Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.0 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹17.0 L+₹73,708.25 (4.54%)Rejected-Finance H NO 3 1 197 P58 MYTINAGAR COLONY LB NAGAR HYDERABAD 500 074 | HYDERABAD | HYDERABAD | TELANGANA | 500074 | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹17.1 L+₹86,192.20 (5.31%)Rejected-Finance | L3 | Rejected-Finance Other than lowest bidder | |
| 4 | L4₹17.2 L+₹98,872.22 (6.09%)Rejected-Finance 21 167 KAKANI NAGAR 2ND LANE NAD POST VISAKHAPATNAM 530009 | VISAKHAPATANAM | ANDHRA PRADESH | 530009 | L4 | Rejected-Finance Other than lowest bidder |
| Sl No | Description | Qty | Unit | veerender constructions L2 | Srinivash Engineers L3 | SRI SAI RAM ENTERPRISES L1 | SVG SUPPLIES L4 |
|---|---|---|---|---|---|---|---|
| 1.00 | Material & Labour for attending day to day complaints including checking of existing street lights of any type or of any description, fixed in vertical position on poles of 9/11/12 metres or on walls including disconnecting the electric connection, removing from pole/wall if required, carrying out minor repairs like, removal of deposited carbon on joints/wires on OHT lines on top of the pole and removing of defective LED drivers/SPDs etc as required at site to make the items functional and refixing the same after repair as directed and connecting with electric feeder , testing for functioning by engaging sufficient man power, tools & plants etc to ensure safety of lights/poles as well as working persons complete all as specified and directed by the Engineer in Charge.
Note :- (a) cost of 08 complaints of 09 to 12 mtr pole for consider in 01 Job in any area under MCEME shall be included in quoted rate.
(b) T&P such as hydra/telescopic ladder required for attending the complaints is included in the quoted rate.
(c) Cost of replacement of unserviceable parts such as LED drivers/SPDs etc shall be paid under respective item of Sch as supply only .
(d) Cost of repalcement of unservicable parts such as corrision connection cables, taking down and fixing shall be included in the item rate.
(e) Before attending complaint/work shut down should be taken from GE (Utility) rep. If required. | 300 | Each Job | 243 ₹72,900 Lowest | 600 ₹1,80,000 | 250 ₹75,000 | 1,000 ₹3,00,000 |
| 2.00 | Supply only of LED Driver of similar wattage with operating voltage input ac 85- 300 volt , pf> .95 as per IS 15885 with inbuilt surge protection of minimum 5 kv and BIS certified suitable for 45 watts LED street light fittings of any make complete all as specified and directed. | 15 | Each | 207 ₹3,105 Lowest | 400 ₹6,000 | 350 ₹5,250 | 760 ₹11,400 |
| 3.00 | Supply only of LED Driver of similar wattage with operating voltage input ac 85- 300 volt , pf> .95 as per IS 15885 with inbuilt surge protection of minimum 5 kv and BIS certified suitable for 70/72 watts LED street light fittings of any make complete all as specified and directed. | 20 | Each | 270 ₹5,400 Lowest | 800 ₹16,000 | 500 ₹10,000 | 1,000 ₹20,000 |
| 4.00 | Supply only of LED Driver of similar wattage with operating voltage input ac 85- 300 volt , pf> .95 as per IS 15885 with inbuilt surge protection of minimum 5 kv and BIS certified suitable for 90 watts LED street light fittings of any make complete all as specified and directed. | 35 | Each | 306 ₹10,710 Lowest | 980 ₹34,300 | 600 ₹21,000 | 1,600 ₹56,000 |
| 5.00 | Supply only of LED Driver of similar wattage with operating voltage input ac 85- 300 volt , pf> .95 as per IS 15885 with inbuilt surge protection of minimum 5 kv and BIS certified suitable for 100/110/120 watts LEDstreet light fittings of any make complete all as specified and directed. | 18 | Each | 450 ₹8,100 Lowest | 1,200 ₹21,600 | 700 ₹12,600 | 1,900 ₹34,200 |
| 6.00 | Supply only of LED Driver of similar wattage with operating voltage input ac 85- 300 volt , pf> .95 as per IS 15885 with inbuilt surge protection of minimum 5 kv and BIS certified suitable for 100 watts LED flood light fittings of any make complete all as specified and directed. | 15 | Each | 801 ₹12,015 | 1,000 ₹15,000 | 800 ₹12,000 Lowest | 1,700 ₹25,500 |
| 7.00 | Supply only of LED Driver of similar wattage with operating voltage input ac 85- 300 volt , pf> .95 as per IS 15885 with inbuilt surge protection of minimum 5 kv and BIS certified suitable for 120 watts LED flood light fittings of any make complete all as specified and directed. | 10 | Each | 891 ₹8,910 Lowest | 1,200 ₹12,000 | 1,000 ₹10,000 | 1,900 ₹19,000 |
| 8.00 | Supply only of LED Driver of similar wattage with operating voltage input ac 85- 300 volt , pf> .95 as per IS 15885 with inbuilt surge protection of minimum 5 kv and BIS certified suitable for 150 watts LED flood light fittings of any make complete all as specified and directed. | 5 | Each | 900 ₹4,500 Lowest | 1,500 ₹7,500 | 1,100 ₹5,500 | 2,200 ₹11,000 |
| 9.00 | Supply only of LED Driver of similar wattage with operating voltage input ac 85- 300 volt , pf> .95 as per IS 15885 with inbuilt surge protection of minimum 5 kv and BIS certified suitable for 200 watts LED flood light fittings of any make complete all as specified and directed. | 5 | Each | 1,008 ₹5,040 Lowest | 1,800 ₹9,000 | 1,100 ₹5,500 | 2,400 ₹12,000 |
| 10.00 | Supply only of surge protection device of 10 KV suitable upto 200W LED light fittings suitable to operate on input voltage 440 AC, 50 Hz, complete all as specified and directed. | 45 | Each | 252 ₹11,340 | 100 ₹4,500 Lowest | 250 ₹11,250 | 1,000 ₹45,000 |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
13 Nov 2025, 6:00 pmClosed
GE MCEME SECUNDERABAD
GARRISON ENGINEER MCEME, MCEME CAMPUS, TRIMULGHERRY (POST) SECUNDERABAD - 500015
REPAIRS MAINT OF STREET LIGHTS HIGH MAST LIGHTS AND CONNECTED ITEMS UNDER GE MCEME SECUNDERABAD
2025_MES_736599_1
8707/E8
Open Tender
Civil Works
Item Rate
180 days
SECUNDERABAD
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE MCEME SECUNDERABAD
₹50,000
Yes
21 Jan 2026
24 Oct 2025
15 Nov 2025
24 Oct 2025
13 Nov 2025
7 Nov 2025
Amount
Material & Labour for attending day to day complaints including checking of existing street lights of any type or of any description, fixed in vertical position on poles of 9/11/12 metres or on walls including disconnecting the electric connection, removing from pole/wall if required, carrying out minor repairs like, removal of deposited carbon on joints/wires on OHT lines on top of the pole and removing of defective LED drivers/SPDs etc as required at site to make the items functional and refixing the same after repair as directed and connecting with electric feeder , testing for functioning by engaging sufficient man power, tools & plants etc to ensure safety of lights/poles as well as working persons complete all as specified and directed by the Engineer in Charge. Note :- (a) cost of 08 complaints of 09 to 12 mtr pole for consider in 01 Job in any area under MCEME shall be included in quoted rate. (b) T&P such as hydra/telescopic ladder required for attending the complaints is included in the quoted rate. (c) Cost of replacement of unserviceable parts such as LED drivers/SPDs etc shall be paid under respective item of Sch as supply only . (d) Cost of repalcement of unservicable parts such as corrision connection cables, taking down and fixing shall be included in the item rate. (e) Before attending complaint/work shut down should be taken from GE (Utility) rep. If required.
Supply only of LED Driver of similar wattage with operating voltage input ac 85- 300 volt , pf> .95 as per IS 15885 with inbuilt surge protection of minimum 5 kv and BIS certified suitable for 45 watts LED street light fittings of any make complete all as specified and directed.
Supply only of LED Driver of similar wattage with operating voltage input ac 85- 300 volt , pf> .95 as per IS 15885 with inbuilt surge protection of minimum 5 kv and BIS certified suitable for 70/72 watts LED street light fittings of any make complete all as specified and directed.
Supply only of LED Driver of similar wattage with operating voltage input ac 85- 300 volt , pf> .95 as per IS 15885 with inbuilt surge protection of minimum 5 kv and BIS certified suitable for 90 watts LED street light fittings of any make complete all as specified and directed.
Supply only of LED Driver of similar wattage with operating voltage input ac 85- 300 volt , pf> .95 as per IS 15885 with inbuilt surge protection of minimum 5 kv and BIS certified suitable for 100/110/120 watts LEDstreet light fittings of any make complete all as specified and directed.
Supply only of LED Driver of similar wattage with operating voltage input ac 85- 300 volt , pf> .95 as per IS 15885 with inbuilt surge protection of minimum 5 kv and BIS certified suitable for 100 watts LED flood light fittings of any make complete all as specified and directed.
Supply only of LED Driver of similar wattage with operating voltage input ac 85- 300 volt , pf> .95 as per IS 15885 with inbuilt surge protection of minimum 5 kv and BIS certified suitable for 120 watts LED flood light fittings of any make complete all as specified and directed.
Supply only of LED Driver of similar wattage with operating voltage input ac 85- 300 volt , pf> .95 as per IS 15885 with inbuilt surge protection of minimum 5 kv and BIS certified suitable for 150 watts LED flood light fittings of any make complete all as specified and directed.
Supply only of LED Driver of similar wattage with operating voltage input ac 85- 300 volt , pf> .95 as per IS 15885 with inbuilt surge protection of minimum 5 kv and BIS certified suitable for 200 watts LED flood light fittings of any make complete all as specified and directed.
Supply only of surge protection device of 10 KV suitable upto 200W LED light fittings suitable to operate on input voltage 440 AC, 50 Hz, complete all as specified and directed.
S&F in replacement of LED street light fitting 45 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete Make : Havells/Bajaj/Crompton/Philips
All as above item No.11 but 70 Watts
All as above item No.11 but 90 Watts
All as above item No 11 but 100 Watts
S&F in replacement of LED flood light 100 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete. Make : Havells/Bajaj/Crompton/Philips
All as above item No 15but 120 Watts
All as above item No 15 but 150 Watts
All as above item No.15 but 200 Watts
M&L for replacement of unserviceable street light bracket made out of GI pipe 1.2 mtr long 32 to 50mm dia suitable for street light fitting, light grade bent to shape as directed including nut, bolts, washer and MS flat iron clamp of required size for fixing bracket suitable for PCC/ steel tubular poles all as directed incl taking down of old unsv bracket.
Supply and laying of cable XLPE insulated, armoured heavy duty electric cable, galvanised steel strip or wire armoured, with aluminium conductor electric power cable(heavy duty) 1100 volts grade with stranded aluminium conductor of size (a) 35 sqmm x 3.5 core Note :- (a) The cost of Al thimbles/lugs and cable gland etc is included in quoted rate and no extra payment will be made for it. (b) Excavation, earth work, sand cushioning and brick protection will be measured and paid separately under respective items.
All as above item No.20 but 16 sqmm x 4.0 core.
Taking down damaged Unsv conductor any type and removal complete all as specified and directed.
Taking down Unsv UG cable any size/ type complete all as specified and directed.
S&F in replacement of PVC insulated multi core round stranded copper conductor (Flexible) 3 core of size 1.5 sqmm 1100 volts grade heavy duty including all accessories complete
S&F in replacement of automatic street light switch using Nature Switch for automatic switching of street lights based on LUX level of natural light the sensor (nature switch) along with suitable power contactors and MCBs (Input-output) should be enclosed in pole/wall mountable enclosure made of rust proof, Electric shock proof, termite proof and FR grade SMC junction box (sintex make) conforming to IP 54.the contactor,MCBs and copper circuit wiring (min.10sqmm) should enough to take: three-phase load of 12-15KW;contactor Rating 32Amps; MCB(spn) Rating 32Amps. Healer Enterprises Model no SWADEEP-02EC12KW3P or equivalent in Seimens and Havells.
S&F in replacement of automatic street light switch using Nature Switch for automatic switching of street lights based on LUX level of natural light the sensor (nature switch) along with suitable power contactors and MCBs (Input-output) should be enclosed in pole/wall mountable enclosure made of rust proof, Electric shock proof, termite proof and FR grade SMC junction box (sintex make) conforming to IP 54.the contactor,MCBs and copper circuit wiring (min.6sqmm) should enough to take: three-phase load of 8-11KW;contactor Rating 20Amps; MCB(spn) Rating 20Amps. Healer Enterprises Model no SWADEEP-02EC8KW3P or equivalent in Seimens and Havells.
Supply & Erecting Steel Tubular Swaged Pole Type 410-SP-31 (9.0 METRE long) including Cast Iron Base Plate, Finial Taper Plug, Cap, Mild Steel Bolts, Nuts, Screws including applying Two Coats of Black Bituminous Paint Internally and Externally upto Planting Depth and applying with Two Coats of Aluminium Painting over a Coat of Aluminium Primer (Externally from Top of Coping) including dismantling old unserviceable complete all as specified and as directed.
Excavation in trenches not exceeding 1.5M wide and not exceeding 1.5M in depth and getting out in hard/dense soil for laying of under ground cable all as directed.
Excavation in trenches not exceeding 1.5M wide and exceeding 1.5M in depth and getting out in hard/dense soil for laying of under ground cable all as directed.
Returning filling in including spreading, leveling watering and well ramming in layer not exceeding 25 Cms and all as directed
Removal of excavated surplus soil not exceeding 50 m and depositing where directed at al level not exceeding 1.5 m above the starting point.
Supply and spreading sand in trenches as cushioning to under ground cable on top and bottom of cable all as specified.
Supplying and laying dry bricks in trenches over under ground electric cable for mechanical protection with width equal to length of bricks with well burnt sub class ‘B’ old size bricks laid flat complete.
M& L for cement concrete in foundation, filling concrete for poles of type D-2 1:4:8 using 40 mm graded aggregate all as specified and directed.
M& L for cement concrete type B-1 1:2:4 using 20 mm graded aggregate for foundation of poles etc.
M& L for cement concrete type C-1 1:3:6 using 20 mm graded aggregate for coping/road finishing / foundation etc.
Cutting of existing road/PCC for laying of LT cables / pipes complete all as specified and directed
S&F in replacement of GI pipe light grade 40mm bore for cable protection complete all as specified and directed.
M&Lfor rubbing/cleaning with emery paper or by other meance and preparation of old painted surface of steel poles 8.5/9 metres long excluding planting depth complete and painting the pole up to full height including channels street light brackets with one coat of aluminium paint and making black & white including strips with synthetic enamelled paint with alternate strips 30 cm height with black and white strips upto 1.5metres height writing pole numbers as per existing practice, making round base of dia 120mm by using yellow colour and marking the pole numbers of letter size equal to 70mm in height by using black colour with stencil complete all as specified and directed by Engr-in-Charge. Note :- The T&P required for the paintaing job under this item such as hydra/telescopic ladder etc arranged by the contractor and included in the quoted rate of this item.
M&L for rubbing/cleaning with emery paper and preparation of old painted surface of steel poles 8.5/9 metres long writing pole numbers as per existing practice, making round base of dia 120mm by using yellow colour and marking the pole numbers of letter size equal to 70mm in height by using black colour with stencil of pole any type complete all as specified and directed by Engr-in-Charge.
S & F in replacement of Pole mounted junction box of size 200 x 140 x 95 mm outdoor type and 6 amp MCB SP complete incl fixing arrangements with suitable size clamps, nut & bolts for fixing on pole all as specified and directed. Make Syntex Catpart No GS-JB-2014 and equivalent make of Hansel
S&F in replacement of MCB SP 6 to 32 Amp 10 KA C Curve
S&F in replacement of MCB TPN 32 Amp 10 KA C Curve
S&F in replacement of MCB TPN 40 to 63 Amp 10 KA C Curve
veerender constructions (BID ID -3482536)
Srinivash Engineers (BID ID -3471484)
SVG SUPPLIES (BID ID -3469434)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Document
0.66 MB
Tender Documents
Tender Documents • 1.04 MB
BOQ
BOQ • 2.12 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .