Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.2 LAccepted-AOC | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹33.5 L+₹70,911.97 (2.16%)Rejected-Finance | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹35.0 L+₹2.2 L (6.77%)Rejected-Finance | L3 | Rejected-Finance Other than lowest bidder | |
| 4 | L4₹36.0 L+₹3.2 L (9.76%)Rejected-Finance | L4 | Rejected-Finance Other than lowest bidder | |
| 5 | L5₹36.0 L+₹3.3 L (10.0%)Rejected-Finance 0 | L5 | Rejected-Finance Other than lowest bidder |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
29 Jun 2021, 6:00 pmClosed
GE AF Bamrauli
GE AF Bamrauli
SPECIAL REPAIR FOR REPLACEMENT OF LT PANEL PROVN OF WATCH TOWER ADDITION/ALTERATION AND RENOVATION OF SNCOs BAR ROOM AND OTHER SANCTION WORKS AT AF STN BAMRAULI
2021_MES_448181_1
8647/E8
Open Tender
Civil Works
Item Rate
180 days
GE AF Bamrauli
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
Yes
GE AF Bamrauli
₹60,000
Yes
8 Jul 2021
3 Jun 2021
30 Jun 2021
3 Jun 2021
29 Jun 2021
24 Jun 2021
Amount
Surface excavation not exceeding 30 cm deep and averaging 15cm deep and getting out in soft/loose soil complete all as specified and directed.
Demolition of PQC/ cement concrete of depth not excedding 1.0 mtr with manual / mechanical concrete breaker and removing the debris out side MOD land complete all as specified and directed
Excavation over areas not exceeding 1.5m deep and getting out in soft/ loose soil all as specified and directed.
Removing excavated/ demolished material exceeding 1.50km but not exceeding 5km and depositing where directed at a level not exceeding 1.5m above the starting point including demolished material complete all as specified and directed.
M&L for Machine pressed precast concrete interlocking coloured paver blocks of any shape and size confirming to IS 15658-2006 of 60 mm thick and grade of concrete shall be M-35 laid over and including 25mm thick sand cushioning including filling complete all as specified and directed. Note : Paver blocks shall be tested in NABL approved laboratory for grade of concrete and test certificate shall be produced by the contractor before incorporation in the work.
Supply and laying 150 mm bore reinforced concrete pipes, class NP3, laid and jointed complete with collars complete all as specified and directed.
M&L for concrete bed to drain pipes of 150 mm bore including forming cradles in PCC 1:4:8, type D2 (Using 40 mm graded stone aggregate) complete all as specified and directed.
Excavation in trenches n. exc.1.5m wide and n. exc. 1.5m in depth for foundation etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n. exc. 10 Sq.m. on plan and n. exc. 1.5m in depth and getting out in any type of soil complete all as specified and as directed by the Engineer-in-Charge.
M&L for Soakage well of size 3.6mx6.0 mtr effective depth including excavation in any type of soil , foundation in PCC 1:3:6, type C2 (Using 40 mm graded stone aggregate), walls of honey combed masonry with top ring of M 25 concrete, including intercepting chamber and screen chamber made of brick masonry in cement mortar 1:6 , RCC cover slab in M25/ SFRC cover, inter connecting pipes of RCC/DWC complete filled with brick bats as per CELZ/TD-576 sheet 1/2 dated 16 Jun 69 and CELZ/TD-576 sheet 2/2 dated 16 Jun 69 complete all as specified and directed.
M&L for preparing new or previously untreated steel surfaces of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
M&L brick work with sub class 'B' bricks, straight or curved on plan exceeding 6M mean radius, built in cement mortar 1:6 complete all as specified and directed.
M&L brick work with sub class 'B' bricks, straight or curved on plan exceeding 6M mean radius, built in cement mortar 1:4 (half brick wall) complete all as specified and directed.
M&L for RCC M-25 (Design Mix) as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete etc complete all as specified and directed.
M&L for RCC M-25 (Design Mix) as in Beams, cantilevers, bressumers, lintels over 1.5m span etc complete all as specified and directed.
M&L for RCC M-25 (Design Mix) as in chajja etc complete all as specified and directed.
Use and waste of formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specified and directed.
Use and waste of form work to sides and soffits of floor or roof beams, beam haunchings, girders, lintels, cantilevers, shelves including supports overhangs, etc of plinth/roof beam and similar works vertical or better for fair finished surfaces of concrete etc complete all as specified and directed.
Use and waste of form work to soffits of suspended slab such as roof slaves, floors slaves, landing and similar works, n.exc 200mm thick (horizontal or slopping) for fair finished surfaces of concrete etc. complete all as specified and directed.
M & L for Mild steel TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
M&L Mild steel TMT bars of 6mm to 8mm dia, cut to length, bent to shape required including cranking, bending, spirally for hooping, hooking ends and binding with annealed mild steel wire not less than 0.9mm dia or securing with clips or welded complete all as specified and as directed.
M&L for hard-core broken stone of gauge n.exc 63mm deposited, spread, levelled in layers n.exc 15mm thick, watered and rammed to surface complete all as specified and directed.
M & L for 75 mm thick PCC 1:3:6 type C2 (40mm graded aggregate) for plinth protection finishing cement concrete surface even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 15mm thick in cement mortar 1:4 on fair faces or brick work or concrete surfaces, finished even and smooth without using extra cement and mixed with water proofing compound @ 3% by weight of cement complete all as specified and directed. Note: Water proofing compound will be measured and paid separately.
M&L for rendering 15mm thick in cement mortar 1:6 on fair faces of brick work or concrete surfaces and finished even and smooth (Without using extra cement) complete all as specified and directed.
M&L for 5 mm thick rendering in in cement mortar 1:3 on concrete ceiling surfaces finished even and smooth without using extra cement etc complete all as specified and directed.
Supply only Integral waterproofing compound of approved make.
M&L for Preparing newly plastered surfaces walls and applying three coats of white wash etc complete all as specified and directed.
M&L for Preparation of new plastered surfaces of walls and applying two coats of cement base paint over a coat of cement base primer complete all as specified and directed.
M&L preparing newly plastered surfaces of ceiling surfaces and applying three coats of white wash etc complete all as specified and directed.
M&L for 25mm thick cement concrete 1:2:4 type B-0 (12.5mm graded aggregate) as in levelling course etc complete all as specified and directed.
S&F Non Skid coloured ceramic tiles (Premium quality) 300mmx 300mm x 7 to 8 mm thick(Square/ rectangular) as in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile over and including 15mm thick screed bed layer in cement mortar 1:6 etc complete all as specified and directed.
M&L for Glazed coloured ceramic tiles (Premium quality) in vertical surface 350 x250x 7 mm/ 450x 350x7 mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile over including 10mm thick rendering in CM (1:4) complete all as specified and directed.
S&F Solid PVC door frame of Size 50mmx47mm made out of 5mm plain colour PVC Sheet reinforced with MS Square tube , Supplying & fixing in Openings as per specification and Drawing shown MES SSR.
S&F Factory Made Solid PVC Moulded Door Shutter, with particle board core, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front face & 2mm plain colour PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing shown MES SSR.
S&F extruded aluminium butt hinges size 100mm with galvanised mild steel hinges pin anodised and fixed type B-21 complete all as specified and directed.
S&F anodised barrel tower bolt 150mm of extruded section and fixed complete all as specified and directed.
S&F aluminium handle cast type anodised of size 150 mm complete all as specified and directed.
S&F aluminium alloy anodised sliding door bolt 200mm length with hasp staple and fixing clips of sheet cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified and directed.
S&F Steel ventilator with top hung shutter including hinges, steel peg stay complete all as specified and directed.
S&F Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed.
Supply only 3mm thick figured glass pin head type glazing with oil putty in square not exceeding 0.5 Sqm in each pane complete all as specified and directed.
S&F Vitreous china wash down water closet pan (pedestal pattern) white (excluding flushing cistern and flush pipe) and including fixing of the following components viz. pedestal pan with "P" or "S" trap, seat and cover for pedestal pan including jointing to socket of flushing rim and connecting pipe to union of flushing cistern, inlet and overflow pipe, anti-syphonage pipe or stopper complete all as specified and as directed. Note:- S&F Flushing cistern and flush pipe as required shall be measured and paid for under supply only separately
S&F 10 ltrs capacity PVC low level valve less flushing cistern (white) syphonic action type with all fittings such as inlet ball valve, float, and handle 32 mm dia polythene high density flush pipe and connected to squat pattern complete all as specified and directed.
S & F vitreous china wash hand basin, white flat/angle back size 550 x 400 mm complete incl necessary cutting holes and pinning in ends of brackets and 1mtr long and 32 mm bore PVC waste pipe and 32 mm PTMT waste coupling complete all as specified.
S&F 15 mm bore stop valve ISI marked, cast copper alloy, screwed down, high pressure, fancy type handle screwed both ends for iron pipe or for unions and fixed complete all as specified and directed.
S&F 15 mm dia bib tap, chromium plated, cast copper alloy with fancy type handle screwed down, screwed for iron pipe complete all as specified and directed.
S&F pillar tap 15 mm bore, cast copper alloy, with capstan head, chromium plated, screwed down high pressure, with or without lettered 'Hot or cold' with long screwed shanks and fly nuts, screwed for iron pipe complete all as specified and directed.
S&F PVC connection 450 mm long with brass coupling on both end suitable for 15 mm bore of pipe complete all as specified and directed.
S&F chromium plated tubular towel rail 20mm dia D type 60cm long between flanges complete all as specified and directed.
S&F for Shelf of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats(Minimum weight 300gms) complete all as specified and directed.
S&F Chromium plated fancy type Hand Jet spray (Health faucet) complete all as specified and directed.
S&F Chromium plated toilet paper holder fancy type etc complete all as specified and directed
Supply, laying and testing 15mm bore galvanised steel water tubing medium grade, with all fitting fixed to walls, laid in floors/ceiling and complete all as specified and directed.
Supply, laying and testing 15mm bore galvanised steel water tubing medium grade, with all fitting fixed to walls, laid in floors/ceiling and complete all as specified and directed
S&F for 100mm dia cast iron soil, waste and vent pipes, in any length with or without ears, with cement joints, fixed to wall etc complete all as specified and directed
S&F 100mm dia Cast iron soil, waste and vent pipes, in any length with or without ears, with cement joints, laid in trenches or in floors complete all as specified and directed
S&F for 100mm dia Cast iron Bends (any radius) with duck’s foot or heel rest complete all as specified and directed
S&F for 100mm dia Cast iron Branch pieces, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches with oval access doors complete all as specified and directed
S&F for 100mm dia cast iron floor trap, with grating including jointing to waste pipe fixed in cement concrete 1:2:4, type B1(Using 20 mm gaded stone aggregate) complete all as specified and directed
S&F for 100mm dia cast iron cowls complete all as specified and directed
M&L for cutting chases, pinning in making good to facings where required pointing in cement mortar 1:3 to end or edges of landing, steps cills, sunshades, shelves,lintels etc. and cutting chases for concealed watertubing or concealed conduit wiring etc. and making good, cutting not exc 10 cm girth in brick walls complete all as specified and directed.
M&L for mild steel framed works as of angles or tees, fixed independently cut to shape drilled including bending and welding angles of grade Fe-410 completed all as specified and directed
M&L for Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering, doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging, also fastening and fixing complete all as specified and directed
Preparation of new surfaces of steel and applying two coats of synthetic enamel paint over one coat of red oxide primer of any description over 10cm girth or width not otherwise described complete all as specified and directed
S&F Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of green colour having tensile strength of 550 Mpa as in roof covering to wall fixed with self-tapping screws complete all as specified and directed
S&F plate girder or single stanchions, built up of one beam or channel section with flange plates, caps, bases splices angle brackets cleats and other connections complete all as specified and directed
Excavation in trenches n. exc.1.5m wide and n. exc. 1.5m in depth for foundation etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n. exc. 10 Sq.m. on plan and n. exc. 1.5m in depth and getting out in soft/loose soil complete all as specified and as directed by the Engineer-in-Charge.
M&L for PCC 1:4:8, type D2 (Using 40mm crushed tone aggregate) as in sub base of flooring, mass concrete, foundation etc complete all as specified and directed
M&L for PCC 1:3:6 type C1 (Using 20mm stone aggregate) as in flooring complete all as specified and directed
M&L, 10 mm dia and over High strength deformed bars ( TMT bars) cut to length ,bent to shape required including cranking bending, binding with annealed wire not less than 0.90mm complete all as specified and directed.
Use and waste of form work to sides of pillars, posts, piers and column etc rough finished surface of concrete complete all as specified and directed.
M&L RCC M-25 (Design mix) as in columns, pillars, piers, post and strut complete all as specified and directed.
S&F steel work in tubular including special shaped washers etc. complete using ERW or induction butt welded tubes conforming to I.S 1161-1979 St grade St-240 complete all as specified and directed.
M & L for PCC 1:5:10, Type E2 (Using 40mm graded aggregate) as in foundations, filling and mass concrete complete all as specified and directed.
M&L for 4 mm thick galvanised chequered plate laid/fixed over cable duct complete all as specified and directed Engineer-in-Charge
M&L for MS bolts & nuts of 60mm long and 18mm dia complete all as specified and directed Engineer-in-Charge
Supply & fixing of PVC wall panelling in double layer sheet for panel & inner framework. The strips should have in their centre a grave of 6mm & 1mm depth for sinking the head of the screw used to fix the strips to the wall vertically at an equal interval between two PVC strip. The PVC strips shall be fixed to the wall using steel screws through the groove in the PVC strip by using PVC fasteners panels are joined through solvent content. Wall panelling S Side prelam sheet complete all as specified and directed. Make : DECO India Cat Part No. – 0039 (or) Techno commercially equivalent model in M/s Rajshri Plastiwood Pvt Ltd/M/s Sintex Industries Ltd
S&F venation blind vertical type level or ultima 100mm width of strip with necessary pulling threads aluminium channel along with all arrangement fixed to wall completed all as specified and directed.
Taking down Chowkats or frames with shutter exceeding 1.5 Sqm but not exceeding 4 Sqm each (Without taking off shutters from the frames) complete all as specified and directed.
Taking down chowkats or frames not exceeding 1.5 sqm each (without taking off shutters from the frames) & removing from site complete all as specified and directed
S&F for 12mm tinted toughened glass doors/window including itching/engraving on glass alongwith all necessary fittings/ fixtures as necessary & Godrej 7 lever locking system and Biometric locking system of any size/ type complete all as specified and directed.
S&F Powder coated aluminium door single/double leaf with anodized aluminium frame sliding/openable sections 62.5x37x2.5 mm thick shutter with bottom & middle rail of section 112.5x37x2.5mm and style & top rail of section 83x37x2.5mm thick including wheels/rollers with centrally locking arrangement with lock rail of "Godrej 7 lever self-closing device/system, including jointing cleats, builders hardware/fittings, floor springs, glazing with 5.5mm thick ordinary plain sheet glass, Aluminium wire mesh shutter, aluminium snap beads as necessary for completing the work complete all as specified and directed. Note : (i) Weight powder coated aluminium sections, aluminium snap beads, aluminium wire mesh will only be considered for payment (ii) Supply only 5.5mm thick ordinary plain sheet glass and Supply only Godrej 7 lever self-closing device/system will be measured and paid separately (iii) All other items except items as mentioned in the Note (ii) are deemed to be included in the unit rate quoted.
S&F Powder coated aluminium window double leaf /three leaf with anodized aluminium frame sliding/openable sections 62.5x37x2.5 mm thick shutter with bottom & middle rail of section 112.5x37x2.5mm and style & top rail of section 83x37x2.5mm thick including wheels/rollers with locking arrangement, jointing cleats, builders hardware/fittings, glazing with 5.5mm thick ordinary plain sheet glass Aluminium wire mesh shutter, aluminium snap beads as necessary for completing the work complete all as specified and directed. Note : (i) Weight powder coated aluminium sections, aluminium snap beads, aluminium wire mesh will only be considered for payment (ii) Supply only 5.5mm thick ordinary plain sheet glass will be measured and paid separately (iii) All other items except item as mentioned in the Note (ii) are deemed to be included in the unit rate quoted.
Supply only 5.5mm thick ordinary plain sheet glass complete all as specified and directed.
Supply only Godrej 7 lever self-closing device/system suitable for aluminium doors complete all as specified and directed.
S&F powder coated aluminium anodized grills with 6x5mm aluminium section having square gap of 100mm fixing with aluminium powder coated channel 12 to 15 mm (Gap for fixing grill) complete all as specified and directed.
M&L for providing POP (Plaster of Paris) cornices 100mm wide of required design as directed by Engineer-in-Charge.
S&F POP (Plaster of Paris) false ceiling over GI snap grid perimeter wall channel 25x25m fixed on wall all round, GI main ceiling channel with flange 50x25mm @ 250mm C/C, cross GI channel section 25x12 mm @ 750 C/C alongwith the suspenders of GI angle 25x25 mm @ 1200 mm C/C. 20 to 25 mm thick POP lath pestering over not less than 0.56 mm thick wire gauge in complete ceiling including form work. Ratio of POP and wall putty shall be 1:10 and applying two coats of oil bound distemper over a alkali resistant primer after preparing the POP surfaces complete all as specified and directed.
M&L for anti static vinyl flooring 2 mm thick fixed with adhesive as per manufacturer instructions over copper strip 0.50 mm thick 75 mm width fixed with adhesive in concrete floor in 1.0 mm meter grid projected to skirting 10 cm height including dismantling of existing tiles complete all as specified and directed
Taking down carefully the existing aluminium/copper paint wiring of any size and capacity and type by disconnecting from the either terminals complete including fittings and fixtures such as switches, sockets, ceiling rose, fan regulators, lamp holders, call bell, bell pushes any type etc b unscrewing and taken away from site complete and make good the disturbed surface as existing. Note : Cost of unserviceable materials will be charged from the contractor against schedule of credit
M & L for point wiring with PVC insulated, PVC unsheathed cable single core, nominal area 1.5 sq mm FRLS with stranded copper conductor 1100 volts grade drawn into and incl rigid PVC conduit (concealed) 19 mm internal dia with all PVC conduit fittings such as Tees, elbows, bend, reducers etc and 1.5 sq mm unsheathed copper conductor earth wire connected to earth dolly incl CI/MS boxes 1.6 mm thick with two coats of anticorrosive paint outside and aluminum paint inside sunk in wall with 3 mm thick laminated bakelite Hylam/Arkay light brand sheet cover (white) for mounting of switches, sockets and switch sockets, regulators as required complete all as specified and directed. Note :- The rates of chase cutting on wall concealing conduit and steel terminal boxes are included in the unit rates.Note- colour code of wire will be strictly followed , Red for Phase , Black for neutral and green for earth wire. (a) For one light point/fan/Exhaust fan point controlled by one switch
All as per Sl Item No. 92 above but one three pin socket out let 5 Amps on independent board
All as per Sl Item No. 92 above but one three pin socket outlet on same board
All as per Sl Item No. 92 above but Modular Socket out let independent but below the switch board of light points in the same vertical plane complete all as specified and directed
All as per Sl Item No. 92 above but using 2.5 Sqmm PVC FRLS insulated copper conductor wire for connecting 15A socket on independent board complete all as specified and directed.
All as per Sl Item No.92 above but with 4 Sq mm PVC insulated and PVC unsheathed cable for 3 pin 15 Amps power point on independent board 4 Sq mm copper PVC unsheathed as earth wire complete all as specified and directed
S&F Modular Switch single pole one way 6A, 230 Volts complete all as specified and directed
S&F ceiling rose surface type 3 terminals 65x20mm complete all as specified and directed
S&F Modular Socket outlet 2 in 1, 2/3 pin, 5 Amps complete all as specified and directed
S&F Modular Socket 6A/16A- 2/3 pin combined 2 module complete all as specified and directed.
S&F Modular Switch single pole one way 16A, 230 Volts complete all as specified and directed.
S&F sheet steel enclosure MCB DB SPN 8 way with 200 Amps rated bus bar horizontal type 230 Volts IP 43 protections with double metal door complete all as specified and as directed by the Engineer-in-Charge.
S&F in repairs MCB SPN, 32 Amps rating, 230 Volts, C series complete all as specified and directed
S&F MCB, SPN, 35 to 63 Amps rating, 230 Volts, C series complete all as specified and directed
S&F in repairs MCB, SP 06 to 32 Amps 230 Volts complete all as specified and directed
S&F MCB TPN DB, Vertical type made up with sheet metal, phosphorised, power coated, neutral link, earth bar and din rail, 4 way TPN with 200 Amps rated bus bar, 240 volts complete all as specified and as directed.
S&F MCB FP 100 Amp capacity, 415 volts, 16 KA breaking capacity, C series complete all as specified and directed
M&L of Sub main wiring with single core PVC insulated unsheathed, 1100 Volts grade, (FRLS) copper cable 6 Sq mm stranded conductor and drawing through PVC conduit medium duty (ISI Marked) concealed with conduit accessories such as junction boxes, bends, tees etc. Including continuous earth wire PVC insulated unsheathed 1100 volts grade, cable 6 Sqmm copper conductor and connected to common earth dolly completed as directed including taking down old sub-main wiring complete all as specified and directed Note:- (a) Two runs of 6 sqmm cable and one run of 6 Sqmm cable as earth lead with conduit shall be measured as one unit length for payment. (b) Quoted rate shall deem to be included cost of cutting chasses in wall for concealing conduit and making good to match with existing finish.
M&L of Sub main wiring with single core PVC insulated unsheathed, 1100 Volts grade, (FRLS) copper cable 10 Sqmm stranded conductor and drawing through PVC conduit medium duty (ISI Marked) concealed with conduit accessories such as junction boxes, bends, tees etc. Including continuous earth wire PVC insulated unsheathed 1100 volts grade, cable 6 Sqmm copper conductor and connected to common earth dolly completed as directed including taking down old sub-main wiring complete all as specified and directed. Note:- (a) Two runs of 10 Sqmm cable and one run of 6 Sqmm cable as earth lead with conduit shall be measured as one unit length for payment. (b) Quoted rate shall deem to be included cost of cutting chasses in wall for concealing conduit and making good to match with existing finish.
S&F round down lighter 8 watt 6500K, 240 volt 50Htz recess mounted 150 lumen/watt inbuilt driver detachable, cut out dia 94mm complete all as specified and directed.
S&F 200x200mm square LED Panel recess mounting, 240 volt 50Htz 6500 K, system lumen 150 lumen/watt complete all as specified and directed.
S&F in repairs AC starter unit consisting of one 25 Amp capacity starter, one 240 V 25 Amps 10 KA SPN MCB, one 25 Amps socket and one 25 Amp plug top prewired complete all as specified and directed. Make : North West/ Anchor / Legrand
S&F star rated wall mounted fan 450 mm sweep, left & right rotation, inbuilt regulator, 240 volt 50 Htz Including fixing arrangement complete all as specified and directed. Make : Bajaj/Crompton/Havells
S&F spot light 3 watt 240 volt 50 Htz inbuilt driver duly fixed in show case at Bar room 6500k/3000k complete all as specified and directed.
S&F wall mounted decorative fancy type bedroom light LED type with frosted glass mounted on metallic frame with holder including 12 watt LED bulb complete all as specified and directed. Make: Philips Cat Part No.31434 [or] techno commercially equivalent equivalent model in Bajaj/Havells/Crompton/Wipro
S&F Switch piano 16 A 1 way, 1 module complete all as specified and directed
S&F Switch piano 6 A 1 way, 1 module complete all as specified and directed
Supply, fixing and testing LED flood light fitting including luminare 100watt made up to pressure die cast housing with toughened glass and individuals LED's with secondary optics and IP65 protection LED efficacy more than 100Lm/Watt, 6500K, PF not less then 0.95 THD< 10% suitable for mounting on iron channel and angle iron, necessary pre cast connector for connecting wire complete all as specified and directed
M&L for Sub main wiring with four runs of single core 4 Sqmm (nominal area) PVC insulated and unsheathed multi stranded copper conductor cable LT 1100 Volts grade drawn through and including PVC conduit of adequate size and surface with all necessary fitting fixing on steel structure and accessories and one run of PVC insulated and unsheathed single core cable with copper conductor of size 4 Sqmm as earth wire (green in colour) run through conduit and connected to common earth dolly, including taking out the old one two run of cable one run of casing caping and one run of earth continuity wire for connection to DBs/dolly shall be deemed to be included in this item and shall be measured as one run complete all as specified and directed. Note:- (a) Four runs of 4 Sqmm cable and one run of 4 Sqmm cable as earth lead with conduit shall be measured as one unit length for payment. (b) Quoted rate shall deem to be included cost of cutting chasses in wall for concealing conduit and making good to match with existing finish.
S&F vertical Load line distribution board, double door 8 way SPN fitted with busbar, neutral links, blanking plates (without MCCB) complete all as specified and directed by Engineer-in-Charge.
S&F of MCB, SPN, 32 to 63 Amp rating, 230 volts, 'C' series fixed in DBs catered here-in-before complete all as specified and directed by Engineer-in-Charge.
Supply , laying & testing 2 core 10 Sqmm cable XLPE insulated screened PVC bedded , galvanised steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 1100 volts grade complete all as specified and directed
Returning, filing in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and directed
Removing excavated surplus soil to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and directed
Supply and lay clean river bed sand as sand cushioning for cables 8 cm below the cable and 15 cm above the cable complete all as specified and directed. Note :- Punned thickness will only be measured and paid.
Supply and lay sub class ‘B’ bricks (old Size) ,common burnt clay building bricks for cable protection laid length wise perpendicular to the axis of cable, abutting each other gap should not more than 10mm complete all as specified and directed
M&L for GI tubing 40 mm dia light grade with all necessary fittings laid in trenches flxed to walls, poles, under road/floor etc for cable protection complete all as specified and directed.
Fixing only split AC unit [Indoor and outdoor units] of 1.5 ton capacity all as required including necessary connections complete all as specified and directed . Note :- Split AC unit (Indoor & out door units ) will be issued under Sch 'B' free for fixing
Fixing only split AC unit [Indoor and outdoor units] of 2.0 ton capacity all as required including necessary connections complete all as specified and directed . Note :- Split AC unit (Indoor & out door units ) will be issued under Sch 'B' free for fixing
Fixing only Voltage stabilizer for automatic operation of capacity 5 KVA complete all as specified and directed . Note :- Voltage stabilizer will be issued under Sch 'B' free for fixing
S & F sheet metal enclosure with socket and plug top and MCB single pole and neutral enclosure with two Pin and earth plug and socket complete with one single pole MCB, 240 V, 20 Amp complete all as specified & directed.
M&L for laying of copper tubing of dia 1/2" including insulation with heavy duty rubber foam and brazing work completed all as specified and as directed by Engineer-in-Charge
M&L for laying of copper tubing of dia 1/4" including insulation with heavy duty rubber foam and brazing work completed all as specified and as directed by Engineer-in-Charge
S&F 3 core flexible copper cable of size 4 Sqmm complete all as specified and as directed by Engineer-in-Charge
S&F low density polyether pipe (LDPE) of pressure rating 6Kg/Sqcm drain pipes of size 20mm from indoor unit to exist point as per design including accessories clamps fasteners complete all as specified and as directed by Engineer-in-Charge
M & L for Sub main wiring with 2 runs of single core PVC insulated and PVC Unsheathed, multi-stranded copper conductor of nominal area 4 Sqmm FR, 1100 Volts grade cable drawn into and including rigid non metallic PVC Conduit of including all fittings and one run of PVC insulated and PVC unsheathed, multi-stranded copper conductor of nominal area 2.5 Sqmm FRLS 1100 volts grade cable continuous earth wire of green colour code complete all as specified and directed. Note:- (a) Two runs of 4.0 sqmm cable and one run of 2.5 Sqmm cable as earth lead with conduit shall be measured as one unit length for payment. (b) Quoted rate shall deem to be included cost of cutting chasses in wall for concealing conduit and making good to match with existing finish.
M&L for laying of copper tubing of dia 5/8" including insulation with heavy duty rubber foam and brazing work completed all as specified and as directed by engineer-in-Charge
M&L for laying of copper tubing of dia 3/8" including insulation with heavy duty rubber foam and brazing work completed all as specified and as directed by engineer-in-Charge
M&L for outdoor unit stand for wall mounting type or floor mounted complete factory made as recommended for make Air conditioner and approved by Engineer-in-Charge
M&L for Shifting and re-fixing of split type AC (Indoor and Outdoor units) of any make and any type after servicing and charging of gas (M410a/R134a/R-22/r32) by testing the leakage in system and repairing of leakage if any by gas welding work, cleaning and flushing out the complete system with gas, supply and replacing of drier/filter, making the complete system leak proof, vacuuming the system as existing and testing etc complete all as specified and directed. Note : (a) : The unit rate quoted is deemed to be inclusive of dismantling and re-fixing of split AC complete. (b) The unit rate quoted is deemed to be inclusive of drier capillary, copper tubing, refrigerant gas, Insulation and LDPE pipe (c) The unit rate quoted is deemed to be inclusive of making hole and filling the hole & making good the disturbed surfaces with existing colour matching.
S&F snap on trunking 50 mm x 105 mm, 1 mm thick compartment with duct cover on wall for copper tubing of AC including accessories clamps fasteners complete all as specified and as directed by Engineer-in-Charge
S&F bulkhead fitting environmental friendly, ultra modern, energy saving, surface mounted, decorative oval bulkhead edgelit LED luminaire comprising of high brightness LEDs of 10 watt complete all as specified and directed.
M&L of Sub main wiring with single core PVC insulated unsheathed, 1100 Volts grade, copper cable 6 Sq mm (FR) stranded conductor and drawing through PVC conduit medium duty (ISI Marked) concealed with conduit accessories such as junction boxes, bends, tees etc. Including continuous earth wire PVC insulated unsheathed 1100 volts grade, cable 4 Sqmm (FR) copper conductor and connected to common earth dolly completed as directed including taking down old sub-main wiring complete all as specified and directed Note:- (a) Two runs of 6 sqmm cable and one run of 4 Sqmm cable as earth lead with conduit shall be measured as one unit length for payment. (b) Quoted rate shall deem to be included cost of cutting chasses in wall for concealing conduit and making good to match with existing finish.
S&F LED batten extruded surface mounting light fitting 2 feet long aluminium housing 10 watts input voltage, 220 volts, inbuilt LED and driver complete all as specified and directed. Make:- Philips Cat Part No. BN021LED 10S-6500PSU GR S1 (or) techno commercially equivalent model in Crompton/Havells/Wipro/Bajaj as approved by GE
S&F security light luminaries LED 25 watt 240 Volts made out of aluminium housing toughened glass IP-65 protection 6500 K incluidng GI brackets, nuts, bolts etc complete all as specified and as directed by Engineer-in-Charge
Note :- Credit shown in credit schedule of tender document shall be considered by the tenderer while quoting the rates of various items of this schedule. The same shall be recovered from various payment to contractor before handing over old material.
M/S Rakesh Singh
FRIENDS N FRIENDS
ANSARI REFRIGERATION
A S ENTERPRISES
Pleiad Complex On
M/S SATISH KUMAR
M/s RN Kharwar & Sons
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .