Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹13.1 LAccepted-AOC | L-1 | Accepted-AOC Lowest Bidder | |
| 2 | L-2₹19.9 L+₹4.0 L (25.0%)Rejected-Finance | L-2 | Rejected-Finance Other than lowest bidder | |
| 3 | L-3₹22.3 L+₹6.4 L (40.4%)Rejected-Finance | L-3 | Rejected-Finance Other than lowest bidder | |
| 4 | L-4₹22.6 L+₹6.7 L (42.1%)Rejected-Finance SIMBAL CAMP WARD NO 5 NEAR GURUDWARA SAHIB R S PURA DISTT JAMMU J K 1812104 | R S PURA | JAMMU | J K | 1812104 | L-4 | Rejected-Finance Other than lowest bidder | |
| 5 | L-5₹23.2 L+₹7.3 L (46.0%)Rejected-Finance | L-5 | Rejected-Finance Other than lowest bidder |
Tender Value
Refer Docs
EMD Value
₹60,000
Closing Date
7 May 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Jammu
GE Jammu c/o 56 APO Pin-900277
REPAIR AND MAINTENANCE OF COOLING APPLIANCES, SURBO VOLTAGE STABILIZER AND ALLIED WORKS AT BALIDAN STAMBH, SAINIK ARAM GRAH, SUNJUWAN UNDER GE JAMMU
2022_MES_517871_1
GEJC-07/2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AoR of GE Jammu
Please refer Tender Documents
9 documents required · 9 mandatory
₹500
GE Jammu
₹60,000
Yes
13 Jul 2022
12 Apr 2022
9 May 2022
12 Apr 2022
7 May 2022
25 Apr 2022
60 days
Amount
Material and labour for repair / maint to desert coolers complete with and including cleaning, scrapping / rubbing old rusted surface, filling cavities and painting with two coats of high quality aluminium paint externally and black paint to water storage tank internally with synthetic enamelled paints complete with replacement of necessary nut, bolts, rubber pads for fan motors and writing MES No / unit name complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in replacement of desert cooler fan motor 90 watt, 1400 RPM, 230 Volt, 50 Hz single phase conforming to ISI complete with fan blade and capacitor of sutitable size complete all as specified and as directed.
Supply and fixing in replacement of desert cooler submersible pumping set single phase 230 Volt, 50 Hz of 0.25 to 1.0 HP conforming to ISI complete with lead complete all as specified and as directed.
Supply and fixing in replacement of PVC accessories of desert cooler i.e. PVC pipe 20 mm dia heavy duty 2 metre approximate, PVC distributor 4 way with nut, bolts, PVC elbow-03 No's, mild steel clamps etc complete all as specified and as directed.
Supply and fixing in replacement of desert cooler fan motor blade of existing size made out from mild steel having duty complete with key bolt complete all as specified and as directed.
Supply and fixing in replacement of desert cooler side opening cover made out from heavy duty mild steel sheet and matching with the existing desert cooler body size complete with Khas Khas pads set of three peices complete all as specified and as directed.
Supply and fixing in replacement of desert cooler unserviceable / leakage body made out from heavy duty mild steel sheet bend to shape company manufacturer, complete with internal PVC accessories i.e. PVC elbow-03 No's, PVC distributor 4 way-01 No, PVC distribution pipe - 2 metre approximate, black painted internally, Aluminium painted externally complete with provision of necessary arrangement for fixing front cover and fan motor complete all as specified and as directed.
Supply and fixing in replacement cable PVC insulated and sheathed of size 1.5 Sqmm 3 core FRLS, 230 Volt, 50 Hz conforming to ISI complete all as specified and as directed.
Supply and fixing in replacement cable PVC insulated and sheathed of size 2.5 Sqmm 3 core FRLS, 230 volt, 50 Hz conforming to ISI complete all as specified and as directed.
Supply and fixing in replacement cable PVC insulated and sheathed of size 4.0 Sqmm 3 core FRLS, 230 volt, 50 Hz conforming to ISI complete all as specified and directed.
Supply and fixing in replacement of plug top 3 pin, 5 Amp, 230 Volt, 50 Hz complete all as specified and as directed.
Material and labour in replacement for fabrication of desert cooler stand made out from angle iron 40 X 40 X 6mm thick, bend to shape, welding as per site requirement fixing in brick / stone masonary wall complete with cemented work necessary rawl plug, nut, bolts etc complete all as specified and as directed.
Supply and fixing in replacement of PVC accessories of capacitor 2.5 MFD for desert cooler fan motor, 230 Volt 50 Hz complete all as specified and as directed.
Supply and fixing in replacement of unserviceable Khas Khas / Glass wool for desert cooler set of three pieces complete all as specified and as directed.
Repair / maint / servicing to refrigerator / deep freezer / water coolers / AC's of any capacity and model by replacing capillary tubing, gas chargings, rectification of leakage in capillary tubing / Chiller plant / water tanks, condensing coils, repair to wiring, flushing / cleaning, condensing / cooling coils / internal / external unit of split AC, greasing to blower motors, replacement of spare parts, fan belts and make refrigerator / deep freezer / water coolers / AC's in serviceable condition complete all as specified and as directed by Engineer-in-Charge. Note: - Spare / Gas charging shall be paid separately.
Charges for fixing in replacement of unserviceable sealed seamless welding compressor unit company manufacturer of any capacity for AC's complete with initial filling / charging of refrigerant gas to meet the requirement complete with vibration rubber pads four no's each nut, bolts etc and testing on full load all as specified and directed by Engineer-in-Charge. Note: - (i) Spare parts shall be measured and paid separately under respective items. (ii) Contractor shall be responsible for all replacement of failed compressor and shall be accompanied by certificate from the original compressor to the effect that said compressor has been repaired at their authorised service center. Further, a warranty of 12 months shall be provided on such replacement in writing.
Supply only sealed compressor unit seamless welding company manufacturer with filling of refrigerant gas conforming to ISI as under: -
For refrigerator 165 / 286 Litre capacity.
For refrigerator 290 / 320 Litre capacity.
For Deep Freezer 100 / 200 Litre capacity.
For Deep Freezer 300 / 400 Litre capacity.
For Water Cooler 40 / 80 Litre capacity.
For Water Cooler 60 / 120 Litre capacity.
Split / Window AC 1.5 Ton capacity.
Supply and fixing in replacement of unserviceable / burnt condensing fan motor 1/35 HP single phase 230 Volt 50 Hz complete with blade, fan belts for water cooler of capacity 40 / 80 Litre and 60 / 120 litre complete all as specified and as directed.
Supply and fixing in replacement of condensing fan motor 1/5 HP 1440 RPM single phase 230 Volt 50 Hz with double blade and shaft end with fan belts for windows AC / split AC conforming to ISI of capacity 1.5 / 2.0 ton complete with vibration parts etc complete all as specified and as directed.
Supply and charging refrigerant 134a/R-22 in sealed compressor unit of refrigerator / deep freezer / water coolers / AC's of any type and capacity after flushing the complete system with carbon tetrachloride (CTC) and vacuumise the complete system with vacuum pump and testing on full load including replacement of filter, strainer complete all as specified and as directed.
Supply and fixing in replacement of following spare parts for refrigerator / deep freezer / water coolers / AC's of any capacity: -
Starting relay
Overload protector
Thermostat switch
Defroz switch
Supply and fixing in replacement of following unserviceable spare parts of water cooler of any capacity: -
Starting capacitor 45 mfd
Running capacitor 60/120 mfd
Float valve PVC 15 mm dia with ball
Push cock chromium plated 15 mm with nipple 6'' long
Drain/Wash out flexible down pipe 40 mm dia
Water tank door gasket
Water drain tray of suitable size
Supply and fixing in replacement of unserviceable following spare parts of window / split AC unit of capacity 1.5 to 2.0 ton: -
Starting capacitor 36/40 mfd
Running capacitor 100/120 mfd
PCB of Split AC
Front Grill cover for window AC 1.5 Ton
Condensing fan motor double shaft
Supply and fixing in replacement of PVC flexible braided pipe of 20 mm dia for split AC water drain out complete all as specified and as directed.
Supply and fixing in replacement of outer split AC condensing unit complete for split AC 1.5 ton all as specified and directed.
Supply and fixing in replacement of inner unit of split AC complete with filters, blower motor etc for split AC 1.5 ton complete with all accessories all as specified and directed.
Supply and fixing in replacement of copper capillary tubing 5/8'' for AC connection / repair complete all as specified and as directed.
Supply and fixing in replacement of condensing unit of Refrigerator / Deep Freezer / water cooler of any capacity complete with cutting and brazzing work complete all as specified and as directed.
Supply and fixing in replacement of magnetic door gasket of refrigerator 165 to 310 Litres capacity complete all as specified and as directed.
Supply and fixing in replacement of freezer compartment (Chiller Unit) with dooe / cover of refrigerator 165 to 310 Litres capacity of any make complete all as specified and as directed.
Supply and fixing in replacement of chiller tray of approved quality / brand suitable for upto 310 Litres capacity of any make complete all as specified and as directed.
Supply and fixing in replacement of vegetable / fruit basket with lid of approved quality / brand suitable for upto 310 Litres capacity of any make complete all as specified and as directed.
Material and labour for preparation of old steel surface by using wire brush / emery paper etc and make the surface smooth and paint to the outer cover / external surface of water cooler with two coats of synthetic enamel paint and re-writing the MES NO etc to water cooler of any capacity complete all as specified and as directed.
Taking down old unserviceable copper / aluminium point wiring concealed / batten (light, fan, socket or power) complete including fixture and fittings such as switches, sockets, ceiling roses, bell push, bell electric, lamp holder, bulk head fitting, pendants, regulators, sockets, light fitting and any type of switch board wooden / iron, round block etc removing materials to store for keeping in safe custody or for taking credit and making good disturbed surfaces of walls, floors etc complete all as specified and as directed. Note: - Credit for above items should be made as per conditions separately.
Material and labour for point wiring for one light / fan / call bell point controlled by one 5 Amp switch with 1.5 Sqmm single core multistranded copper conductor FRLS, PVC insulated (unsheathed) heavy duty cable including continuous earth wire of size 1.5 Sqmm copper conductor multistranded FRLS, PVC insulated (unsheathed) drawn into existing concealed PVC rigid / steel conduit and into existing CI / pressed steel terminal boxes including 3.00mm thick hylam brand IS-2036 marked, laminated sheet cover for mounting switches, sockets, fan regulators etc complete all as specified and as directed. Note: - (a) Wiring shall be done by using proper colour coding. (b) Earth wire shall be of green colour. (c) On RCC roof / ceiling PVC conduit shall be provided on surface with proper fixing clamps all as directed by Engineer-in-Charge.
Description all as per Serial item No 38.00 here-in-before but for one 5 pin socket outlet 5 amps on the same board complete all as specified and as directed.
Description all as per Serial item No 38.00 here-in-before but for one 5 pin socket outlet, 5 amps, independent complete all as specified and as directed.
Description all as per Serial item No 38.00 here-in-before but for one 5 pin socket outlet 15 Amps on independent board with cables 2.5 Sqmm size complete all as specified and as directed.
Material and labour for replacement of distribution board sheet steel powder coated for MCB with copper bus bar and neutral link earthing stud SPN 12 way 240 Volts double door complete all as specified and as directed by Engineer-in-Charge. Note: - Distribution board and MCB's should be of same make.
Material and labour for replacement of distribution board sheet steel powder coated for MCB with copper bus bar and neutral link earthing stud SPN 8 way 240 Volts double door complete all as specified and as directed by Engineer-in-Charge. Note: - Distribution board and MCB's should be of same make.
Material and labour for replacement of distribution board sheet steel powder coated for MCB with copper bus bar and neutral link earthing stud SPN 4 way 240 Volts double door complete all as specified and as directed by Engineer-in-Charge. Note: - Distribution board and MCB's should be of same make.
Supply and fixing in replacement 240 V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 5 to 32 Amp, in the MCB DB complete with connection, testing and commissioning complete all as specified and as directed.
Supply and fixing in replacement 240 V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 40 Amp, in the MCB DB complete with connection, testing and commissioning complete all as specified and as directed.
Supply and fixing in replacement of SPN 32 Amp rating 240 V, 10 KA 'C' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection, testing and commissioning complete all as specified and as directed.
Supply and fixing in replacement of SPN 40 to 63 Amp rating 240 V, 10 KA 'B' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection, testing and commissioning complete all as specified and as directed.
Supply and fixing in replacement of 415 V 10KA 'B' curve TPN 40 to 125 Amp miniature circuit breaker (MCB) of following poles and current carrying capacity in the DB complete with connection, testing and commissioning complete all as specified and as directed.
Supply and fixing in replacement for switch piano, flush type single pole one way 5 Amp, 240 Volts complete all as specified and as directed.
Supply and fixing in replacement for switch piano, flush type single pole one way 15 Amps, 240 Volts complete all as specified and as directed.
Supply and fixing in replacement for socket outlet 2 in 1, 3 pin, 5 A complete all as specified and as directed.
Supply and fixing in replacement for socket outlet 5 pin, 15 Amp, flush type, 240 Volts, 6 pin flush type complete all as specified and as directed.
Supply and fixing in replacement for switch socket outlet combined 5 pin 5 amp flush type, 240 Volts complete all as specified and as directed.
Supply and fixing in replacement for switch socket outlet combined 2 in 1, 3 pin 5 amp and 15 amp flush type, 240 Volts complete all as specified and as directed.
Supply and fixing in replacement for bell push, flush type single pole, 5 Amp, 240 Volts complete all as specified and directed.
Supply and fixing in replacement for ceiling rose 3 terminal surface type complete all as specified and as directed.
Material and labour in replacement for sub main wiring with proper colour coding, insulated, unsheathed, multistranded, copper conductor FRLS, cable of 2 run 6 Sqmm for phase and neutral and one run of 4.0 Sqmm for earth wire unsheathed, multistranded, copper conductor FRLS, drawn through the existing rigid PVC concealed conduit fixed on wall. Two runs of cable for phase / neutral and one run of cable for earth will be measured and paid as one unit length complete all as specified and as directed. Note: - Wiring shall be done in proper colour coding.
Supply and fixing in replacement of sheet metal enclosure with 3 pin earth plug and socket complete with single pole MCB of 32 Amps, 240 Volts single phase complete all as specified and as directed.
Supply and fixing in replacement of 1100 Volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one 10 Sqmm twin core stranded conductor cable flat or circular complete all as specified and as directed.
Supply and installation for replacement of automatic voltage stabilizer with back boost relay working range 90 to 290 Volt at 230 Volt of capacity 5 KVA complete all as specified and as directed.
Supply and installation for replacement of automatic voltage stabilizer with back boost relay working range 90 to 290 Volt at 230 Volt of capacity 3 KVA complete all as specified and as directed.
Supply and installation for replacement of automatic voltage stabilizer with back boost relay working range 90 to 290 Volt at 230 Volt of capacity 2 KVA complete all as specified and as directed.
Supply and installation for replacement of automatic voltage stabiliser with back boost relay working range 90 to 290 Volt at 230 Volt of capacity 1 KVA complete all as specified and as directed.
Labour for disconnecting all incoming / outgoing electric connection carefully of fully automatic servo voltage stabilizer having capacity 30 to 200 KVA and transport to workshop for repair / servicing and including dismantling top cover of stabilizer and taking out the coil, drain out the transformer oil and refilling after dehydration of transformer oil, cleaning internally, including replacement of unserviceable body nut, bolts, washers, top gasket of cork sheet 6mm thick, replacement of internal circuit wiring if any suitable size of copper wire and painting with heat resistant smoke grey / as per existing colour synthetic enamelled paint including preparation of old rusted surfaces and writing MES NO, SM MES No, capacity, Ser No, Location etc and reinstallation / connecting electric connection with replacement of proper size aluminium lugs and testing on full load at site complete all as specified and as directed. Note: - (a) Spare parts shall be measured and paid separately. (b) Rotor for replacement of spare parts are deemed to be included in above jobs.
Supply and fixing in replacement synchronous motor single phase 230 Volt suitable for servo voltage stabilizer having capacity 30 to 200 KVA complete all as specified and as directed.
Supply and fixing in replacement PCB suitable for servo voltage stabilizer having capacity 30 to 200 KVA complete all as specified and as directed.
Supply and fixing in replacement dimmer motor suitable for servo voltage stabilizer capacity 30 to 200 KVA complete all as specified and as directed.
Supply and fixing in replacement copper dimmer suitable for servo voltage stabilizer capacity 30 to 200 KVA complete all as specified and as directed.
Supply and fixing in replacement toggle On / Off switches for stabilizer capacity 30 to 200 KVA complete all as specified and as directed.
Supply and fixing in replacement Volt meter 0-500 Amp, 96mm Square type, 3 phase, 230 Volt 50 Hz complete all as specified and as directed.
Supply and fixing in replacement Ampere meter 0-400 Amp, 96mm Square type, 3 phase, 230 Volt 50 Hz with CT of suitable ratio complete all as specified and as directed.
Supply and fixing in replacement gun metal gate or glove valve 20 mm for drain out of oil complete all as specified and as directed.
Supply and fixing in replacement unserviceable brass / gun metal stud bush suitable for 30 to 200 KVA complete with connecting rod of suitable length and dia with necessary nut, bolt, washer, bushing packing to prevent the leakage from bushes and necessary connection complete all as specified and as directed.
Dehydration of Transformer oil and dielectric strength of oil achieved not to be less than 42 KV at 2.4 mm gap complete all as specified and as directed.
Supply and filling of new transformer oil for top up upto automatic servo voltage stabilizer including heating and dielectric strength not to be less than 60 KV complete all as specified and as directed.
Taking out main coil of voltage stabilizer 30 to 200 KVA for repair / rewinding with super enamelled copper winding wire of existing gauge including PVC insulated sheet sleeve, varnishing etc all as required and refixing to the stabilizer after testing all as required at site or directed by Engineer-in-Charge.
Supply and fixing in replacement of ground burial 3 watt light with transparent tempered glass diffuser with working voltage 90 V - 260 V AC complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in replacement of slim flood light 100 watt warm yellow including in-built surge protection as per requirement LED flood light fittings along with IP-65 protection all as specified and as directed.
Supply and fixing in replacement of slim flood light 200 watt warm yellow including in-built surge protection as per requirement LED flood light fittings along with IP-65 protection all as specified and as directed.
Supply and fixing in replacement of XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured electric power cable (heavy duty) 1100 Volt grade with stranded aluminium conductor of size 25 Sqmm 3½ core complete all as specified and as directed.
Supply and fixing in replacement of XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured electric power cable (heavy duty) 1100 Volt grade with stranded aluminium conductor of size 10 Sqmm 2 core complete all as specified and as directed.
Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre deep for foundations of poles / stays / cable etc. and getting out in soft / loose soil complete all as specified and as directed by Engineer-in-Charge.
Returning, filling in, earth including spreading, levelling, watering and well ramming in layers each not exceeding 25 cm thick each layer complete all as specified and as directed.
Removing of surplus soil to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and as directed by Engineer-in-Charge.
Material and labour for sand cushioning with a layer of fine sand (sand for plastering) 8 cm thick before laying of cable and 15 cm thick after laying of cable in trenches and ducts in installation complete all as specified and as directed.
Supply and laying including taking out old one well burnt old size sub class 'B' bricks laid flat with width equal to length of brick perpendicular to the direction of cable, adjacent / abutting each other complete all as specified and as directed by Engineer-in-Charge in trenches over the cable for protection.
NOTE NO 1: - Samples of materials as approved will be kept in GE's sample room. NOTE NO 2: - All fittings and fixtures mentioned above will be fixed to the satisfaction of Engr-in-Charge and GE. NOTE NO 3: - Warranty certificate to the Engineer-in-Charge where ever applicable shall be submitted by the Contractor at the time of fittings.
M/S Shiv Enterprises
G R CONSTRUCTIONS
M/s Sahib Construction and engineers
M/s. Aggarwal Engineers
Prakash Trading Corporation
PAWAN KUMAR GOVT. CONTRACTORS
Bidder Name
Prakash Trading Corporation
G R CONSTRUCTIONS
Sarbat Construction Co
M/S Shiv Enterprises
M/s. Aggarwal Engineers
M/s Sahib Construction and engineers
PAWAN KUMAR GOVT. CONTRACTORS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .