EE Kolkata IT Division PWD
Writers Building Kolkata
Replacement of CCTV System components damaged due flooding of Server Rooms in the Old Campus of Dr. R Ahmed Dental College and Hospital at 114, A.J.C Bose Road, Kolkata - 700 014
2025_WBPWD_955154_1
WBPWD/EEKIT/E-NIT-220/T/25-26
Open Tender
IT WORKS ORG
Item Rate
30 days
R Ahmed Dental College and Hospita
As specified in NIT
3 documents required · 3 mandatory
₹5,145
Writers Building Kolkata
30 Jan 2026
22 Nov 2025
19 Dec 2025
22 Nov 2025
17 Dec 2025
24 Nov 2025
24 Nov 2025
Amount
SITC of 1 x 03 KVA Rack Mount Online UPS (1-ph input, 1-ph output) System with 1 x 3024 VAH (Min) Back-up Battery, Rack, Links, Cables & Other Accessories. Technology: Rack mount, Digital Signal Processing (DSP) controlled Microprocessor based technology true On-line, Parallel Load Sharing Mode (1+N) configuration enabled only; Input: 1-phase, 220/230/240V, 176 ~ 280 Vac (full load) ; 80 ~ 175 Vac (50% ~ 100% load), >0.99PF (full load), 50Hz ± 5Hz, Current Harmonic Distortion <3.0%; Output: 1-phase, 240V ± 1%, > 0.99PF (full load), 50 Hz ± 0.1Hz; Harmonic Distortion (input current): < 3% (linear load); Crest factor: 3:1; Efficiency (AC/DC) Overall is (Online Mode) >=95% at full load; Operating Temperature: 0 ~ 55°C; Relative Humidity: 5 ~ 95% (non-condensing); Battery: SMF, 12 V, Mono Block batteries. The UPS battery shall be of Advanced Glass Mat Valve Regulated Sealed Lead Acid Battery Construction type (AGM or VRSLAB) in ABS Flame Retardant (UL94V-O) grade (UL 2436) spill containment casing to meet UL 62368-1/IEC 62133 or equivalent standards type to obtain a full rated load battery backup, standard FR DC Cable; Battery set: Complete with self standing cubicle or cabinet; Certification: CE, BIS; Display: LCD display and LED indicators; 1 x 03 KVA 1Ø/1Ø (Phase input/output) with 1 x 3024 VAH (Min) Battery Backup or equivalent VAH or Higher, DC BUSBAR VOLTAGE ±192/±288; 12V SMF Battery, with MS-Rack, Interlink Nyvin Cable, Connector, Special battery terminal insulation cover and other accessories. Make: Schneider, APC, DELTA, Vertiv, Numeric; Make Battery: Amararaja-Quanta/Exide, Model: Rack Mount Only. Warranty: 03(Three) years on UPS & 03(Three) years on Battery onsite comprehensive OEM warranty with parts and service except force majeure.
SITC of 1 x 06 KVA Rack Mount Online UPS (1-ph input, 1-ph output) System with 1 x 6240 VAH (Min) Back-up Battery, Rack, Links, Cables & Other Accessories. Technology: Rack mount, Digital Signal Processing (DSP) controlled Microprocessor based technology true On-line, Parallel Load Sharing Mode (1+N) configuration enabled only; Input: 1-phase, 220/230/240V, 176 ~ 280 Vac (full load) ; 80 ~ 175 Vac (50% ~ 100% load), >0.99PF (full load), 50Hz ± 5Hz, Current Harmonic Distortion <3.0%; Output: 1-phase, 240V ± 1%, > 0.99PF (full load), 50 Hz ± 0.1Hz; Harmonic Distortion (input current): < 3% (linear load); Crest factor: 3:1; Efficiency (AC/DC) Overall is (Online Mode) >=95% at full load; Operating Temperature: 0 ~ 55°C; Relative Humidity: 5 ~ 95% (non-condensing); Battery: SMF, 12 V, Mono Block batteries. The UPS battery shall be of Advanced Glass Mat Valve Regulated Sealed Lead Acid Battery Construction type (AGM or VRSLAB) in ABS Flame Retardant (UL94V-O) grade (UL 2436) spill containment casing to meet UL 62368-1/IEC 62133 or equivalent standards type to obtain a full rated load battery backup, standard FR DC Cable; Battery set: Complete with self standing cubicle or cabinet; Certification: CE, BIS; Display: LCD display and LED indicators; 1 x 06 KVA 1Ø/1Ø (Phase input/output) with 1 x 6240 VAH (Min) Battery Backup or equivalent VAH or Higher, DC BUSBAR VOLTAGE ±192/±288; 12V SMF Battery Make: Schneider, APC, DELTA, Vertiv, Numeric; Make Battery: Amararaja-Quanta/Exide, Model: Rack Mount Only. Warranty: 03(Three) years on UPS & 03(Three) years on Battery onsite comprehensive OEM warranty with parts and service except force majeure.
ADD GST @18%
ADD LWC @1%
Earthline Infocomm Pvt. Ltd (BID ID -7645667)
JOY MAA TARA ELECTRICAL CO (BID ID -7627010)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.92 MB
BOQ_2290331.xls
BOQ • 0.31 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .