CWE(BHI)/BHI-36/2023-24 REPAIR / REPLACEMENT/ MAINTENANCE OF DG SETS INSTALLATION ALONGWITH ALLIED WORKS AT AF STATION BHISIANA
2023_MES_619791_1
CWE(BHI)/BHI-36/2023-24
Open Tender
Civil Works
Item Rate
180 days
AFS Bhisiana
As per cover 1
8 documents required · 8 mandatory
₹500
Yes
GE (AF) Bhisiana
₹40,000
Yes
27 Oct 2023
20 Sept 2023
19 Oct 2023
20 Sept 2023
17 Oct 2023
5 Oct 2023
Amount
Material and labour for servicing of DG set 7.5 KVA to 40 KVA by draining out engine oil, removing oil filter, replace with new one and refill the engine oil, Clean Fuel Feed Pump, replace primary and secondary fuel filter along with 'O'-Ring, replace paper type air filter and safety cartrige, Replace air cleaner oil bathe type, Check Alignment of exhaust system, Check belt tension and tighten or loosen belt tension as per requirement, Blow compressed air with the help of blower on radiator fins to clean it, Check all the clips and tighten if required, Clean Battery terminals with cotton clothe, Apply acid proof grease or petroleum jelly on battery terminals, Check electrolyte level of battery and top up distilled water if electrolyte level is low, Check electrical connection of starter and tighten if required check belt tension on charging alternator and adjust if required. Check output voltage of charging alternator. Tighten all the foundation nuts and bolts if required, check LLOP and HWT with multimeter, Check stopper and adjust tightness of link wire if required check tightness of wiring connection and adjust accordingly, Remove RWL clean it check with multimeter and refit it, Clean body of generator from inside and outside properly, complete all as specified and directed by Engr-in-Charge. Note for Item No: 1.00 1) Quoted rate include cost of oil filters, fuel filters and air filters. 2) Quoted rate inclue labour and transport charges. 3) Cleaning Clothes required is deemed to be included in quoted rates. 4) Engine oil, distilled water, LLOP and HWT shall be measured seperately.
All as per item No 1 but of DG set 50 KVA to 100 KVA, complete all as specified and directed by Engr-in-Charge.
All as per item No 1 but of DG set 125 KVA to 250 KVA, complete all as specified and directed by Engr-in-Charge.
All as per item No 1 but of DG set 300 KVA to 437.5 KVA, complete all as specified and directed by Engr-in-Charge.
Material and labour for calibration of wiring of engine safety control systems from control panel to engine control gadgets like high water temperature & low oil pressure and shut down valve, battery charger 12V, self starters etc. for 7.5 KVA to 40 KVA DG Set and repair all the safety features, complete all as directed and specified by Engr-in-Charge.
All asper item No 5 but DG set 50 KVA to 100 KVA, complete all as specified and directed by Engr-in-Charge.
All asper item No 5 but DG set 125 KVA to 250 KVA, complete all as specified and directed by Engr-in-Charge.
All asper item No 5 but DG set 300 KVA to 437.5 KVA, complete all as specified and directed by Engr-in-Charge.
M & L for repair and calibration of DG Set governor mechanism as per calibration procedure and norms for 7.5 KVA to 40 KVA DG Set installation and testing of the same after completion, complete all as specified and as directed by Engr-in-Charge.
All as per item No 9 but DG set 50 KVA to 100 KVA, complete all as specified and directed by Engr-in-Charge.
All as per item No 9 but DG set 125 KVA to 250 KVA, complete all as specified and directed by Engr-in-Charge.
All as per item No 9 but DG set 300 KVA to 437.5 KVA, complete all as specified and directed by Engr-in-Charge.
M&L for repair and calibration of FIP, fuel injectors including replacement of barel plunger and cup 'O' rings alongwith Plunger spring,Roller bearing, element,Delivery valve,Fuel injector nozzle element for 7.5 KVA to 40 KVA DG Set and testing of the same after completion, complete all as specified and as directed by Engr-in-Charge.
Material and labour for in replacement of auto voltage regulator complete with wire connection and connecting to existing field coil 12/24 Volt DC for cap of 7.5 KVA to 40 KVA, complete all as specified and directed by Engr-in-Charge.
All as per item No 14 but DG set 50 to 100 KVA, complete all as specified and directed by Engr-in-Charge.
All as per item No 14 but DG set 125 to 250 KVA, complete all as specified and directed by Engr-in-Charge.
All as per item No 14 but DG set 300 to 437.5 KVA, complete all as specified and directed by Engr-in-Charge.
Material and labour for taking out radiator assembly from existing DG set ( 7.5 KVA to 40 KVA ) and repair to radiator tank, cleaning complete with anti corrosion chemical C-cleaner/radiwash cleaner and fixing/making radiator leakage proof complete all as specified & directed by Engineer-in-Charge.
All as per item No 18 but DG set 50 KVA to 100 KVA, complete all as specified and directed by Engr-in-Charge.
All as per item No 18 but DG set 125 KVA to 250 KVA, complete all as specified and directed by Engr-in-Charge.
All as per item No 18 but DG set 300 KVA to 437.5 KVA, complete all as specified and directed by Engr-in-Charge.
Dismantling and taking out carefully defective water pump assembly 7.5 KVA to 40 KVA DG Set and opening into parts cleaning servicing and drying up the spares and sort out the damaged/defective parts and re-fixing the same after replacement of water pump repair kit and water seal unit including pump belt, complete all as specified and directed by Engr-in-Charge.
All as per item No 22 but DG set 300 KVA to 437.5 KVA, complete all as specified and directed by Engr-in-Charge.
Supply and fixing of coupling complete(engine-alternator) in all respect with rubber flange as per existing shape/size, With nut & boltsof Make:Kirloskar/Cummins/Ashok Leylnd and suitable for 50 KVA to 100 KVA DG Sets, complete all as specified and directed by Engr-in-Charge.
All as per item No 24 but DG set 125 KVA to 250 KVA, complete all as specified and directed by Engr-in-Charge.
All as per item No 24 but DG set 300 KVA to 437.5 KVA, complete all as specified and directed by Engr-in-Charge.
Material and labour for repairs/ replacement of turbo charger including replacement of charger kit with all unserviceable parts and testing after completion for 300 KVA to 437.5 KVA KVA capacity DG Sets, complete all as specified and directed by Engr-in-Charge.
Supply and fixing of in replacement of Self starter 24 volts DC for Kirloskar, Cummins & Ashoka Layland engine, complete all as specified and directed by Engr-in-charge.
All as per item No 28 but 12 V DC, complete all as specified and directed by Engr-in-Charge.
Material and labour for repair of worn out parts of self starter 24 volts DC including plunger, bush, armature, gear and pinion, field coil, coil of magnetic switch, complete all as specified and directed by Engr-in-Charge. Note: 1) If replacement of any part of self starter is required than contractor has to replace that part without any extra cost.
All as per item No 30 but self starter 12V DC, complete all as specified and directed by Engr-in-Charge.
Supply and fixing Battery lead copper wire with thimble and terminal heavy duty made out of brass & 100 cm length of lead, complete all as specified and directed by Engr-in-Charge.
All as per item No 32 but 60 cm length, complete all as specified and directed by Engr-in-Charge.
Material and labour for Solenoid stopper coil 24 volts DC operated with lead and fixing clamps, complete all as specified and directed by Engr-in-Charge.
Material and labour for Solenoid stopper coil 12 volts DC operated with lead and fixing clamps, complete all as specified and directed by Engr-in-Charge.
Supply and filling coolant for radiator of DG set of any cap DG Set, make Bosch/Golden crusher /TVS all as specified and directed by Engr-in-Charge.
Supply and filling distilled water for batteries of DG set of any make / capacity, complete all as specified and as directed by Engr-in-Charge.
Material and labour for replacement broken MS Hinges suitable for Canopy door for any type/capacity of DG Sets (as per sample) all as specified and directed by Engr-in-Charge.
Supply and fix in replacement low oil pressure switch 12/24V, 3.5 to 10 kg/Sq. cm, complete all as specified and directed by Engr-in-Charge.
Supply and fix in replacement HWT switch 12/24V, complete all as specified and directed by Engr-in-Charge.
Supply & filling the engine oil 20W40 by draining out old U/S engine oil, clean the the oil sump, complete all as specified and directed by Engr-in-Charge.
Supply and fixing power contactor coil 240/415 V AC amp rating 115 to 150 A including taking down/out unserviceable One, complete all as specified and as directed by Engr-in-Charge.
Supply and fixing MCB 63 Amp, TP with rupturing capacity 10 kA including taking down/out unserviceable One, complete all as specified and as directed by Engr-in-charge.
Supply and fixing MCCB 160 Amp, TP with rupturing capacity 36 kA including taking down/out unserviceable One, complete all as specified and as directed by Engr-in-charge.
Supply and fixing MCCB 200 Amp, TP with rupturing capacity 36 kA including taking down/out unserviceable One, complete all as specified and as directed by Engr-in-charge.
Supply and fixing MCCB 250 Amp, TP with rupturing capacity 36 kA including taking down/out unserviceable One, complete all as specified and as directed by Engr-in-charge.
Material and labour for calibration of AMF control wiring including opening disconnecting LT Cable connections with care from Auto-Main Failure Panel and checking throughly with Fault Detector Instrument at Site suitable for 7.5 KVA to 40 KVA DG Set including replacement of Internal Wiring with Copper Conductor Cable lugs, thimble etc.if required, complete all as specified and as directed by Engr-in-charge
Material and labour for replacement of sealed maintenance free, generator starting system battery 150 AH12 Volt suitable for DG set of dimension 557x172x240mm and weight 46.65 Kgs including initial factory charging, complete all as specified and as directed by Engr-in-charge
Material and labour for replacement of sealed maintenance free, generator starting system battery 180 AH12 Volt suitable for DG set of dimension 557x172x240mm and weight 46.65 Kgs including initial factory charging, complete all as specified and as directed by Engr-in-charge
Material and labour for calibration of AMF control wiring including opening disconnecting LT Cable connections with care from Auto-Main Failure Panel and checking throughly with Fault Detector Instrument at Site suitable for 50 KVA to 100 KVA DG Set including replacement of Internal Wiring with Copper Conductor Cable lugs, thimble etc. if required, complete all as specified and as directed Engr-in-charge
Material and labour for calibration of AMF control wiring including opening disconnecting LT Cable connections with care from Auto-Main Failure Panel and checking throughly with Fault Detector Instrument at Site suitable for 300 KVA to 437.5 KVA DG Set including replacement of Internal Wiring with Copper Conductor Cable, lugs, thimble etc. if required, complete all as specified and as directed Engr-in-charge
Supply and fixing in replacement power Contactor 630 Amp 3 Pole with 2NO + 2NC Contacts and Coil Voltage 220/415 Volt including taking down unserviceable one, complete all as speciifed and as directed by Engr-in-charge
All as per item No 54 but 500 amp 3 pole, complete all as specified and directed by Engr-in-Charge.
All as per item No 54 but 255 amp 3 pole, complete all as specified and directed by Engr-in-Charge.
All as per item No 54 but 200 amp 3pole, complete all as specified and directed by Engr-in-Charge.
All as per item No 54 but 185 amp 3 pole, complete all as specified and directed by Engr-in-Charge.
All as per item No 54 but 115 amp3 pole, complete all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement phase failure Relay suitable for AMF Panel any type including taking down unserviceable One, complete all as speciifed and as directed by Engr-in-charge.
Supply and fixing in replacement ON-Delay timer suitable for AMF Panel any type including taking down unserviceable One, complete all as speciifed and as directed by Engr-in-charge.
Supply and fixing in replacement Automatic battery charger 24 volt 15 amp with auto cut off at 27.5 volt including delivering uninterupted 220 volt AC including taking down/ out old unserviceable, complete all as specified and as directed by Engr-in-charge.
All as per item No 62 but 12 volt 15 amp, complete all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement V-belt for suitable for DG set by taking out/down unserviceable belt, complete all as specified and as directed by Engr-in-Charge.
Material and labour for cleaning fuel tank of DG Set 7.5 KVA to 40 KVA both internally and externally by removing all dust, greasy content, sediments by washing with liquid acid, repair for leakage by taking down/out and brazing/welding and refixing the frame in position, complete all as specified and directed.
All as per item No 65 but of DG set 50 to 100 KVA, complete all as specified and directed by Engr-in-Charge.
All as per item No 65 but of DG set 125 to 250 KVA, complete all as specified and directed by Engr-in-Charge.
All as per item No 65 but of DG set 300 to 437.5 KVA, complete all as specified and directed by Engr-in-Charge.
REYANSH GARG AND COMPANY
M/s Luxmi Constructions
Rasvinderpalandco
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .