Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.3 CrAccepted-Finance | ₹7.3 Cr | L1 | Accepted-Finance The firm offered a discount of 3.13 percent on the quoted amount of Rs. 75867600.00 |
| 2 | L2₹7.4 Cr+₹4.7 L (0.64%)Accepted-Finance | ₹7.4 Cr+₹4.7 L (0.64%) | L2 | Accepted-Finance The firm offered a discount of 2.51 percent on the quoted amount of Rs. 75867600.00 |
| 3 | L3₹7.6 Cr+₹24.5 L (3.33%)Accepted-Finance | ₹7.6 Cr+₹24.5 L (3.33%) | L3 | Accepted-Finance L3 |
| 4 | L4₹7.9 Cr+₹55.8 L (7.60%)Accepted-Finance | ₹7.9 Cr+₹55.8 L (7.60%) | L4 | Accepted-Finance L4 |
| 5 | L5₹7.9 Cr+₹58.7 L (7.99%)Accepted-Finance | ₹7.9 Cr+₹58.7 L (7.99%) | L5 | Accepted-Finance L5 |
Tender Value
₹8.9 Cr
EMD Value
₹17.9 L
Closing Date
1 Jun 2020, 4:00 pmClosed
ER. GIRDHARI LAL
Office of the Deputy General Manager, JKPCC Ltd., Unit 5th Kathua.
Construction of New Degree College at Ghagwal, Kathua Phase-1st (summer zone)
2020_PWDJK_96530_1
e-NIT NO. 01/Kathua of 2020-21 Dt. 08-05-2020
Open Tender
Civil Works
Item Rate
540 days
KATHUA
Please refer Tender documents.
7 documents required · 7 mandatory
₹5,000
Yes
Financial Controller, JKPCC Ltd.
₹17.9 L
Yes
O/o The Managing Director, JKPCC Jammu
1 Mar 2021
8 May 2020
2 Jun 2020
8 May 2020
1 Jun 2020
11 May 2020
20 May 2020
Amount
Part A
Earth work in excavation by manual means in trenches for foundations, drains, pipes, cables etc. (Non exceeding 1.5 mtr. in width) and for shafts , wells, cess pits and the like not exceeding 10 Sqm on Plan , depth up to 1.5 mtr. including disposal of excavated earth, with all leads and lift complete, disposed earth to be levelled & neatly dressed: a. All kinds of soil
Providing & laying in position cement concrete of specified grade excluding the cost of centering and shuttering -- All work up to plinth level 1:4:8 (1 cement : 4 coarse sand : 8 graded stone agg. 40 mm nominal size) Nallah.
Providing & Laying in position specified grade of reinforced cement concrete excluding the cost of centring, shuttering, finishing & reinforcement. All work up to plinth level. 1:1 ½ :3 (1 cement : 1 ½ coarse sand : 3 graded stone agg. 20 mm nominal size) .
Providing & laying in position cement concrete of specified grade excluding the cost of centering and shuttering -- All work up to plinth level 1:3:6 (1 cement : 3 coarse sand : 6 graded stone agg. 20 mm nominal size) crushed.
Providing and laying damp- proof course 40 mm thick with cement concrete 1:2:4 (1 cement :2 coarse sand: 4 graded stone aggregate 12.5 mm nominal size) crushed.
Brick work with common burnt clay F.P.S (non- modular) bricks of class designation 75 in foundation and plinths in cement mortar 1:6 (1cement : 6 coarse sand).
Extra for brick works in super structure above plinth level up to floor five level.
Half Brick masonry with bricks of class designation 75 in foundation and plinth in cement mortar 1 : 4 (1 cement : 4 coarse sand)
Extra for half brick masonry in superstructure above plinth level up to floor V level.
Providing and fixing wood work in frames of doors, windows, clerestory windows & others frames, wrought framed & fixed in position with holdfast lugs or with dash fasteners of required dia& length (hold fast lugs or with dash fasteners shall be paid for separately) salwood.
Providing & fixing flush doors with 1.0mm thick sunmica on both sides including lipping 35 x 6mm including ISI marked M.S pressed Butt hinges bright finished off required size with necessary screws which will be paid for separately, all complete as per direction of engineer- in charge. Second class Deodar wood. 35 mm thick
a) Providing 4mm thick panels of plain glass for glazing shutters(only panel area to be measured)including cost of Teak Wood beadings of required size complete.
b) Providing & fixing 5 mm thick panels of plane glass for fixed glazing panels/ shutters (only panel area to be measured) including cost of Teak Wood beadings of required size complete.
Providing &fixing glazed shutters for doors , windows and clerestory windows using 10 Kg / Sqm. (4 mm thick) float glass panes , incl. ISI marked M.S pressed butt hinges bright finished off required size with necessary screws 35 mm thick of second class Deodar wood.
Proving & fixing 35 mm thick wire gauze shutters using galvanised M.S wire gauze of average width for aperture 1.4 mm both direction with wire of dia. 0.63mm for doors, windows & clerestory windows with hinges & necessary screws. Second class deodar wood.
Providing & Laying Reinforced cement concrete work in beams suspended floors, roofs, having slopes up to 15 * landings , balconies , shelves , Chajjas, lintels, bands plain window sills, stair cases & spiral stair cases up to floor five level excluding the cost of centering , shuttering, finishing & reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone agg. 20 mm nominal size).
Reinforcement for RCC works incl. straightening, cutting, bending, placing in position & binding all complete cold twisted bars.
Centering& shuttering incl. strutting , propping etc. and removal of form work for :- a. Foundations, footings, bases of columns etc.
b. Suspended floors , roofs, landings, balconies, & access platform.
c. Lintels, beams, plinth beams, girders, bressumers and cantilevers.
d. Edges of slabs and breaks in floor and walls under 20 cm wide.
e. Columns, Pillars, Piers, Abutments, Posts and struts
12 mm cement plaster to ceiling of 1:4 (1 cement : 4 fine sand)
15 mm cement plaster of mix 1:6 (1 cement : 6 fine sand).
20 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement : 4 coarse sand)
Filling available excavated earth (excl. rock) in trenches , plinth , sides of foundations etc in layers not exceeding 20 cm in depth consolidating each deposited layer by ramming & watering, lead up to 50 m & lift up to 1.5 m. (A) Quantity available
(B) Quantity unavailable
Providing & laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS :15622 of approved make in all colours and shades , laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand) including grouting the joints with white cement and matching pigments etc. complete ; Size of tile 60x60 cm
Providing & fixing ceramic glazed floor tiles 300x300 mm (thickness to be specified by the manufacturers) of 1st quality conforming of IS: 13755 of NITCO, ORIENT, SOMANY , KAJARIA or equivalent make in colour such a cement mortar 1:4 (1 cement : 4 coarse sand) incl. pointing the joints with white cement & matching pigment etc. complete.
Providing and fixing 1st quality ceramic glazed tiles conforming to IS: 13753 of minimum thickness 5 mm of approved make like NITCO, ORIENT, SOMANY, KAJARIA, or equivalent make in all colour , shades except burgundy, bottle green, black of any size as approved by Engineer In Charge in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 Kg per Sqm. Incl. pointing in white cement mixed with pigment of matching shade complete.
Providing & fixing M.S grills of required pattern in frames of windows etc. with M.S flats, square or round bars etc. all complete. Fixed to openings / wooden frames with raw / plugs, screws etc.
Providing and fixing at allheights false ceiling of 12.5mm thick tapered edge gypsum board confirming of IS:2025 including providing and fixing of frame work made of special section power pressed from M.S.sheet and galvanized in accordance with zinc coating 600 as per IS: 277 and consisting of angle cleats of size 25mm wide X 1.6mm thick with flanges of 22mm and 37mm at 12mm center to center one flange fixed to the ceiling with dash fastener 12.5mm dia X 40mm long with 6mm dia bolts to the angle hangers of 25 X 25 X 5 mm of required length and other end of angle hanger being fixed with nut and bolts to G.I channels 45 X 15 X 0.9 mm running at the rate of 1200mm centre to centre which the ceiling section 0.5mm thick button wedge of 80mm with tapered flanges of 26mm each having clips of 10.5mm at 450mm centre to centre shall be fixed in a direction perpendicular to G.I channel with connecting clips made out of 2.64mm dia X 230mm long G.I wire at every junction including fixing of gypsum board with ceiling section and perimeter channels 0.5mm thick 27mm high having flanges of 20mm and 30 mm long .
Providing & laying water proofing treatment in sunken portion of WCs ,bathroom etc. , by applying cement slurry mixed with water proofing cement compound consisting of applying:- (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0. 253kg /sqm . This layer will be allowed to air cure for 4 hours . (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm .this layer will be allowed to air cure for 4 hours followed with water curing for 48 hours .
Providing gola 75X75 mm in cement concrete 1:2:4 (1cement : 2 coarse sand : 4 stone aggregate 10 mm down gauge) including finishing with cement mortar 1:3 ( 1 cement : 3 fine sand) as per standard design. In 75 x 75 mm deep chases.
Making Khurras 45 X 45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded stone agg. of 20 mm nominal size) over P.V.C sheet 1 m X 1 m X 400 micron finished with 12 mm cement plaster 1: 3 mix. (1 cement : 3 coarse sand) and a coat of neat cement rounding the edges and making and finishing the outlet complete.
Making plinth protection 50 mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone agg. 20 mm nominal size) over 75 mm bed of dry brick ballast 40 mm nominal size well rammed and consolidated & grouted with fine sand including finishing the top smooth. (Crushed).
Providing and applying white cement based putty of average thickness 2 mm, of approved brand and manufacture, over the plastered wall surface to prepare the surface even and smooth complete.
Providing and applying cement primer of approved brand and manufacture two or more coats on newly putty surface
Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade. Two or more coats in new work.
Applying priming coat with ready mixed pink or grey primer of approved brand and manufacture on wood work (hard & soft wood).
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade Two or more coats on new work.
Providing and fixing 4x5mm flat iron hold fasts 40cm long incl. Fixing to frame with 10mm dia. bolts,nuts and wooden plugs and embedding in cement conc. Blocks30x10x15 cms in 1:3:6
Finishing walls with textured exterior paint of required shade on new work ( two or more coats applied @ 3.28 litres / 10 sqm over and including base coat water proofing cement paint applied @ 2.2 kg / 10 sqm complete including all necessary scaffolding extra including cost of all material , leads , lifts and carriages up to site of work complete ) complete as per specifications and directions of engineer incharge.
Cement concrete flooring 1:2:4 finished with the floating coat of neat cement including cement slurry but excluding the cost of nosing of steps extra complete (50mm thick with 20mm nominal size crushed stone agg.
Providing and fixing glass strips in joints of cement concrete flooring ( 40mm wide X 4mm thick ) .
Granite work :-Providing and fixing (gang saw cut mirror polish pre moulded and pre polished ) machine cut for flooring steps and risers .
Providing and fixing of kota stone slab flooring of 20mm thick base laid over and jointed with grey cement mixed with pigment to match the shade of slab including rubbing and polishing complete with base of 1:4 (1 cement 4 coarse sand) in ground floor including all carriage upto site of job.
Providing and fixing 50mm dia stainless steel railing of 304 grade of hollow tube 1.6mm thick of Jindal / salem make or equivalent including welding and fixing with stainless steel machine screws for making required size and shape , buffing extra complete .
Polishing on wood and wood based surfaces with touch wood polished two coats including preparing the surface smooth ( including cost of all material , leads , lifts and carriages extra upto to site of work complete .
Extra for providing and fixing of stainless steel nevel post ( ornamental ) including top ball of 304 grade of required height duley anchored to floor with dash fasteners complete as per the directions of engineer incharge.
Providing and laying cement conc.in 1:5:10. Mix for flooring using brick agg. 40mm nominal size excl. cost centreing and shuttering all work up to floor V level.
Carriage of different materials by Mechanical Transport including loading unloading and stacking at site. (A) Sand from average distance of 20 km by M.T. (Av.)
(B) Stone agg.20mm and 40mm from an average distance of 20 km by M.T. (Av.)
(C) Bricks from an average distance of 15km by M.T. (Av.)
Plumbing
Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing citern and CP flush with fittings, C.I. / M.S. brackets 40mm bend diameter flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete including painting of fittings and brackets, cutting and making good the walls and floors wherever required. a) W.C pan with ISI marked white solid plastic seat and lid. With white vitreous china flushing cistern & C.P flush bend
Providing and fixing wash basin with C.I / M.S brackets, 15mm C.P brass pillar taps, 32mm C.P brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required. a) White vitreous china wash basin size 550 x 400mm with a pair of 15mm C.P brass pillar taps
Providing and fixing controller flush, low level cistern made of vitreous china with all fittings complete. a) 10 litre (full flush) capacity white
Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430 x 260 x 350mm and 340 x 410 x 265mm sizes respectively with automatic flushing cistern with C.I / M.S brackets standard size of G.I flush pipe and C.P brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required. a) One urinal basin with 5 litre P.V.C white automatic flushing citernof approved quality
Providing and fixing C.P brass angle valve for basin mixer and gyser points of approved make conforming to IS : 8931 a) 15mm nominal bore
Providing anf fixing C.P brass bib cock of approved quality conforming to IS : 8931 a) 15mm nominal bore
Providing and fixing P.V.C waste pipe for sink or wash basin including P.V.C waste fittings complete a) 40mm dia
Providing and fixing of C.P Grating of required size (100mm)
Providing and fixing of C.P Jet for European type WC
Providing and fixing 600 x 450mm bevelled edge mirror of superior glass (of approved quality) complete with 6mm thick hard board ground fixed to wooden cleats with C.P brass screws and washers complete
Providing and fixing PTMT liquid soap container 109mm wide, 125mm high and 112mm distance from wall of standard shape with brackets of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms.
Providing and fixing PTMT towel ring tapezoidal shape 215mm long, 200mm wide with a minimum distance of 37mm from wall face with concealed fittings arrangements of approved quality and colour, weighing not less than 88 gms.
Providing and fixing on wall face unpplasticised - Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10mm gap of thermal expansion a) 110mm diameter
Providing and fixing on wall face unplasticised - PVC moulded fittings / accessories for unplasticised - Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10mm gap for thermal expansion. a) 110 x 110 x 110mm single tee with door
b) 110mm bend
c) 75mm Floor Trap
d) 110mm "P" Trap
Providing and fixing unplasticised - PVC pipe clips / M.S U Clumps of approved design to unplasticised - PVC rain water pipes by means of 50 x 50 x 50 mm hard wood plugs, screwed with M.S screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete a) 110mm
Providing and fixing G.I pipes complete with G.I fittings and clamps, including cutting and making good the walls etc. a) 15mm dia nominal bore
b) 25mm dia nominal bore
Providing and fixing kitchen sink with C.I brackets, C.P brass chain with rubber plug, 40mm C.P brass waste complete, including painting the fittings and brackets, cutting and making good the walls wherever required. a) White glazed fire clay kitchen sink of size 600 x 450 x 250mm
Providing and fixing C.P brass close hole basin mixer piller tap of approved quality and make, weighing not less than 1.970 Kg a) 15mm nominal bore of standard back type
Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 makred indicating the BIS License No. with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank (Sintex, Electroplast, star, lotus or equivalent having valid ISI license).
Providing and fixing ball valve (brass) of approved quality complete a) 25mm nominal bore
Constructing brick masonry chamber for underground C.I Inspection chamber and bend with 75 class designation bricks in cement mortar 1:5 (1cement : 5 fine sand) C.I cover with frame (light duty) 455 x 610mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and eight of frame 15kg) R.C.C top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 40mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size), inside plastering 12mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design inside dimensions 455 x 610mm and 45 cms deep for single piping With F.P.S bricks with Crushed stone aggregate
Internal Electrification Work
SUB HEAD-1 WIRING Wiring for switch controlled primary light points with 1.5 sq mm FRLS PVC insulated stranded copper conductor 1100 volt grade wires in PVC surface/concealed conduit including cost of providing saddles etc for surface conduiting and/or cost of cutting and filling chases for recessed conduiting and including the cost of providing and fixing a 6 Amp 240 volt grid plate mounted modular switch with modular cover plate in zinc chromate passivated MS box and including the cost of running 1.5 sqmm PVC insulated stranded copper conductor wire for loop earthing complete as per specifications( Group C)
Wiring for switch controlled emergency light points with 1.5 sq mm FRLS PVC insulated stranded copper conductor 1100 volt grade wires in PVC surface / concealed conduit including cost of providing saddles etc for surface conduiting and/or cost of cutting and filling chases for recessed conduiting and including the cost of providing and fixing a 6 Amp 240 volt grid plate mounted modular switch with modular cover plate in zinc chromate passivated MS box and including the cost of running 1.5 sqmm PVC insulated stranded copper conductor wire for loop earthing complete as per specifications and as required
Wiring for ceiling fan points with 1.5 sq mm FRLS PVC insulated stranded copper conductor 1100 volt grade wires in PVC surface / concealed conduit including cost of providing saddles etc for surface conduiting and/or cost of cutting and filling chases for recessed conduiting and including the cost of providing and fixing a 6 Amp 240 volt grid plate mounted modular switch with modular cover plate in zinc chromate passivated MS box with space for mounting an electronic fan regulator and including the cost of running 1.5 sqmm PVC insulated stranded copper conductor wire for loop earthing complete as per specifications.
Wiring for exhaust fan points with 1.5 sq mm FRLS PVC insulated stranded copper conductor 1100 volt grade wires in PVC surface / concealed conduit including cost of providing saddles etc for surface conduiting and/or cost of cutting and filling chases for recessed conduiting and including the cost of providing and fixing a 3 pin 6 Amp shuttered socket outlet and 6 amp 240 volt grid plate mounted modular switch with modular cover plate in zinc chromate passivated MS box and including the cost of running 1.5 sqmm PVC insulated stranded copper conductor wire for loop earthing complete as per specifications. Conduit carrying non-essential wiring shall not have essential or UPS wiring. Wiring for essential and UPS Providing,transportation will have thier own conduit system. No mixing of wiring is allowed.
Providing,transportation & fixing following suitable size modular GI box on surface or in recessas, painting etc.required. 2 Module
4 Module
6 Module
Providing and fixing of following size modular cover plate on existing modular metal boxes etc. as required. 1 or 2 Module
4 Module
6 Module
Providing,transportation and fixing of 6 Amp 3/5 pin modular socket-on the existing modular plate & switch box excluding modular plate as required.
Providing,transportation and fixing of 16 Amp modular switch on the existing modular plate & switch box excluding modular plate as required.
Providing,transportation and fixing of 16 Amp modular socket on the existing modular plate & switch box excluding modular plate as required.
Providing and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
Providing and fixing stepped type 2M-electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Providing,transportation and fixing ISI marked medium class PVC conduit on surface/recessed along with accessories including the cost of providing saddles etc for surface conduiting and/or cost of cutting and filling chases for recessed conduiting complete as per specifications as below and as required for sub circuits/ voice/ data/ TV system. 25 mm dia
40 mm dia
Providing,transportation and fixing of RJ-11 modular socket on the existing modular plate & switch box excluding modular plate as required for telephone system
Providing and drawing 2Pair 0.5 sq mm FR PVC insulated annealed copper conductor, unarmored telephone cable in the existing recessed PVC conduit as required.
Providing,transportation and fixing of the following sheet steel clad wall / recess mounting 10 Pair telephone tag block of IDC type constructed from 16 SWG sheet steel, finished with red oxide coating & two coats of paint, with hinged gasketted door and complete with adequately rated and sized telephone terminal block to receive incoming and outgoing wires.
Providing,transportation and fixing of RJ-45 modular socket on the existing modular plate & switch box excluding modular plate as required for networking system
Providing,transportation fixing, laying, testing and commissioning of 4-pair Cat 6e LAN cable in existing concealed / surface conduits in partition wall, complete as required. Telephone system and computer network will have separate conduit. No mixing of telephone and power wiring is allowed.
SUB HEAD III-SUB MAINS AND CABLES Wiring for circuits/submains with FRLS PVC insulated stranded copper conductor 1100 volt grade wires in surface/concealed conduit and including FR PVC insulated copper wire for earthing and making suitable end connections complete as required and as below. 2 X 2.5 sq.mm + 1 X 2.5 sq.mm earth wire.
2 X 4 sq. mm + 1 X 4 sq. mm earth wire.
2 X 6 sq. mm + 1 X 6 sq. mm earth wire.
2 X 10 sq. mm + 1 X 10 sq. mm earth wire.
2 X 16 sq. mm + 1 X 16 sq. mm earth wire.
SUB HEAD IV-DISTRIBUTION SYSTEM Providing,transportation, Providing and fixing following way,horizontal type three pole/single pole and neutral,sheet steel, MCB distribution board, 415/240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/ RCCB/ Isolator). 6 way TPN double door
8 way TPN double door
12 way SPN double door
16 way SPN double door
Non-essential, Emergency and Power will have separate sub main boards. No mixing of wiring is allowed.
Providing and fixing 5 amps to 32 amps rating, 240 volts SP MCB 10kA, "C" curve, miniature circuit breaker suitable in the existing MCB DB complete with connections, testing and commissioning etc.
Providing and fixing following rating, double/four pole, 240/415 volts, DP/TPN MCB 10kA "C" curve in the existing MCB DB complete with connections, testing and commissioning etc. as required. 32 amp
100 amps TPN
Providing and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 25 amps
Providing and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
Providing,transportation , providing and commissioning of following size cable in pipe/ Tray/ clamped to wall with suitable clamps saddles and fixing bolts. 3.5 core 240 Sq mm AL XLPE
3.5 core 120 Sq mm AL XLPE
Laying in ground including the cost digging and back filling with sand and brick protection as required The costs shall include for all cables to be provided with a 1D gap and shall be properly clamped with cable clamps and ties. Identification tags shall be provided for all cables and route markers for cables in ground. 3.5 core 240 Sq mm AL XLPE
3.5 core 120 Sq mm AL XLPE
Providing,transportation and making end termination of the following size XLPE insulated cables 1100 Volt grade including cost of crimping tinned copper heavy duty lugs, brass compression glands, insulation tape and all requisite material for completion of joints. 3.5 core 240 Sq mm AL XLPE
3.5 core 150 Sq mm AL XLPE
Providing,transportation and fixing of 6in dia heavy PVC pipe complete as required.
Providing,transportation ,providing and fixing of 4in dia heavy PVC pipe complete as required .
Providing,transportation and fixing of 50W LED slim flood light.
Providing,transportation,providing and fixing of fan box
Providing,transportation,providing and fixing of fan plates big size
SUB HEAD V-FIXTURES AND FITTING Supply, transportation and fixing of 1x1 18W surface downlighter with a nominal system lumen output of 2050 lumens and a minimum system efficacy of min100 lm/W complete as required The luminaire shall have a rated system lifetime of 50,000 burning hours at L70 with LG7 The luminaire shall meet IP20 rating with THD<10%. The luminaire housing should made of aluminium and the luminaire optics shall have a high efficiency diffuser with more than 85% transmittance.
Supply, transportation and fixing of 2x2 36W surface downlighter with a nominal system lumen output of 2050 lumens and a minimum system efficacy of 115 lm/W complete as required The luminaire shall have a rated system lifetime of 50,000 burning hours at L70 with LG7 The luminaire shall meet IP20 rating with THD<10%. The luminaire housing should made of aluminium and the luminaire optics shall have a high efficiency diffuser with more than 85% transmittance.
SITC of ISI marked 5star energy saving 1200 mm sweep ceiling fan including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable etc. as required.
SITC of exhaust fan 450 mm sweep in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.
Sample of all type of light fixtures / fans / exhaust fans / other fittings shall be approved from architect / site engineer & the sample of each approved fixture / fitting shall be kept & maintained at site.
SUB HEAD VI-Cable Tray Providing,transportation fixing and installing 150 mm width X 50 mm depth X 1.6 mm thickness size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, inconvenient sections, including bolts & nuts, painting suspenders etc as required.
SUB HEAD VI-EARTHING Providing,transportation & Installation of earth pit comprising of 75 mm Cu pipe filled with crystalline conductive mixture with copper strip of size 40mm x 6mm of length 2 mtrs with eco friendly backfill compound 50 Kgs etc as required conforming to BIS standards having brick masonary chamber with hinged cover. (General Earthing for Each Panel)
(25 x4) mm GI Strip through PVC sleeve (Electrical Earthing) (From Electrical Earthing Pit to Electrical Earthing Busbar)
Providing and fixing of lightning arrestor finial, made of 25 mm dia 300 mm long, copper tube, having single prong at top, with 85mm dia 3 mm thick copper base plate including holes etc. complete job as required.
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required. (For Horizontal & Vertical run)
Providing,transportation ing and fixing 20 amps, 240 volts, SPN industrial type, socket outlet.
Design, manufacture, supplying fixing in position, testing and commissioning of the following front operated cubicle type, front access, dead back, steel enclosed free standing, dust and vermin proof, switchboard with with hinged and lockable doors complete with interconnections
630 Amps TPN MCCB
250 Amps TPN MCCB
100 Amp DP MCB
125 Amp TPN MCB
63 Amp FP Change over Switch
Cast resin current transformers
Amp & Volt Meter
White phase indicating lamps
Supply and fixing of iron stands for panels
Supply & Installation of earth pit as required
Supply and fixing of GI strip
supply and fixing of spreaders for solid connections of cables with 630Amp MCCB's
supply and fixing of spreaders for solid connections of cables with 250 Amp MCCB's
External Sub-Station & allied works Supply, installation, testing and commissioning of 250 KVA Sub Station (11/0.433) 3 phase copper wound outdoor type transformer oil immersed ONAN cooled/dry cooled complete with all fittings Make:AE/Electric Field/ABB Complete SITC of Sub station as per JKPDD Standards (Complete job)
Supply, installation, testing and commissioningof 11 kV line on 9 Mt. ST poles with ACSR Rabbit conductor with 52 Mt. span as per JKPDD standards ( Complete job)
Harish Kohli
SURINDER KUMAR PACHNANDA
Sanjiv Kumar Sharma
MS Anil Kumar Kapahi Contractor
A B ENTERPRISES
NPCC LIMITED
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .