Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.8 CrAccepted-AOC NO 9 DR SEVALIYE SHIVAJI GANESAN NAGAR 3RD STREET DINDIGUL 624 001 | DINDIGUL | DINDIGUL | TAMIL NADU | 624001 | ₹16.8 Cr | L1 | Accepted-AOC Lowest quoted bidder. accepted Amount after deducting schedule of credit |
| 2 | L2₹17.5 CrRejected-Finance | ₹17.5 Cr | L2 | Rejected-Finance Other than lowest bidder |
| 3 | L3₹17.8 CrRejected-Finance | ₹17.8 Cr | L3 | Rejected-Finance Other than lowest bidder |
| 4 | L4₹18.4 CrRejected-Finance | ₹18.4 Cr | L4 | Rejected-Finance Other than lowest bidder |
| 5 | L5₹22.6 CrRejected-Finance | ₹22.6 Cr | L5 | Rejected-Finance Other than lowest bidder |
Tender Value
₹16.3 Cr
EMD Value
₹11.4 L
Closing Date
12 Mar 2020, 6:00 pmClosed
CE NAVY Visakhapatnam
Chief Engineer Navy Military Engineer Services Station Road Visakhapatnam 530004
PROVISION OF DEFICIENT DSC MARRIED ACCOMMADATION AT INS KATTABOMMAN TIRUNELVELI
2019_MES_283501_2
CE(NAVY)/VIZ/TVL/TOKEN No 30 OF 2018-19
Open Tender
Civil Works
730 days
Tirunelveli
As per NIT
8 documents required · 8 mandatory
₹3,000
Garrison Engineer Tirunelveli
₹11.4 L
Yes
16 May 2020
22 Jan 2020
14 Mar 2020
22 Jan 2020
12 Mar 2020
27 Feb 2020
Amount
Schedule "A" Part – I to Schedule "A" Part – XI: NOTE: Schedule "A" Part – I to Part – XI are prepriced by MES. Bidders shall insert their Lumpsum amount in Green coloured field
Lumpsum price worked out by the contractor for "Buildings and Structures", for the Lumpsum price of Rs. 8,03,62,000.00 inserted by MES as listed in Schedule "A" Part – I on Serial Page No. 36[A]
Lumpsum price worked out by the contractor for " [SITE CLEARANCE , EARTHWORK AND EXCAVATION]", for the Lumpsum price of Rs. 26,32,512.38 inserted by MES as listed in Schedule "A" Part – II on Serial Page No. 39[R]
Lumpsum price worked out by the contractor for " INTERNAL WATER SUPPLY", for the Lumpsum price of Rs. 3,52,048.00 inserted by MES as listed in Schedule "A" Part – III on Serial Page No. 41[R]
Lumpsum price worked out by the contractor for "[INTERNAL ELECTRIC SUPPLY ]", for the Lumpsum price of Rs. 17,18,878.10 inserted by MES as listed in Schedule "A" Part – IV on Serial Page No. 45[R]
Lumpsum price worked out by the contractor for "[EXTERNAL WATER SUPPLY]", for the Lumpsum price of Rs. 21,11,074.60 inserted by MES as listed in Schedule "A" Part – V on Serial Page No. 48[R]
Lumpsum price worked out by the contractor for " [EXTERNAL ELECTRIC SUPPLY]", for the Lumpsum price of Rs. 7,69,916.86 inserted by MES as listed in Schedule "A" Part – VI on Serial Page No.54[R]
Lumpsum price worked out by the contractor for "[ROAD, PATH AND CULVERT ] ", for the Lumpsum price of Rs. 37,25,903.80 inserted by MES as listed in Schedule "A" Part – VII on Serial Page No.58
Lumpsum price worked out by the contractor for " [SEWAGE DISPOSAL]", for the Lumpsum price of Rs.12,33,195.20 inserted by MES as listed in Schedule "A" Part – VIII on Serial Page No.61[R]
Lumpsum price worked out by the contractor for "[AREA DRAINAGE]", for the Lumpsum price of Rs.23,33,563.90 inserted by MES as listed in Schedule "A" Part – IX on Serial Page No. 62
Lumpsum price worked out by the contractor for "[CHAIN LINK FENCING]", for the Lumpsum price of Rs.1,35,453.92 inserted by MES as listed in Schedule "A" Part – X on Serial Page No. 66[R]
Schedule "A" Part - XI MISCELLANEOUS ITEMS FOR INTERNAL WATER SUPPLY, INTERNAL ELECTRIC SUPPLY, EXTERNAL WATER SUPPLY, EXTERNAL ELECTRIC SUPPLY, ROAD, PATH AND CULVERT , SEWAGE DISPOSAL (TO BE QUOTED BY THE TENDERER)
INTERNAL WATER SUPPLY
PVC connecting pipe 18" long with brass adopters for Hot and cold water and connecting up with complete for 15 lts caoacity Geysers complete all as specified and directed.
Water heater of capacity 15 lrs, 5 star rated with rated wattage of 2000 watts suitable for operation at 230V AC and rated pressure of 0.8 bars,inner tank shall be made of vitereous Enamel/Glass lined steel tank/polymer protection coated tank of 1.88 to 2mm thickness with 250-400 microns thickness of enamel coating all as specifed and directed
INTERNAL ELECTRIC SUPPLY
Concealed Submain wiring in with PVC insulated FRLS multistranded copper conductor cable unsheathed for circuit along with earth wire including PVC conduit of 25mm dia with accessories of cable size 4 runs 10.0 Sqmm and 1 runs of 10.0 Sqmm complete all as specified and as directed.
Note for Sl Item No.17.00 :- 4 runs of 10.0 Sqmm , 1 run of 10.0 Sqmm cable incl 25 mm dia PVC conduit shall be messured and paid as one unit
Energy efficient LED light fitting with tube 20 watt or minimum lumen output is not less than 2000 lumens, 230 V, including drive, surface mounted LED batten type with extruded aluminium/ CRCA housing and robust construction with necessary acrylic cover as diffuser complete with mounting bracket etc including connecting up with twin core twisted flexible copper conductor cable with suitable size all as specified. Make : Havells cat No. ENDURALINEAR NEO BS20W LED 840 SPCWH or equivalent Philips/Bajaj/ GE/Wipro/Surya
Energy efficient LED ceiling light fitting 10 watt, minimum 1000 lumnes output including drive, white powder coated polycarbonate housing and pressure die cast heat sink having high efficency, 230V surface mounted with necessary diffuser complete with mounting bracket etc including connecting up with twin core twisted flexible copper conductor cable with suitable size all as specified. Make Havells cat No. INTEGRO NEO SURFACED LS 10W LED 8575 or equivalent Philips/ Bajaj/ / GE/ Wipro/ Surya.
Energy efficient LED mirror light fitting 10 watt 6500 lumens, surface/wall mounted LED batten with aluminum housing and integrated driver with necessary diffuser complete with mounting bracket etc, 230V including connecting up with twin core twisted flexible copper conductor cable with suitable size all as specified. Make Havells cat No. LUMLINE PLUS BS 10 W LED 865 SPCSS or equivalent Philips/ Bajaj/ / GE/ Wipro/ Surya.
LED security light fitting with tube 25W or minimum lumen output is not less than 2500 lumens, New generation energy saving & environmental frindly long life versatile pressure die cast aluminium luminiare with mid power LEDs as sourced and HF electronic driver pre wired with 1.5 Sq mm copper conductor cable upto connector including 2 Mtr long GI tubing Medium grade 32 mm dia bend to shape fixing on wall with suitable MS brackets complete all as specified and as directed. Make : Havells cat No. ENDURA PEARL SL 25W LED 757SASYTOPC or equivalent Philips/Bajaj/ GE/Wipro/Surya
Ceiling fans AC single phase 230 V of size 1200 mm sweep with complete set with fixtures, 5 star rating, metallic body complete all as specefied and directed. Make: Havells/Bajaj/CG/Orient
Exhaust fan 200 mm sweep or nearest size, 900 RPM, metalic body (Heavy duty), complete with louvers suitable for operation on 230 V AC, 50 Hz AC supply fixed on wall making opening, fixing and making good the disturbed surfaces etc complete all as specified and as directed Make : Havells/Bajaj/CG/Orient NOTE FOR SL ITEM NOS 22&23 : The connecting wire for ceiling and exhaust fans to regulator shall be with multistranded 3 core, 1.5 Sqmm flexible copper conductor cable. The rate quoted against the item shall deemed to be included for the same.
VTPN MCCB DB 4 way 415V, 50HZ double door, IP 43 protection with 200A rated bus bar for provision MCCB FP 200 AMP 16 KA as incommer and outgoing circuits complete, flush mounting type, fill empty with blanks making good the disturbed area as per existing surface completed al as specified and directed.
VTPN DB 4 way 415V, 50HZ double door, IP 43 protection with 200A rated bus bar for provision MCCB FP 160 AMP 16 KA as incommer and outgoing circuits complete, flush mounting type, fill empty with blanks making good the disturbed area as per existing surface completed al as specified and directed.
MCCB, Four pole and neutral, 415 Volts, adjustable type, 160 Amps with breaking capacity 16 KA complete all as specified and directed
MCCB, Four pole and neutral, 415 Volts, adjustable type, 200 Amps with breaking capacity 16 KA complete all as specified and directed
Earthing complete with GI earth plate electrode 60cmX60cmX6mm thick, burried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to GI earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No-3 of SSR Part-I connected to earthing test point all as specified or indicated including excavation and earth work in any type soil, PCC 1:2:4 type B-2 as in pit, 20mm dia GI pipe medium grade for watering pipe, 15mm bore GI medium grade earth lead protection pipe connected upto DBs, and suitable C.I top cover with handle, funnel, strainer, charcoal and testing on completion all as specified and directed. Note- Rate quoted deemed to be included excavation and earth work in any type of soil with PCC type B2 in pad and pit complete all as specefied and directed. (For TPN 4 way DB's)
Single phase temper proof electronic proof energy meter of accuracy class 1.0 and current rating 5 to 20 A with backlite LCD display, 240 V, 50 HZ with pilfer proof meter box made of Engg platic FR grade all as specified and directed.
EXTERNAL WATER SUPPLY
Supply and lay in trenches Centrifugally cast (SPUN) ductile iron pressure pipe of 100 mm nominal dia with socket and spigot ends conforming IS : 8329/2000, classification K9, ISI marked, suitable for push and joint with rubber gasket confirming IS 5382 and cement mortar lining inside and zinc coating with compatible butminious paint/synthetic resin outside complete all as specified and as directed.
Specials for centrifugal cast (SPUN) ductile iron up to 100mm such as bends( any type, radius and angle) Tapers any type, straight, bend, increasing, decreasing or double socket etc Tee pieces, single branch, 'Y' junction, double branch, cross ( all sockets or socket and spigot collars, caps and plugs complete all as per IS 9523-2000 all as specified and as directed.
Pig lead joint fixing of DI pipes including necessary required arrangements all as specified and directed.
Supply and fix flanged type Sulice Valve of class PN 1.6 -I st marked confirming to IS: 14846-2000 complete of size 100mm dia complete including steel spindle with head, iron wheel gland with gland packing etc including rubber gasket complete all as specified.
All as per Serial item No.34.00 above but 80 mm dia
Cast Iron Reflux Valve (non returnable), with by-pass Arrangement with 15 mm gate valve 100 mm (4”) dia
Cast Iron Reflux Valve (non returnable), with by-pass Arrangement with 15 mm gate valve 65mm dia
Cast Iron Foot Valve conforming to IS 4038 100 mm (4”) dia
Cast Iron Air release Valves with single air Outlets, conforming to IS 14845 of size 50 mm dia bore and fixing up in Cast Iron Water supply mains of size 25mm dia.
Supply, installation, commissioning and testing , Monoblock Pumping set, electric driven of capacity 10 WHP , 415 volts ,50HZs , head of pump 30 Mtrs, delivery 12.2 LPS with suction 100 mm dia and delivery 100 mm dia complete with the pump having brass Impellers with air vent brass nozzles, the complete pump set shall be mounted on MC Channel appropriate size and thickness as recommended by manufacturer desgin complete all as specified. Make : Crompton Greves MBS 10.2 pipe size suction/delivery-100X100 mm head range 30 mtr / TECHNO commercial equivelent of JOYTI/Kirloskar
Construction of Valve chamber of size 1.0 x 1.0 x 1.0m (internal dimentions) including excavation of earth work in any type of soil, 75 mm thick PCC M 10 as in foundation , made out of 230 mm thick brick work in cement mortar 1 :6 with 15mm thick plastering in cement mortar 1:4 internally complete and upto 150mm below ground level for external faces with 100mm thick plain cement concrete M 10 using 20mm graded aggregate as in coping, cover frame made up of ISA 40x40x6mm and 3.15mm thick MS sheet as cover with two Nos of hinges and one No handle made out of MS round bar 10mm dia with neccssary locking arrangement including finishing the exposed steel sufraces with two coats of synthetic enamel paint over a coat of red oxide primer and two coats of white wash on plastered surfaces complete all as specified.
Construction of Valve chamber of size 750 x 750 x 750 mm (internal dimentions) including excavation of earth work in any type of soil,100mm thick PCC M 7.5 as in foundation , made out of 230mm thick brick work in cement mortar 1 :6 with 15mm thick plastering in cement mortar 1:4 internally complete and upto 150mm below ground level for external faces with 100mm thick plain cement concrete M 10 using 20mm graded aggregate as in coping, cover frame made up of ISA 50x50x6mm and 3.15mm thick MS sheet as cover with two Nos of hinges and one No handle made out of MS round bar 10mm dia with neccssary locking arrangement including finishing the exposed steel sufraces with two coats of synthetic enamel paint over a coat of red oxide primer and two coats of white wash on plastered surfaces complete all as specified.
Supply & Install, testing & commissioning of Sodium hypo chloride , electronic automatic heavy dosing equipment 230 volts , AC , 50 HZ incl spares maintained chlorine 2 ppm at source and 0.2 ppm at user end for reqd qty of water along with the 100 Ltrs Hypo chloride eqpt complete MAKE : Aqua Chloro Agency
Supply and fix double compression copper stain less steel gland for fixing armoured cable in panel of size 3.5 core 95 sq mm to 120 sqmm
Earthing complete with galvanised steel earth plate electrode 600x600x6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to using galvanised iron earth stip 32x6 mm as earthing lead by means of bolts and nuts check nuts and washers of galvanised iron or steel all as specified and shown in electrical plate No 3 of SSR Part I including Charcoal and rock salt with necessary excavation and earth work in any type of soil PCC 1:3:6 type C1 chamber with CI Cover of 10 mm thick with MS rod 6 mm dia 150 mm long reinforcement, watering funnel with 15 mm dia light grade for watering and for protection of earth electrode 50 mm dia GI Pipe all a specified and directed and tested on completion.
(A) Alternator :- Standard design alternator rated at 30 KVA net output at site after considering derating as per site conditions at 0.8 (lag) power factor AC, 3 - phase 4 - wire 415 volts 50 Hz, 1500 RPM, self exicited self regulated screen protected drip proof IP 23 enclosure brush less design with winding In pole faces, insulating class 'H' and voltage regulation of ± 1% at rated voltage from no load to full load. The alternator shall be confirming" to BS 2613/5000 and shall be in position to generate supply with frequency regulation with in ± 1% tolerace. The alternator will be suitable for tropical climate and shall generally confirm to BS - 2613/5000/ IS - 4722.
(B) Diesel Engine: - Adequate capacity Diesel engine suitable for 30 KVA coupled drive independently above alternator and after considering derating as per site conditons after generating and reducing power consumed by accessories, directly coupled through flexible type coupling multi cylinder multi stroke direct injection, cold starting 1500 RPM, as per relevant ISI/BS - 5514 with an overload capacity of 10% for one hour in 12 hours continuous running complete with standard accessories all as specified and required for safe handling and operation salient features of accessories shall be as under:- (i) Fly wheel with housing (ii) Cooling system :- Mounted radiator with fan & belts. (iii) Cooling Water pump: - Centrifugal type belt driven.
(C) Exhaust System :- Exhaust System complete with exhaust piping of suitable dia as per manufacture standard with MS pipe light grade upto and away two meters height from top of enclosure including necessary angle iron frame supports from' floor to the bottom of exhaust pipe from the enclosure covered with mineral wool of thickness 50mm rapped with chicken wire mesh of size 2.25mm and aluminium sheet of 24 SWG to be complete with in the enclosure for safe exhaust without transforming vibration to the wall of the enclosure. i) Exhaust gas turbo charger type ii) Exhaust manifold Silencer; Residential type
(D) Fuel System :- Fuel injection system with fuel Injectors, fuel injection solenoid switch/ nozzles/ governer mechanical type capable for 1% speed /frequecy regulation. i) Fuel filters ii) Fuel hoses v) Lub oil System :- i) Lubricating oil filter ii) Lubricating oil pump vi) Air Intake System iv) Air intake Manifold v) Air cleaner dry type vii) Governer :- Electronic Governer viii) Starting System :- Electric Self starter with maintenace free batteries lncludlng battery charging alternator.
(E) Batteries:- 1 No Maintenance free Batteries of 12 VOLT 75 AH capacity complete with copper conductor multlstranded leads of suitable length from self starter to the battery terminals complete with initial charge and initial fill of electrolyte all as specified. (F) Handling and operation : Salient features of accessories shall be as under: i) Starter gear ring ii) Start and stop push button iii) Ignition key / Switch iv) Radiator with blower fan v) Corrosion inhibitor coolant vi) Paper element filters for fuel, lub oil and by pass. vii) Eelctronic governer controlled direct fuel injection system viii) Fly wheel housing and fly wheel.
(G) Generator Monitoring Panel : Comprising of following : (a) Gen set controller connected micro process integrated Generator set monitoring metering, governing, protection and control system with built in torque matched volts/Hz/overload controller with necessary hardware / software etc. (b) Engine protection for low lub oil pressure, high coolant temperature (alarm & shutdown) (c) Alternator protection parameters like under voltage, over current, under frequency, over frequency ( alarm & shut down) (d) Relay drivers for remote annunciations (e) Cyclic cranking (f) Auto/manual start/ stop (g) Alternator trim adjustment from the front key pad (h) Operates within a temperature range 0- 50°C and humidity upto 95% (j) Remote monitoring capabilty through separate Interface modules
(k) Genset metering parameters like lube oil pressure, coolant temperature, engine speed(rpm), run hours, DC voltage, 3 phase volts and 3 phase amperes, frequency, KW, KVA, power factor (l) Safety Controls : - Engine low lube oil pressure, high water temparature and over speeding of engine. (m) Coupling arrngement : - Flexible coupling, fly wheel to suit flexiable coupling fly wheel houslnq. (n) Accessories :- AVM Pads built or separtely mounted to manufacturer base frames. (o) Base Frame : - Made out of ISMC 250 of sturdy design made of MS channel with necessary reinforcement and predetermined holes.
(H) Fuel Tank :- Daily service fuel tank of capacity suitable for continuous 12 hours run made out of 3 mm thick (Heat Retradant) sheet top and bottom with caliberated level indicating arrangement, stop cock, drain plug, fuel pump of suitable capacity and connected pipe line should be Installed with in built tank inside the acoustic enclosure is inclusive of the cost of DG set and is as per manufacture design. (q) Deliverables. Confirms the norms established by CPCB. (J) AMF PANEL:- Auto Main Failure (AMF) panel made out of 2 mm CRCA sheet,powder coated of conforming to IS 8623 totally enclosed dust and vermin proof with front and rear openings of 415 Volts, 3 Phase, 4 Wire, AC 50 Hz having copper bus bar capacity required to carry current at 110% load of 30 KVA DG set with three phase and half neutral colour coded, pre-wired with copper flexible cable,d be all as specified with the following accessories, control cable from Gen set to AMF panel :- i) MCCB 4 pole 63 Amps 25 KA with Electical contactor 100 Amps 4 pole for alternator (DG supply) - 01 No
ii) MCCB 4 pole 63 Amps 25 KA with Electical contactor 100 Amps 4 pole for alternator (Main supply) - 01 No
All controls indicators and standard fittings as follows : i) Multi functional digital meter for KWH,KVA,KW,Amps,Volts,Frequency and power factor etc - 01 No Functions: ii) Supply failure timer and restroration - 1 No iii) 3 impulse automatic engine start & stop logic Announceation with indicators LED lamps for a) Protective over loading relay - 1 No b) Low Lub oil pressure, high water temperature, Engine over speed, battery low voltage, under voltage -1 No c) Earth fault relay- 1No
K) Acoustic enclosure: Enclosure Is free standing floor mounted factory built and moduiar in construction to facilitate easy assembly at work site and will be drop over housing type. It will consist of acoustically treated panel housed In sheet steel will provide easy access for maintenance, repairs and operation. The enclosure is custom built to suit conditions, with the following features:- i) Custom built product for various equipments, with ensure the optimum performance without duration. ii) Rugged in construction maintenance free and modular designs which facilitate easy at site. iii) 2 mm thick CRCA sheets to be used for enclosure panel to ensure longer life against weathering action. High quality acoustic insulation materials to be used as per IS 8183 for maximum sound absorption. Acoustic layers are supported by perforated sheets iv) Sheet metal components of the enclosure should undergo various stages of surface treatment prior to painting which leads to be bette life of the enclosure against weathering action.
v) Special paint treatment with pure polyester powder / epoxy to be provided for better weather resistance. vi) Well designed ventilation system to be provided to pump up the heat in the chamber efficientlv. vii) For effective acoustic / weather sealing a special type weather seallnq qaskets, new frame rubber qaskets to used. viii) Working space is to be provided around the equipment for easy maintenance / repairs.
ix) Necessary cut out provision for entry and exist of fuel lines cable to be incorporated in the enclosure as per the requirement. x) A see through transparent window (glass or acrylic) In front of engine panel to provided for monitoring the operation. xi) Ducting if required, bellows, mechanical hardware like locks, hinges fasteners etc to be provided. xii) Deliverables. As per manufacturer Design 75 dBA; @ 1 mtr at 75% load under free field conditions.The temp Inside the enclosure will be within as per manufactrurers recommendations above ambient temp. xiii) The enclosure should be provided with CFL/LED light fitting for Inside illumination xiv) The battaries should be placed inside the enclosure beside the DG Set on a suitable inlsulated plat form. xv) The DG Set should be provided with external Emergency stop push button. xvi) The accoustic enclosure parts shall be of powder coated after pre treat ment process. The powder coating shade should be Genset Green. The base frame should be painted with epoxy based black shade. Make for AMF panel : DG Set OEM Make for Accoustic panel : DG Set OEM Make of DG Set : Auth OEM
The following itemes are deemed to be included in the rate Quoted for DG set:- (a) SEMI ROTARY PUMP :- Manually operated fuel pump for filling diesel in the tank of adequate capacity with inlet connection to the tank with 5 m flexible hose pipe of suitable size heavy duty for suction of diesel from barrel.
EXTERNAL ELECTRICAL SUPPLY
Supply , installing and testing of RMU 11KV 630A 21KA /3 sec outdoor SF6 insulated VCB panel 01 Nos VCB as incoming and 02 Nos LBS and 01 No VCB as out going with metering equipments all as per IS/IEC-6227/200, chamber as per internal Arc IAC-AFLR consisting of the makes in Clause 48 to Particular specifications at substn incl Plinth protection upto 1mt from ground level as per OEM standards incl provision of steps, testing and commissioning should be carried out by OEM service Engineer all as per engineer in charge:-
(b) Current Transformer 11KV indor resin cast CT:300-150/1A, CI-5P10, 2.5VA-9Nos, metering CTs:30-150/1A, CI-0.5, 2.5VA-9 nos.
(c) Potential transformer 11KV indoor resine cast type PT (11KV/rt3/110V/rt3) CI:0.5 burden:100VA.
(d) Protection Devices:self powered O/C+E/F relay with instantaneous and micro processer based, High speed tripping relay (PQ8) for 86.
(e) Metering and indicating devices:-Multi function meter, ON/OFF/Trip/trip ckt Healthy/spring charge indiction lamps, VPIS for phase indication.
(f) Panel Accessories:local/remote switch, Battery (2x12v, 24ah)& Charger, control wiring as per norms/colour code, control fues, control MCBs, space heater/tehrmostat, disconnecting terminal blocks-Ct cjt, Terminal blocks-control ckt illumination lamp, toggle switch for heater ON/OFF.
(g) Busbar connections with 630 Amps copper bus bar, Earth connections-type tested for 21 KA STC
(h) Enclosuer CRCA suitable for outdoor (IP54) installation with the provision for receiveing I/C, O/G cables through front and bottom entry , excluding termintion kits and glands. 2mm CRCA sheet thicknes for outer enclosure and 2.5 mm stain less steel for SF 6 gm tank.
(j) Load break switch:-11KV, 630A, 21 KA/3 SEC, Horizontal type draw-out with measuring CT and HT protection fuse including indication lamps R,Y,B, Ammeter, voltmeter with Mechanical interlock all as specified and directed.
Supply , installing, testing and commissioning including BI-directional flat roller-04 Nos with a gurantee period of 24 month from date of commissioning and ISI marked Transformer step down 11/0.433 KV with HT 3 phase and LT 3 phase 4 wire system copper wound with off load tap changing arrangements on HT side for a variation of secondary voltage +/-7.50% instead of 2.5% continous rating of 250 KVA out door type confroming to IS 1180 and confirming to BEE star rating 4 including the following:-
(a) Lifting lugs and hooks for transformer and tank
(b) Earthing terminal rating and diagram plate
(c) Air release device
(d) Oil filling inlet pipe with guage
(e) Drain outlet pipe with brass gate valve with dummy plug
(f) Conservator with level gauge
(g) Silica gel breaker
(h) First oil fill up upto the recommended level by the manufacturer with new oil confirming to IS 335:1993
(j) Type of connection: Delt/Star
(k) Type of cooling; ONAN
(l) Vector group: DY 11
(m) Type of connection arrangements: Cable termination boxes on both HT and LT side
(n) Temperature raise over an ambient of 50 degree centigrade max
(p) Provision of thermometer with pocket
(q) In addition to the above all standard fittings shall be provided as per IS norms
Note:- Transformer platform size 1.5 X 1.5 X 1.8m shall be measured and paid separtely.
Supply, install, testing and commissioning of 100 KVAR Automatic power factor correction panel in 7 steps consisting of following panel board made out of CRCA sheet 2 mm thick poeder coated dust and vermin proof factory made IEC 61439-1&2, IK 10 protection with angle angle iron 50x6 mm support frame and grout in PCC complete all as specified and directed of IP 65 comprising the following
250 Amps 433V 3P 36KA Manual Fixed Type Moulded Case Circuit Breaker (MCCB) with Microprocessor based release for over curent, short circuit & earth fault protection as incomer to APFC Panel
APFC RVC Relay for 8 steps
2 X 25 KVAR metallised plypropylene capacitor bank
4 X 10 KVAR and 2 X 5 KVAR metallised ply propylence capacitor bank
Capacitor duty contactor for switching on & switching off 10KVAR bank
Capacitor duty contactor for switching on & switching off 5KVAR bank
32 Amps 433V 3P 10 KVA miniture Circuit breaker for 10KVAR capacitor protection
16 Amps 433V 3P 10KA Miniature Circuit Breaker for 5KVAR capacitor protection
Supply, installation, commission, testing of LT Panel board CPRI approved indoor type, 415 Volts, 3 phase 4 wire dust and vermin proof factory made powder coated made out of 2 mm thick CRCA sheet pedestal type, with necessary hinged doors with projected an raised suitable platform size necessaray locking arrangements with angle iron ISA 50 X 50 X 6 mm along with lugs, cable glands of various sizes for cable, danger notice plate, strickering of switcher gear and the nut/bolts etc., used are to be made of rust proof meterial including as per IS: 8623 Aluminium bus bar of 300 Amps rating with heat proof colour cade, insulations suitable for three phase and four wire LT AC, 50 Hz 415 V 300 A capacity complete with powder coating, necessary internal electric connection as required and bedded in suitable size PCC 1:3:6 type C1 platform over 400 mm above ground level complete all as specified with and including the following:-
INCOMMING:
MCCB 4 pole, 160 Amp, 50 HZ, 415 V with microprocessor release Icu=36KA & Ics=100% Icu with adjustable over load setting (minimum 80% to 100%)-01 Nos
Digital multi functional meter (A, Z, V, KW, KVA) – 01 Set
LED indicator lamp for each Phase with colour code Red Yellow Blue for R Y B phase- 01 set of three
OUT GOING:-
MCCB 4 pole, 100 Amp, 50 HZ, 415 V , 16 KA with thermal magnitic release Icu=16KA & Ics=100% Icu with adjustable over load setting (minimum 80% to 100%)-02 Nos
MCCB 63 A, 415 V, 4 pole with over load, short circuit and earth fault protection with adjustable type, breaking capacity 16 KA-02 Nos.
MCCB 32 A, 415 V, 4 pole with over load, short circuit and earth fault protection with adjustable type, breaking capacity 16 KA-01 No.
MCB, SPN 6 A, 230 V with over load, short circuit and earth fault protection breaking capacity 10 KA-01 No.
Digital street lights timer single phase 240 V, 50 HZ, 24 Hrs with 16 Amps contactor complete - 01 Nos
Note:- All MCCBs/ instruments/MCBs/ Bus Bar shall be housed in a separate housing with on-off latches in the housing
All as per item No.51.00 above but 500 Amps with following:-
INCOMMING:
MCCB 4 pole, 400 Amp, 50 HZ, 415 V with microprocessor release Icu=36KA & Ics=100% Icu with adjustable over load setting (minimum 80% to 100%)-01 Nos
Digital multi functional meter (A, Z, V, KW, KVA) – 01 Set
LED indicator lamp for each Phase with colour code Red Yellow Blue for R Y B phase- 01 set of three
OUT GOING:-
MCCB 4 pole, 160 Amp, 50 HZ, 415 V , 25 KA with thermal magnitic release Icu=25 KA & Ics=100% Icu with adjustable over load setting (minimum 80% to 100%)-02 Nos
MCCB 63 A, 415 V, 4 pole 50 HZ with over load, short circuit and earth fault protection with adjustable type, breaking capacity 16 KA-02 Nos.
MCCB 32 A, 415 V, 4 pole 50 HZ with over load, short circuit and earth fault protection with adjustable type, breaking capacity 16 KA-01 No.
MCB, SPN 20 A, 230 V with over load, short circuit and earth fault protection breaking capacity 10 KA-01 No.
Digital street lights timer single phase 240 V, 50 HZ, 24 Hrs with 16 Amps contactor complete - 01 Nos
All as per item No.51.00 above but 100 Amps Aluminium bus bar with following(for water supply) . :-
INCOMMING:
MCCB 4 pole, 63 to 100 Amp, 50 HZ, 415 V with microprocessor release Icu=25KA & Ics=100% Icu with adjustable over load setting (minimum 80% to 100%)-01 Nos
OUT GOING:-
MCCB 3 pole, 32 Amp, 50 HZ, 415 V , 16 KA with thermal magnitic release Icu=16KA & Ics=100% Icu with adjustable over load setting (minimum 80% to 100%)-03 Nos
Supply and fix ON LOAD change over switch 415V in 4 pole of capacity 63 to 100 Amps - 01 Nos
MCB SPN 415 volts 10 KA rating 6-32 Amps - 04 Nos
Multifunction meter 0-100 Amps with CT - 01 Set
Indicating lamp RYB - 01 Set.
Space for FASD starter fixing - 02 No
Single Phase preventer - 02 Nos
Star delta staters ML 1 Type with appropriate relay of capcity 10 HP -02 Nos
Supply and fixing 10 sqmm single core, PVC insulated, FRLS copper condutor flexible cable drawn through and including PVC non metalic conduit and conduit accessories( bendse,elbows etc ) medium grade ISI mark of outer dia 25 mm including necessary shadles nuts , bolts and screws complete all as specified (for water supply) .
Supply and lay in trenches XLPE insulated, screened, PVC bedded, cable of size 3 Core 95 sqmm , galvanized steel strip or wire armoured , electric power cables (heavy duty) 11000 volts earthed graded with aluminium conductor all as specified.
Supplying, laying in trenches or passing through pipes, ducts or drawn across roads/paths/drains of fixed along poles/walls/floor etc, including connecting up, testing and commissioning of Cross Linked Polyethylene (XLPE) insulated, Screened, PVC bedded, Galvanized steel strip armoured electric power cable , heavy duty, with aluminium conductor 1100 Volts grade all as specified and directed of following cross section sizes and core
Cable of size 4 Core 10 sqmm
Cable of size 4 Core 16 sqmm
Cable of size 3.5 Core 25 sqmm
Cable of size 3.5 Core 35 sqmm
Cable of size 3.5 Core 70 sqmm
Cable of size 3.5 Core 120 sqmm
Cable of size 3.5 Core 185 sqmm
Cable of size 3.5 Core 300 sqmm
Supply and fixing cable jointing kit for 1.1KV for grade cable for straight through joint complete with jointing material heat shrink cable type and acessories suitable for 3.5 core/ 4 core XLPE armoured aluminium conductor of size indoor /outdoor
16 sq.mm to 35 sqmm
50 sq.mm to 95 sqmm
Supply and fixing 40 Watts 4600 lumens street light LED fitting, new generation energy saving, environmental friendly long life, versatile pressure die cast aluminium, IP66 with 10KV surge protection road way,luminaire with high power LED as light source with warranty option of 5 years and suitable driversetc connecting with 4.0 sqmm multi strandard aluminium conductor PVC insulated twin core weather proof cable from fitting to junction box and fixing to pole with and including bracket made out of GI pipe of 40mm dia light grade not less than 1.2 mtr long bent to shape, fixed to pole in any position with flat iron clamps of size 50x6 mm complete all as specified and directed. Make: Havells cat No. ENDURAPEARLNEOSL40W LED 757 PASYTOPIC or equalent Philips/Bajaj/ GE/Wipro/Surya
Supply and fixing 70 Watts 7600 lumens LED street light new generation energy saving, environmental friendly long life, versatile pressure die cast aluminium, IP66 with 10KV surge protection road way,luminaire with high power LED as light source with warranty option of 5 years and suitable driversetc connecting with 4.0 sqmm multi strandard aluminium conductor PVC insulated twin core weather proof cable from fitting to junction box and fixing to pole with and including bracket made out of GI pipe of 40mm dia light grade not less than 1.2 mtr long bent to shape, fixed to pole in any position with flat iron clamps of size 50x6 mm complete all as specified and directed.
Supply and fix rubber mat electrical insulating mats confirming to is 15652 / 2006( superceding is : 5424 – 1969 ) b.i.s + cpri + nth + erda approved size : 1 mtr x 2 mtr ( longer lengths available against order ) colour : black / red / blue ( other colour as agreed between supplier and purchaser )finish : one side plain / other side patterned tensile strength : for temp. – 10 to 55 deg. c – 15 n/mm2 (min. ) elongation at break : for temp. – 10 to 55 deg. c – 250 deg. % ( min. ) insulation resistance with water : 10,00,000 mΩ ( min. ) leakage current : 10µa ( max. )flame retardence : the mat is retarded to fire low temperature resistance : no tear, break or crack is observed in mats under force of 100n for 30 hrs. at – 40 + 3 deg. c Make : BIS/CPRI/ERDA appoved makes.
Supply and Fix cast iron class-I meterial of size 200X150X10 mm thick oval shaped for water supply pipe line/HT & LT cable route/ cable joint/ cable loop shall be cast on route indicator with engraved letters with 5 mm thick and arrow line to indicate direction of line and fixed with 900 mm long MS angle iron of size ISA 40 X 40 X 5 mm including connected earth work and excavation as in post holes in any type of soil providing PCC M-10 of size 600 X600X300 mm (using 20mm graded stone aggregate) to hold the angle iron ( by putting the split end of angle iron in to the concrete) up to ground level and painting the exposed iron surface with grey colour over a coat of primer etc complete. after tracing the route of burried water supply pipe line/cable by route tracing instrument.
Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working.
Porcelain insulator for mounting aluminium strip including fixing arrangment above ground complete all as specified and directed.
Note:- Aluminium strip 25mm X 3.15 mm along wih saddle and screws shall be measured and paid separtely.
ROAD, PATH AND CULVERT
Road stud DA-971 (Aluminium) Aluminium alloy Die casted dynamically designed very high impact strength and fitted with 2 Nos highly refectors & 2 Nos Eye balls each on both sides all as specified and directed (Make : Sinor or equivalent)
Guide post with twin reflectors made out of MS pipe of 50 mm dia and munted on oval shape metal plate or dimensions 302 X 167 mm fitted with 2 Nos 70X23 mm rectangular reflectors each sides for excellent reflectivity in night hours complete all as specified and directed. (Make : Sinor or equivalent)
SUMA ENCON PROJECTS PRIVATE LIMITED
M/s SRINIVASA CONSTRUCTION COMPANY
laasya constructions
SUNDER BUILDERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid