Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.3 CrAccepted-AOC | ₹3.3 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹3.4 Cr+₹6.6 L (2.00%)Rejected-AOC TANGLA UDALGURI ASSAM | UDALGURI | ASSAM | 784113 | ₹3.4 Cr+₹6.6 L (2.00%) | L2 | Rejected-AOC L2 |
| 3 | L3₹3.4 Cr+₹9.6 L (2.89%)Rejected-AOC BAJUGAON CITY TOWN GOSSAIGAON P O JARAGURI P S GOSSAIGAON DIST KOKRAJHAR PIN 787000 | 787000 | ₹3.4 Cr+₹9.6 L (2.89%) | L3 | Rejected-AOC L3 |
Tender Value
₹3.3 Cr
EMD Value
₹6.6 L
Closing Date
7 Jun 2023, 1:30 pmClosed
the Addl. Chief Engineer,PWD,BTC
O/o the Addl. Chief Engineer,PWD,BTC
Repair and Renovation of Cultural Complex including Development Works at Mushalpur, Baksa under SOPD fund for the year 2022-23.TN_11_16
2023_BTC_30900_1
No. ACE- 106/PWD/IFB/2021-22/240
Open Tender
Civil Works - Building
Item Rate
365 days
baksa
Please refer Tender documents.
4 documents required · 4 mandatory
₹6,700
₹6.6 L
Yes
O/o the Addl. Chief Engineer,PWD,BTC
2 Nov 2023
19 May 2023
7 Jun 2023
19 May 2023
7 Jun 2023
19 May 2023
19 May 2023 - 3 Jun 2023
3 Jun 2023
Amount
(A) Cultural Complex 2.8 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 2.8.1 All kinds of soil.
2.25(a) Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete.
2.27 Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
2.28 Surface dressing of the ground including removing vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m. 2.28.1 All kinds of soil
2.34 Supplying chemical emulsion in sealed containers including delivery as specified. 2.34.1 Chlorpyriphos/ Lindane emulsifiable concentrate of 20%
2.35.3 Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: 2.35.3.1 With Chlorpyriphos/Lindane E.C. 20% with 1% concentration
4.1 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 4.1.8 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size)
4.10 Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources)
4.12 Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer's specification.
4.17 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
6.44 Brick edging 7cm wide 11.4 cm deep to plinth protection with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 including grouting with cement mortar 1:4 (1 cement : 4 fine sand).
SHUTTERING WORKS 5.9 Centering and shuttering including strutting, propping etc. and removal of form for: Centering and shuttering including strutting, propping etc. and removal of form for 5.9.1 Foundations, footings, bases of columns, etc. for mass concrete
5.9.5 Lintels, beams, plinth beams, girders, bressumers and cantilevers
5.9.6 Columns, Pillars, Piers, Abutments, Posts and Struts
5.9.19 Weather shade, Chajjas, corbels etc., including edges
5.22 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. 5.22.6 Thermo-Mechanically Treated bars of grade Fe-500D or more
5.22A Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. 5.22A.6 Thermo-Mechanically Treated bars of grade Fe-500D or more.
Conference Hall & Coffee Stall
5.33 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. 5.33.1 All works upto plinth level 5.33.1.1 Concrete of M25 grade with minimum cement content of 330 kg /cum
5.33.2 All works above plinth level upto floor V level 5.33.2.1 Concrete of M25 grade with minimum cement content of 330 kg /cum
10.31 Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 35x35x5 mm, joints mitred and welded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existing T-iron frame or to the wall with dash fastener, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of Engineer-In-charge.
MASONARY WORK 6.1 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: 6.1.2 Cement mortar 1:6 (1 cement : 6 coarse sand)
6.13 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. 6.13.2 Cement mortar 1:4 (1 cement :4 coarse sand)
CLADDING WORK 8.31 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
WOOD WORK 9.1 Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). 9.1.2 Sal wood
9.21 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 9.21.2 30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
9.22 Extra for Providing and fixing flush doors with decorative veneering instead of non decorative ISI marked flush door shutters conforming to IS: 2202 (Part I) 9.22.1 On one side only
9.48 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. 9.48.2 Fixed to openings /wooden frames with rawl plugs screws etc.
ANODISED ALUMINIUM FITTINGS (ALL FITTINGS SHALL BE ISI 9.96 Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : Sliding door bolts 9.96.2 250x16 mm
9.97 Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : Tower bolts 9.97.1 300x10 mm
Tower bolts 9.97.4 150x10 mm
9.100 Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : Door handle 9.100.1 125 mm
9.119 Providing and fixing factory made P.V.C. door frame of size 50x47 mm with awall thickness of 5 mm, made out of extruded 5mm rigid PVC foam sheet, mitred at corners and joined with 2 Nos of 150 mm long brackets of 15x15 mm M.S. square tube, the vertical door frame profiles to be reinforced with 19x19 mm M.S. square tube of 19 gauge, EPDM rubber gasket weather seal to be provided through out the frame. The door frame to be fixed to the wall using M.S. screws of 65/100 mm size, complete as per manufacturer’s specification and direction of
9.120 Providing and fixing factory made panel PVC door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 19 mm x 19 mm for styles and 15x15 mm for top & bottom rails. M.S. frame shall have a coat of steel primers of approved make and manufacture. M.S. frame covered with 5 mm thick heat moulded PVC 'C' channel of size 30 mm thickness, 70 mm width out of which 50 mm shall be flat and 20 mm shall be tapered in 45 degree angle on both side forming styles and 5 mm thick, 95 mm wide PVC sheet out of which 75mm shall be flat 9.120.2 30 mm thick pre laminated PVC door shutters
STEEL WORK 10.16 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. 10.16.1 Hot finished welded type tubes
FLOORING 11.3 Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 11.3.1 40 mm thick with 20 mm nominal size stone aggregate
11.26 Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 11.26.1 25 mm thick
11.27 Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.
WOODEN FLOORING 11.33 25 mm wooden planking, tongued and grooved in flooring, including fixing with iron screws complete with : 11.33.2 Second class deodar wood
11.39 Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), jointing with grey cement slurry @
11.41 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm 11.41.2 Size of Tile 600x600 mm
ROOFING 12.45 Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm 12.45.1 12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part I) :2011 (Board with BIS certification marks)
12.45.4 Fully Perforated Gypsum Plaster Board of size 1200 x 2400x12.5 mm having approx. 15 % perforated area with perforation size and pattern as approved by the Engineerin-charge and as per manufacturer's specification, with all 4 side tapered and backed by acoustical tissue with NRC value not less than 0.60
12.50 Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineerin-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto
12.51 Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : 12.51.1 Ridges plain (500 - 600mm)
FINISHING 13.1 12 mm cement plaster of mix : 13.1.1 1:4 (1 cement: 4 fine sand)
13.2 15 mm cement plaster on the rough side of single or half brick wall of mix : 13.2.1 1:4 (1 cement: 4 fine sand)
13.42 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification. 13.42.1 Two or more coats on new work
13.43 Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : 13.43.1 Water thinnable cement primer
13.48A Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives. 13.48A.1 New work (Two or more coats applied @ 1.43 litre/ 10 sqm. Over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm.
13.48 Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : 13.48.2 Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/10 sqm of approved brand and manufacture
13.48.3 Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/ 10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand and manufacture
13.67 Varnishing with varnish of approved brand and manufacture : 13.67.1 Two or more coats of glue sizing with copal varnish over an under coat of flatting varnish
13.69 Polishing on wood work with ready mixed wax polish of approved brand and manufacture : 13.69.1 New work
13.80 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
ALUMINIUM WORK 21.1 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : 21.1.1 For fixed portion 21.1.1.1 Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15)
21.1.2 For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) 21.1.2.1 Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15)
21.3 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): 21.3.1 With float glass panes of 4.0 mm thickness (weight not less than 10kg/sqm)
19.32 Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. 19.32.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
10.28 Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with
Fire Fighting Downcomer System @Rs.400/Sqm for Area =1210 Sqm
Internal Water Supply and Sanitary Installation Sanitary Fixture 17.1 Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litres low level white P.V.C. flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: 17.1.1 White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests
17.2 Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : 17.2.1 W.C. pan with ISI marked white plastic seat and lid
17.7 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: 17.7.1 White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps
17.10 Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : 17.10.2 Kitchen sink without drain board 17.10.2.2 610x460 mm bowl depth 200 mm
17.28 Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. 17.28.1 Semi rigid pipe 17.28.1.1 32 mm dia
17.29 Providing and fixing 100 mm sand cast Iron grating for gully trap.
17.31 Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
17.34 Providing and fixing toilet paper holder : 17.34.1 C.P. brass
17.70 Providing and fixing PTMT Bottle Trap for Wash basin and sink. 17.70.1 Bottle trap 31mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 gms
17.71 Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms.
17.72 Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms.
C.P.V.C. PIPES 18.9 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 18.9.8 80 mm nominal dia Pipes
18.9.9 100 mm nominal dia Pipes
WATER SUPPLY 18.8 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 18.8.1 15 mm nominal dia Pipes
18.8.2 20 mm nominal dia Pipes
18.10 Providing and fixing G.I. pipes complete with G.I. fittings and clamps, including cutting and making good the walls etc.(Internal work) Internal work - Exposed on wall 18.10.1 15 mm dia nominal bore
18.10.3 25 mm dia nominal bore
18.10.4 32 mm dia nominal bore
18.10.5 40 mm dia nominal bore
18.10.6 50 mm dia nominal bore
External Work: 18.12.6 50 mm dia nominal bore
18.13 Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : 18.13.2 50 to 80 mm nominal bore
18.17 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 18.17.1 25 mm nominal bore
18.17.2 32 mm nominal bore
18.17.3 40 mm nominal bore
18.17.4 50 mm nominal bore
18.18 Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 18.18.3 25 mm nominal bore
18.19 Providing and fixing gun metal non- return valve of approved quality (screwed end) : 18.19.4 50 mm nominal bore 18.19.4.1 Horizontal
18.22 Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 18.22.1 100 mm diamete
18.41 Providing and filling sand of grading zone V or coarser grade, allround the G.I. pipes in external work : 18.41.6 50 mm diameter pipe
18.49 Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : 18.49.1 15 mm nominal bore
18.52 Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. 18.52.1 15 mm nominal bore
18.53 Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 18.53.1 15mm nominal bore
18.58 Providing and fixing PTMT grating of approved quality and colour. 18.58.1 Circular type 18.58.1.1 100 mm nominal dia
18.48 Providing and placing on terrace (at all floor levels) polythene water storage tank of approved brand and manufacture with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
12.41 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 12.41.2 110 mm diameter
12.43 Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 12.43.2 110 mm
INTERNAL ELECTRIFICATION 1.1 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. 1.1.1 Group A
1.1.2 Group B
1.1.3 Group C
1.6 Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 2 Nos. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
1.7 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. 1.7.1 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
1.7.2 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
1.7.3 2 X 4 sq. mm + 1 X 4 sq. mm earth wire
1.7.9 4 X 6 sq. mm + 2 X 6 sq. mm earth wire
1.7.10 4 X 10 sq. mm + 2 X 6 sq. mm earth wire
1.24 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 1.24.1 5/6 A switch
1.24.3 15/16 A switch
1.24.4 3 pin 5/6 A socket outlet
1.24.5 6 pin 15/16 A socket outlet
1.25 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required
1.34 Supplying and fixing brass batten/ angle holder including connection etc. as required.
2.2 Providing and fixing following rating and breaking capacity and pole MCCB with thermo magnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 2.2.4 150 A, 16 KA,TPMCCB
2.3 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 2.3.3 12 way , Double door
2.4 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 2.4.1 4 way (4 + 12), Double door
2.10 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 2.10.1 Single pole
2.10.3 Double pole
2.10.5 Triple pole and neutral
5.2 Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
5.7 Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required.
7.1 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. 7.1.2 Above 35 sq. mm and upto 95 sq. mm
14/MR: Supplying with fitting fixing of AC ceiling fan complete with all accessories like down rod, canopy etc. 1200mm sweep ( Usha/Bajaj) make
15/MR: Supplying with fitting fixing of 20 Watt LED tube light luminaries.
16/MR:Supplying with fitting fixing of 9 Watt LED bulb luminaries.
17/MR: Supplying with fitting fixing of AC exhaust fan. 300mm sweep (Usha/Bajaj) make.
18/MR: Supplying with fitting fixing of 15 Watt LED Ultra Slim recess mounting round LED down lighter. (Orient/Bajaj/Hevels make)
19/MR: Supplying with installation testing and commissioning of Hi-wall 3 star rating Split type air conditioner of following capacity with cordless remote complete with copper pipe and electrical connect ion etc. as required complete and as directed by the Department. 2.0 Ton Capacity Voltus make (Delux)
20/MR: 1.5 Ton Capacity Voltus make (Delux)
21/MR: Supplying with fitting and fixing of 4KVA voltage stabilizer of following specification complete with necessary electrical connection etc. as required and as directed by the Department. (4.0KVA, 150-280Volt capacity).
22/MR: Supplying with fitting and fixing of 3KVA voltage stabilizer of following specification complete with necessary electrical connection etc. as required and as directed by the Department. (3.0KVA, 150-280Volt capacity).
23/MR: Supplyingincluding installation, commissioning of vermin and dust proof totally enclosed, phosphatised powder painted cubical outdoor type floor mounting compartmentalize panel board of size 0.80M(B) x 0.90M(H) x 0.40 M(D) made of 16SWG thick CR sheet and 35mm x 35mm x 5mm size angle having 4 legs at the bottom. The panel board is to be erected in 1:3:6 PCC foundation including brick soiling / grounting etc. complete neatly wiring done with provision for 1No. 250A 4pole MCCB as incomer and outgoing as specified and directed by the Department conforming to IP 43 protection comprising of the following electrical items :- 1)30mm x 5mm.4Strip copper Bus-bar 2)Pilot lamp integral Ckt. LED (RYB) (Incoming & Outgoing switch Gear of reqd. rating will be measured and paid separately).
EXTERNAL ELECTRIFICATION 2.2 Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required 2.2.3 150 A, 16 KA,TPMCCB
2.10 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 2.10.3 Double pole
5.2 Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required
5.7 Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required.
7.1 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Upto 35 sq. mm
12.22 Erection of ACSR conductor of 7/3.35 mm to 7/4.00 diameter and above including binding etc. as required.
13.1 Supplying and erection of galvanised stay set for 11 KV over head lines complete with 19/ 20 mm dia X 1.8 metres long stay rod, anchor plate of size 45 cm X 45 cm X 7.5 mm thick, thimble, stay clamps, turn buckle ( 20 mm X 600 mm ), 7/ 4.00 mm dia G.I. stay wire and 11 KV strain insulator etc in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling etc. as required.
13.10 Supplying and erection of 11 KV pin insulator complete with large steel head G.I. pin, nuts, washers etc. as required.
13.11 Supplying and erection of 11 KV disc insulator for 11 KV over head lines with galvanised insulator fittings, ball and socket type and complete with galvanised strain clamps, bolts, nuts, washers etc. as required.
13.25 Supplying and erection of single piece nonlinear resistor type lightning arrestor suitable for 3 wire, 33 KV overhead lines with rated voltage 30 KV (rms) with a nominal discharge current rating of 10 KA (station class) and complete with galvanised clamping arrangement, G.I. bolts, nuts, washers etc. as required.
11/MR: Supplying, installation, testing and commissioning of the 100KVA, 11/0.433 KV copper wound outdoor type oil filled 4Star Transformer complete including all accessories.
12/MR: Supplying including erection of 12.00meter Steel tubular pole along with fitting fixing, excavation work foundation of bolts and nuts in RCC work in 1:3:6 proportion of 1.80 mtr. Depth cement concrete.
13/MR: Supplying and fitting fixing of 11KV D.O. fuse 200A assembly as required and as directed by the Department. (Rate as per APDCL)
14/MR: Supplying and fitting fixing Of 11KV gang operated switch 200A with all accessories complete as required.
15/MR: Supplying power control copper cable, solid copper conductor up to 6.0 sq. mm. balance stranded XLPE insulated cores laid up PVC tape inner sheathed for Multicore cables, Unarmoured / armoured galvanizes wire for cables up to 10x1.5 sq. mm. ,8x2.5 sq. mm. 2x10 sq. mm., 3x10 sq. mm., 4x6 sq. mm. balance all galvanized steel vstrip) extruded PVC type ST2 sheathed, 650/1100 V gd as per IS 7098 (Part-I) 1988 (Hevels, RR, or equivalent) 2.5 sq. mm. 10 Core copper cable.
16/MR: 3Phase 4w combined CT/PT accuracy Class 0.5, 300/5A. STC :18.1KA (Rate as per APDCL)
17/MR: Supplying including erection of 7.00 meter G.I. Octagonal pole with single Arm bracket of required size along with fitting fixing, excavation work, foundation of bolts & nuts in RCC work in 1:3:6 protection of 1.00 Mtr. Depth cement plastering etc. complete with all necessary materials as required and specified by the Department.
18/MR: DTR Fencing as per REC standard specification complete with all materials & labour (Rate as per APDCL)
19/MR: 3 Phase 4wire ICS DLMS compliant LT Tri vector energy meter. Rate as per APDCL)
20/MR: Supplying including erection of 7.00 meter G.I. Octagonal pole with double Arm bracket of required size along with fitting fixing, excavation work, foundation of bolts & nuts in RCC work in 1:3:6 protection of 1.00 Mtr. Depth cement plastering etc. complete with all necessary materials as required and specified by the Department.
21/MR: Supplying of following size PVC/XLPE insulated and PVC sheathed 1.1 KV Gd. Solid aluminium conductor up to 10sq.mm. balance stranded conductor XLPE insulated cores laid up PVC tape inner sheathed Armour (aluminium wire for single core up to 70 sq.mm. balance aluminum strip Galvanized wire for cable up to 2x10 sq.mm., 3x10sq.mm., 4x6sq.mm. and balance all galvanized steel strip, extruded PVC type ST2 sheathed armoured U.G. cable as specified and as directed by the Department. (HEVELS/RR or equivalent) (1)4.00 sq.mm 2Core U.G. cable
(2)6.00 sq.mm. 2Core U.G. cable
(3)10.00sq.mm. 2Core U.G. cable.
(4)95.00sq.mm 3&1/2CoreU.G.cable
22/MR: Supplying with fitting and fixing highly effective front open able 45Watt IP66 Street light/Campus light aluminium pressure dia.-cost housing, toughened glass in the front and peanut lens for bat wing light distribution to insure uniform light distribution, higher spacing between poles and maintenance free system etc. as required and as directed by the Department. (Ories/Bajaj Hevels or equivalent). (Orient make 45Watt Street light/Campus light)
23/C.E Approved rate: Payment to be made to APDCL authority for load security, Meter security and service connection charge.
Development Work External Sewarage Line upto Septic tank
Filter Water Supply upto 100mm dia upto Overhead Tank
Horiculture Work Horiculture operation including 300mm earth filling, grassing, tree plantation/shrubs and potted plants atc.
Conference Hall Supplying, Installation, Testing, & Commissioning of Audio visual/ conference system (Carpet Area=72 Sqm)
Septic Tank (50 Users/ 3 Nos) Earth work in excavation by mechanical means (Hydraulic excavation) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 2.8.1 All kinds of soil.
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Extra for every additional lift of 1.5 m or part thereof... 2.26.1 All kinds of soil
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 4.1.8 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size)
Centering and shuttering including strutting, propping etc. and removal of form for 5.9.1 Foundations, footings, bases of columns, etc. for mass concrete
5.9.3 Suspended floors, roofs, landings, balconies and access platform
Edges of slabs and breaks in floors and walls 5.9.16.1 Under 20 cm wide
Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. 5.22.6 Thermo-Mechanically Treated bars
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: 6.1.2 Cement mortar 1:6 (1 cement : 6 coarse sand)
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 11.3.1 40 mm thick with 20 mm nominal size stone aggregate
12 mm cement plaster finished with a floating coat of neat cement of mix : 13.7.1 1:3 (1 cement: 4 fine sand)
6 mm cement plaster to ceiling of mix : 13.16.1 1:3 (1 cement : 3 fine sand)
Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910, on 12 mm dia steel bar conforming to IS: 1786……………………………………….
Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shat with bricks of class designation 75 and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. 19.32.1 With F.P.S Bricks
Providing and Placing in position suitable PVC water stops conforming to IS:12200 for construction/ expansion joints between two RCC members and fixed to the reinforcement with binding wire before pouring concrete etc. complete : 22.4.2 Dumb bell with central bulb (180 mm wide, 8 mm thick)
Constructing brick masonry circular type manhole 0.91 m internal dia at bottom and 0.56m dia at top in cement mortar 1:4 (1 cement : 4 coarse sand), inside cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement, foundation concrete 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size), and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement, all complete as per standard design : 19.9.1 0.91 m deep with S.F.R.C. cover and frame (heavy duty, HD-20 grade designation) 560 mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182 kg., fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all complete.(Excavation, foot rests and 12mm thick cement plaster at the external surface shall be paid for separately) : 19.9.1.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Extra depth for circular type manhole 0.91m internal dia (at bottom) beyond 0.91 m to 1.67 m 19.10.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer's specification.
5.9.18 Small surfaces as cantilever edgs, brackets and ends of steps, caps…………..
Providing and fixing soil, waste and vent pipes : 75 mm diameter : 17.35.2.1 Sand cast iron S&S pipe as per IS: 1729
Providing and fixing plain bend of required degree. 75 mm dia 17.39.2.1 Sand cast iron S&S as per IS -1729
Furniture Auditorium Hall a) Supplying of Auditorium Chair set of three seats for Audience approved make including fitting fixing at site all complete as per direction of Engineer-in-charge.
b) Supplying high back chair of approved make for stage including fitting fixing at site all complete as per direction of engineer-in-charge.
c) Supplying auditorium long table of approved make for stage including fitting fixing at site all complete as per direction of engineer-in-charge.
d) Supplying Lecture Stand including fitting fixing at site all complete as per direction of engineer-in-charge.
(B) BOUNDARY WALL EARTH WORK 2.8 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 2.8.1 All kinds of soil.
PLAIN CEMENT CONCRETE WORKS 4.1 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 4.1.8 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate
SHUTTERING WORKS 5.9 Centering and shuttering including strutting, propping etc. and removal of form for: 5.9.1 Foundations, footings, bases of columns, etc. for mass concrete
5.9.5 Lintels, beams, plinth beams, girders, bressumers and cantilevers
5.9.6 Columns, Pillars, Piers, Abutments, Posts and Struts
5.22 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and
5.22A Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and
5.33 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced 5.33.1 All works upto plinth level
5.33.2 All works above plinth level upto floor V level
STONE WORK 7.2 Random rubble masonry with hard stone in superstructure above plinth level and upto floor five level, including leveling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) at window sills, ceiling level and the like. 7.2.1 Cement mortar 1:6 (1 cement : 6 coarse sand)
STEEL WORK 10.25 Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and 10.25.2 In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
FINISHING 13.1 12 mm cement plaster of mix : 13.1.1 1:4 (1 cement: 4 fine sand)
13.2 15 mm cement plaster on the rough side of single or half brick wall of mix : 13.2.1 1:4 (1 cement: 4 fine sand)
13.48A Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives. 13.48A.1 New work (Two or more coats applied @ 1.43 litre/ 10 sqm. Over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm.
FENCING 16.70 Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-charge.
Pabitra Boro
Marjit Basumatary
stage.html
html • 0.04 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .