Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.9 LRejected-Finance | L1 | Rejected-Finance EMD Refund only | |
| 2 | L2₹7.1 L+₹15,468.06 (2.24%)Rejected-Finance | L2 | Rejected-Finance EMD Refund only | |
| 3 | Rejected-Technical | - | Rejected-Technical Non Responsive |
Tender Value
Refer Docs
EMD Value
₹16,000
Closing Date
28 Dec 2020, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
XEN PWD B and R Narnaul
XEN PWD B and R Narnaul
Construction of Guard Room and Main Gate in Govt. College at Narnaul in Mohindergarh District.
2020_HRY_152407_1
Const. of Guard Room and Main Gate in GC NNL 7.98
Open Tender
Civil Works - Buildings
Item-rate/Agreement basic
90 days
Works
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,000
₹16,000
Yes
12 May 2021
7 Dec 2020
29 Dec 2020
7 Dec 2020
28 Dec 2020
7 Dec 2020
120 days
Amount
Dismantling Concrete (HSR 8.6) (d) cement concrete plain 1:2: 4 mi
Dismantling Concrete cement concrete plain 1:4:8 or 1:5:10 (HSR 8.6) b
Earth work in excavation in foundations, trenches, etc.in all kinds of soils, not exceeding 2 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil, clear from the edge of excavation and subsequent filling around masonry, in 15 cm layers with compaction, including disposal of all surplus soil, as directed within a lead of 30 metres(HSR 6.6)
Earth Filling under floors with surplus soil excavated from foundation and taken only from outside the building plinth, in 15 cm layers including ramming watering and consolidating lead up to 30 meters. Subject to condition soil Is non plastic. [HSR 6.13(a)].
Earth work with Tibba Sand in Road & Parking taken from outside of campus area with all lead and lift including loading, unloading, laid in 15 cm layer including ramming, watering, consolidating, compaction, and compensation of earth etc., complete in all respect as per the direction of engineer in charge. (For any lead and lift). [NS].
Cement concrete 1:4:8 with stone aggregate 20 mm nominal size in foundation and plinth. (HSR 10.38)
Cement Concrete 1:4:8 with stone aggregate 40mm nominal size in foundation and plinth(HSR 10.39)
Cement Concrete 1:8:16 with stone aggregate 20mm nominal size in first storeyupto 4 meters above plinth level. (HSR 10.47)
Cement concrete 1:2:4 with stone aggregate 20 mm nominal size in payments, roads, taxi- tracks and runways, laid to required slope and camber, including consolidation, finishing and tamping complete(a) extra over Item Nos. 10.79 to 10.94, if 1:1 ½:3 mix is used, instead of 1:2:4 (HSR 10.132+10.95 a)
Cement concrete 1:2:4 with stone aggregate 20 mm nominal size for reinforced concrete work in footings, strips, foundations, beams, rafts, pedestals and approach slabs of bridges etc, excluding steel reinforcement but including centring and shuttering, laid in position, complete in all respects.(For work upto 1.5 metres below ground level). a) extra over Item Nos. 10.79 to 10.94, if 1:1 ½:3 mix is used, instead of 1:2:4 (HSR 10.90+10.95) a
Cement concrete 1:2:4 with stone aggregate 20 mm nominal size for reinforced concrete work for walls exceeding 20cm thickness (straight and curved) beams, girders, stairs, columns, (square or rectangular) battens and lintels etc. excluding steel reinforcement but including centring and shuttering, laid in position, complete in all respects a) extra over Item Nos. 10.79 to 10.94, if 1:1 ½:3 mix is used, instead of 1:2:4 (HSR 10.86+10.95 a) (i) Ist Storey
ii) 2nd Storey
Cement concrete 1:2:4 with stone aggregate 20 mm nominal size for reinforced concrete work in footings, strips, foundations, beams, rafts, pedestals and approach slabs of bridges etc, excluding steel reinforcement but including centering and shuttering, laid in position, complete in all respects.(For work upto 1.5 metres below ground level). a) extra over Item Nos. 10.79 to 10.94, if 1:1 ½:3 mix is used, instead of 1:2:4 (HSR 10.82+10.95 a) 2nd Storey
Damp Proof Course 40mm thick Cement Concrete1:2:4: (HSR 10.114)
First class brick work laid in cement sand mortar 1:6 in foundation plinth. (HSR 11.2)
First class brick work laid in cement sand mortar 1:6 in 1st storey upto 4 metre above plinth level. (HSR 11.7)
First class brickwork laid in cement sand mortar 1:4 in first storey upto 4 meters above plinth level(HSR 11.9) (i) Ist storey
ii) 2nd storey
11.43 cm thick brick wall with every fourthcourse, reinforced withhoop-iron, laid in 1:4cement sand mortar in super-structure. (HSR 11.46)
Terracing consisting of tiles 22.86 cm x 11.43 Cm x 3.81 cm laid over 87.50 mm mud filling on a layer of 25 mm mud plaster and on other layer of mud mortar for laying the tiles, including two coats of bitumen laid hot at 1.65 kg per sqm on top of R.C.C slab including grouting with cement sand mortar 1:3 and top surface to be left clean etc. (HSR 13.13).
Top khurra 0.6 m x 0.6 m for rain water pipe in 25 mm thick cement concrete 1:2:4 over 50 mm thick cement concrete 1:8:16 (HSR 13.50)
Cement concrete 1:2:4 gola 10cm X 10cm quadrant along junction of roof with parapet wall finished smooth, where specially specified.(HSR 13.64)
Providing and fixing vitrified tiles of size 600 x 600mm of approved make in flooring laid in any pattern as specified over base of 20mm thick cement coarse sand mortar 1:3 and jointed with white cement slurry mixed with pigment to match the shade to tiles. (HSR 14.89) Note: - Tile shall be of premium quality (first quality) of reputed manufacturer like NITCO, KAJARIA, SOMANI, ORIENT, JOHNSONS & RAK.
Providing and fixing vitrified tiles of size 600 x 600mm of approved make in skirting/dado laid in any pattern as specified over base of 12mm thick cement coarse sand mortar 1:3 and jointed with white cement slurry mixed with pigment to match the shade to tiles. (HSR 14.90)Note: - Tile shall be of premium quality (first quality) of reputed manufacturer like NITCO, KAJARIA, SOMANI, ORIENT, JOHNSONS & RAK.
Laying and fixing Granite stone in all shade,15mm to 18mm thick in skirting/dados, risers of steps, pillars, wall facing, laid in any pattern as specified over base of 12mm thick cement coarse sand mortor 1:3 and jointed with white cement slurry mixed with pigment to match the shade of granite including labour for fixing cramps pins and dowels etc. (Excluding the cost of Granite, Granite will be supplied by the Department). (HSR 14.95). (i) 1st Storey
ii) 2nd Storey
Laying and fixing Granite stone in all shades 15 mm to 18 mm thick in flooring, laid in any pattern as specified over base of 20 mm thick cement coarse sand mortar 1:3 and jointed with white cement slurry mixed with pigment to match the shade of granite stone. (Excluding the cost of Granite, Granite will be supplied by the Department). (HSR 14.96). (i) 1st Storey
ii) 2nd storey
15 mm thick cement plaster 1:6 on the rough side of single or half brick wall(HSR 15.12)
12 mm thick cement plaster 1:6 on the rough side of single or half brick wall(HSR 15.7)
Factory manufactured panelled door or glazed window, shutters of commercial hard wood, such as hollock, champ,chikrassy and chaplash,etc.,(non-coniferous timber other than teak, conforming to I.S.specification No.1003,kiln-seasoned),with 100 mm wide vertical styles, 150 mm wide lock rail, 200 mm wide bottom rail and 100 mm wide other rails, with panels of 15 mm thick, tongued and grooved of commercial hard wood and including cost of iron hinges,screws,chocks/cleats,stops,nails etc., complete, fixed in position (excluding the cost of any fittings,other than specified above, but including labour for fixing the same in position). (HSR 17.90) 35mm
Factory manufactured wire gauze door and window shutters of commercial hard wood such as hollock, champ, chikrassy and chaplash,etc.,(non-coniferous timber other teak, conforming to I.S.specification No.1003, kiln-seasoned),with 100 mm wideverticle styles, 150 mm wide lock rail, 200 mm wide bottom rail, and wire gauze of 140G or 120G designationincludingcost of iron hinges, screws, chocks/cleats, stops nail etc.,complete fixed in position(excluding the cost of any fitings,other than specifiedabove,but including labour for fixing the same imposition)-(style and rails of windows shutter shall be 75 mm wide) (HSR 17.92 35mm)
Factory manufactured solid flush door shutters, with block board core as per I.S.No.1659- 1969 bonded with water proof type phenol formaldehyde synthetic resin,hotpressesd,conforming to I.S.2202 part I and II, fixed in position, including iron hinges, screws, chocks/cleats and stops etc.(excluding the cost of any fittings other than specified above, but including labour for fixing the same in position)-(HSR 17.93) 40mm
Iron-grated doors, including pintle hinges and arrangements (HSR 18.11)
Wrought iron and mild steel (using angles, flats square bars, tees and channels) ladders, grills, gratting frames, window guards, iron doors openable or fixed stair case or parapet or any other type of railing, gates and tree guards etc., including cost of screws and welding rods or bolts and nuts complete fixed in position. (HSR 18.12).
Steel reinforcement TMT bars FE-500 EQR/FE-500 D grade or more for RCC work, where no included in the complete rate of RCC including Straightening, bending, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. and placing in position complete in all respects for all heights/depths /storeys/ basements etc. (Note:- Reinforcement shall be measured in length including hooks, if any, separately for different diameters as actually used in work, excluding overlaps. Wastage, overlaps, couplings, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other methods for binding and placing, shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement). (HSR 18.22).
Pressed steel sheet frames (chowkats), consisting of 2 mm thick steel sheet of the specified section, including iron lugs (hold fasts), iron hinges, conforming to P.W.D. specifications, including bolts for fixing stops, lock notch, provision for receiving tower bolts, and finished with one coat of ready-mixed paint red lead non-setting primer, of approved quality, fixed in position including the cost of cement concrete 1:3:6 for filling in the frame, and cement concrete 1:3:6 for lugs complete: - (HSR 18.34 d) door and window frame of size 114 mm X 50 mm with 35 mm wide double rebate
Providing and Applying priming coat with metal primer on new steel or iron work including preparation of surface. Painting on mettalic Surfaces etc. (Note:- 2nd quality paint/primer of reputed make firm such as Goodlass-Nerolac, Berger, Garware, Jenson, Nicholson, Asian & Shalimar Shall be used as approved by Engineer-in-charge in writing, Drum of paint shall be opened in presence of Engineer-in-charge). (HSR 16.9). 2nd Quality
Providing and Applying pink primer or aluminium priming coat on wood work including preparation of surface, knotting and stopping etc. (Note:- 2nd quality paint/primer of reputed make firm such as Goodlass-Nerolac, Berger, Garware, Jenson, Nicholson, Asian & Shalimar Shall be used as approved by Engineer-in-charge in writing, Drum of paint shall be opened in presence of Engineer-in-charge). (HSR 16.2). 2nd Quality
Providing and Applying Painting two coats excluding priming coat with synthetic enamel paint in all shades on new wood work or metallic or plastered or concrete surfaces to give an even shade. (Note:- 2nd quality paint of reputed make firm such as Goodlass-Nerolac, Berger, Garware, Jenson, Nicholson, Asian & Shalimar Shall be used as approved by Engineer-in-charge in writing, Drum of paint shall be opened in presence of Engineer-in-charge). (HSR 16.3). 2nd Quality
Providing and Applying priming coat with cement primer in all shades on newly plastered or concrete exterior surface. (Note:- 2nd quality paint of reputed make firm such as Goodlass-Nerolac, Berger, Garware, Jenson, Nicholson, Asian & Shalimar Shall be used as approved by Engineer-in-charge in writing, Drum of paint shall be opened in presence of Engineer-in-charge). (HSR 16.25). 2nd Quality
Providing and Applying Providing two coats of exterior acrylic emulsion paint. (Note:- 2nd quality paint of reputed make firm such as Goodlass-Nerolac, Berger, Garware, Jenson, Nicholson, Asian & Shalimar Shall be used as approved by Engineer-in-charge in writing, Drum of paint shall be opened in presence of Engineer-in-charge). [HSR 16.79 (b)].
Providing and Applying Distempering with washable oil bound distemper (of approved manufacture) two coats over one priming coat on new work. (Note:- 2nd quality paint of reputed make firm such as Goodlass-Nerolac, Berger, Garware, Jenson, Nicholson, Asian & Shalimar Shall be used as approved by Engineer-in-charge in writing, Drum of paint shall be opened in presence of Engineer-in-charge). (HSR 16.58).
Providing and applying two coats white cement based putty over plastered surface and grindling the surface smooth with sand paper to get an even and smooth finish including cost and carriage of all material, labour charges, scaffolding, sundries etc. complete. (Note:- reputed make Putty such as J.K./ Birla shall be used as approved by Engineer-in-charge). (HSR 16.81).
The Green Haryana Coop LC Society Ltd.
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .