Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.6 LAccepted-AOC | ₹7.6 L | L1 | Accepted-AOC L1 Bidder |
| 2 | L2₹7.9 L+₹33,006.96 (4.34%)Rejected-AOC | ₹7.9 L+₹33,006.96 (4.34%) | L2 | Rejected-AOC L2 Bidder |
| 3 | L3₹8.4 L+₹80,206.96 (10.6%)Rejected-AOC | ₹8.4 L+₹80,206.96 (10.6%) | L3 | Rejected-AOC L3 Bidder |
| 4 | L4₹8.9 L+₹1.3 L (16.8%)Rejected-AOC | ₹8.9 L+₹1.3 L (16.8%) | L4 | Rejected-AOC L4 Bidder |
| 5 | L5₹9.5 L+₹1.9 L (25.4%)Rejected-AOC | ₹9.5 L+₹1.9 L (25.4%) | L5 | Rejected-AOC L5 Bidder |
| Sl No | Description | Qty | Unit | SHIVAM ENTERPRISES L4 | VNK INFRA L3 | PAL GULHARE CONSTRUCTIONS L5 | RAJ ENTERPRISES L2 | Rajesh Jayantilal Mehta L6 | ANUPAM CONSTRUCTION L1 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Glass Doors - Providing and fixing 12 mm thick toughened glass door of approx size 900mm x 2100mm or any other size as per site requirement as directed by Bank's engineer, of approved make with edges properly finished and fixed over the on floor spring of capacity of minimum 80Kg of approved make with top pivot arrangements, floor spring shall be firmly installed in the floor by making cutting of exact size required(Basic rate of floor spring to be considered as Rs 6500/- per Each excluding GST), providing and fixing SS 304 grade handle of approved design, shape and of size 600mm (Basic rate of handle to be considered as Rs 3500/- for one set excluding GST), providing and fixing approved make and design dead lock with key covers(Basic rate of dead lock to be considered as Rs 2100/- for one set excluding GST), magnetic door stopper/ door stoppers at directed locations etc. Door shall be erected in perfect line and plumb, etc. complete as per specification and directed by the Banks Engineer. The rate shall also inclusive of providing & fixing approved make and pattern frosted film including scaffolding at all height,all taxes, transportation, transit insurance, loading & unloading at site etc as directed Bank's Engineer.
(for further details please refer respective Item description in the NIT and Tender specification) | 21 | Nos | 22,000 ₹5,45,160 | 22,000 ₹5,45,160 | 17,000 ₹4,21,260 Lowest | 22,000 ₹5,45,160 | 20,700 ₹5,12,946 | 20,668 ₹5,12,153.04 |
| 2.00 | Extension of cabin partition upto ceiling height : Providing and fixing aluminium pipe framing of approved make thickness 2mm of 25x50mm or other size matching to the existing partition framework as per the site requirement and direction of Bank's engineer. The pipe grid shall be perimetered along the old partition bottom, vertical corner sides and along ceiling for top portion and also ensuring that sufficient supports i.e. all corner supports and middle support (if required as per site condition) shall extends to upto RCC slab to ensure stability of structure as per the direction of site engineer.The intermediate pipe section spacing should be as per existing pipes and not be more than 2x2'. Fixing the pipe members shall be extended upto ceiling and fixed firmly with angle cleat arrangement with 8mm dia anchor fasteners or as approved by Bank's engineer at spacing of one feet to make the overall structure intact.
(for further details please refer respective Item description in the NIT and Tender specification) | 30 | SqMt | 6,000 ₹2,12,400 | 5,000 ₹1,77,000 | 9,350 ₹3,30,990 | 4,200 ₹1,48,680 Lowest | 8,100 ₹2,86,740 | 4,200 ₹1,48,680 Lowest |
| 3.00 | Making of vertical partition box at entrance for provision of door to ensure that the door of size 900mm x2100mm or any other size as per site requirement of approved make can be fixed at the entrance of cabins. The item include providing and fixing aluminium pipe 2mm thick of size 25x50mm. The partition box approx size 200-300mm width (at one side or in part on both side of door) and extented up to ceiling or as per site requirement shall be made by fixing vertical pipes upto RCC ceiling and intermediate horizontal pipes at maximum spacing of 600mm, the whole unit shall be fixed with 11mm MDF (both side)with providing rockwool/ insulation material of required thickness min 25mm, in between the partition/ MDF and 1mm laminate on both sides to match with the existing shade or as approved. The work shall include removing or cutting of gypsum or armstrong ceiling and finishing the same after making of partition etc. all complete. Fittting, fixtures shall be as mentioned in item no.2. Only one side of finished area upto false ceiling level (lower of the both side, if height is different) shall be considered for measurement for each stretch of partitionas directed. The rate shall include for scaffolding at all height,all taxes,transportation,loading and unloading, removal of debris etc as directed by Bank's Engineer.
(for further details please refer respective Item description in the NIT and Tender specification) | 20 | SqMt | 5,500 ₹1,29,800 | 5,000 ₹1,18,000 | 8,500 ₹2,00,600 | 4,200 ₹99,120 Lowest | 8,100 ₹1,91,160 | 4,200 ₹99,120 Lowest |
Tender Value
Refer Docs
Closing Date
31 Aug 2026, 2:00 pmClosed
GENERAL MANAGER(TECH)
2nd Floor, MOB, Fort, Mumbai
Providing and fixing of glass doors and extension of partitions for cabins at 20th floor Maker Tower, Mumbai
2026_RBI_288829_1
RBI/Mumbai Regional Office/Estate/26-27/ET/011
Limited
Civil Works
Works
Mumbai
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
Exempted
2nd Floor, MOB, Fort, Mumbai
9 Sept 2026
24 Aug 2026
1 Sept 2026
24 Aug 2026
31 Aug 2026
24 Aug 2026
27 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Glass Doors - Providing and fixing 12 mm thick toughened glass door of approx size 900mm x 2100mm or any other size as per site requirement as directed by Bank's engineer, of approved make with edges properly finished and fixed over the on floor spring of capacity of minimum 80Kg of approved make with top pivot arrangements, floor spring shall be firmly installed in the floor by making cutting of exact size required(Basic rate of floor spring to be considered as Rs 6500/- per Each excluding GST), providing and fixing SS 304 grade handle of approved design, shape and of size 600mm (Basic rate of handle to be considered as Rs 3500/- for one set excluding GST), providing and fixing approved make and design dead lock with key covers(Basic rate of dead lock to be considered as Rs 2100/- for one set excluding GST), magnetic door stopper/ door stoppers at directed locations etc. Door shall be erected in perfect line and plumb, etc. complete as per specification and directed by the Banks Engineer. The rate shall also inclusive of providing & fixing approved make and pattern frosted film including scaffolding at all height,all taxes, transportation, transit insurance, loading & unloading at site etc as directed Bank's Engineer.
(for further details please refer respective Item description in the NIT and Tender specification) | - | Nos | 24,000 | - |
| 2 | Extension of cabin partition upto ceiling height : Providing and fixing aluminium pipe framing of approved make thickness 2mm of 25x50mm or other size matching to the existing partition framework as per the site requirement and direction of Bank's engineer. The pipe grid shall be perimetered along the old partition bottom, vertical corner sides and along ceiling for top portion and also ensuring that sufficient supports i.e. all corner supports and middle support (if required as per site condition) shall extends to upto RCC slab to ensure stability of structure as per the direction of site engineer.The intermediate pipe section spacing should be as per existing pipes and not be more than 2x2'. Fixing the pipe members shall be extended upto ceiling and fixed firmly with angle cleat arrangement with 8mm dia anchor fasteners or as approved by Bank's engineer at spacing of one feet to make the overall structure intact.
(for further details please refer respective Item description in the NIT and Tender specification) | - | SqMt | 5,000 | - |
| 3 | Making of vertical partition box at entrance for provision of door to ensure that the door of size 900mm x2100mm or any other size as per site requirement of approved make can be fixed at the entrance of cabins. The item include providing and fixing aluminium pipe 2mm thick of size 25x50mm. The partition box approx size 200-300mm width (at one side or in part on both side of door) and extented up to ceiling or as per site requirement shall be made by fixing vertical pipes upto RCC ceiling and intermediate horizontal pipes at maximum spacing of 600mm, the whole unit shall be fixed with 11mm MDF (both side)with providing rockwool/ insulation material of required thickness min 25mm, in between the partition/ MDF and 1mm laminate on both sides to match with the existing shade or as approved. The work shall include removing or cutting of gypsum or armstrong ceiling and finishing the same after making of partition etc. all complete. Fittting, fixtures shall be as mentioned in item no.2. Only one side of finished area upto false ceiling level (lower of the both side, if height is different) shall be considered for measurement for each stretch of partitionas directed. The rate shall include for scaffolding at all height,all taxes,transportation,loading and unloading, removal of debris etc as directed by Bank's Engineer.
(for further details please refer respective Item description in the NIT and Tender specification) | - | SqMt | 5,000 | - |
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.69 MB
TenderDocument.pdf
Tender Documents • 1.22 MB
BOQ_336892.xls
BOQ • 0.42 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .