EE Kolkata IT Division PWD
Writers Building Kolkata
Replacement of CCTV System components damaged due flooding of Server Rooms in the Old Campus of Dr. R Ahmed Dental College and Hospital at 114, A.J.C Bose Road, Kolkata - 700 014
2025_WBPWD_955154_1
WBPWD/EEKIT/E-NIT-220/T/25-26
Open Tender
IT WORKS ORG
30 days
R Ahmed Dental College and Hospita
As specified in NIT
3 documents required · 3 mandatory
₹5,145
Writers Building Kolkata
30 Jan 2026
22 Nov 2025
19 Dec 2025
22 Nov 2025
17 Dec 2025
24 Nov 2025
24 Nov 2025
Amount
SITC of 1 x 03 KVA Rack Mount Online UPS (1-ph input, 1-ph output) System with 1 x 3024 VAH (Min) Back-up Battery, Rack, Links, Cables & Other Accessories. Technology: Rack mount, Digital Signal Processing (DSP) controlled Microprocessor based technology true On-line, Parallel Load Sharing Mode (1+N) configuration enabled only; Input: 1-phase, 220/230/240V, 176 ~ 280 Vac (full load) ; 80 ~ 175 Vac (50% ~ 100% load), >0.99PF (full load), 50Hz ± 5Hz, Current Harmonic Distortion <3.0%; Output: 1-phase, 240V ± 1%, > 0.99PF (full load), 50 Hz ± 0.1Hz; Harmonic Distortion (input current): < 3% (linear load); Crest factor: 3:1; Efficiency (AC/DC) Overall is (Online Mode) >=95% at full load; Operating Temperature: 0 ~ 55°C; Relative Humidity: 5 ~ 95% (non-condensing); Battery: SMF, 12 V, Mono Block batteries. The UPS battery shall be of Advanced Glass Mat Valve Regulated Sealed Lead Acid Battery Construction type (AGM or VRSLAB) in ABS Flame Retardant (UL94V-O) grade (UL 2436) spill containment casing to meet UL 62368-1/IEC 62133 or equivalent standards type to obtain a full rated load battery backup, standard FR DC Cable; Battery set: Complete with self standing cubicle or cabinet; Certification: CE, BIS; Display: LCD display and LED indicators; 1 x 03 KVA 1Ø/1Ø (Phase input/output) with 1 x 3024 VAH (Min) Battery Backup or equivalent VAH or Higher, DC BUSBAR VOLTAGE ±192/±288; 12V SMF Battery, with MS-Rack, Interlink Nyvin Cable, Connector, Special battery terminal insulation cover and other accessories. Make: Schneider, APC, DELTA, Vertiv, Numeric; Make Battery: Amararaja-Quanta/Exide, Model: Rack Mount Only. Warranty: 03(Three) years on UPS & 03(Three) years on Battery onsite comprehensive OEM warranty with parts and service except force majeure.
SITC of 1 x 06 KVA Rack Mount Online UPS (1-ph input, 1-ph output) System with 1 x 6240 VAH (Min) Back-up Battery, Rack, Links, Cables & Other Accessories. Technology: Rack mount, Digital Signal Processing (DSP) controlled Microprocessor based technology true On-line, Parallel Load Sharing Mode (1+N) configuration enabled only; Input: 1-phase, 220/230/240V, 176 ~ 280 Vac (full load) ; 80 ~ 175 Vac (50% ~ 100% load), >0.99PF (full load), 50Hz ± 5Hz, Current Harmonic Distortion <3.0%; Output: 1-phase, 240V ± 1%, > 0.99PF (full load), 50 Hz ± 0.1Hz; Harmonic Distortion (input current): < 3% (linear load); Crest factor: 3:1; Efficiency (AC/DC) Overall is (Online Mode) >=95% at full load; Operating Temperature: 0 ~ 55°C; Relative Humidity: 5 ~ 95% (non-condensing); Battery: SMF, 12 V, Mono Block batteries. The UPS battery shall be of Advanced Glass Mat Valve Regulated Sealed Lead Acid Battery Construction type (AGM or VRSLAB) in ABS Flame Retardant (UL94V-O) grade (UL 2436) spill containment casing to meet UL 62368-1/IEC 62133 or equivalent standards type to obtain a full rated load battery backup, standard FR DC Cable; Battery set: Complete with self standing cubicle or cabinet; Certification: CE, BIS; Display: LCD display and LED indicators; 1 x 06 KVA 1Ø/1Ø (Phase input/output) with 1 x 6240 VAH (Min) Battery Backup or equivalent VAH or Higher, DC BUSBAR VOLTAGE ±192/±288; 12V SMF Battery Make: Schneider, APC, DELTA, Vertiv, Numeric; Make Battery: Amararaja-Quanta/Exide, Model: Rack Mount Only. Warranty: 03(Three) years on UPS & 03(Three) years on Battery onsite comprehensive OEM warranty with parts and service except force majeure.
ADD GST @18%
ADD LWC @1%
Earthline Infocomm Pvt. Ltd (BID ID -7645667)
JOY MAA TARA ELECTRICAL CO (BID ID -7627010)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.92 MB
BOQ_2290331.xls
BOQ • 0.31 MB
Download all tender documents and submit your bid