Providing and Fixing of Fire Safety System at New Academic Block Green Building under DBRAIT
2021_APWD_2801_1
NIT No. 14/EE/EandM/20-21 (2nd Call)
Open Tender
Electrical Works
Item Rate
10 days
South Andaman
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
Exempted
28 Apr 2021
30 Mar 2021
8 Apr 2021
30 Mar 2021
8 Apr 2021
1 Apr 2021
31 Mar 2021 - 1 Apr 2021
Amount
Supplying, Installation, testing & commissioning of 2 zone microprocessor based conventional fire alaram panel; 2 x 16 character backlit LCD display (4 x 20 character optical); 64/128/256/512 events logging facility with real time clock and keypad; 2 wire communication facility VIA RS 485 PORT (For repeater panel),computer attachment with printer facility (VIA RS 232 PORT); BMS attachment; Lamp Test feature; complete with integral power supply and battery charger for sealed lead acid battery; potential free contacts for both fire and fault; switches to enable on board operation; LCD and LED indication for open, short circuit, isolate, fire in each zone; Maximum Nos, of detectors in each Zone is 25.Make:-Qutak, Model QT 02 QFP
Supplying, installation, testing & commissioning of manual call point, available for flush of surface mounting, suitable for majority of conventional fire alarm system, front protection glass cover, unbreakable glass ABS plastic body, 1 8-26 volt DC,30M A Alarm current, red colour, made of FR polymer, Brand:-Qutak, Model QT 371ABS etc as required.
Supplying, installation, testing & commissioning of conventional photoelectric smoke detector, low current draw, operates on 12 and 24 VDC systems, remote alarm test features, easy maintenance, remote LED option, approved to EN54-7: 2000(Amendment1) Brand :- System Sensor Model:- ECO 1003 etc as required.
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required a) 2 x 1.5 sq. mm
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required a) 20mm
PRIDE TECH ENGINEERING WORKS
MILESTONE ENGINEERING
M/s G K Construction
M/s Sai Electrical Works
NAVJEEVAN ENTERPRISES
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .