Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.0 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹30.2 L+₹41,516.40 (1.40%)Rejected-Finance | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹43.8 L+₹14.1 L (47.3%)Rejected-Finance SHIV BARI ROAD NEAR KASUMAL HOTEL BIKANER 334003 RAJASTHAN | BIKANER | BIKANER | RAJASTHAN | 334003 | L3 | Rejected-Finance Other than lowest bidder | |
| 4 | Rejected-Technical WARD NO 02 LAKHUWALI PO THE PILIBANGAN DISTT HANUMANGARH RAJASTHAN 335803 | HANUMANGARH | RAJASTHAN | 335803 | - | Rejected-Technical Not Enlisted category |
Tender Value
₹46.5 L
EMD Value
₹93,000
Closing Date
6 May 2020, 6:00 pmClosed
GE (N) Bikaner
GE (N) BIkaner Bikaner MIL Station Bikaner
OUTSOURCING SERVICES FOR OPERATION OF EXTERNAL WATER SUPPLY AND ELECTRIC SUPPLY INSTALLATION AT VARIOUS LOCATION AND OTHER CONNECTED ITEMS AT NORTH AND WEST CAMP AT MFFR UNDER GE (N) BIKANER
2020_MES_335947_2
GE (N) BKN-Token/68/2019-20
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
Bikaner
Class D Category d (v)
8 documents required · 8 mandatory
₹500
GE (N) Bikaner
₹93,000
Yes
1 Mar 2021
22 Apr 2020
8 May 2020
22 Apr 2020
6 May 2020
22 Apr 2020
Amount
(Note for Sl Item No. 1 to 6 : The rate quoted shall not be less than minimum wages as notified by Government/Local body whichever is higher . In Case the rates quoted are less than the minimum wages as notified by the Government of India/State Government/Local body whichever is higher his tender will be treated as NON BONAFIDE and willl not be considered for acceptance. In such case, the lowest tender shall be determined by the lowest amount amongst valid/bonofied bids only). Outsourcing of services for Rajana minor pump house installation with DG set including filling of raw water storage tank from minor canal head, mixing of alum in raw water & pumping the raw water into slow sand filter tank and chlorination of clear water in collection/clear water storage tank & pumping the same treated clear water to RCC over head reservoir tank at North Camp by operating one trade men (FGM) in one shift (day shift) & one helper will providing the water from minor canal & other general duties as required at site in another shift (evening shift) including Sunday and holiday (each shift of 8 hours duration) as required for smooth functioning of installation at site complete all as specified and directed by Engineer-in-Charge. Note :- Transport/Vehicle & manpower for loading/unloading of FOL will be arranged by the contractor for collection of Fuel/FOL for DG set from KSP North Camp (approx. 19 Kms).The cost of the same shall be deemed to be included the unit rate quoted by contractor. Note Applicable for srl item No. 1 to 6 (serial item no - one to six ): - (a) All the electric equipment/panels installed in pump house/External electric panels will be maintained properly by contractor. (b) Timing and location of deployed staff will be decided by Engr-in-Charge. (c) General cleaning of installations area to be upkeep by the staff employed by contractor & removing all vegetation nearby installations & cutting grass & vegetation time to time. (d) Staff employed by the contractor at installation having the general knowledge of operating generator, pumping motor, electric panels & all necessary operation required to supply water to all camp area i.e. North, West,. (e) Cost of log sheet and relevant document to be maintain by contractor which is included in the item rate quoted as per requirement for operating pump house installations/electric installation included in lump sum quoted rate. f) Necessary cleaning of slow sand filter tank and excavation work required to filter media at every operation included in the quoted rate. g) Cost of petty items required for smooth functioning of installation such as grease for moving parts of pumps, glands, cotton waste, brooms, testing kits for chlorination testing to be provide by the contractor on each installation. (Note for Srl Item No 01 here in before above contd..(h) Contractor provide necessary conveyance for collection of P.O.L. for generator from North Camp to all installation as and when required at installation.(j) Contractor provide all required T&P at installation for operation/outsourcing and other safety equipments, ladder, over combination, grass, vegetation cutter etc. (k) If any loss/damage to govt property is caused by contractor due to operator's fault during operation, the same shall be make good by contractor at the same cost quoted by him for outsourcing. (l) Contractor must submit following documents within 15 days from commencement date and if any Elect/FGM/helper is found absent from duty found Rs. 1000/- day penalty will be deducted from contractor dues: - (aa) Application for issue the identity card/security pass.(ab) Cost of T&P/vehicle reqd for outsourcing & repair work such as fuse wire, insulation tape, working tools to be borne by the contractor & provided by contractor at each installation for daily attendance bio metric is to be installed by contractor for which the cost is to be included in the item rate quoted.(ac) The cost of material will be measured and paid separately (ad) Tradesmen/Helpers will be made Payment through e-payment/cheque and the evidence/proof of the same monthly contractor will provide. (ae) motor will be under warranty for six month after rewinding of motor and contractor will reponsible for burnt winding due to operator fault like two phase opreation or due to water during this period and rewind motor his own expenses .
Outsourcing of services for sluice valves for release of water supply at over head reservoir of distribution line at North Camp area and both lorry filling points at over head tank location by providing one Helper including Sunday and holidays in two shifts per day (each shift of 8 hours duration) all as specified and as directed by Engineer-in-Charge. Timing of duty shift to be decided by the Engineer-in-Charge. Note- Contractor provide necessary T&P required for operating of sluice valve and other items such as torch light for morning and evening duty hours.
Outsourcing of services for West Camp (Devasar) Water supply installation PH -II with D.G. set including all operating activities required for smooth functioning of installation, mixing of Alum in raw water tank and pumping raw water for filtration and chlorination in storage tank, distribution the same treated water to all CULs & Adm area including supply to both lorry filling points as & when required by providing one trade man(FGM) in two shift of 8 hrs each including sunday and holiday all as specified and directed by Engineer-in-Charge. (Note :- Transport/Vehicle & manpower for loading/unloading of FOL will be arranged by the contractor for collection of Fuel/FOL for DG set from KSP North Camp (approx. 35 Kms).The cost of the same shall be deemed to be included the unit rate quoted)
Outsourcing of services for RAW water pump house PH-I, located approx 3.5 Km from west camp pump house PH-II including operating generator set of 62.5 KVA and 40 HP pump filling raw water from minor canal to raw water tank and pumping the same to Devasar pump house operate the installation round the clock including Sunday and holiday in two shift per day each shift of 08 hrs duration by providing one FGM for each shift etc complete all as specified and directed by Engineer-in-Charge. ( Note :- Transport/Vehicle & manpower for loading/unloading of FOL will be arranged by the contractor for collection of Fuel/FOL for DG set from KSP North Camp (approx. 37.5 Kms).The cost of the same shall be deemed to be included the unit rate quoted)
Outsourcing of services for elect supply including substation 11 KV LT side and all day to day repairs required such as security light repair, rectification of faults in LT/HT overhead lines, internal elect supply repairs complete in New Camp (Cul-1,2,3 &4) including Adm Camp in North Camp and all other camps i.e. Adm Area with CUL-1 to 5 under AGE MFFR by providing one trade man electrician (SK trade) and one helper (08 hrs) including Sunday and holiday in one shift/day complete all as specified and directed by Engineer-in-Charge.
Outsourcing of services for elect supply including substation 11 KV LT side and all day to day repairs required such as security light repair, rectification of faults in LT/HT overhead lines, internal elect supply repairs complete in New Camp (Cul-1,2 3,4 &5) including Adm Camp in West Camp and all other camps i.e. Adm Area with CUL-1 to 5 under AGE MFFR by providing one trade man electrician (SK trade) including Sunday and holiday in one shift/day complete all as specified and directed by Engineer-in-Charge.
Supply only Stable Bleaching Powder Grade-I confirming to IS specification 1065/1989 containing minimum chlorine percentage 34% degree packed in double limed 25 Kgs in HDPE bags duly ISI marked on requirement as directed by Engineer-in-Charge. Make : Sie/Chambal/ Shriram/ARIHANT.
Supply only Alum grade-4 ap per IS-299/1989 of best quality in 20 KG brick to the extent required in treatment of water complete all as specified and as directed by Engineer-in-Charge. (Make- Marudhar or equivalent in other approved make).
Dismantling of existing defective induction motor of the following size and make from the foundation, disconnecting the electric connecting coupling pulley and taking out to work shop cutting down and removing existing burnt out copper windings, cleaning of slots and rewinding with solid copper conductor (winding wire) complete including varnishing, drying ovening overhauling greeasing and fixing in the same position making necessary electric connection and testing on induction motor complete all as specified and as directed by Engineer-in-Charge. 40 HP capacity, 03 phase, 415 volt 50 HZ any make/type
Ditto all as per item no 9.00 but capacity of 15 HP capacity, 03 phase, 415 volt 50 HZ any make/type
Ditto all as per item no 9.00 but capacity of 7.5 HP capacity, 03 phase, 415 volt 50 HZ any make/type
Ditto all as per item no 9.00 but capacity of 5 HP capacity, 03 phase, 415 volt 50 HZ any make/type
Ditto all as per item no 9.00 but capacity of 3 HP capacity, 03 phase, 415 volt 50 HZ any make/type
Dismantling from foundation frame by disconnecting suction/delivery lines and coupling opening and transport to workshop and re-assembling after repair/replacement of defective parts of centrifugal pump set of capacity 40 HP, Make :- any make and replacement of worn out spare parts as mentioned under respective item No-15 here in after.
Supply only the following spare parts for cetrifugal pump of 40 HP capacity make :- any make Inter stage ring
Gland cap CI with Nut bolt
Shaft sleeve bronze
Set of gasket
Bearing with housing DE
CI Impeller with locking screw & Nut
Dismantling from foundation frame by disconnecting suction/delivery lines and coupling opening & transport to workshop & re-assembling after repair/replacement of defective parts of centrifugal pump set of capacity 20 HP Make :- any make and replacement of worn out spare parts as mentioned under resective item No-17 here in after.
Supply only the following spare parts for cetrifugal pump of 20 HP capacity make :- kirlosker/CG /Kalsi Inter stage ring
CI Impeller with locking screw & Nut
Gland cap CI with Nut bolt
Shaft sleeve bronze
Set of gasket
Bearing with housing DE
Dismantling from foundation frame by disconnecting suction/delivery lines and coupling opening & transport to workshop & re-assembling after repair/replacement of defective parts of centrifugal pump set of capacity 12/15 HP Make :- any make and replacement of worn out spare parts as mentioned under resective item No-19 here in after.
Supply and fixed in replacement following items suitable for 12.5/15HP motor pumping set CI Impeller with locking screw & Nut
Ditto all as per item no 19.00 but for Ball bearing for motor (SKF/NBC)
Ditto all as per item no 19.00 but for Ball bearing as per existing for Pump (SKF/NBC)
Supply & Fix in replacement of the following parts of mono-block capacity 7.5 to 10 HP, Make-Kirloskar, Discharge 540 LPM at head 2980 RPM CI Impeller with locking screw & Nut
Ditto all as per item no 22.00 but for Ball bearing as per existing for pump/motor
Supply & fix in replacement of the following parts of mono-block capacity 3/5 HP, Make-Kirloskar, Discharge 540 LRM at 16 head 2840 RPM CI Impeller with locking screw & Nut
Ditto ll as per item no 24.00 but for Ball bearing as per existing for pump/motor
Cleaning of raw water reservoir of capacity 8500KL of 5 metre depth complete by drain out water below the suction pipe by temporary pump arrangement by contractor and taking out sludge/foreign particle from bottom of reservoir by manually or mechanically and depositing at a distance of 200mtr away from the reservoir and cleaning all the walls of reservoir by metal brush and repairing the cracks and damages in walls and floor as per requirement of site and making good with cement and sand mortar, painting of wall and bottom of reservoir with 02 coats of cement base paint & Black and white painting in water proof of measurement scale, cleaning/removing sand and mud around the reservoir up to 5 meter circumstance of reservoir including removing grass and bushes at phase-II West Camp, Devaser water point complete all as specified and directed by Engineer-in-Charge. (Note:- The contractor shall write in white letters on black base colour with date of cleaning and next due date of cleaning with capacity of underground tank/sump/OHSR etc)
Ditto- all as per srl No 26.00 here-in-before but capacity of reservior is 6700 KL at west camp water point kharbara road PH-I.
Ditto- all as per srl No 26.00 here-in-before but capacity of reservior is 3400 KL at North Camp phase-I (Rajana minor pump house)
Cleaning of over head reservoir 190 KL capacity complete by drain out water taking out sludge foreign particle from bottom of reservoir and depositing at a distance of 100mtr away from the reservoir cleaning of wall of same by metal brush. Repairing the cracks and damages in wall and floor as per requirement of site and making good with cement and sand mortar. Painting of wall, outside area of OHSR and bottom of reservoir with 02 coats of cement based paint at at Rajana Water point. water point complete all as specified and directed by Engineer-in-Charge.
Cleaning of PVC Overhead tank 10x10000 liters capacity (i.e. 100 KL)complete by drain out water taking out sludge foreign particle from bottom of all tank and depositing at a distance of 100mtr away from the water point and cleaning of staging roof including all necessary materials and tools at West Camp Ph II Devasar complete all as required at site and directed by Engineer-in-Charge
Cleaning of underground sump of clear water reservoir 95 KL capacity complete by drain out water taking out sludge foreign particle from bottom of reservoir and depositing at a distance of 200mtr away from the sump, cleaning of wall of same by metal brush. Repairing the cracks and damages in wall and floor as per requirement of site and making good with cement and sand mortar. Painting of wall, MS Sheet cover plate, outside area of CWR and bottom of reservoir with 02 coats of cement based paint after inside and outside cleaning/removing sand and mud inside the sum & removing the same up to 5 mtr around the sump including removing grass and bushes At Rajana Water point water point complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of cast iron sluice valve 80 mm, heavy duty class PN 1:6 ISI marked (IS-14846-2000), long body, both ends flanged, complete with high tensile stainless steel spindle, cast iron hand operated wheel and cap top, nuts, bolts, washers including 3mm thick rubber gasket joints, suitable for 80 mm bore GI/PVC pipe any type any size and also including testing and commissioning complete all as specified and as directed.
Ditto all as per serial item No. 32.00 here in before but suitable for 100mm bore.
Ditto all as per serial item No.32.00 here in before but suitable for 150mm bore.
Ditto all as per serial item No. 32.00 here in before but suitable for 200mm bore.
Supply and fixing in replacement of existing flexible hose pipe of 80 mm dia suiatable for lorry filling point all as specified & directed by the Engineer-in-Charge.
Supply and Fixing in replacement of Reflex Valve/NRV/Dual plate check valve, PN 1.6 rating of size 80 mm dia with all necessary accessories and testing complete all as specified & directed.
Supply and Fixing in repair foot valve of any type & in any condition CI Foot Valve size 80 mm dia conforming to IS suitable for 80mm bore pipe any type i.e thread/flanged type complete all as required at site.
S&F in replacement of cast iron ditechable joints suitable for 200mm dia DI/GI pipe line including clamps, nuts, bolts, washers,sockets,elbow etc and all necessary arrangement and testing complete all as required at site and as directed.(Note:- Excavation shall be measured and paid for separately)
All as per item No 39.00 above but size 150mm suitable for 150mm dia GI/DI pipe line
All as per item No 39.00 above but size 100mm suitable for 100mm dia GI/DI pipe line
S&F in replacement of PVC ditechable joints suitable for 200mm dia HDPE/PVC pipe line including clamps, nuts, bolts, washers,sockets,elbow etc and all necessary arrangement and testing complete all as required at site and as directed.(Note:- Excavation shall be measured and paid for separately)
All as per item No 42.00 above but size 150/160mm suitable for 160/150mm dia HDPE/PVC pipe line
All as per item No 42.00 above but size 100mm suitable for 100mm dia HDPE/PVC pipe line
Suuply and Fixing in replacement of automatic starter Oil Immersed type suitable for 40HP pump set 415 volt, 50 Hz, 3 phase, by using lugs/thimbles complete all as specified and as directed by Engineer-in-Charge. Make :- L&T/Siemens/ABB/C&S
Suuply and Fixing in replacement of automatic starter Oil Immersed typ any size suitable for 15 HP pump set 415 volt, 50 Hz, 3 phase, by using lugs/thimbles complete all as specified and as directed by Engineer-in-Charge. Make :- L&T/Siemens/ABB/C&S
Suuply and Fixing in replacement of automatic starter typpe any size suitable for 7.5 HP pump set 415 volt, 50 Hz, 3 phase, by using lugs/thimbles complete all as specified and as directed by Engineer-in-Charge. Make :- L&T/Siemens/ABB/C&S
Suuply and Fixing in replacement of automatic DOL starter type any size suitable for upto 5 HP pump set 415 volt, 50 Hz, 3 phase, by using lugs/thimbles complete all as specified and as directed by Engineer-in-Charge. Make :- L&T/Siemens/ABB/C&S
Suuply and Fixing in replacement of automatic DOL starter any size suitable for upto 3 HP pump set 415 volt, 50 Hz, 3 phase, by using lugs/thimbles complete all as specified and as directed by Engineer-in-Charge. Make :- L&T/Siemens/ABB/C&S
S&F in replacement of four pole offload changeover switch 200 Amps, 415 Volts with sheet steel enclosure including disconnecting existing cable connection and reconnecting after fixing the same as directed by Engineer-in-Charge complete all as specified and as directed by Engineer-in-Charge.Make :- L&T/Siemens/Havells/C&S
S&F in replacement of four pole offload changeover switch 100 Amps, 415 Volts with sheet steel enclosure including disconnecting existing cable connection and reconnecting after fixing the same as directed by Engineer-in-Charge complete all as specified and as directed by Engineer-in-Charge.Make :- L&T/Siemens/Havells/C&S
S&F in replacement of four pole offload changeover switch 63mps, 415 Volts with sheet steel enclosure including disconnecting existing cable connection and reconnecting after fixing the same as directed by Engineer-in-Charge complete all as specified and as directed by Engineer-in-Charge.Make :- L&T/Siemens/Havells/C&S
Pressure filter M & L Fine Sand with silt content not more than 5% free from all impurities (0.45 to 0.65mm) Thick (As per sample). It should be cleaned and pass through sieve no. 10 (1.67mm) and should be retain on sieve no.66 (size0.25mm) the Silt should not exceeds 2%
M&l Gravels .It should be cleaned hard & uniform quality one free from dirt, clay and organic matters .It should be laid in layer of effective size 5 mm to 40mm complete all as specified & directed
For Slow sand filter supply & dumping of filter media in bed of RCC sand filter tank of any size & depth as per specification including all lead and lift etc complete all as specified & directed at site. (Net filling volume of filter media to be measured & paid). (a) Fine Sand with silt content not more than 5% free from all impurities (0.20 to 0.30mm) Thick (As per sample). It should be cleaned and pass through sieve no. 10 (1.67mm) and should be retain on sieve no.66 (size0.25mm) the Silt should not exceeds 2%
(b) Course sand free from sit clay and all impunities (1 to 1.7mm) (As per sample) It should be cleaned and pass through sieve no. 12 (1.40mm) and should be retain on sieve no.22 (size0.78mm) the Silt should not exceeds 2%
(c ) Hard Course Randhisar Gritt (8 to 12mm) thick (As per sample) It should be cleaned hard & uniform quality one free from dirt, clay and organic matters .It should be laid in layer of effective size 5 mm to 40mm complete all as specified & directed
Taking out the existing filter media of any size from filter bed of tank any depth including removing material to a distance exceeding 50 meter not exc 100 meter complete all as specified and directed.
Cleaning and scratching the surface of filter bed walls, floor truffs, drains etc by wire brushes or otherwise to remove the deposited mud silt etc, washing and cleaning all the affected surface with water complete all as specified and directed
Cleaning, washing of existing of natural pebbles (i.e. fine/coarse sand, gravel etc) obtained from serial item No 56.00 here in before for making it free from silt and other deterious material, screening aggreegate of different size and depositing packing in layer as per direction in filter bed etc complete all as specified and directed
Excavation in trenches in soft/loose soil not exc 1.5mtr wide and not exc 1.5mtr in depth for taking out old pipe and laying new pipe line etc. not exceeding 10 sqm on plan and not exceeding 1.5 m in depth and getting out complete all as specified and as directed.
Returning and filling including spreading, levelling, watering and well ramming in layers not exc 25 cm thick in any type of soil complete all as specified and as directed.
Removing surplus soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 meter above the starting point complete all as specified and as directed.
Supplying, laying, jointing and testing ductile iron pipe spigot & socketed size 200mm dia, class K-9 suitable for rubber tyton joints duly ISI marked complete all as specified and directed by Engr-in-Charge. Note:- Excavation and earth work and joints shall be measured and paid separately.
Dismantling and taking out exisitng rusted/croded DI pipe of size 200 mm bore spigot and socketed ends of any length & type including burning of lead/rubber joints and bailing out water if necessary all as directed.
M&L for rubber tyton push on gasket joints in spigot and socketed DI pipes and fittings of 200 mm dia bore complete all as specified and directed.
Supply and fixing in replacement of existing pipe any type and size in any condition at various location including GI pipe medium grade 150 mm bore (ISI marked) laid in trenches/ road crossings/along walls/ path /drain/floors with and including clamps, nuts, bolts, washers,sockets,elbow etc and all necessary arrangement to connect existing branch pipe of any type and size including all necessary fittings required at site and testing complete all as specified and as directed by the Engineer-in-Charge. (Note:- Earth work shall be measured and paid for separately.)
Ditto all as per item No 65.00 above but size 100 mm dia.
Ditto all as per item No 65.00 above but size 80 mm dia.
Ditto all as per item No 65.00 above but size 50 mm dia.
M & L Taking up or down the existing rusted/damage GI pipe of 150/160 mm dia including all fittings and removing from site complete all as specified and directed by Engineer-in-Charge.
M & L Taking out u/s rusted corroded GI / PVC pipe of size 100/ mm dia after cutting/unscrewing including all fittings from trenches /along walls/under roar etc complete all as specified and directed.
M & L Taking up or down the existing rusted/damage GI/PVC pipe of75/80 /90 MMmm dia including all fittings and removing from site complete all as specified and directed by Engineer-in-Charge.
M & L Taking out u/s rusted corroded GI pipe of size 50 mm dia after cutting/unscrewing including all fittings from trenches /along walls/under roar etc complete all as specified and directed.
Taking down carefully existing unserviceable batten/surface conduit/ concealed conduit aluminium point wiring (light, fan, bell/buzzer, socket or power) complete including removal of unserviceable fittings such as switches, switch-sockets, ceiling roses, pendents, sockets, lamp holders, shades, fan regulators, light fittings, bells etc including sunken boxes and removing the retrieved materials from dismantling including making good the disturbed surface of walls, floors, ceilings etc to match with the adjoining work complete all as specified and as directed by the Engineer-in-Charge.
Taking down of unserviceable DBs/ switch fuses/ change over in sheet steel enclosure complete with MCBs /Fuses /grips any capacity after disconnecting all cables etc and removing from site and making good disturbed surface of wall, floor etc. complete all as specified and as directed by Engineer-in-Charge.
Point wiring with stranded copper conductor cable, 1100 volts grade (ISI marked) PVC FR LS cable of size 1.5 Sq mm stranded core in and including Surface conduct/ consealed conduct with all fittings such as tees, bends etc terminating in MS sunken box/Wooden box covered with and including 3 mm thick new bakelite laminated sheet top cover ‘Hylam’ for one fan or light or exhaust fan or bell/buzzer point controlled by one switch including provision of 1.50 Sqmm PVC FR copper conductor cable, multistranded single core as earth wire to common earth & connecting to earth dolly complete all as specified and directed by Engineer-in-Charge.
All as per item No. 75.00 here-in-before but socket point on the same board
All as per item No 75.00 here-in-before but socket point on independent board
Ditto- all as per srl item No 75.00 here-in-before but with multi stranded copper conductor cable, 1100 volts grade (ISI marked), PVC insulated FR cable of size 2.5 Sqmm single core and with and including 2.5 Sqmm PVC FR single core copper standed conductor cable as earth continuity conductor to common earth and earth dolly for one 15 Amp socket outlet point on the independent board complete all as specified and as directed by Engineer-in-Charge.
Supply and fix Switch piano flush type, Single pole 5 Amps, one way ISI marked, complete all as specified and as directed by Engineer-in-Charge.
Supply and fix Switch piano flush type, Single pole 15 Amps, one way ISI marked, complete all as specified and as directed by Engineer-in-Charge.
Supply and fix Socket outlet 3 pin 5 amp flush type, ISI marked complete all as specified and as directed by Engineer-in-Charge .
Supply and fix Socket outlet 3 pin 15 amp flush type, ISI marked complete all as specified and as directed by Engineer-in-Charge .
Supply and fix Ceiling rose, 3 terminal PVC/ polycarbonate isolated body, ISI marked, complete all as specified and as directed by Engineer-in-Charge.
Supply and fix Fan regulator electronic type 230 Volts,150 watt with 5 step control suitable for 1200/1400 mm sweep ceiling fan, complete all as specified and as directed by Engineer-in-Charge.
S&F Lamp holder PVC/ polycarbonate insulated body with black plate for conduit / casing caping complete all as specified and as directed by Engineer-in-Charge .
Supply and fix MCB DBs single pole and neutral 8 way SPN 240 Volt single door complete all as specified and directed. Make :- Havells/Indo Asian/SKF
S & F in replacement bulk head luminaries suitable for CFL lamp 1 x 9 watt with plastic enclosures and opal acrylic diffuser, including CFL lamp complete including making connection with suitable size copper flexible wire all as specified and as directed by Engineer-in-Charge
S & F in replacement of linear DLX decorative ultra slim linear LED light fitting with extruded aluminium heat sink, enviranment friendly energy efficient ready to use pack lamp type 18/20W LED 6K (4') type LHDD01102674 Make:- Halonex/Syska/Havells
Supply and Fixing MCB single pole, 240 volts of rating 6-40 Amps of C curve breaking capacity of 10 KA complete all as specified and as directed by Engineer-in-Charge
Supply and Fixing MCB suitable for 6 to 40 Amps, 240 Volt AC supply 'C' Curve single pole and neutral (SPN) with over load and short circuit protection having rupturing capacity not less than 10 KA complete all as specified and as directed by Engineer-in-Charge.
Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below normal ground level surrounded from all sides by 15 cm thick packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by means of GI wire 4 mm dia by means of bolts, nuts, check nuts and washers of GI or steel up to 7.5 metre and connecting to earthing test point, main switch board or panel, testing on completion including GI pipe 20 mm dia light grade 30 cm above ground level with plug at top for watering and GI pipe 15 mm dia light grade for the protection of GI wire from earth pit to earth point complete including necessary excavation and earth work in any type of soil, returning, filling in approved soil and disposal of surplus soil to a distance n.exc 50 m all as specified as shown in electrical plate No 3 SSR Part-I including testing on completion complete all as specified and as directed by Engineer-in-Charge. (Notes : - (i) G.I pipe 20 mm dia light grade from earth electrode upto main switch panel for protection of earth lead wire shall be deemed to be included in the unit rate quoted for earthing)
M & L Local tibba dry sand cushioning and cover (8 cm thick layer of sand before laying of cable and 15 cm thick layer of sand after laying of cable) for protection of cable, material and labour complete all as specified and as directed by the Engineer-in-Charge.
M & L Protection to cable with one layer of bricks laid flat butting to each other in such a way that the length of the bricks is at right angle to the central axis of the cable using old size sub-class ‘B’ burnt-clay bricks having compressing strength not less than 75 kg/Square cm complete all as specified and as directed by the Engineer-in-Charge.
Taking out old U/S street light or street light fittings with brackets from poles, wall etc any type and description complete all as specified and as directed by the Engineer-in-Charge.
Taking out old US/faulty PVC armoured/un-armoured LT under ground cable of size 10 Sqmm core complete all as specified and as directed by the Engineer-in-Charge.
S & F Cross linked poly-ethylene (XLPE) insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables ( heavy duty) with aluminium conductor, 1100 volts LT grade of cross-sectional area 10 Sqmm 2 core laid in trenches/through pipe in road crossings/paths/drains/ducts/floors/along poles/walls/ceilings/equipments etc supplied and fixed including commissioning and testing complete all as specified and as directed by the Engineer-in-Charge. Note : (i) Necessary excavation and earth work, brick protection, sand cushioning and cover and GI pipe shall be measured and paid for separately. (ii) Road/boring roads manualy cutting/floor cutting/cutting holes etc in wall required for laying fising of cable etc shall be made good as per existing site condition. Nothing extra shall be admissible on this account and quoted rate for this item shall be deemed to include for the same.Make:- Havells/polycab/Nicco
M&L GI bracket for street light fittings fabricated with GI tubing suitable dia light grade 1.2 m long for mounting street lights at Ser No. 30 incl painting a cost of aluminium paint over one coat of red oxide primer and bending to angle of 120 fixed in complere incl MS clamp 40 x 5 mm (02 Nos) and suitable nut & bolts for fixing the brackets as per dia fittings and pipe.
Supply and fixing Rigid steel conduit, welded for street light wire junction box to street light bracket complete all as specified.
Supply and fix MCB DBs single pole and neutral 2 way SPN 240 volt single door with MCB SPN 16 Amps complete all as specified and directed. Make :- Havells/Indo Asian/SKF
Supply and fixing in replacement New generation energy saving and environmental friendly long life LED street light 40 watt made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP Opening seperate driver compartment with IP66 protection and impact resistance of IK07. Make-.Havells Cat pt No. ENDURAPEARLNEOSL40WLED757PASYTOPC, Wipro, C&S and surya.
Supply and fixing in replacement for two core PVC insulated weather proof cable with aluminum conductor size 4 sqmm (nominal area), & drawing into hollow street light pole from fitting to juntion box or fitting to over head line complete all as specified and as directed by the Engineer-in-Charge.Make :- havells/Poly cab
Gupta Suppliers
M/s Rohit Construction Co.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .