| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.8 LAccepted-AOC 30 2 RAJKUMAR MUKHERJEE ROAD KOL 700035 | KOLKATA | KOLKATA | WEST BENGAL | 700035 | L1 | Accepted-AOC L1 BIDDER | |
| 2 | L2₹9.9 L+₹2,256.08 (0.23%)Rejected-Finance DASPURA MONIRAMPUR BARRACKPORE KOLKATA 700120 | KOLKATA | NORTH 24 PARGANAS | WEST BENGAL | 700120 | L2 | Rejected-Finance NOT L1 BIDDER | |
| 3 | L3₹9.9 L+₹3,483.63 (0.35%)Rejected-Finance 23 2 P K CHOWDHURY LANE HOWRAH 711103 | HOWRAH | HOWRAH | WEST BENGAL | 711103 | L3 | Rejected-Finance NOT L1 BIDDER |
Tender Value
₹9.9 L
EMD Value
₹20,400
Closing Date
29 Aug 2024, 2:30 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EXECUTIVE ENGINEER,CMD.
EE,CMD, 5TH FLOOR, PURTA BHAVAN
Making_illumination_arrangement_and_mise_works_at_LOHAI_water_supply_scheme_RAINA_II_BLOCK_under_Central_Mechanical_Division_P_H_E__Dte__Purba_Bardhaman__
2024_PHED_729414_12
WBPHED/EE/CMD/ENIT-08/2024-25
Open Tender
Electrical Work/ Equipment
Item Rate
60 days
PURBA BARDHAMAN
Making_illumination_arrangement_and_mise_works_at_LOHAI_water_supply_scheme_RAINA_II_BLOCK_under_Central_Mechanical_Division_P_H_E__Dte__Purba_Bardhaman__
5 documents required · 5 mandatory
₹20,400
14 May 2025
15 Aug 2024
2 Sept 2024
15 Aug 2024
29 Aug 2024
15 Aug 2024
Amount
Supply & delivery of following materials at below mention sites :-
GRP street light pole in conical shape using thermoset resign having minimum 65% glass content with following specifications : Length – 7 mtr. Top I.D – 85 + 2 mm. Bottom I.D – 176 + 2 mm. Thikness – 5 + 0.5 mm. Type – Non buried (above ground) The above pole is provided with suitable size MS base plate, foundation bolt & nut set, internal junction box & MS ring arm [Make -Fibro Plastichem / EPP/ PHE approved] (Test certificate will be submitted at the time of delivery) [Installation will be done based on the site condition]
16 sq. mm 2 core 1.1 KV grade XLPE insulated Al. armoured Cable conforming to IS:7098 (Part-I) 2011 with upto date amendments. [Make- Gloster/ Mescab/ Currency/ Crystal/ Polycab/ PHED approved Make]
100W LED flood light luminarie with IP 65 protection. [Make: Philips (Type- BVP)/ Havells/ PHED approved make]
40W LED Decorative Post top for 3600 light with IP 65 protection for gate light. [Make: Havells (Type- RUBYPT40W) / Philips/ PHED approved make]
GRP street light pole foundation work :
Making RCC foundation (as per drawing & measurement provided by GRP Pole manufacturer) for pole erection by using suitable reinforcement & concrete grade M20 inlcuding making provision looping cable line, excavation & refilling of earth pit with shifted soil & ramming properly as per specification & direction of EIC .
Al. ar. Cable laying work :
Laying of one no 16 sq.mm. PVC Al. Ar. cable in underground trenche 460mm. wide X 760mm. average depth, with brick protection on the top of the cable with 8 (eight) nos. bricks per mtr, including filling the space between the brick & cable & also the trench with shifted soil, levelling up & restoring surface duly rammed.
Laying 16 sq.mm. PVC Al. Ar. Cable through pump house wall including supply of sockets for clamping and grouting the above cable in each pole foundation (Approx 10 mtr length)
Supply & delivery of outdoor type Kiosk box (Size: 10"x 6"x12") with suitable gauge M.S. sheet along with hinged type front door with locking arrangement including M.S leg angle frame covered consisting 3 way Aluminium busbar 63 amp. fixed on a Porcelain material and grouting its legs in rick piller.
Installation of above supply Kiosk bok (item no.-3, c) and making brick/PCC foundation (Size: 14"x 10"x 18") with supplying bricks/stonechips, sand, cement etc including plastering and neat cement & making electrical connection complete as per direction EIC
LED set fitting & electic connection work :
Supply & drawing of 2 X 2.5 sq. mm and 1 x 1.5 sq. mm (for earthing) FR PVC insulated 1.1 KV grade single core copper cable (PHED. approved make) from pole junction box to LED fixture at the top of the pole and making electrical connection complete
Erection of GRP pole on RCC foundation with help of MS base plate, foundation bolts, nuts, washers etc. and fitting & fixing of four (4) nos. flood light luminaris on pole ring arm with necessary inter connection and jointing of cable and testing complete of entire set as per direction EIC
Supplying and fixing GI/PVC water proof type looping cable box of required size comprising with one 250 volt, 15amp kit kat fuse unit, one NL on porcelain insulator with locking arrngement fitted on brick wall with proper clamping arrangement for gate light
Fixing outdoor type gate light fitting on gate with supply upto 50 mm dia GI pipe as required length and making electrical connection by Al. armoured cable from loop box to light fiting (without controlling switch) laying over CC foundation including clamping & other necessary materials required to complete electrical connection.
Earthing of Loop Box by spike earhing (20mm X 2 mtr.) with drawing 8 SWG GI wire as per IE rule.
Supply & fitting G.I angle with wire net fencing arrangement for Gate light
Supply & fitting fixing 16 Amp. SPN MCB (Make-Havells/ Siemens/ ABB/L&T) with enclosure & 16 Amp Piano key type Switch with pvc box inside the pump house wall and making connectin with supply cable for operating the compund light with supply necessary materials all complete as per direction of EIC.
INSTALLATION OF VOLTAGE STABILIZER
Supply and delivery at site the following items:(Approve make of P.H.E Dte.)
Supply and delivery at site A.C. 3 ph.Oil cooled type Voltage Stabilizer suitable for unbalanced input voltage (Make: AE/Sen & Pandit / Opto Elec. / ECS/Fizi/other Approved Make) a) Input:250-500 V 3ph. 50HZ, 4 wire b) Output, 415V + 1% 3ph.,50HZ. c) Capacity: 25 KVA. d) Auto manual switch IS - 9815 (I). e) Raise/lower push Button. f) Single lamps to indicate and limits of input. g) Voltmeter for input and output Voltage. (Manufacturing test certificate should be produced at the time of delivery) h) With U/V.O./V.O./L protection with contractor at output side, input MCB & Ammeter etc. ( TC /GC Needed ) [Installation will be done based on requirement and suitability of the site condition]
Change over switch 100 Amps 415V, 50 Hz, 4pole onload. Make: Havells/ standard/Approve make of P.H.E. Dte.)
100 Amp. Re-wireable type TPN main switch (CONFORMS: IS/IEC600947-1&3). (Make: Approve make of P.H.E. Dte.)
100 Amp. 4 way Copper busbar chamber box by 16 SWG sheet steel enclosure including porcelain chair etc.. (Make: Approve make of P.H.E. Dte.)
25 sq.mm 3.5 core 1.1KV PVC/XLPE insulated aluminium armored cable. (Make: Approve make of P.H.E. Dte.)
Making brick built foundation with supplying of all required materials suitable for the above Voltage stabilizer by (4:1) cement mortar including holding down foundation bolts (if req.) & plaster with neat cement finish as direction of E.I.C.
Installation of the above stabilizer on the foundation including all connection complete,drawing the cable properly on GI cable tray on wall /as per direction of EIC along with supplying all necessary item including testing complete.
Making joints of the cable by supplying compression type gland thimple,socket etc.as per requirement and as per direction of EIC.
Supply, delivery and storage at site Full Bore Electromagnetic Flowmeter DN 200,Protection IP 68 (Minimum inbuild 20 meter cable,factory potted) ,Full bore type Electro Magnetic Flow meter with smart Transmitter (Volume Flow rate output : 4-20mA HART Output and totalizer pulse output:0.05 cum/Pulse) with LCD 4 line backlit display ,calibration lab as per ISO 17025,Accuracy .5% +/- 2mm/sec,measuring,reference & empty pipe detection electrode with Polyurethane/Hard rubber liner,supply: 24 v DC or 230VAC. [Make-Endress+ Hauser (India) Pvt.Ltd/ Approved Make]
Magnetic Flow Meter DN80
Magnetic Flow Meter DN150
Installation of above mentioned full bore electromagnetic flowmeter (DN80) with laying of cable (DEPT.SUPPLY) and suppling of other fixing material all complete as per direction of EIC.
Installation of above mentioned full bore electromagnetic flowmeter (DN150) with laying of cable (DEPT. SUPPLY) and suppling of other fixing material all complete as per direction of EIC.
Add. GST@18%
Add. Cess@1%
M.S.C ENTERPRISE
TAMAL ENTERPRISE
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .