| 1 | L1₹14.0 LAccepted-AOC | L1 | Accepted-AOC Being a lowest bidder and reasonable rate quoted | |
| 2 | L2₹15.6 L+₹74,548 (5.01%)Rejected-Finance BHAVANI KRUPA GANDHI CHOWK PULGAON 442302 | WARDHA | MAHARASHTRA | 442302 | L2 | Rejected-Finance Other than lowest tender | |
| 3 | L3₹16.7 L+₹1.8 L (12.2%)Rejected-Finance | L3 | Rejected-Finance Other than lowest tender | |
| 4 | L4₹16.7 L+₹1.8 L (12.4%)Rejected-Finance | L4 | Rejected-Finance Other than lowest tender | |
| 5 | Rejected-Technical PULGAON | - | Rejected-Technical Not enlisted in category a(ii) |
Tender Value
₹20 L
EMD Value
₹30,000
Closing Date
18 May 2021, 6:00 pmClosed
GE PULGAON
GE PULGAON CAD CAMP PULGAON PIN-442303
REPAIRS REPLACEMENT OF OLD VINTAGE CI GI PIPE LINE INCLUDING ALL FITTINGS FIXTURES AIR RELEASED VALVE SLUICE VALVE AND OTHER CONNECTED ITEMS IN RA AREA UNDER GE PULGAON
2021_MES_436521_1
8886/PUL/E8
Open Tender
Pipes and Pipe related activities
Item Rate
180 days
GE PULGAON
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE PULGAON
₹30,000
Yes
21 Jun 2021
16 Apr 2021
24 May 2021
16 Apr 2021
18 May 2021
30 Apr 2021
16 Apr 2021 - 28 Apr 2021
Amount
Excavation in trenches, not exc. 1.5 metre wide and not exc. 1.5 metre in depth for foundation, in soft loose soil Complete all as specified and as directed.
Excavation in trenches, not exc. 1.5 metre wide and not exc. 1.5 metre in depth for foundation, hard/dense soil Complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in any type of soil Complete all as specified and as directed.
Removing excavated material n.exc 50 mtr and depositing where directed at a level not exc. 1.5 mtr above the starting point Complete all as specified and as directed.
Supply and fix in repairs CI Foot valve unit,double flapper type suitable for 200mm bore including required nuts and bolts etc and cone set and fixing the same to the suction pipe of the pump set availble in to the sump appx at a height of 10 feet below the ground level of the sump all as specified and directed.
Supply & fix champion/turner style graphite gland packing of sizes as 8/10/12/16mm thick. For motor/sluice valve complete all as specified and directed.
S&F in repair/replacement of 300mm dia CI non return valve heavy duty both end flanged incl making flanged joint, rubber gasket, nuts & bolts washers with by pass arrangments of 20mm GI pipe with gate valve 20mm complete all as specified and directed.
All as per item No 07…………………... But for 80 mm dia valve
Taking up or down steel tubing and connections, including cleaning for refixing or removal to store or staking at site of 15 mm dia Complete all as specified and as directed.
All as per item No 09…………………... But for 20 mm dia
All as per item No 09…………………... But for 25 mm dia
All as per item No 09…………………... But for 40 mm dia
All as per item No 09…………………... But for 50 mm dia
All as per item No 09…………………... But for 80 mm dia
Refixing/laying of 15 mm dia old steel tubing and connections in new or old positons (wall/ ceiling, floor, in trenches etc) threading, rethreading and with fittings Complete all as specified and as directed.
All as per item No 15…………………... But for 20 mm dia
All as per item No 15…………………... But for 25 mm dia
All as per item No 15…………………... But for 40 mm dia
All as per item No 15…………………... But for 50 mm dia
All as per item No 15…………………... But for 80 mm dia
Supply and fixing/laying of 15 mm dia in trenches steel tube medium grade with all fitting and fixed complete to wall, ceilings or laid in floor/ trench Complete all as specified and as directed.
All as per item No 21…………………... But for 20 mm dia
All as per item No 21…………………... But for 25 mm dia
All as per item No 21…………………... But for 40 mm dia
All as per item No 21…………………... But for 50 mm dia
All as per item No 21…………………... But for 80 mm dia
Supply and fixing in replacement of 15 mm bore gunmetal gate valve with iron wheel screwed both ends for iron pipe and fixed Complete all as specified and as directed.
All as per item No. 27….. But for 20 mm bore
All as per item No. 27….. But for 25 mm bore
All as per item No. 27….. But for 40 mm bore
All as per item No. 27….. But for 50 mm bore
M&L for CI special/fittings suitable for CI flanged/socket ends pipe upto 80 to 150 mm bore dia such as bends, (any radius and angle), tapers any type (straight, bend, increasing, decreasing or double socket etc) tee piece, single branch 'Y' junction, double branch, cross (all flanged), collars, caps & plug, tail pieces, reducers, mechanical joint, etc. complete all as specified and as directed,
M&L for CI special/fittings suitable for CI flanged/socket ends pipe upto 200 to 300 mm bore dia such as bends, (any radius and angle), tapers any type (straight, bend, increasing, decreasing or double socket etc) tee piece, single branch 'Y' junction, double branch, cross (all flanged), collars, caps & plug, tail pieces, reducers etc. complete all as specified and as directed.
Taking up 80 mm bore old U/S steel hume pipe line/CI/GI any type water mains pipes, any class,(including all fittings),disconnecting pipes and fittings complete all as specified and as directed.
All as per item No. 34….. But for 100 mm bore
All as per item No. 34….. But for 150 mm bore
All as per item No. 34….. But for 200 mm bore
All as per item No. 34….. But for 300 mm bore
Relaying only old pipe in good condition/pipe taken out from trenches for repairs in any length including fittings etc. of 80 mm bore complete all as specified and as directed.
All as per item No. 39….. But for 100 mm bore
All as per item No. 39….. But for 150 mm bore
All as per item No. 34….. But for 200 mm bore
All as per item No. 34….. But for 300 mm bore
Supply and fix cast iron pipes with spigot and socket ends centrifugally casted class LA in any length suitable for rubber tytan joint and Laid in trenches of 80 mm bore complete all as specified and as directed.
All as per item No. 38….. But for 100 mm bore
All as per item No. 38….. But for 150 mm bore
All as per item No. 39….. But for 200 mm bore
All as per item No. 39….. But for 300 mm bore
M&L for Run lead joint for spigot socket cast iron pipes and fitting, including caulking properly and making joint leak proof of 80 mm bore complete all as specified and as directed.
All as per item No. 49….. But for 100 mm bore
All as per item No. 49….. But for 150 mm bore
All as per item No. 49….. But for 200 mm bore
All as per item No. 49….. But for 300 mm bore
M&L for burning out lead joint in position , including removing lead to store / stacked at site to issue under credit for 80 mm bore complete all as specified and as directed.
All as per item No. 54….. But for 100 mm bore
All as per item No. 54….. But for 150 mm bore
All as per item No. 54….. But for 200 mm bore
All as per item No. 54….. But for 300 mm bore
Supply and fix of sluice valve PN-1.6 heavy duty ISI marked as per (IS-14846) with flanged ends with 02 Nos of rubber gaskets, nut bolts and washers along with SS spindle and operating wheel for 80 mm bore complete all as specified and as directed.
All as per item No. 59….. But for 100 mm bore
All as per item No. 59….. But for 150 mm bore
All as per item No. 59….. But for 200 mm bore
All as per item No. 59….. But for 300 mm bore
M&L for rubber tyton joints for suitable for sockets and spigot CI pipes including rubber gasket for 80 mm bore complete all as specified and as directed.
All as per item No. 64….. But for 100 mm bore
All as per item No. 64….. But for 150 mm bore
All as per item No. 64….. But for 200 mm bore
All as per item No. 64….. But for 300 mm bore
Taking out sluice valves refacing, regrinding and refixing including repacking stuffing box of sluice valve spindle brass including taking apart and reassembling of 300 mm Complete all as specified and as directed.
Taking out sluice valves refacing, regrinding and refixing including repacking stuffing box of sluice valve spindle brass including taking apart and reassembling of 200 mm Complete all as specified and as directed.
Taking out sluice valves refacing, regrinding and refixing including repacking stuffing box of sluice valve spindle including taking apart and reassembling of 150 mm Complete all as specified and as directed.
M&L in repair of rusted & crack CI water branch connection 80mm dia by using mechanical joint with connecting all accessories Complete all as specified and as directed. Note : (i) cost of gasket and nut bolts ,washers'jointing of materials as required are inclusive in above job. ii) Required T&P for job is provided by the Contractor is deemed to be included in the item rate. (iii) Excavation for pipe is included in job Work.
M&L in repair of rusted & crack CI water branch connection 100mm dia by using mechanical joint with connecting all accessories Complete all as specified and as directed. Note : (i) cost of gasket and nut bolts ,washers'jointing of materials as required are inclusive in above job. ii) Required T&P for job is provided by the Contractor is deemed to be included in the item rate. (iii) Excavation for pipe is included in job Work.
M&L in repair of rusted & crack CI water branch connection 150mm dia by using mechanical joint with connecting all accessories Complete all as specified and as directed. Note : (i) cost of gasket and nut bolts ,washers'jointing of materials as required are inclusive in above job. ii) Required T&P for job is provided by the Contractor is deemed to be included in the item rate. (iii) Excavation for pipe is included in job Work.
M&L in repair of rusted & crack CI water branch connection 200mm dia by using mechanical joint with connecting all accessories Complete all as specified and as directed. Note : (i) cost of gasket and nut bolts ,washers'jointing of materials as required are inclusive in above job. ii) Required T&P for job is provided by the Contractor is deemed to be included in the item rate. (iii) Excavation for pipe is included in job Work.
M&L in repair of rusted & crack CI water branch connection 300mm dia by using mechanical joint with connecting all accessories Complete all as specified and as directed. Note : (i) cost of gasket and nut bolts ,washers'jointing of materials as required are inclusive in above job. ii) Required T&P for job is provided by the Contractor is deemed to be included in the item rate. (iii) Excavation for pipe is included in job Work.
M&L for dismantling old valve chamber and construction of brick masonarry new valve pit chamber of size 1200mmx1200mmx1200mm (internal ) size 100mm thick PCC (1:4:8) type D2 lean concrete foundation (using 40mm graded stone aggregate) providing well burnt brick masonary wall of 23mm thick built in CM (1:6) rendering in cement 1:6 finished even smooth using extra cement internally and 20 mm thick in CM 1:4 and finished fair and even supply and fix 3.15 mm thick MS sheet steel cover fixed on (50x50x6) mm thick angle iron frame embbeded in PCC coping with locking arrangement and 1 No 50mm size 4 levers lock with key in duplicate Standard size and MS hold fast and handle made out of (25 x 6)mm flat iron appplying two coats of synthetic enamel paint of approved shade over a coat of primer (Red Oxide) to all exposed surface making good all disturbed surface to match surrounding complete all as specified and directed.
Dismantling and taking out existing sluice valve from CI pipe line by removing bolts, nuts rubber gasket, joints for 80 mm bore complete all as specified and as directed.
All as per item No. 78….. But for 100 mm bore
All as per item No. 78….. But for 150 mm bore
All as per item No. 78….. But for 200 mm bore
All as per item No. 78….. But for 300 mm bore
Supply and fix in replacement rotational moulded polyethylene triple layer water storage tanks in replacement (vertical cylindrical with closed top) double layered ISI marked with existing inlet, outlets & provision of washouts, (vent pipe all as directed of capacity 500 litres including all new tank nipples of suitable size.
Supply and fix in replacement rotational moulded polyethylene triple layer water storage tanks in replacement (vertical cylindrical with closed top) double layered ISI marked with existing inlet, outlets & provision of washouts, (vent pipe all as directed of capacity 1000 litres including all new tank nipples of suitable size.
Supply and fix in replacement of 15mm bore ball valves high pressure made out of PTMT Make- Prayag/Symet complete with epoxy coated Aluminium rod, high density ball etc of size :-
All as per item No. 85….. But for 20 mm bore
All as per item No. 85….. But for 25 mm bore
M & L for Cleaning and removing all dirt and scale etc from tank and from the mouths of circulating pipes for the tanks of capacity 500 litre
All as per item No. 88….. But for 1000 litre
All as per item No. 88….. But for 2000 litre
Testing of Treated water(Drinking water) sample as per IS-10500 including collecting of sample from the pump house and handed over it to the authorised lab for testing purpose all as directed by Engr-In-Charge.
Testing of Raw water sample as per IS-10500 including collecting of sample from the pump house and handed over it to the authorised lab for testing purpose all as directed by Engr-In-Charge.
M/s Dara Constructions, Pulgaon
SHRI RANI SATI TRADERS
SHREE SIDDHIVINAYAK TRADERS
Bidder Name
SHRI RANI SATI TRADERS
SHREE SIDDHIVINAYAK TRADERS
M/s Dara Constructions, Pulgaon
M/s MM TRADERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .