repair Brass CP wall mixer for mixing hot & cold water with provision for both hand shower and overhead shower complete with 115mm long bend pipe, connecting legs & wall flange and fixed.Make Jaquar cat part no:FLR-5281N or equivalent model in KOHLER and ROCA.
S&F in repair brass chromium plated overhead shower 100mm round shape single flow with rubit cleaining system fitted to steel pipe or union complete.Make Jaquar cat part no:OHS-CHR-1989 or equivalent model in KOHLER and ROCA.
S&F 15 mm dia PVC connections, 450 mm long with PTMT nuts of suitable size at two end complete all as specified and directed.
S&F in repair 15mm bore chromium plated pillar cock fancy type.Make Jaquar cat part no:FLR-CHR-5015 or equivalent model in KOHLER and ROCA.
S&F in repair health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.00 metre long flexible tube and wall hook including making connections and fixed in position complete all as specified. Make Jaquar cat part no:ALD-CHR-577 or Techno commercial equivalent model in KOHLER and ROCA.
S&F in repairs vitreous china under counter wash hand basin, white, flat back of size 560mm x 370 mm with & including 32 mm dia PVC waste pipe and 32mm bore PTMT waste fitting with long screwed shanks and fly nuts, flange end bedded in red lead cement & other end fixed, (excluding tap, waste chain & plug), complete all as specified. Make Jaquar cat part no:FLS-WHT-5701 or Techno commercial equivalent model in KOHLER and ROCA.
S&F in repair for Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long.Make Jaquar cat part no:CAN-1171 N or Techno commercial equivalent model in KOHLER and ROCA.
Supply and fixed in repair 20mm bore PVC brass valve, high pressure with polythene float and fly nut complete screwed for iron pipe or brass ferrule complete all as directed
Supply and fixed in repair 20mm dia gun metal, globe or gate valves with iron wheel head, screwed both ends for iron pipe and fixed complete
Supply and fixed in repair sinks made of stainless steel 1 mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing antilever brackets and connecting union to pipe, overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm complete all as specified.
Supply and fixed in repair sinks with drainage board made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm complete all as specified.
S&F in repairs chromium plated soap dish approximate size 120x 120x28mm complete all as specified and directed.Make Jaquar cat part no:AKP-CHR-35731P or Techno commercial equivalent model in KOHLER and ROCA.
S&F in repair stainless steel tubular towel rail, 20mm dia, D type, 60cm longv between flanges Make Jaquar cat part no:AKP-CHR-35711PS or Techno commercial equivalent model in KOHLER and ROCA.
Dismantling cast iron work of any de scription and in any position
S& F 110mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified.
.ditto- as aboe but 75mm bore complete all as specified.
S& F 110mm PVC (SWR) branch piece, double (double Y) equal or unequal complete all as specified.
.ditto- as above but 75mm bore complete all as specified.
S&F 110mm PVC (SWR) bands complete all as specified.
S&F 75mm PVC (SWR)bands complete all as specified.
S&F PVC(SWR) Nahani trap 100mm bore with SS grating with or without holes incl jointing to waste pipe fixed in cement concrete type B1 (1:2:4) complete all as directed.
S&F PVC (SWR) cowl 75/100mmdia as required complete all as specified.
S&F 110mm bore PVC (SWR) junction double,(double T).equal or unequal with access door complete all as specified.
M&L 18-20mm thick granite (of any type) work table rubbed and pre polished) in cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixtures of pigment to match with shade of granite complete and ensure best adhesion to surface complete
M&L for machine cut cudappah stone slab 20-25mm thick for vertical supports of kitchen platforms and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing of the exposed face complete all as directed and specified
Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations
Demolition of reinforded cement concrete of any description and in any position for lintel, chajjas, roof projection & manhole covers etc complete
Demolition/Breaking up Drain Pipes (SGSW), AC/RCC 150 mm to 200 mm dia, Jointed in Cement Mortar of any description including demolition of PCC of the Pipes with Bed, complete all as specified and directed by Engineer-in-Charge.
M&L for reinforced cement concrete pipe 150 mm dia class NP2 with one side collar laid and jointed complete with collars as in sewar lines and jointed complete all as specified and as directed .
M&L for Cement Concrete (1:3:6) Type C1 (20mm Graded Stone Aggregate) Bed for Drain Pipes of Bore 150 mm including Packing under and Haunching against the Sides of Pipes after they are laid in Foul Condition and Testing, complete all as specified and as directed.
M&L for PCC 1:2:4 type B1 (using 20mm graded stone aggregate) as in coping, benching, bed block for rungs, window cills etc complete all as specified and directed by Engr-in-charge
M&L for TMT bar 8mm dia and over cut to length bent to shape reqd incl cranking bending etc complete & binding with MS wire (annealed) not less than 0.9mm dia in reinforcement (@ 150MM c/c both ways) complete
M&L for cement concrete type B1 1:2:4 (using 20mm graded stone aggregates) in precast cover slabs for manholes cover and similar articles with plain faces etc set in cement mortar 1:4 including use and waste of formwork complete all as specified.
S&F in 18/19 mm thick prelaminated Medium density fibre board, exterior grade, fixed to timber framework with screws prelaminated one side with decorative choice and other side white lamination fixed with screws as in cup board shutters & shelves and pelmet boxes etc all as directed. Make : Duro/National/Archid Ply wood.
S&F 100 mm long,designer pattern ss handles for fixing in cupboards all as directed and as specified by Engr-in Charge
S&F ,Ball catches with 8mm dia steel ball, and brass body and striking plate including letting in and fixed, complete all as specified and as directed
S&F telescopic drawer channel 19" long complete all as specified and directed by Engr in charge
S&F contineous (piano) hinges, mild steel bright finish of 40 mm width of flaps(when open) complete all as specified.
S&F Locks, drawer, grade I, size 50 mm, complete all as specified and as directed
Dismantling of single layer manglore pattern tiles and ridge in roofing /AC sheet/CGI Sheet roofing complete all as specified and directed.
Dismantling of battens for tiles, shingles etc, of any size and description spaced exc 15cm including tilting fillets complete all as specified and as directed.
S & F 2nd class hardwood Battens for tiles, shingles etc sectional area n exc 15sqcm of size including tilting fillets clean dawn all as specified and directed .
Fixing only batten obtained from dismantling vide item no 3 here -in- before complete all as specified and as directed.
M&L for second clas soft wood, clean sawn in scantling over 40 sqcm and over in section and including Dismantling timber scantling 40 sqcm and over in section, unframed work, in any position complete all as specified and directed by Engr-in-charge.
M & L Roof tiles, Mangalore pattern, interlocking at side joints, laid dry complete all as specified and directed.
Ditto all as above but except tiles complete all as specified and as directed
M & L for Ridge or hip tiles to suit Mangalore pattern of roofing tiles, bedded and jointed in cement mortar 1:6 all as specified and directed.
S&F 0.63 mm thick galvanised, corrugated mild steel sheeting(CGI Sheet) with two corrugations side lap, fixed with L type or J Type or cranked hook bolts and washers, in roofs, walls etc with grade of zine coating 275 etc incl dismantling existing roof sheet complete all as specified and directed.
S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa with AZ 150 as in roof covering/cladding to wall, bent to shape as required and directed fixed with self tapping screws incl dismantling existing roof sheet complete all as specified and directed.
S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa with AZ 150 as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed,Including dismantaling of old AC/galvanised Sheet complete all as specified and directed.
M&L for MS structural steel work, framed as in trusses purlins, rafter, post etc conforming to grade E-250 (Fe-410W, quality A) including shaped washers including necessary cutting required length, notching drilling, riveting and or welding or connecting with nut bolts with angle cleats, fish plat, gusset plate and also erecting in true position complete all as specified and as directed,
M&L preparation of new or previously untreated steel surface of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
M&L preparation of newly plastered surface of wall and applying three coats of white wash complete all as specified and directed.
Dismantling Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets
M&L for 8 mm thick one side laminated gypsum ceiling board for false ceiling of size 600 x600x mm on GI powder coated grid work 60 cm x 60 cm with using 36.5 mm x 23.5 mm x1.5 mm thick main tee, 23.5 x 23.5 mm x 1.28 cross tee and 25 x 25x 1.5 mm angles fixed to perimeter of wall for false ceiling including necessary supporting hanger with 2-3 mm dia GI wire and 'J' bolts washer nuts for securing frame work to ceiling suspended @ 120 cm C/C both ways, size of grid shall be 605 x 605 mm, complete all as directed and specified
Taking down of existing Ceilling fan of any size and sweep and keeping safe custody and refixing the same existing place with serviceable condition by minor repairs such as capacitor replacement, bearing repalcement and painting, clamping of fan rod to roof iron channel, required down rod, complete as per site requirement complete all as specified and as directed. Note : The quoted rate shall include the rates of spares as required.
Taking down of existing Ceilling fan of any size and sweep and keeping safe custody and refixing the same existing place with serviceable condition by minor repairs such as capacitor replacement, bearing repalcement and painting, clamping of fan rod to roof iron channel, required down rod upto , rewiring of fans complete as per site requirement complete all as specified and as directed. Note : The quoted rate shall include the rates of spares and rewiring of fan as required.
M&L for concealed point wiring of any length using approved colour coding as per IS with stranded copper conductor 1.5 Sq.mm (Nominal area), single core, PVC insulated and unsheathed stranded FRLS H cable 1100 volts grade, ISI - 694 marked in PVC conduit of suitable size ISI marked including all accessories etc. with PVC modular boxes/PVC Sunken Boxes as required at site and as directed including modular frame/cover plate suitable for mounting switches/sockets etc. and PVC insulated stranded copper conductor 1.5 Sq.mm single core cable as earth and connecting to common earth dolly complete all as specified and directed for the following:- Note:- The quoted rate shall include (i) necessary required length of circuit wiring of 1.5 sqmm 3 run FRLSH copper cable from DB to switch box (ii) taking down of copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc Making good of disturbed surfaces will be done by contractor without any extra claims. (iii) Cutting chasing of wall if any and making good to the disturbed surfaces with plaster complete
(a) One light point controlled by one switch complete all as specified and directed.
(b) One fan/exhaust point controlled by one 5 Amps one way modular switch and modular regulator complete all as specified and directed.
(d) One 5/6 Amp socket controlled by one switch same board complete all as specified.
(e) One 3 pin 5 Amps Socket outlet point controlled by one switch on independent board complete all as specified
All as per item no 145 above but with 2.5 Sq.mm(Nominal area), single core, PVC insulated and unsheathed multistranded FRLS H cable 1100 volts grade, ISI - 694 marked, including PVC insulated multistranded copper conductor 2.5 Sqmm single core cable for earth continuity conductor for one 3 pin 5/15 Amps switch socket / Earth plug socket independent and connecting to common earth dolly complete all as specified.
M&L for point wiring of any length using approved colour coding as per IS with stranded copper conductor 1.5 Sq.mm (Nominal area), single core, PVC insulated and unsheathed stranded FRLS H cable 1100 volts grade, ISI - 694 marked in PVC casing caping 25mm wide ISI marked including all accessories etc. with PVC modular boxes/PVC Sunken Boxes as required at site and as directed including modular frame/cover plate suitable for mounting switches/sockets etc. and PVC insulated stranded copper conductor 1.5 Sq.mm single core cable as earth and connecting to common earth dolly complete all as specified and directed for the following:- Note:- The quoted rate shall include necessary required length of circuit wiring and taking down of copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc Making good of disturbed surfaces will be done by contractor without any extra claims.
(a) One light point controlled by one switch complete all as specified and directed.
(b) One fan/exhaust point controlled by one 5 Amps one way modular switch and modular regulator complete all as specified and directed.
(c) One 5/6 Amp socket controlled by one switch same board complete all as specified.
(d) One 3 pin 5 Amps Socket outlet point controlled by one switch on independent board complete all as specified
(e) One light point controlled by 2 way switch
(f) One bell point controlled by one way switch
All as per item no. 146 above but with 2.5 Sq.mm(Nominal area), single core, PVC insulated and unsheathed multistranded FRLS H cable 1100 volts grade, ISI - 694 marked, including PVC insulated multistranded copper conductor 2.5 Sqmm single core cable for earth continuity conductor for one 3 pin 5/15 Amps switch socket / Earth plug socket independent and connecting to common earth dolly complete all as specified.
S&F modular switch single pole one way 5/6 Amps including connection complete all as specified and as directed
S&F bell push modular 6A switch complete all as specified and directed.
S&F ding dong bell Ac 230V complete all as specifeid and directed
S&F modular switch single pole two way 5/6 Amps including connection complete all as specified and as directed
S&F socket out let 5/ 6 Amps 3 pin modular type incl connection complete all as specified and as directed
S&F of modular rotating step type electronic fan regulator( 5 step), 100W /240 volts two module incl connection complete all as specified and as directed
S&F of modular socket twin type, 5 pin 6/16 Amps flush type incl connection complete all as specified and as directed
S&F modular switch type single pole one way 15/16 amps incl connection complete all as specified and as directed
S&F in repair ceiling rose, surface, three terminals incl connection complete all as specified and as directed.
Supply and fixing in repairs round shape 15 watt 220 volts AC recessed /surface type CW with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified
Supply and fix wall mounted table light spring type 3 W black/gold/siver complete all as specified and directed
Supply and fix in repairs LED building security light 30 W IP 65 pressure die cast aluminium housing with GI bracket of suitable size complete including clamps , screws etc and dia complete all as specified and directed
Supply and fix aluminium batten tube light 20W including necessary connections with flexible wire 3 core from ceiling rose light terminal complete all as specified and directed
Supply and fix tube light 10W 2 feet including necessary connections with flexible wire 3 core from ceiling rose light terminal complete all as specifie dand directed
Supply and fix decorative design mirror light for 10W gold colour coated complete all as specified and directed
S&F in replacement concelaed Sub main wiring with 2 runs of single core, 6 Sqmm PVC insulated, unsheathed, 1100 volts grade multi-stranded, copper conductor cables (FRLS quality) drawn through PVC conduit of 25 mm with fitting/accessories, fixed on roof, walls, ceiling etc including 6 Sqmm PVC insulated, unsheathed, single core, multistranded, copper conductor as earth continuity wire complete as specified and directed. Note : Rate includes (i) PVC conduit and its accessories (ii) Two runs of cable and one run of earth wire of size 6 sqmm and including taking down of old U/S submain (iii) Cutting chasing of wall and making good to the disturbed surfaces
S&F Sub main wiring with 2 runs of single core, 6 Sqmm PVC insulated, unsheathed, 1100 volts grade multi-stranded, copper conductor cables (FRLS quality) drawn through PVC casing capping with fitting/accessories, fixed on roof, walls, ceiling etc including 6 Sqmm PVC insulated, unsheathed, single core, multistranded, copper conductor as earth continuity wire complete as specified and directed. Note : Rate includes (i) PVC casing capping and its accessories (ii) Two runs of cable and one run of earth wire of size 6 sqmm and including taking down of old U/S submain
S&F Sub main wiring with 2 runs of single core, 1.5 Sqmm PVC insulated, unsheathed, 1100 volts grade multi-stranded, copper conductor cables (FRLS quality) drawn through PVC conduit with fitting/accessories, fixed on roof, walls, ceiling etc including 1.5 Sqmm PVC insulated, unsheathed, single core, multistranded, copper conductor as earth continuity wire complete as specified and directed. Note : Rate includes (i) PVC conduit and its accessories (ii) Two runs of cable and one run of earth wire of size 1.5 sqmm and including taking down of old U/S submain
S&F in repair of MCB SPN DB 8 way IP-43 powder painted with bus bar 100A, neutral link, earth bar and Din rail ,230 Volts with double door including taking down old unsv DB and making the the surface good to match with adjucent complete all as specified and as directed
S&F 4Way VTPN DB double door of bus bar 200 A complete all with MCCB 100A adjustable thermal type as specified and directed
S&F 4Way TPN DB double door of bus bar 200 A complete all as specified and directed
M & L for earthing with galvanised steel earth plate electrode 60 cm x 60 cm x 6.0 mm buried directly in ground earth pit not less than 2.25 m deep below normal ground level, with top edge of the plate vertically to depth of not less than 1.5 m below ground level connected to and incl galvanised iron wire 4mm as earthing lead and GI pipe 15 mm dia light grade for protection to the extent of 7.5 m as earthing lead by means of GI bolts and nuts etc connecting to equipment with provn of charcoal and salt etc all as per electrical plate No 3 of SSR Pt-I incl RCC cover , watering arrangement with GI pipe 20 mm dia and MS funnel, concrete pit with cover incl excavation and earth work in any type of soil and testing on completion etc complete.
Supply and fixing amp rating 240V, 10KA C curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning.
(a) SP 32 AMP
(b) SPN 40-63 AMP
Supply and fixing 415V FP 63A 10KA 'C' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the DB complete with connection testing and commissioning.
Supply, laying and testing cable XLPE Insulated , galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sq mm 3.5 core
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 sq mm 3.5 core
Excavation in trenches, not exc 1.5 mtr wide and not exc 1.5 mtr in depth for laying of LT UG cable/poles etc in soft/loose soil and getting out complete all as specified.
Returning, filling in soil, including spreading, leveling watering and well ramming in layers not exceeding 25cm all as specified and directed.
Removing excavated material not exceeding 50m and depositing where directed at a level not exceeding 1.5 m above the starting point for any type of excavation.
M & L for Cutting of road/hard standing and making good with PCC (1:2:4) using 20mm graded stone aggregate complete all as specified.
M&L DWC pipe 50 mm dia to be lay in trench by passing cable complete all as specified and directed
ANIL CONSTRUCTION CO. (BID ID -3303453)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .