Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance DOOR NO 31 T S NO 5 2 LAKE VIEW BUILDING VETTRI NAGAR WATER CANAL ROAD KOLATHUR CHENNAI TAMIL NADU 600099 | CHENNAI | TAMIL NADU | 600099 | Admitted-Finance |
| 2 | Admitted-Finance 146 CP COLONY 7 NO CHOURAHA KALPANA NAGAR MORAR GWALIOR 474006 | GWALIOR | MADHYA PRADESH | 474006 | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
| 5 | Admitted-Finance | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹19,770
Closing Date
14 Feb 2020, 6:00 pmClosed
SM (Engg.-E), AAI DABH Airport, Indore.
O/o APD, AAI DABH Airport, Indore.
External Electrical works for Security Vetting of International Cargo at AAICLAS Indore. SH- Provision of Street Light and Boom Barrier
2020_AAI_41657_1
AAI/ID/SM (E-E)/NIT-15/2019-20
Open Tender
Electrical Works
Works
90 days
Indore
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,180
Airports Authority of India
₹19,770
28 Feb 2020
7 Feb 2020
19 Feb 2020
7 Feb 2020
14 Feb 2020
7 Feb 2020
7 Feb 2020 - 12 Feb 2020
Amount
Supply, installation, testing and commissioning of automatic electrical boom barrier of 4 mtr, suitable for operating at 230 V +/- 5%, 50 Hz +/-5%, along with a pair of photo cells, sensors, push button, control panel etc. as required. The motor used shall be suitable of continuous operation. The boom shall be of aluminum or any superior material,with retro reflective warning red strips, with rubber pad for safety. The opening /closing time shall be not more than 5 s for 4 mtr barrier . The IP rating of the control unit shall not be less than IP 54. Suitable anti -corrosion treatment shall be done to the control unit enclosure system operating temperature shall be from - 10°C to +55°C shall have adjustable speed, mechanical lock. System shall be provided with open / close electronic limit switch. Installation shall include the works such as foundation for the system, excavation for the same, interconnections,which are part of the complete system.
Providing , laying and fixing following dia G.I pipe ( medium class) in ground complete with G.I fittings including trenching ( 75 cm deep) and refilling etc. as required. 50 mm dia
Excavation of the trench in bitumen road suitable for laying GI pipe of dia 75 cm including getting out the excavated soil and refilling the excavated soil and making good the bitumen road with cement concrete complete as required.
Supply of maximum 90W LED Street light fitting with minimum output of 10800 lumens suitable for 160-270V, AC ,50Hz, PF>0.95.Luminaire should have pressure die cast Alminium LM6 housing,Luminaire should have dedicated street light secondary optics/lens for better uniformity & spacing with surge protection system. Luminaire should have Air Vents in housing for proper thermal management. Min IP protection should be IP65. System Power consumption (Including Driver Losses) should not exceed 90W, complete with all accessories as required. The fixtures should comply LM79 and LM 80 and other BEE/BIS guidelines/code for LED luminaries. The fitting should have manufacturers trade mark/name engraved/embrossing on die cast housing of fitting.The agency has to submit unconditional guarantee for 5 years in writing for LED fittings from original manufacturers.
Supply of 9 Mtr Octagonal Street light pole along with foundation Bolts & 1Mtr Bracket.With top Dia 70 mm, Bottom Dia 130 mm , Sheet Thickness 3mm Base Plate Dimensions 200X200X16 mm complete as required(Make : Bajaj or equivalent approved makes)
ITC of 90W LED fittings on existing tubular Poles of height up to 9 mtr. including provision of 1.5 sqmm ISI Marked , FR PVC insulated, single core copper conductor connecting wires and mounting bracket complete as required.
ITC of Octagonal pole of 9Mtr length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required. Above 8.0 metre and upto 10.0 metre
Supply and fixing of loop in / loop out junction box with protection,made out of non metallic,chemical resistant,fire retardent material with 4 way Bakelite connector suitable to accommodate min.3.5 core, 16 sqmm cable alongwith 6 Amp MCB,locking arrangement complete in all respect as required on the GI pole with suitable size MS clamp including cable & wire termination(Make:Hensel KF166G or Equivalent approved make).
Supplying and embedding following dia G.I. pipe (medium class) in pole collar/ foundation (during casting) for cable entry including bending the pipe to the required shape complete as required. 32 mm dia
Laying of one number PVC insulated and PVC sheathed /XLPE power cable of following size direct in ground including excavation, sand cushioning , protective covering and refilling the trench etc as required. Upto 35 sq. mm
Laying of one number PVC insulated and PVC sheathed /XLPE power cable of 1.1 KV grade of following size in the existing RCC/HUME /STONEWARE/ METAL pipe as required . Upto 35 sq. mm
surbhi association
Manish Electricals
N L Neema
Magtech Security Systems Pvt Ltd
Techno Electricals
stage.html
html • 0.04 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .