Supply, Installation, Testing & Commissioning of Indoor and Outdoor Signalling Equipment's, Power Supply Equipment's and associated works in connection with the provision of centralized type Electronic Interlocking at SABDUA,BALUPUR and AJAYGARH station in PANNA-KHAJURAHO section and BAHARI , DEOSAR station and EI alteration at Gondawali station in Gajrahi-Singrauli section along with balance work of Khajuraho (Excluding) - Singrauli Section in connection with NEW BG Rail Line Work of Khajuraho (Excluding) -Singrauli section on WCR.
JBP-SnT-Cons-Tend-Sig-138
JBP-SnT-Cons-Tend-Sig-138
Open
18 Months
Singrauli, Madhya Pradesh
₹0
₹67.3 L
8 Jul 2026
8 Jul 2026
22 Jul 2026
indoorcables,wires,lugs,fuses,fixtures,mountingarrangements along with all accessories necessaryto make complete EI system functional.Design of EI system should be compatible as per outdoorinterlocking requirement based on signalinterlocking plan and selection table/ locking tableof station/yard.Approved SIP will be issued by Rlyand other document (such as RSP, PD VDU,ST/LT,Interface Diagram,Logic cct. Etc.) will besubmitted by contractor.This item also includes thefollowing:a)Supply aprovision of protective device like surge and lightening protection devicescompatible to RE standards as recommended byOEM/RDSO. It includes supply of all the materialwhich is required to make complete EI system tobe functional and as recommended by RDSO inspecification No RDSO/SPN/192/2019 Ver 2.0 with latest amendment One set for each EI INSPECTION BYRDSO
DY CSTE-C-JBP-S AND T/WEST CENTRAL RLY Description:- Supply of LED type, Indication cum Operating Panel to be made of exchangeable 2 Domino units each unit of size of 54mm x 34mm cover plates decipiciting the yard lay out ,unit signal , track circuit etc,of minimum size (12 x 8). Siemens type Dominos complete, wired with full components. The panel should have polycarbonate sheet cover on the top to avoid damages while in service. Each of the working domino unit should have all terminals. Total nos of domino (12X 8)= 96 Nos. size 54mm x 34mm .The length approximately 730mmX450mm.The height is approximately 910mm(rear side) and 820mm (front side) .The panel will be LED illuminated (2 Nos of magnet , 2 nos of bulb extractor & 10 % of spares of all LED's of each colour to be supplied along with panel. INSPECTED BY CONSIGNEE
Description:- Supply of DC-DC converter 24-40 V/5A or 12-28V/5A or 60-100 V/1A or any other
1.0 (Or latest).Contractor will take approval before supply of this item. (with Input/output connection) for IPS.INSPECTION BY RDSO
Description:- Supply of documents ( Manuals for installation, Testing commissioningand maintenance of the system) one set consists of 6 sets of followingdrawings per station. (i) Manual for installation, Testing, Commissioning and maintenance of the system forTechnicians/Jr Engineers. (installation & Maintenance level) (ii)Functioning and system overview(higher management level)
plans to suit layout given in the signalling plan for hot standby arch.Electronic Interlocking system. All plans and wiring diagrams shall beprepared on autocad drawing andsupplied with CD. This will includesupply of Control cum indication panel/VDU diagram, square sheet,wiring diagram ( Application logicand interface circuit), Fuse analysis,contact analysis, Tag Block Analysis,power supply distribution/ Power equipment arrangement (withprogram switch), diagramautochangeover diagram(if supplied by the contractor) and all otherrelevent drawings. INSPECTION BY CONSIGNEE
Description:- Supply of PC and laptop based work station (makeHP/DELL/IBM/Apple) for data input
commissioning of EI system. (Minimum cofiguration : HP intel core i510400 8GB/1000GB HDD/Window 10 professional brand) INSPECTION BY CONSIGNEE.
to be submitted by OEM in Annexure form. INSPECTION BY CONSIGNEE
7 Description:- Konark Exhaust fan 300mm or Similar. INSPECTION BY CONSIGNEE
comprising of Kirloskar and similar , make engine With Crompton Greeves and similar make alternator. INSPECTION BY CONSIGNEE 1468796.9
8 Description:- Supply and Commissioning of SMPS based Integrated Power Supply System spares and tools as per RDSO specification No. RDSO/SPN/165/2023 Version 4.0 amendment 1 or latest amendment applicable as on date of tender notice and as per WCR drg. No. WCR/N-HQ/IPS/6
as per battery AH 2v/300AH capacity (VRLA Battery) is to be supplied by tenderer, 12 core x 1.5 Sq. mm signaling cable for connecting IPS to status monitoring panel will be supplied by railway free of cost. Supply and commissioning of IPS should be as per RDSO letter no STS/E/IPS/General 03.04.2008. Note:-The firm will supply oneadditional SMR of rating110V, 20A in addition to 6 SMRs that they will supply as per drawing of IPS in this purchase. INSPECTION BY RDSO
Description:- "Supply of powder coated Relay Rack Assembly complete with scaffolding, fixtures and accessories including MS Bars / relay frames for fixing of relay plug boards, string rods, J-bolts, insulators, fuse strips with bracket, 11 Way Bus Bars with cover and mounting brackets, runway for
Rly. Typical part and Rack arrangement as per Sketch Nos Sk-727 and Rack plan as approved by Engineer incharge. Rack should be made of first class steel powder coated painting and rack manufacturer's certificate should be submitted. All runway for cables / wires shall be provided with PVC sleeve of proper size as per Annexure .INSPECTION BY CONSIGNEE"
11 DY CSTE-C-JBP-S AND T/WEST CENTRAL RLY 11 Description:- Supply of powder coated Main Cable Termination rack complete with scaffolding, fixtures & accessories including square bars for mounting 8- way terminal / WAGO - make terminal blocks, ladders, string rods, frame, base assembly, insulators, J bolt, nut/bolts & fasteners, etc. Siemens' type & as per extant practice on W. C. Rly. Typical part list and rack arrangement shall be as per sketch SK-727. Rack should be made of first class steel powder coated painting and rack manufacturer's certificate should be submitted. All runway for cables / wires shall be provied with PVC sleeve of proper size as per annexure. INSPECTION BY RITES
Description:- Supply of Sealed Maintenance free VRLA Battery set of 60 cells(Stackable),in
cell of 2V/300AH capacity, fully charged, confirming to RDSOSpecn.no.:IRS:S:93/96(A)with latest amendment. INSPECTION BY RDSO
Description:- Supply of SEALED MAINTENANCE FREE VRLABATTERY SET OF 60 CELLS 2V/200 AH
FOR SMPS BASED INTEGRATED POWER SUPPLY(IPS)SYSTEM, CONFORMINGTO RDSO SPECIFICATIONNO. IRS : S-93/96(A)AMENDMENT NO.1COMPLETE WITHCONNECTING LINKS ANDSUITABLY NUMBERED INSTACKABLE RACKS ALONGWITH USER MANUALS.INSPECTION BY RDSO
Description:- Supply of Relay, AC Immune, Plug-in type, Style QNA1, 24 V DC, 8F-8B/12F-4B
conforming to BRS:931A, IRS: , S- 34, S- 23,S- 60-78 or latest Interlocking pincode ABDGH/ABDFH. The relays of various contact configuration shall be 8F/8B (90% Qty), 12F/4B (10% Qty). . INSPECTION BY RDSO
Relay, Style QL1, 24 V DC, 11F-4B Contact, Code ABDEG Spec: BRS:935A ; IRS S 34 ; IRS S 23, STR: STR SIQ 0420 ver 1.2, INSPECTED BY RDSO
Description:- "Supply of QNA1K (AC immunized) Relay 24V DC 1000 Ohm , ACI Style- QNA1K, 6F-
and connectors confirming to IRS: S@ 45"44@ S- 23 & BRS: 931A (as applicable), Interlocking pincode CDEKY/CDEKY . INSPECTION BY RDSO."
Description:- Supply of Key Lock Relay AC immunized as per RDSO/SPN/219/2016 Ver 1.0 with Amendment-1 with different ward combinations ( Two extra set of same ward plates for Point
equivalent(wards to be supplied with the consultation of Engineer in charge of work as per requirement of site and no additional cost will be paid for extra wards) The ward combination shall be A,B,C,D,E,F,G-Z). Before supply the Relay necessary approval to be taken from this office. INSPECTION BY RDSO.
Description:- "Supply of Relay, AC Immune, plug-in-type, Style QNNA1 twin DC neutral line relay ,
carbon complete with plug board & retaining clip and connectors confirming to BRS 960,IRS:S60,S34 & IRS S23.Interlocking pincode ACDHJ. INSPECTION BY RDSO."
equivalent with timer range up to 120 seconds. INSPECTION BY RDSO.
Description:- "Supply of Relay, AC Immune, plug-in-type, Style QSPA1, DC Neutral line, slow to pick
complete with plug board, retaining clip & connectors conforming to BRS:933A,IRS:S60,S 34 & S 23. Interlocking pincode ABDEJ. INSPECTION BY RDSO." Please see Item Breakup for details. 3592636.00 AT Par 3592636.00
and measurement suitable for at least 2.5 mm2 conductor 1452086.1
2 DY CSTE-C-JBP-S AND T/WEST CENTRAL RLY Description:- Supply and Transportationof Single Line Block Provingby Axle Counter (BPAC)using
latest.Each set consist offollowing: (i) Universal FailSafe Block interface UFSBI)with complete accessoriesas per Specification No.IRS:S-104/2012 (Ver.0) orlatest - 2 sets. (ii) BlockPanel complete as perRDSO Drawing No.RDSO/S-32019 - 2 sets.(iii) Relay Rack withLocking and sealingarrangement duly wired asper Drawing No. RDSO/S-32020 including all Relay swiring and supply of all type of Relays - 2 sets. ORElectronic Block logicModules (EBLM) Type -DESBPACCBLM v1 with 5Relays as - BIPR1, BIPR2,TGTR, TCFR & ASCR - 04Sets (iv) Block Telephonewith accessories as perSpecification NoRDSO/SPN/191/2005 orlatest, with all type oflighting protection and in-built automatic mediachangeover withVoice/E1/Dark Fibre Port -2 sets. (v) Short of indoorcables, ladder etc. Theactual requirement ofcommunication modemshall be advised byEngineer-in-charge of thesite. (Inspection by RDSO)
Description:- Supply, installation, testing and commissioning of Single Section Digital Axle Counter
Reversal type)It includes supply of dummy wheel and marking zig for 60 KG rail. INSPECTION BY RDSO. ( Warranty Period : Upto 30 months from the date of supply)
Description:- Supply of Data logger for monitoring status of important relay, complete with processor module tomonitor 1024 digital and 48 anlog inputs as per RDSO spec. IRS -S-99/2006 with
failureanalysis and modem card for monitoring DATALOGGER , complete data logger and processormodule ( as per annexure C) shall be placed inprecedent rack of suitable siize to be supplied bythe contractor. INSPECTION BY RDSO
logger net worksas per RDSO guidelines Nos, STS/E/Datalogger/vol. XX dated 12.09.2011) from station totest room at JBP. INSPECTION BY CONSIGNEE.
for data logger. INSPECTION BY CONSIGNEE. Please see Item Breakup for details. 2946480.87 AT Par 2946480.87 Description:- Supply, installation, testing and commissioning ofUL/FM/VDS/LPCB approed
panel with display, in bultcharging facilities and provision of GSMmodulesuitable to send SMS to configured moblieno. Thepanel should be equipped with nos. ofloopsand provision of expandability as per RDSOspecification no RDSO/SPN/217/2025 ver 3.1 or latest
for aspiration detection Inspection by Consignee(1Number = 3 Mts). INSPECTION BY RITES. supply portion.
29 Description:- Supply of PVC conduit Pipe having Diameter 25mm INSPECTION BY CONSIGNEE
Main unit of Automatic Fire Detection and Alarm System. INSPECTION BY CONSIGNEE supply portion"
Description:- Supply, Installation, Testing & Commissioning of Analogue addressable type input/output Modules with inbuilt fault isolator or alternate arrangement which shall isolate the
output. The module should have visual indication for its operation, PF contact (NO/NC) Approval UL/LPCB/VDS listed and shall comply to RDSO Specification no. RDSO/SPN/217/2021 Ver.3.0 or latest. INSPECTION BY RDSO
Description:- "Fuse auto changeover system for used in Railway Signaling system as per
nos. of external Non Deteriorating type or 'G' type fuse from 0.6 Amp to 4 Amp capacities which are in signaling circuits. System shall type 8 cards with monitoring arragngement of 4 fuses in one card. INSPECTION BY RDSO"
Description:- "Fuse auto changeover system for used in Railway Signaling system as per RDSO/SPN/209/2012 rev.1 with latest amendments. One Autometic changeover unit comprise 24
in signaling circuits. System shall type 6 cards with monitoring arragngement of 4 fuses in one card. INSPECTION BY RDSO" DY CSTE-C-JBP-S AND T/WEST CENTRAL RLY
INSPECTION BY CONSIGNEE
Description:- Supply of Visitor Chair of steel frame of 30 mm width,chrome polish having
resolving type and the arm of chair should have cover for suitable length Make GEE-KEN Premier Royal Kons, Harlison or best for brands INSPECTION BY CONSIGNEE
top aapprox. Height of the stool 18" inches approx. with duly powder coated, MAKE-Godrej ,GEE-KEN or similar .INSPECTION BY CONSIGNEE
Description:- Supply of Revolving chair for officer with cushioned seat and medium height back
height etc. The revolving chair should have 5 Nos. of nylon wheels. make: GEE-KEN, Premier, Royal Koas, Harlison or similar. INSPECTION BY CONSIGNEE
make five compartment, three way locking device, made of CRCA sheet,, powder coated AH-101 MAKE-Godrej ,GEE-KEN or similar .INSPECTION BY CONSIGNEE
3.3 KV to 11 KV (Class B) confirming to IS-15652-2006. INSPECTION BY CONSIGNEE.
600:470. INSPECTION BY CONSIGNEE.
size of 1.22 x1.22 Mtr as per spec. No IS 2036 of 1974 . INSPECTION BY RITES.
6/81 with latest amendments. INSPECTION BY CONSIGNEE.
6/81 with latest amendments. INSPECTION BY CONSIGNEE.
Specification IS:1239 Pt-1/1990). INSPECTION BY CONSIGNEE.
Description:- Supply of Cast Iron Main signal surface base 140mm as per spec No IRS S 10 and Drg
long as per RDSO Drg. No. SA-23156. & signal front staging complete assembly for CLS unit as per Drg. No RST/11413 & signal back staging as per extent W. C. Rly practice. INSPECTION BY RITES.
CLS signal transformer ,MECR & Lamp holder,suitable for LED signal confirming to specification IRS S 26/64. INSPECTION BY RITES.
CLS signal transformer ,MECR & Lamp holder,suitable for LED signal confirming to specification IRS S 26/64. INSPECTION BY RITES.
complete alongwith its base & clamping arrangement. INSPECTION BY CONSIGNEE.
INSPECTION BY CONSIGNEE.
INSPECTION BY CONSIGNEE.
51 DY CSTE-C-JBP-S AND T/WEST CENTRAL RLY 51 Description:- Supply of Offset bracket 3-1/2" for shunt signal unit. INSPECTION BY CONSIGNEE
per IRS:S-66/84 amendment -1 or latest INSPECTION BY CONSIGNEE.
per IRS:S-66/84 amendment -1 or latest INSPECTION BY CONSIGNEE.
similar INSPECTED BY CONSIGNEE"
INSPECTION BY CONSIGNEE.
23476-77 as applicable. With Clamp, nut & bolt etc. INSPECTION BY CONSIGNEE.
CSTE/C/BPL/003. It also includes supply of M S Channel, Nut & Bolt etc as per drg. INSPECTION BY CONSIGNEE.
along with terminal blocks. The TLJB should be BLACK in colour. INSPECTION BY CONSIGNEE.
1.0 or lates.Charger shall be of 10 A output capacity .Charger shall be suitable for charging 80 AH battery and no of cells 2,3,4. INSPECTION BY RDSO.
SA 20161- 66/M (Adv) with latest amendments (with Phenolic moulded base). INSPECTION BY RDSO.
INSPECTION BY RDSO
Description:- Supply of low maintenance Lead Acid Secondary Cells 2V/80 AH as per spec. IRS: S-
floats, lead coated inter cell connectors, lead coated brass nut bolts & washers in dry and uncharged condition. INSPECTION BY RDSO
Description:- "Supply of Relay, AC immune, Plug- in type, style QTA2 relay, DC Neutral track, Relay
conforming to BRS: 939A, BRS: 966 (Appendix F2) IRS: S- 34 & IRS: S- 23 as applicable.Interlocking pincode FGHKX. INSPECTION BY RDSO."
Description:- Supply of Relay,AC immune, plug-in-type, Style QBAT DC biased track, 2F-2B Contact,
board, retaining clip & connectors conforming to RDSO/SPN/84-88,IRS S 34 & IRS S23 Interlocking pincode ABEJX. INSPECTION BY RDSO.
and Spec. No. IRS-S-75/2006 with latest ammendment. Fuse block shall be suitable for round head type fuses. INSPECTION BY RDSO.
(40%) / 4A( qty. 20%) /6A(qty. 10%)/10 A(qty 10%) 16 Amp (qty. 20%) in equal proportion round head type as per specification No. IRS/S/78/92 with latest amendment. INSPECTION BY RDSO. Please see Item Breakup for details. 56731.40 AT Par 56731.40 68 DY CSTE-C-JBP-S AND T/WEST CENTRAL RLY 68 Description:- Supply of Resettable fuse, type Polymeric Positive Temperature Coefficient (PPTC) fuse of make Little fuse /Fuzetec /Tyco/Bourn/Raychem, suitable fuses with trip current shall be supplied as per requirement given below. INSPECTION BY CONSIGNEE.
as per spec No IS 694/1990 with latest amendment. INSPECTION BY CONSIGNEE.
as per spec No IS 694/1990 with latest amendment. INSPECTION BY CONSIGNEE.
as per spec No IS 694/1990 with latest amendment. INSPECTION BY CONSIGNEE.
as per spec No IS 694/1990 with latest amendment. INSPECTION BY CONSIGNEE.
core shall be in six colour ,Blue ,Red, Grey,Green ,Brown and Black confirming to Spec No IRS-S- 76/89 Amendment-3 or latest. INSPECTION BY RDSO.
core shall be in four colour, Yellow, White, Pink and Violet confirming to Spec No IRS-S-76/89 Amendment-3 or latest. INSPECTION BY RDSO.
shall be in six colour ,Blue ,Red, Grey, Green ,Brown and Black confirming to Spec No IRS-S-76/89 Amendment-3 or latest. INSPECTION BY RDSO.
INSPECTION BY CONSIGNEE
site incharge/consignee. INSPECTION BY CONSIGNEE.
RDSO/SPN/199/2025 Rev.1.2or latest. Suitable for existing CLS housing unit . RED Aspect. INSPECTION BY RDSO.
RDSO/SPN/199/2025 Rev.1.2 or latest. Suitable for existing CLS housing unit . YELLOW Aspect. INSPECTION BY RDSO.
RDSO/SPN/199/2025Rev.1.2 or latest. Suitable for existing CLS housing unit. GREEN Aspect. INSPECTION BY RDSO.
LED ECR as per RDSO Spec RDSO/SPN/153/2023 REV 5.0 with Latest ver. INSPECTION BY RDSO.
LED ECR as per RDSO Spec RDSO/SPN/153/2023 REV 5.0 with Latest ver. INSPECTION BY RDSO.
compatable with AC LED ECR as per RDSO Spec RDSO/SPN/153/2023 REV 5.0 with Latest ver. INSPECTION BY RDSO
Description:- Supply of electrical point machine IRS make 110V DC operation(AC immunity 160V)
detector(Rotary locking) as specification no.IRS S 24-2025 REV 3.0 (Or latest), requirement of point machine is 143 mm throw only as per RDSO drg. no. RDSO/S-10800. INSPECTION BY RDSO.
DY CSTE-C-JBP-S AND T/WEST CENTRAL RLY Description:- Supply of Ground connections, complete set suitable for IRS Make point Machine for
RDSO/S 3361/ 62/63 with latest amendment. This includes supply of Acetyl bushes as per site requirement. (Ground connections for 52/60 Kgs. Rails as per RDSO drg. No. S-3362). INSPECTION BY CONSIGNEE.
for cable entry in point machines. GI pipe shall be as per spec IS:1239 (Pt. I) - 2004 or latest. INSPECTION BY CONSIGNEE."
TEKNIC/SIEMENS make push buttons, 8-way terminal strips / Wago Terminal, string rod, etc. as per Drawing No.RST.C.111A. INSPECTION BY CONSIGNEE.
RDSO drg No T-10367, T-10368, T-10371 as applicable and to the spec IRS S 23 & 40/84 with latest amendment. INSPECTION BY CONSIGNEE.
10368, T-10371Alt2, T-15083/88/Alt2 & T-11690/Alt2 and to the spec IRS S 23 & 40 with latest amendments as applicable. INSPECTION BY CONSIGNEE.
consisting of one insulating plate & Insulating bush 3 Nos. Supplied As per RDSO Specn & Drg No RST-10692. INSPECTION BY CONSIGNEE.
Description:- Supply of Electric Point Machine (Rotary locking Type) , 110VDC operation (AC
arrangement suitable or 220mm throw for thick web switches comple with insulation. as per IRS S 24-2025 REV 3.0 (Or latest) INSPECTION BY RDSO.
complete with insulation as per annexure. INSPECTION BY RDSO
Description:- "Supply of Thermo-shrinkable jointing kit size 75/15-850 suitable for derivation joint
rev 3 with latest amendments This item includes supply of one no of isolation transformer (with impedance ratio of 470:600) per joint. INSPECTION BY RDSO."
Description:- Supply of Electrically lifting barrier assembly each consisting of 2 electrically operated lifting barriers, 2 Pedestals, 2 Nos. of 8 band circuit controller with limit switch, hand cranks, 2 electric motors 110 VAC without centrifugal switch, 2 booms as per RDSO DRG. No.
weights and 2 Nos. of boom support for resting boom & boom resting assembly along with Gate Control Panel, indication panel on sheet metal fabricated box with switches and buttons to operated the gate as per RDSO specification no. RDSO/SPN/208/2012 version 2.0 or latest, limit switches instead of wiping type contact. Crank handle arrangement will be as per Rly. Requirement. The movement of the boom over 90 degrees to be restricted mechanically. INSPECTION BY RDSO.
(Rev.2) with latest amendments and RDSO Drg. No. SA-23741A. INSPECTION BY RDSO. Please see Item Breakup for details. 6247342.58 AT Par 6247342.58
S 30/64 & RDSO Drg. No. SA 3376/M with latest amendments. INSPECTION BY RITES."
Description:- Supply of Double Walled Corrugated pipe fire resistant and anti-rodent made up of
specification no. RDSO/SPN/204/ 2011 with latest amendment along with one coupler per every 6 meters. INSPECTION BY RITES.
12.5Kg per Meter as per spec. No. IS 1239 PT. 1/1990 INSPECTION BY CONSIGNEE.
99 DY CSTE-C-JBP-S AND T/WEST CENTRAL RLY 99 Description:- Supply of earth electrode assembly as per Drg. No. CR/SK-753. INSPECTION BY CONSIGNEE.
communication, model: Sidekick plus 1155-5001 or Equivalent INSPECTION BY RITES
Description:- "Supply of cable route locator/tracer set suitable for detecting underground
modes and depth range.3M- 10M. Make Stanly/ST LOC 10 GPS or equivalent. As per specification attached in tender document. INSPECTION BY CONSIGNEE."
or with latest Amendments. INSPECTION BY CONSIGNEE.
Description:- Supply of automatic media changeover for UFSBI working on redundant channels for
232,V24 ports of integrated multiplexer .it also includes supply of modem suitable for automatic media changeover. INSPECTION BY CONSIGNEE.
Description:- Integrated Access Multiplexer IU height, 19" rack mountable with 4DTE interfaces &1
data interface RS-232,V.24 of 8 ports supporting baud rates as per technical specifications in the annexure N, 1 slot free,unit to support both AC/DC power supply,cable 50 pin SCSI connector 1 no included, MROTEK Model MAPLE-4C or equivalent. INSPECTION BY CONSIGNEE. Please see Item Breakup for details. 1572362.48 AT Par 1572362.48 Description:- Supply & installation of maintenance free earth consisting as per RDSO specification No. RDSO/SPN/197 (version 3.1 or latest) or consisting of single earth pit which includes supply of 35 mm²/16 mm²/10 mm² multistrand single core PVC insulated copper cable as per IS 694 for connecting main earth electrode to MEEB in the equipment room in duplicate as per manufacturers recommendations and as per RDSO specifications as follow: (1) Copper bonded steel electrode of 3.0 meters long, 17 mm diameter with copper bonding thickness of minimum 250 microns and UL listed and marked: 1 No. (2) Earth enhancement compound of RDSO approved brand supplied in sealed bag of minimum 10 KG: 3 Nos. (3) Copper strip of 200mm X 25 mm X 6 mm to terminate earth rod: 1 No. (4) Copper strip of 300mm X 25 mm X 6 mm (MEEB): 1 No. (5) Copper strip of 200mm X 25 mm X 6 mm (MEEB): 1 No. Installation of maintenance free earth includes:Digging/auguring/boring of single earth pit of 100 mm to 125 mmdiameter to the depth of approximately 2.8 meters. Insertion
hammer where the neutral soil is assumed. Filling of earth pit with earth enhancement compound (EEC) in slurry form and back filling. Carrying out exothermic weld connection of single earth electrode to a copper tape of 200 mm X 25 mm X 600 mm. Carrying out exothermal weld connection on the copper tape of 200 mm X 25 mm X 6 mm on earth electrode for connecting two 35 mm² cable for redundancy. The exothermal welding material for bonding the earth system shall be procured from RDSO approved firms which includes graphite moulds, clamps, weld metal powder.
painted in black and date of testing and average earth resistance value shall be written. SUPPLY PORTION INSPECTION BY CONSIGNEE of single earth pit which includes supply of 35 mm²/16 mm²/10 mm² multistrand single core PVC insulated copper cable as per IS 694 for connecting main earth electrode to MEEB in the equipment room in duplicate as per manufacturers recommendations and as per RDSO specifications as follow: SUPPLY PORTION INSPECTION BY RDSO
Description:- Design, Manufacturing and supply of prewired DC- DC converter panel Suitable for 12
fixing arrangemnet for base floor mounting , the item also include prewired wiring arrangemnet suitable for convertor units and suitable voltage(24V/60V/110V ) terminals. INSPECTION BY CONSIGNEE.
110V AC and 3 channel card for monitoring 24 V DC and one for 110V DC as per RDSO Spec No RDSO/SPN/256/2002 with latest rrangemen. INSPECTION BY RDSO.
Description:- "Supply of fuse alarm system for monitoring 110 Volt,10 Amp fuse with automatic
Each module of fuse alarm should be compactable to be mounted on existing Relay rack with out any alteration. INSPECTION BY RDSO. Per Unit =Per Fuse" Please see Item Breakup for details. 904789.08 AT Par 904789.08 109 DY CSTE-C-JBP-S AND T/WEST CENTRAL RLY
Description:- "LENOVO,DELL, HP and similar(All-in-One 24,13th Gen Intel Core i7-1355U,23.8inch (61 cm) ,FHD,Anti-Glare,16 GB DDR4,512GB SSD, 710 White Wireless Keyboard and Mouse Combo,Windows 11,Shell White, 5.53kg,24- cr0037in along with UPS ZEBRONICS Zeb-U725 600VA UPS for Desktop/PC/Computers (not for Routers) with Automatic Voltage Regulation,
Centimeters Voltage230 Volts ColourBlack About this item it is generator compatible. Output voltage regulation (Batt.mode):+/- 10% Protects from overloading. Input voltage rage : 140-300VAC. Surge Protection : Yes micro controller based sleep mode charging LED indicator Capacity 600VA Transfer time Typics4-8 ms Recharge time 6 hours to 90% after complete discharge The ups is not compatible with router INSPECTION BY CONSIGNEE "
Description:- "HP, EPSON, CANON,Brother ( MFC-T4500DW) and similar All-in-One Colour Inktank Refill System Printer with Wi-Fi and Auto Duplex Printing,Black BrandBrother Connectivity TechnologyWi-Fi Printing TechnologyInkjet Special FeatureAuto Duplex ColourBlack Model NameMFC-T4500DW Printer OutputColour Maximum Print Speed (Colour)27 ppm Max Print speed Monochrome35 ppm Item Weight20.5 Kilograms See less About this item Printer Type - Ink Tank ;
Wi-Fi Direct Genuine Ink Bottles - BTD60BK, BT5000 C, M, Y; Page Yield - 13000 pages (Black), C, M, Y - 5000 pages each (Colour) Ink Color : Black, Cyan, Magenta and Yellow A4, Letter, Legal, Mexico Legal, India Legal, Folio, Executive, A6, Envelopes (C5, Com-10, DL, Monarch), Photo (4"" x 6"")/(10 x
pages (Black), C, M, Y - 5000 pages each (Colour) 1 year On-Site warranty; Operating Temperature -
IS 694 INSPECTION BY CONSIGNEE."
voltage of 135V at 100A and peak single pulse(8/20us) rating of 6.5KA. EPCOS, Bourns or Littelfuse make. INSPECTION BY CONSIGNEE
clamping voltage of 250V at 100A and peak single pulse(8/20us) rating of 6.5KA. EPCOS, Bourns or Littelfuse make. INSPECTION BY CONSIGNEE"
clamping voltage of 300V at 100A and peak single pulse(8/20us) rating of 6.5KA. EPCOS, Bourns or Littelfuse make. Inspection by consignee"
117 Description:- MOV S10k25
118 Description:- MOV S20K230
at 20A and peak single pulse(8/20us) rating of 2KA. EPCOS, Bourns or Littelfuse make. (S20K25:24VDC)
at 20A and peak single pulse(8/20us) rating of 2KA. EPCOS, Bourns or Littelfuse make. (S20K40:48VDC)
at 20A and peak single pulse(8/20us) rating of 2KA. EPCOS, Bourns or Littelfuse make. (S20K11:12VDC)"
Description:- "Supply of MOV B72220S 251K101 (MOV S20K250) rating 250 Volts AC of 20mm dia , 122 make- EPCOS or similar. Approval of material sample should be taken from consignee before bulk supply. Inspected by consignee. Make/Brand-EPCOS DY CSTE-C-JBP-S AND T/WEST CENTRAL RLY
make- EPCOS or similar. Approval of material sample should be taken from consignee before bulk supply. This item is not available in GeM. Make/Brand-EPCOS/TDK . INSPECTION BY CONSIGNEE
Description:- "Supply of MOV 20mm dia for 25V AC/31V DC supply with maximum clamping
(S20K25:24VDC).Approval of sample material should be taken from consignee before bulk supply. This item is not available in Gem . Make/Brand-EPCOS INSPECTION BY CONSIGNEE
Approval of sample material should be taken from consignee before bulk supply. This item is not available in Gem . Make/Brand-EPCOS make. INSPECTION BY CONSIGNEE
Description:- TVS Diode, 1500W peak pulse capability at 10/1000 micro second, Bi-directional, reserve standoff voltage=8.55V, maximum clamping voltage=14.5V at 104.8A, maximum reverse leakage current of 10 micro-Amp at 8.55V of repute make:Across data communication ports of
equipment at originating & terminating side of cable. Across TX/RX of E1 terminals of equipment wherever cable connecting the equipment length is more than 1m. Across RX input terminals of DAC (if functional earth is there then RX1-E-RX2 & RX1-RX-2( protection).Any other equipment requiring protection against transients with wrong voltage less than 5.5V AC/8.5 DC and cable length is more than 1m.
Description:- Aluminium boom fabricated from 3 mm(Ist section) 2.5 mm (II nd section) & 1.9 mm
bends in the channels.Two such channels then joined together with baten plates by rivetting to form a tapering box sketch.Total boom length 32 ft.long in 4 sections of 8 ft each.Sections to be joined by nuts & bolts for easy replacement. "
spec. IRS -S-99/2006 amendment-3 or latest amendment. INSPECTED BY RDSO "
cosignee. INSPECTED BY CONSIGNEE
Description:- "Supply of Relay Ac Immune, Plug in type, Style QBCA-1 , Dc Biased Point Contactor,
with Plug Board, Retaining Clips and Connectors, Confoming to Brs 943, Irs 2 34 and Irs S 23. INSPECTED BY RDSO
131 Description:- "Supply of relay universal LED ECR, QECX 61 4F/4B. INSPECTED BY RDSO
with base plate and shall be suitable for working in series with 110V AC, LED based signal lighting unit as per STS/E/Relays/AC Lit LED Signal/09-2002 with Amdt. No. 1. INSPECTED BY RDSO
consolidating and dressing complete S.No. Item Item Qty Qty Unit Unit Rate Basic Value Escl.(%) Amount Bidding Code Unit Schedule () B -Execution 126729314.73
DY CSTE-C-JBP-S AND T/WEST CENTRAL RLY
architecture as supplied under item no 1 of Sch A . It includes transportation of material from depot of consignee to the site.Erection and grouting of EI Relay Racks, fixing and wiring of all interfacing relays (Vital and Non vital) installation and wiring of Microprocessor equipments, interface equipments, power supply equipments, and all other associated accessories to make complete EI system to be functional. NOTE: (i)Technical requirements are attached herewith. (ii)Contractor has to arrange simulator /simulation testing panel for testing and commissioning by selection table and square sheet for each Signalling function. (iii) Installation, Wiring, testing, and commissioning of EI system will be done by OEM after following all the guidelines/directives issued by RDSO from time to time. 2645681.0
6 Description:- Modification/Alteration/augmentationof existing electronic interlocking(EI)system as per RDSO SPN No RDSO/SPN/192/2005 as perapproved signalling plans andselection table/Locking table ofstations (for phased doubling,LCremoval etc.) technical specifications& special conditions of
includes suppliesnecessary for earthing themodified/altered/augmented EIthose needed for re-wiring externaldata logger and fuse alarm system.This item also includes preparationof Selection Table,LockingTable,Control Panel and Routesection plan,wiring diagram andother diagrams(other technicaldocuments if any) based onSignalling plan supplied by railway.(completion Documents as perspecial condition of contract) thisitem for Gondawali station. EI=Per EI
Indication/Alarm panel system. It shall consist of 200 LEDs of 10mm size fabricated in a box of 15mm waterproof ply
Description:- Supply, Installation, Wiring, testing, and commissioning of embedded fanless PC
2.0 with latest amendments and RDSO TAN No. STS/E/TAN/3007 version 1 dated 02.11.2012 and latest TAN.The display size of VDU shall be 55 inch. as per latest and guidelines NOTE: Technical requirements are attached herewith. INSPECTION BY CONSIGNEE.
Description:- Supply, of embedded fanless PC based VDU Control terminal/maintenac terminal as
STS/E/TAN/3007 version 1 dated 02.11.2012.The display size of VDU shall be 55 inch. as per latest and guidelines NOTE: Technical requirements are attached herewith. INSPECTION BY CONSIGNEE.
gravity of Battery Graded acid with mounting stand in location Boxes. Consignee inspection under manufacturer certificate. INSPECTED BY CONSIGNEE
inch display on each side, with two numbers of block counter table . Table is as per RVNL drawing No RVNL/S&T/SC/14/A/2018 attached in annexure. (Inspection by consignee)"
Description:- Earthing of EI Parimetric ring earth equipments, for covering SM office, Relay/Room,
per specifications recommended by manufacturer & latest RDSO guideline for item No 1 & 2 for covering of complete S & T service building as per instruction of site engineer. INSPECTION BY CONSIGNEE.
Maintenace, Repair and Troubleshooting of EI system complete including supply of hard/soft copies of course module for each trainee.
including supply of hard/soft copies of course module for each trainee.
Description:- "Installation of Cable Termination rack/Relay Racks Assembly complete including wall
work shall be done as per approved plan, extant practice on W. C. Railways & the instruction of Rly. engineer at site(.All fixing material to be supplied by contractor) as per typical rack arrangement WCR DRG No S&T EQPT.BLDG/2013/Pt.1/4 The sting rod shall be fixed on phenolic laminated sheet."
DY CSTE-C-JBP-S AND T/WEST CENTRAL RLY Description:- Termination of cable cores on ARA terminal/8- way/Wago terminals in the cable
peeling off insulation, dressing of cable,wiring tree with contractor lacing & threading material, providing required insulating material ferrules, sleeves etc.This includes soldering of armour tree/ring of cables and connecting to Earth bus bar, The work shall be done as per approved plan, extent practice on WCR and instructions of Rly engineer at site.
(BPAC) using BlockPanel and UFSBI completewith all accessories as perSpecification No. IRS:S- 105/2012 (Ver.0) or latest.
Description:- Installation, Wiring and testing of Integrated Power Supply System including Connection to change- over unit. This includes transportation, loading and unloading of IPS system complete and batteries from depot to the site of installation. The all supplies shall be wired right from IPS to power supply distribution board / rack with contractor's own wiring materials except 25sq mm wire (which is included in supply of IPS). The wiring in redundancy (including CT rack to power
flexible copper wire of 6 Sq mm, 10 Sq mm, 16 Sq mm, 25 sq mm etc. as per IS:694 of 1990 or latest as per RDSO recommendation of IPS installation. This also includes instaliation of CT rack in IPS Room,fixing ofARA/Wago terminals. with connections suitable for 32 A. The 25 sq mm wire shall be used for connecting Batteries from IPS, 16 sq. mm power cable is to be used for wiring of 110V DC, 110V AC & 60V DC (internal) and for balance power supply 6 Sq mm, 10 sq mm power cable is to be used. All types of PVC wires, connectors, wiring material, ladders, DWC pipes etc as per site requirement are to be arranged by contractor as per instructions of railway engineer at site.
Description:- Fabrication, supply & screen printing of SWRD/RSP/Laminated board/System
1200x600x3mm as per instruction of site engineer.Proportion payment will be made if size of board get increased or decreased. (INSPECTION BY CONSIGNEE)
along with accessories with contractors own materials. This includes programming of data logger for fault diagnostic in suitable structured language in consultation with railway.
Description:- "Alteration in existing data logger, wiring, testing, and commissioning of Data logger
data logger for fault diagnostic in suitable structured language in consultation with Rly. .also includes loading of Networking Software and networking of data logger with Divisional HQ. The requisite communication cable/channel for networking will be arranged by Railway. "
Description:- """Lettering & Numbering of detail and description writing of particulars of terminations & equipments on relay rack, relays, cable termination rack, battery & power equipments, IPS, operating panel, axle counter etc constituting entire system with contractor's own
used). Also, Ferrules with Printed letters/PVC sleeve with printed details of cores shall also be provided on each cable conductor, Supply by contractor. Supply and fixing of teflon strips 3mm thick and 25 mm wide for each row of relays and cable terminations. The work shall be done as per RB's instructions issued vide letter no. 2023/Sig/17-Sig Equip Maintenance/Part dated 06.11.2023 and extant practice on W.C.Rly & instruction of Rly engineer at site. Unit-per station"""
Description:- Fixing of Q series relay base plate/ Metal to Metal relay mini group and major group base plates, laying, lacing, dressing & packeting of 60/40/24 core PVC indoor cable and termination of 60/40/24 core cable on tag block & base plates & its soldering. Wiring of circuits to be done as per the approved diagram based on relay interlocking system using metal to metal/metal to carbon type relays and soldering after testing. This also includes fuse wiring, function wiring (Including
supply distribution board / rack to relay racks and cable termination racks with provision of wiring of ring connection with the help of contractors own single core flexible multistrand copper wire of 16 sq mm and 10 sq mm as per RDSO specification no. IRS-S 76/89 with latest amendment. 16 sq mm wire for All 110V DC, 110V AC & 60V DC internal supply and 10 sq mm wire for balance supply is to be used) Materials required like jumper wire of 0.6 mm, 1.0 mm, 16/0.02 multistrand flexible etc, resin core, solder wire, lacing thread, adhesive tapes Per Unit = Per Rack
DY CSTE-C-JBP-S AND T/WEST CENTRAL RLY
system, making the panel through, functional test as per control table with contractor's own mock panel, break test if applicable to be done in presence of Rly. Engineers. This will include wiring alterations required if any at that stage, preparation and submission of wire count detail register etc. The work shall be done as per extant practice on W.C.Rly & the instruction of Rly engineer at site. All type of resistances, capacitors etc required for commissioning have to be provided by the contractor free of cost. Per Unit = Per Rack
board,fuse indication system, ELD, KLCR box and emargency key box etc.This includes laying & termination of of cable,if any from panel room to relay room in GI/HDPE pipe.
Description:- Preparation of Cable Route Plan, Cable Coreage Plan, Location Particulars, Cable Meggering Report, Earth resistance particulars, Track Circuit jumper/bonding Diagram, Traction Bonding diagram, and any other drawing on Auto- CAD in A2/A3/A4, etc. size (as per instruction of engineer incharge). The basic rough sheets shall be prepared by Site Engineer of contractor in
the contractor shall prepare the same in Auto- CAD in A2/A3/A4, etc. size (as per instruction of engineer incharge). Initially contractor shall supply 2 sets of documents complete for approval of Railways. Railways will return one set to the contractor duly approved with alterations/ corrections if any. The contractor shall incorporate Railways alterations/corrections in the tracings without any deviation and submit all tracings complete in all respects alongwith its soft copies and 4 sets of final completion drawings properly bound in steel clip jaw with cushion cover to railways.
Description:- Excavation, casting and plastering (above ground level) of main signal foundation as
anchor bolts of standard size. The hole for cable entry should be kept as per site requirement and instruction of Rly engineer at site. The required scaffolding Ferma etc for casting of foundation will have to be brought by the contractor at his own cost.
Description:- Excavation, casting and plastering (above ground level) of Shunt Signal foundation as
Anchor Bolts of Standard Size. The hole for cable entry should be kept as per site requirement and instruction of Rly engineer at site. The required scaffolding, Ferma etc for casting of foundation will have to be brought by the Contractor at his own cost.
Description:- Erection of CLS Post with Surface base and signal unit on top or on OFF set Bracket, fixing of front and back staging, ladder and guards, signal name plates and A/AG/C/P/G marker
materials. This also includes erection of auxiliary signals like calling on, shunt signal if any. The work shall be done as per instructions of Rly engineer at site. Wooden white cross-arms (1000x100 mm) to be provided by the contractor till the signals are commissioned with contractor's own material.
Description:- Erection of shunt signal with Surface Base, Post, Signal unit and fixing of No. plates.
(1000x100 mm) to be provided by the contractor till the signals are commissioned with contractor's own material.
shall be done as per the instruction of Rly engineer at site.
Description:- "Termination of tail cable on main & auxiliary signal units and wiring with contractor
(50/0.25) conforming to IS-694:1990 (as per aspect colour) and lugs etc. will be supplied by the contractor. This includes insertion of tail cables from ground to signal unit. The work shall be done as per instruction of Rly engineer at site."
Description:- "Termination of tail cable on Shunt signal units and wiring with contractor own wiring material, fixing of LED signal unit etc. Flexible Single core copper wire 2.5 sq.mm (50/0.25)
contractor. This includes insertion of tail cables from ground to signal unit. The work shall be done as per instruction of Rly engineer at site." DY CSTE-C-JBP-S AND T/WEST CENTRAL RLY Please see Item Breakup for details. 4010709.64 AT Par 4010709.64 Description:- Excavation, casting and plastering (above ground level) of Apparatus case foundation
materials. The items also include additional earth work if required as per instruction of Rly. Engineer at site. Please see Item Breakup for details. 404132.48 AT Par 404132.48
sand and plastering on top of the sand. Please see Item Breakup for details. 697009.46 AT Par 697009.46 Description:- Fabrication and fixing of phenolic board/shelf in location box by providing all fixtures
cable support with contractor's own materials. Lasing and dressing of cables/wires terminated with contractors own supply of lasing thread. The work shall be done as per instructions of Rly engineer at site. Please see Item Breakup for details. 415467.80 AT Par 415467.80 Description:- Installation of Eqpt. (Relays, resistance, chargers & batteries etc.) & wiring of the same in apparatus cases as per location & circuit diagrams with contractor's own PVC wires and
wiring material ( from RDSO approved firms) being used and extant practice in W.C. Rly). Wiring of relays should be with 16/0.2mm wire and all other equipments wiring by 2.5 sq mm multi strand wire of IS 694 of 1990 or latest.
sheets and fixing by galvanised nuts & bolts.This includes provision of two additional holes on the hylam board on either side for cable conductor entry. The work shall be done as per Engg. at site. Per
Conductor Description:- Termination of cable cores on ARA/ disconnecting type terminal, fuse blocks, 8 way
ferrules etc. and all associated works of pulling out the cable from underground, dressing of cable, making wiring tree etc. This includes soldering of armour tree/ring of cables and connecting to copper plate through GI wire bus bar in location boxes. The work shall be done as per location plans and instructions of Rly engineer at site.
Description:- Digging and fixing of earth Electrode assembly as per Drg. No. S&T/CON/KOTA/Earthing/01 ALT-01 and connecting through stainless steel wire 8 SWG supported on MS flat of size 5mm x 40mm to earth electrode as per drg. No. T/2014/1 for signals and T 2014/5 for location boxes/ Apparatus cases. The earth value should be less than 10 Ohms including the lead wire. The value should be measured in presence of Rly. Supervisors. It should be documented and
other material required for provision of earthing will be brought by the contractor. This earth can be provided for DPs block instruments & ELD etc. also, so as to achieve the desired earth resistance value. Earth enclosure to be manufactured & supplied by contractors own material of ratio 1:3:6, without cover. Additional connection of earth pipe including parallel connection with other earth pipes with the function shall be done using left over pieces of signaling cable. Laying of cable pieces shall be covered in laying of cable item and cable shall be supplied by Railways.
Description:- Erection, Fitting and Rail connection of Track Lead Junction Box with contractor's fixing material and jacketed wire rope including 7mm single groove galvanized channel pin for track lead connection including two vertical angle of size 40 x 40 x 5 mm 1200 mm length. This will
site.PVC jacketed galvanized steel wire ropes of 6mm dia (7 x 19 strands) sheathed with PVC of 2mm wall thickness and over all thickness of 10mm for connection between the TLJB and the rails are to be used and to be supplied by the contractor. PVC sheath should be made of type 6 compound as per IS 5831 of 1970. Double wire ropes are to be connected between each rail and TLJB.
Description:- Provision of bonding with contractor's materials including 7mm single groove
two jumpers for each bond, clipping of bonds etc. with contractors own materials and tools as per instruction of Rly engineer at site.GI wires of 4mm dia (8 SWG) are to be used for jumpers across fish plates which should be supplied by the contractor free of cost.
DY CSTE-C-JBP-S AND T/WEST CENTRAL RLY
grade sulphuric acid and distilled water with minimum two charge - discharge cycles, installation of charged batteries in groups & their connection & wiring. The work shall done as per extant practice on W.C. Rly & the instruction of site engineer. The sulphuric acid & distilled water to be used for charging shall conform to specification IS 266-1961 & IS 1070- 1960 respectively. Numbers = Per cell."
Description:- Fixing of point machine on newly laid turnout on Wooden/MBC/Steel sleepers & fixing of ground connections. Adjustment and testing with crank handle operations. This will include fixing of bend pipes with welded frame for cable entry to machine. This will also includes necessary adjustment and smithy work, drilling of Holes to tongue rails, gauge plate & steel sleeper, fitting of insulation for tongue attachment, gauge plate & William stretcher. This also includes cable entry to
point machine (Necessary wiring modification for independent detection) using 2.5 sq mm insulated copper wire as per IS 696 of 1990 with suitable lugs supplied by contractor.. ARA terminals are to be suitably fixed on channels inside point machine . Supply & filling of SAE 30 lubricating oil (500ml approx). The work shall be done as per extant practice on W.C. Rly & the instruction of Rly engineer at site. ARA terminals will be supplied by Railway.It also include Fixing/refixing during tamping of turn out.
Description:- Fixing/refixing of electric point machine, ground connections during phase working (NI / Pre NI), after removing the existing fittings if any, adjustment and testing with crank handle operation. This will include fixing of bend pipes with welded frame for cable entry to machine. This will also includes necessary adjustment and smithy work, drilling of Holes to tongue rails, gauge
This also includes cable entry to the point machine and termination of tail cable in point machine on ARA terminals and wiring of point machine (Necessary wiring modification for independent detection) using 2.5 sq mm insulated copper wire as per IS 696 of 1990 with suitable lugs. ARA terminals are to be suitably fixed on channels inside point machine . Supply & filling of SAE 30 lubricating oil (500ml approx). The work shall be done as per extant practice on W.C. Rly & the instruction of Rly engineer at site.
Description:- Fixing of Electrical high thrust (220mm) point machine on the extended sleepers at thick web point as per section of rails used. Item included fixing of switch extension bracket ,fixing ground connection, adjusting opening of the switches and adjusting of the point machine with crank handle. the item also includes (i) Complete material for installation of point machines and fixing of ground connection / switches extension bracket like point insulator materials, S pipe, supply of
& fitting works required at site for complete installation. (iii) Installation of gauge tie platc & providing insulation for gauge tie plate. (iv) wiring inside the point machine insertion and termination of tail cable in point machine and junction box/Cable hut as per extent practice of WCR and the instruction of railway Engineer at site.(v) Supply and fixing of suitabe size GI piper with flange for taking cable in to point machine, Electricals point machine, ground connection and M6 screw less terminals will be supplied by Railways covered in Schedule separately.
Description:- Excavation of trench as per cable route plan, 1.2 mtr deep, 300mm wide at the bottom along main line in normal soil, This work includes covering of cable laid in trenches by loose soil for a layer of 50 mm thickness approximately before covering by shahabad stone/bricks,
of the required quantity of cables as per instructions of Engineer at site. If it is not possible to reach the required depth at any location, then the contractor shall obtain prior approval of Engineer-in- charge before commencement of cable laying process and only then shall the proportionate payment be made to the contractor.
Description:- Excavation of trench as per cable route plan, 1 mtr deep, 300mm wide at the bottom along main line in hard soil / murum, This work includes covering of cable laid in trenches by loose soil for a layer of 50 mm thickness approximately before covering by Shahabad stone/bricks,
of the required quantity of cables as per instructions of Engineer at site. If it is not possible to reach the required depth at any location, then the contractor shall obtain prior approval of Engineer-in- charge before commencement of cable laying process and only then shall the proportionate payment be made to the contractor.
crossing and refilling after laying of DWC/RCC/GI pipes. The work shall be done as per extant practice on W.C. Rly & instruction of Rly engineer at site.
DY CSTE-C-JBP-S AND T/WEST CENTRAL RLY
X 300 mm wide approximately and refilling, after laying of GI pipe and to restore the road to original condition. The work shall be done as per extant practice on W.C.Rly & instruction of Rly engineer at site.
Description:- Execution of trenchless Boring(HDD) work (boring size upto 125 mm) upto a depth of
includes supply & laying of DWC HDPE pipe as per specification No IS-14930 Part-II or latest of 120 mm OD/103 or 103.5 mm ID.
Description:- Preparation of Cable way 150 mm wide at the bottom and 300-500 mm deep in rocky
and grouting the ends at either side of the rocky portion using concrete mixture with Contractor's own cement & other materials.
Description:- Supply & laying of Fly Ash bricks of size 225x100x75mm as per specificationconfirming to IS 12894-2002 inside the trench (with the brick length being
signal or at any other location as per instruction of Site Engineer. Note: - Size of bricks to be got approved by Site Engineer. In case brick size is in variance with the size given in the tender schedule then proportionate payment on volumetric basis shall be paid to contractor subject to a maximum limit of schedule rate.
required as per the instruction of the engineer at site.
Description:- Fixing of GI pipes for crossing the culverts, stone bridges etc. and concreting the ends with brick masonry at both ends as per the instructions of Rly. Engineer at site with
mixture of 1:3 ratios. (Supply of GI pipes is not covered in this item). 3 perforation of 0.6mm dia per meter shall be made on the GI pipe as per the instructions of Engineer at site. This includes fixing with contractors own MS Chanel, clamps of proper size etc as per instructions of engineer at site.
53 Description:- "Laying of signalling/Power/Telecom cable of various cores/sizes in trenches."
Description:- "Supply & fixing of Concrete Cable Marker as per drawing SDO/Cable Laying/020.
etc .along the cable route The work shall be done as per extant practice on WCR & the instruction of Rly engineer at site. INSPECTED BY CONSIGNEE"
of IBS,Block,Axle counter circuits or any other requirement." Please see Item Breakup for details. 266017.76 AT Par 266017.76 Description:- Painting two coats of enamel paint over one coat of Red Oxide primer on the following items after scrapping and cleaning of the surface wherever necessary. Primer and Paints
instructions of Rly engineer at site and extant practice on W.C Rly on location boxes, signal posts, TLJB. This includes lettering/Numbering of signals, point machine, TLJB, Block joints, apparatus cases also Termination particulars, equipment names etc. legibly and neatly inside location boxes etc.
appratas cases etc ( each item to be taken as one unit ) Please see Item Breakup for details. 75209.56 AT Par 75209.56
neatly inside location boxes.It also includes supplyof Ferrules with Printed letters/PVC sleeve with printed details of cores shall also be provided on each cable conductor.
Description:- "Provision of screen on signals when they fall with in two meter fron the conductor by
site by Engineer incgarge. This includes supply of all material including earth electrode and earthing arrangement."
Cubic Centimetre - Cubic Metre" DY CSTE-C-JBP-S AND T/WEST CENTRAL RLY
Description:- "Providing brick masonary in ratio 1:6 cement (ISI mark) & mortear inclding
bricks sand & cement including excavation curing grouting bolting e.t.c. wherever required as per instructions of Railway Engineer at site. Cubic centrimetre - Cubic Metre."
Description:- Shifting of Existing apparatus case with foundation by crane or by other means upto
disconnection by railway representative). This includes all type of labours charges and filling of locations foundation with river bed sand and plastering on top of the sand.
Description:- "Patching work in old location consisting (i) Digging of pit, cleaning of earth from all
(ii) Insertion of cable from ground.(iii) making place from cable termination in old location, shifting of ARA, fuse etc after removal of termination ,including shifting of ARA.(iv) Termination of cable in old location.(v) Sand filling and plaster" Per Unit = Per Location
Description:- "Supply,Installation.Testing and commissioning of Class A type Surge protection system consisting of :-" a) Active ESE Lightening conductor as per NFC17- 102 b) Should provide radius of protection of 146 m Model no LAP-DX-250 or or equavalent,,tested from international HV test laboratorycertificate for the same. c) Issued to OEM of lightening conductor should be attached
Stainless steel material with pointed tip. g) Delta T should be greater and equal to 96 micro second. h) Inhouse certificate from manufacturer should be provided with material. i) It should be testable by means of external tester. j) GI mast 5m with adopter head and base plate for connecting ESE lightening conductor. K) Lightening counter testable of 6 digits non restable type of stainless steel of material having IP 65 protection manufacturer of 6 digit non restable type of stainless steel material having IP 65 protection.
Description:- "Installation wiring testing and commissioning of fuse change over system (FACS).
of fuse details. This also includes fabrication of frame for installation of FACS at station/LC gate where installation of relay racks not feasible."
Description:- "Installation of Diesel generator set complete system. This includes casting of
installation of panel, out let for exhaust, wiring of D. G. set & panel. This includes transportation, Loading and unloading of DG set complete from depot to the site of installation. The work to be done as per extant practice on W.C. Rly & instruction of Rly engineer at site." Per Unit = Per KVA
bulbs(230V/110V) with contractor own material for location boxes (Anchor make or ISI mark) INSPECTED BY CONSIGNEE"
Description:- Installation/modification of Central Evaluator of Axle Counter, wiringfrom the CT rack
Central Evaluatorincluding the supply of shieldedcable of required conductor size asapplicable with other accessories.Earthing as per manufacturersspecification with their own material
Description:- Design, Supply, transportation,Installation, testing &Commissioning of Multi Section Digital Axle Counter (MSDAC)complete with allaccessories, Cable required with each track device & Card Viz., Axle Detectors,Track Side Electronics/ DAC fieldunits, supply of HDPE pipes for laying oftransmitter and receivercables for rail contacts tolocation boxes / DP &installation of EJB/ Trackside electronics inside thetrack side housing, Deflector plates. CentralEvaluator (Central Evaluator unit should be housed in a pre-fabricated Rack to besupplied along withthesystem), Relay unit,Reset boxes, Eventlogger, Diagnosticterminal etc. as per SpecificationNo.RDSO/SPN/176/2013Ver.3 or latest. along with Tool kit and allaccessories for
autosignalling / Absolut architecture.Modems and suitablecommunication modulesfor exchange ofdata/information such assignal aspect,trackoccupancy status and anyother vital informationbetween evaluators atstations and auto huts forachieving the functionaland circuitry requirementfor Auto signaling / Absolut systemin the shall be providedby the OEM along with MSDAC schedule . Supply of Maintenance free earth& Location/ Mushroom asper RDSO & OEMrequirements. Note: 1)Per DP supply includes allaccessories such ascables for wiring, relays,different indoor & outdoorcards, earthingof DP,L/Boxes/Mushroom, LVetc. 2) Supply of 10%Essential spares of theMSDAC equipmentssubject to minimum oneof each type to besupplied. 3). Portableservice terminal 4) Toolkit (Number= Per DP) DY CSTE-C-JBP-S AND T/WEST CENTRAL RLY
Description:- "Modification in existing track device: Releasing of existing track device and Installation oftrack device(double rail contact of digital axle counter)includes digging of trench,track crossing,laying of double walled antirodent corrugated pipe from track device to location box and making its terminations.Fixing of deflector plates.(double walled antirodent corrugated pipe made
supplied by the firm) this also includes supply of HDPE pipes for laying of transmitter and receiver cables for rail contacts to location box.Casting of foundation for track side housing & erection of track side housing if required.Installation & wiring of EJB/track side Electronics inside the track side housing (this housing will be supplied and installed on foundation by the contractor with his own material) including supply of wires and other accessories.This also includes releasingof existing track device & EJB from site,painting and writing on detection points and track side housing covers. "
Description:- Installation, wiring, testing and commissioning of electrically operated lifting barrier,
power supply connection & wiring with complete outdoor work.The work shall be done as per approved panel, extant practice on W.C. Railway & the instructions of Rly engineer at site.It also include fixing & wiring of control palel as per instruction of site engineer.
Description:- Installation, testing & commissioning of Remote Terminal Unit (RTU) complete along
includes loading of networking software and networking with data logger. The requisite communication cable/channel for networking will be arranged by Railway. Please see Item Breakup for details. 1875039.48 AT Par 1875039.48
make assembly, movement drive mechanism, resting stand etc. as per following technical specification and as per drawing enclosed.
NB (1) Any other items required to Station complete and commission EI system as per latest guideline of Railways/RDSO & as per instruction of Engineer in- charge to make EI system fit for the purpose in terms of reliability.Availability,Maintainability & Safety of complete EI system (Indoor pertaining to EI system configurations) shall be provided free of cost by the contractor NB:(2)Tenderer may quote any RDSO approved EI system with complete details of all modules, cards and accessories alongwith necessary spares as per RDSO specification no NoRDSO/SPN/192/2019Ver 2.0 with latestamendment .Please give full details of quantities & unit based rates item wise the total amount of which must be equal to the given LAR of this item i.e. Rs 15043246.16 in performa to be attached by the tenderer as Annexure to this schedule for commissioning of proposed RDSO approved EI system NB (3) This item includes supply of the following essential spares to the extant of 10% of the quantities installed ( subject to minimum 1 number) (i) Each type of Input/Output cards, processor cards (ii) Each type of relays for indoor application. (iii) DC DC converters of all voltages/each type.(iv) Any other cards/System/sub systems which are specific for OEM based EI system (v) Switches connectors fuses couplers. Details to be submitted by OEM in Annexure form. (vi) It also include supply, fixing, wiring of all type of hard counter, counter box other requirement as per instruction of site incharge. (vii) This includes all softwares with complete FAT set-up for FAT testing at site. FAT set-up includes all required modules/accessories like ethernet cable, bub/switch,connectors or any other item required to perform the FAT testing at site with contractor own PC and laptop. (Viii) It also inclued supply fixing, wiring of Industrial grade inverter (Gallant or similar) (input voltage 24 v DC nominal from IPS and output 230 V AC , pure sine wave along with SPD) for each VDU (ix) This includes minor alteration arised due to either revision in SIP or any other reason in EI system (upto 30% free of cost if required during execution of work i.e. assition/deletion of contacts upto 30% as desiredfor safe train operations, as per approved or revision ST/LT as per the same terms & conditions of the contract. For variations beyond 30% additional payment shall be made. Total 75216230.80 Supply of 4 conductor disconnect screw less, spring cage type terminal blocks for test and Item- 21 measurement suitable for at least 2.5 mm2 conductor S No. Item Description of Item Unit Qty Rate Amount No DY CSTE-C-JBP-S AND T/WEST CENTRAL RLY
Supply of 4 conductor disconnect screw Numbers 38000.00 less, spring cage type terminal blocks for test and measurement suitable for at least 2.5 mm2 conductor similar to model No. 280- 874 of WAGO make or model No. ST 2.5- QATTRO- MT of PHOENIX or model No. DSDT- 2.5 (2x2) of ELMEX make. Material to be supplied after approval of engineer in charge.(Wago part no 280-874)as per RDSO specification RDSO/SPN/189/2004,Rev 3.0 INSPECTION BY RITES.
Supply of End plate compatible to above Numbers screwless terminals. The end plates shall be of different colour than that of disconnect terminal blocks. INSPECTION BY CONSIGNEE.
Supply of End Stop for above Din 35 Rail of Numbers WAGO or PHOENIX or ELMEX make. INSPECTION BY CONSIGNEE.
Supply of Din rail of dimension 35mm x Metre 7.5mm, 1 mm thickness, 1Mtr length, slotted compatible to above terminals of WAGO or PHOENIX or ELMEX make. INSPECTION BY CONSIGNEE. Total 3592636.00 Supply, installation, testing and commissioning ofUL/FM/VDS/LPCB approed Microprocessor based networkable analogue addressable and modulartype of Fire alarm control panel with display, in Item- 27 bultcharging facilities and provision of GSMmodulesuitable to send SMS to configured moblieno. Thepanel should be equipped with nos. ofloopsand provision of expandability as per RDSOspecification no RDSO/SPN/217/2025 ver 3.1 or latest S No. Item Description of Item Unit Qty Rate Amount No
Supply, commissioning ofUL/FM/VDS/LPCB approed Microprocessor based networkable analogue addressable and modulartype of Fire alarm control panel with display, in bultcharging facilities and provision of GSMmodulesuitable to send SMS to configured moblieno. Thepanel should be equipped with nos. ofloopsand provision of expandability as per RDSOspecification no RDSO/SPN/217/2025 ver 3.1 orlatest
Supply, commissioning of resettable, addressable multi sensor ( Heat &Smoke) which is fully compatible with analogue addressable protocol, Electronically addressed. ( Asper RDSO/SPN/217/2025 ver 3.1 or latest)This item includes supply of the essential spares to theextant of 10% of the quantities installed will alsobe supplied by contractor as spare Qty . ( subjectto minimum 1 number). INSPECTION BY RDSO
Supply, commissioning of addressable, resettable manual call point withintegral short circuit isolator, having status LED foralarming & Stand by mode, Electronically addressed. ( As per RDSO Specification no.RDSO/SPN/217/2025 ver 3.1 or latest) This itemincludes supply of the essential spares to theextant of 10% of the quantities installed will alsobe supplied by contractor as spare Qty . ( subjectto minimum 1 number).. INSPECTION BY RDSO DY CSTE-C-JBP-S AND T/WEST CENTRAL RLY
Supply, commissioning of analogue type linear heat sensing cable. ( As perRDSO Specification no. RDSO/SPN/217/2025 ver3.1 or latest) This item includes supply of theessential spares to the extant of 10% of thequantities installed will also be supplied bycontractor as spare Qty . INSPECTION BY RDSO
Supply, installation and testing and Numbers commissioningof module of LHS cable to be integraced on fire alarm panel. ( As per RDSO Specification no.RDSO/SPN/217/2025 ver 3.1 or latest) This itemincludes supply of the essential spares to theextant of 10% of the quantities installed will alsobe supplied by contractor as spare Qty ( subject tominimum 1 number). INSPECTION BY RDSO
"Supply, installation and testing and Numbers commissioning of addressable Loop powered wall sounder/alarm. ( As per RDSO Specification no. RDSO/SPN/217/2025 ver 3.1 or latest) This item includes supply of the essential spares to the extant of 10% of the quantities installed will also be supplied by contractor as spare Qty ( subject to minimum 1 number). INSPECTION BY RDSO"
"Supply, commissioning of FRLS/Fire survival circuit integrity cables i.e armored cable (2 core ,1.5 sqmm )& Power cable( 3 core multistrand 2.5 sqmm)( with all accessories for connection of all fire alarm devices. ( As per RDSO Specification no. RDSO/SPN/217/2025 ver 3.1 or latest)( (each lot having 300 mtr armoured cable and 80 mtr power cable(Additional quantity if required during installation shall be supplied by contractor without additional cost) .This item includes supply of the essential spares to the extant of 10% of the quantities installed will also be supplied by contractor as spare Qty .INSPECTION BY RDSO"
"Supply, installation and testing and System commissioning of Aspiration Type smoke Detection System complete. ( As per RDSO Specification no. RDSO/SPN/217/2025 ver 3.1 or latest) INSPECTION BY RDSO" Total 2946480.87 Supply of Resettable fuse, type Polymeric Positive Temperature Coefficient (PPTC) fuse of make Item- 68 Little fuse /Fuzetec /Tyco/Bourn/Raychem, suitable fuses with trip current shall be supplied as per requirement given below. INSPECTION BY CONSIGNEE. S No. Item Description of Item Unit Qty Rate Amount No
110-130Vac ,6A Total 56731.40 DY CSTE-C-JBP-S AND T/WEST CENTRAL RLY "Supply of Apparatus cases with miniature E Type Locks with keys as per spec. No IRS S 30/64 & Item- 96 RDSO Drg. No. SA 3376/M with latest amendments. INSPECTION BY RITES." S No. Item Description of Item Unit Qty Rate Amount No
Single case as per Drg No WS-8842/A with Numbers latest alteration.
Half Case as per Drg No WS-8842/A with Numbers latest alteration. Total 6247342.58 Supply & installation of maintenance free earth consisting as per RDSO specification No. RDSO/SPN/197 (version 3.1 or latest) or consisting of single earth pit which includes supply of 35 mm²/16 mm²/10 mm² multistrand single core PVC insulated copper cable as per IS 694 for connecting main earth electrode to MEEB in the equipment room in duplicate as per manufacturers recommendations and as per RDSO specifications as follow: (1) Copper bonded steel electrode of 3.0 meters long, 17 mm diameter with copper bonding thickness of minimum 250 microns and UL listed and marked: 1 No. (2) Earth enhancement compound of RDSO approved brand supplied in sealed bag of minimum 10 KG: 3 Nos. (3) Copper strip of 200mm X 25 mm X 6 mm to terminate earth rod: 1 No. (4) Copper strip of 300mm X 25 mm X 6 mm (MEEB): 1 No. (5) Copper strip of 200mm X 25 mm X 6 mm (MEEB): 1 No. Installation of maintenance free earth includes:Digging/auguring/boring of single earth pit of 100 mm to 125 mmdiameter to the depth of approximately 2.8 meters. Insertion of three meters electrode and penetrating it atleast 0.2 meters Item- by pushing gently with sledge hammer where the neutral soil is assumed. Filling of earth pit with 105 earth enhancement compound (EEC) in slurry form and back filling. Carrying out exothermic weld connection of single earth electrode to a copper tape of 200 mm X 25 mm X 600 mm. Carrying out exothermal weld connection on the copper tape of 200 mm X 25 mm X 6 mm on earth electrode for connecting two 35 mm² cable for redundancy. The exothermal welding material for bonding the earth system shall be procured from RDSO approved firms which includes graphite moulds, clamps, weld metal powder. 400 mm X 400 mm X 400mm(inside dimension) concrete earth pit with a concrete lid approximately 50 mm thick with pulling hooks shall be provided to cover the pit. Back side of the cover will be painted in black and date of testing and average earth resistance value shall be written. SUPPLY PORTION INSPECTION BY CONSIGNEE of single earth pit which includes supply of 35 mm²/16 mm²/10 mm² multistrand single core PVC insulated copper cable as per IS 694 for connecting main earth electrode to MEEB in the equipment room in duplicate as per manufacturers recommendations and as per RDSO specifications as follow: SUPPLY PORTION INSPECTION BY RDSO S No. Item Description of Item Unit Qty Rate Amount No DY CSTE-C-JBP-S AND T/WEST CENTRAL RLY
(1) Copper bonded steel electrode of 3.0 Numbers meters long, 17 mm diameter with copper bonding thickness of minimum 250 microns and UL listed and marked: 1 No. (2) Earth enhancement compound of RDSO approved brand supplied in sealed bag of minimum 10 KG: 3 Nos. (3) Copper strip of 200mm X 25 mm X 6 mm to terminate earth rod: 1 No. (4) Copper strip of 300mm X 25 mm X 6 mm (MEEB): 1 No. (5) Copper strip of 200mm X 25 mm X 6 mm (MEEB): 1 No. Installation of maintenance free earth includes:Digging/auguring/boring of single earth pit of 100 mm to 125 mmdiameter to the depth of approximately 2.8 meters. Insertion of three meters electrode and penetrating it atleast 0.2 meters by pushing gently with sledge hammer where the neutral soil is assumed. Filling of earth pit with earth enhancement compound (EEC) in slurry form and back filling. Carrying out exothermic weld connection of single earth electrode to a copper tape of 200 mm X 25 mm X 6 mm. Carrying out exothermal weld connection on the copper tape of 200 mm X 25 mm X 6 mm on earth electrode for connecting two 35 mm² cable for redundancy. The exothermal welding material for bonding the earth system shall be procured from RDSO approved firms which includes graphite moulds, clamps, weld metal powder. 400 mm X 400 mm X 400 mm(inside dimension) concrete earth pit with a concrete lid approximately 50 mm thick with pulling hooks shall be provided to cover the pit. Back side of the cover will be painted in black and date of testing and average earth resistance value shall be written. Total 1572362.48 Item- Supply of Multiport Front end processor with one modem as per RDSO Spec. IRS.S.99/2006 109 S No. Item Description of Item Unit Qty Rate Amount No
Supply of Multiport Front end processor Numbers with one modem as per RDSO Spec. IRS.S.99/2006 or latest. INSPECTION BY CONSIGNEE.
Supply of Dual EI convertor card for Numbers networking MFEP INSPECTION BY CONSIGNEE.
Testing & Commissioning of Multiport Front Numbers end processor INSPECTION BY CONSIGNEE. Total 904789.08 Schedule Schedule B -Execution Excavation, casting and plastering (above ground level) of Apparatus case foundation with Item- 31 contractors own Metal Sheet frame, cement, anchor bolts with nuts & washers and other materials. The items also include additional earth work if required as per instruction of Rly. Engineer at site. S No. Item Description of Item Unit Qty Rate Amount No
Single case as per Drg No JBP/S&T/C/084
Half case as per Drg No JBP/S&T/C/085 Total 4010709.64 Erection of apparatus cases.This includes filling of location foundation with river bed sand and Item- 32 plastering on top of the sand. S No. Item Description of Item Unit Qty Rate Amount No DY CSTE-C-JBP-S AND T/WEST CENTRAL RLY
Half Case. Total 404132.48 Fabrication and fixing of phenolic board/shelf in location box by providing all fixtures and insulators as per Railway Drawing including fixing of PVC coated string rods at the back side for cable support Item- 33 with contractor's own materials. Lasing and dressing of cables/wires terminated with contractors own supply of lasing thread. The work shall be done as per instructions of Rly engineer at site. S No. Item Description of Item Unit Qty Rate Amount No
Half Case. Total 697009.46 Installation of Eqpt. (Relays, resistance, chargers & batteries etc.) & wiring of the same in apparatus cases as per location & circuit diagrams with contractor's own PVC wires and wiring material. The work shall be done as per instruction of Rly engineer at site and approval of wiring Item- 34 material ( from RDSO approved firms) being used and extant practice in W.C. Rly). Wiring of relays should be with 16/0.2mm wire and all other equipments wiring by 2.5 sq mm multi strand wire of IS 694 of 1990 or latest. S No. Item Description of Item Unit Qty Rate Amount No
Half case. Total 415467.80 Painting two coats of enamel paint over one coat of Red Oxide primer on the following items after scrapping and cleaning of the surface wherever necessary. Primer and Paints both Asian paints / Berger / Shalimar are to be supplied by Contractor. The work shall be done as per instructions of Rly Item- 56 engineer at site and extant practice on W.C Rly on location boxes, signal posts, TLJB. This includes lettering/Numbering of signals, point machine, TLJB, Block joints, apparatus cases also Termination particulars, equipment names etc. legibly and neatly inside location boxes etc. S No. Item Description of Item Unit Qty Rate Amount No
Appratus case full size
Appratus case half size
Main Signal post with signal unit, surface Numbers base and complete fittings as per W.C.Rly. Standard practice.
Shunt Signal post with signal unit, surface Numbers base as per W.C. Rly.Standard practice.
Track lead junction box. ( Black enamel out Numbers side only)
Point machine with ground connection Numbers complete. ( Point machine with black enamel only out side and ground connection with red oxide) Total 266017.76 Lettering numbering termination particulars, equipments names etc legibly and neatly inside Item- 58 location boxes.It also includes supplyof Ferrules with Printed letters/PVC sleeve with printed details of cores shall also be provided on each cable conductor. S No. Item Description of Item Unit Qty Rate Amount No
Half case Total 75209.56 Fabrication, supply, transport, errection at site, sliding type mechanical type boom, make Item- 73 assembly, movement drive mechanism, resting stand etc. as per following technical specification and as per drawing enclosed. S No. Item Description of Item Unit Qty Rate Amount No
M.S. Boom 65 mm dia 10/12 mtrs long Numbers dividing in two pieces nut and bolts arrangements, pulling hand and boom locking arrangements etc. DY CSTE-C-JBP-S AND T/WEST CENTRAL RLY
Resting stand made up of c channel Numbers 150mm X 75mm X 6mm thick for resting the boom movement frame/ meeting post grouting type.
Boom movement rectangular frame made Numbers up by C channel 75mm X 37mm X 6mm 9.5mtrs long and 250mm width (it should diveded in two pieces nut and bolt arrangement with necessary boom movement rollers arrangement and boom driving mechanism made up of 4 ball bearing, boom replacement arrangements etc.
Excavation foundation for resting stand/meeting (approx 10-12 Nos.)
Supply of paint of approved quality and Lumpsum painting of sliding type boom, boom movement frame, resting stand, meeting post etc. As per regular standard practice with 2 coats of enamel paint black and yellow colour with 12 mm width retro reflective RED, Yellow striker. Rates included for all required nut and bolts, chains, pad locks 2 Nos. and other miscellaneous are supplied by the contractor. Total 1875039.48
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
TenderDocument-138.pdf
ATTACHMENT
Annexureanddrg_compressed.pdf Annexure and drawings
ATTACHMENT
Signallingplan.pdf
ATTACHMENT
Annexureanddrg_compressed.pdf
ATTACHMENT
Download all tender documents and submit your bid