Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹22.9 LAccepted-AOC 42 INDUSTRIAL ESTATE GWALIOR MP 474004 | GWALIOR | GWALIOR | MP | 474004 | L-1 | Accepted-AOC L-1 | |
| 2 | L-2₹24.6 L+₹84,425 (3.55%)Rejected-AOC S 17 77 1 CHARAN NAGAR COLONY NADESAR VARANASI UTTAR PRADESH PIN 221002 | VARANASI | UTTAR PRADESH | 221002 | L-2 | Rejected-AOC L-2 | |
| 3 | L-3₹27.3 L+₹3.5 L (14.9%)Rejected-AOC | L-3 | Rejected-AOC L-3 | |
| 4 | L-4₹28.4 L+₹4.6 L (19.5%)Rejected-AOC | L-4 | Rejected-AOC L-4 | |
| 5 | L-5₹34.4 L+₹10.7 L (45.0%)Rejected-AOC | L-5 | Rejected-AOC L-5 |
Tender Value
Refer Docs
EMD Value
₹73,500
Closing Date
26 Feb 2022, 6:00 pmClosed
GE I RND DELHI
MILITARY ENGINEER SERVICE, GARRISON ENGINEER I RND, LUCKNOW ROAD, TIMARPUR, DELHI-110054
REPAIR/REPLACEMENT OF INTERNAL WIRING, DISTRIBUTION BOARDS, ELECTRIC FITTINGS, FIXTURES, FANS AND ALL TYPES OF DG SETS, AMF PANEL AND OTHER CONNECTED WORKS AT DRDE GWALIOR UNDER GE (I) RND DELHI
2021_MES_498390_1
GE/RND-90/GWL/2021-22
Open Tender
Civil Works
Item Rate
270 days
GE I RND DELHI
Class-D, cat b(i)
2 documents required · 2 mandatory
₹500
GE I RND DELHI
₹73,500
Yes
25 Mar 2022
30 Dec 2021
28 Feb 2022
30 Dec 2021
26 Feb 2022
14 Feb 2022
Amount
Taking down copper/aluminium point wiring (light, fan, socket or power ), including fixtures and fittings such as switches, ceiling roses, pendants, regulators, sockets, etc and making good disturbed surfaces of walls, floors etc complete all as specified and directed.
M&L for point wiring with 1.5 sqmm multi stranded PVC insulated unseathed copper conductor cable FRLS in and including PVC concealed conduit of size 20 mm dia medium grade for one light point or fan point or bell point controlled by one way switch on plastic laminated sheet 3mm thick using existing MS/CI sunken box including PVC insulated unsheathed 1.5 sqmm copper conductor FRLS continuous earth wire and connecting with earth dolly including necessary cutting chasing for concealing of conduit and making good the distrubed surface and matching with existing specifications complete all as specified and directed.
M&L for point wiring with 1.5 sqmm multi stranded PVC FRLS insulated unseathed copper conductor cable FRLS in and including PVC casing & caping of size 25 mm width for one light point or fan point or bell point controlled by one switch including PVC insulated unsheathed 1.5 sqmm copper conductor FRLS continuous earth wire and connecting with earth dolly and making good the distrubed surface and matching with existing specifications complete all as specified and directed.
M&L for point wiring for 3 pin socket outlet, 5 amps, independent, with 2.5 sqmm multi stranded PVC insulated unsheathed copper conductor FRLS cable in and including PVC conduit of size 20 mm dia medium grade plastic laminated sheet 3mm thick including PVC insulated unsheathed 2.5 sqmm copper FRLS conductor continuous earth wire and connecting with earth dolly including necessary cutting chasing for concealing of conduit and making good the distrubed surface and matching with existing specification complete all as specified and directed.
M&L for point wiring for 3 pin socket outlet, 5 amps, independent, but below the switch board of light points in the same vertical plane with 2.5 sqmm multi stranded PVC insulated unsheathed copper conductor FRLS cable in and including PVC conduit of size 20 mm dia medium grade plastic laminated sheet 3mm thick including PVC insulated unsheathed 2.5 sqmm copper FRLS conductor continuous earth wire and connecting with earth dolly including necessary cutting chasing for concealing of conduit and making good the distrubed surface and matching with existing specification complete all as specified and directed.
M & L in repair for Sub main wiring with two single core PVC FRLS insulated cable 4 sqmm (Nominal dia) copper conductor multistrand and drawing in and including PVC concealed conduit 20 mm dia medium grade ISI marked & one single core, 4 sqmm multistrand copper conductor PVC FRLS green unsheathed cable for earth continuity complete all as specified and directed. Note:- 3 run of 4 Sqmm cable and one run of PVC conduit shall be measured one unit.
M & L in repair for Sub main wiring with two single core PVC FRLS insulated cable 10 sqmm (Nominal dia) copper conductor multistrand and drawing in and including PVC casing caping 25 mm width ISI marked & one single core, 10 sqmm multistrand copper conductor PVC FRLS green unsheathed cable for earth continuity complete all as specified and directed. Note:- 3 run of 10 Sqmm cable and one run of PVC casing coping shall be measured as one unit.
M & L in repair for Sub main wiring with 4 single core PVC FRLS insulated cable 6 sqmm (Nominal dia) copper conductor multistrand and drawing in and including S&F for PVC conduit 25 mm dia medium grade ISI marked & one single core, 6 sqmm multistrand copper conductor PVC FRLS green unsheathed cable for earth continuity complete all as specified and directed. Note:- 5 run of 6 Sqmm cable and one run of PVC conduit shall be measured one unit.
M & L in repair for Sub main wiring with 4 single core PVC FRLS insulated cable 16 sqmm (Nominal dia) copper conductor multistrand and drawing in and including S&F for PVC conduit 32 mm dia medium grade ISI marked & one single core, 16 sqmm multistrand copper conductor PVC FRLS green unsheathed cable for earth continuity complete all as specified and directed. Note:- 5 run of 16 Sqmm cable and one run of PVC conduit shall be measured one unit.
S&F in replacement switch piano type 5 Amp one way AC 230 volts complete all as specified and directed.
S&F in replacement switch piano type 5 Amp two way AC 230 volts complete all as specified and as directed .
S&F in replacement of socket outlet 2in - 1, 5 Amp 3 pin AC 230 volt complete all as specified and directed.
S&F in replacement switch socket outlet 2in - 1, 6 Amp 3/5 pin AC 230 volt complete all as specified and directed.
S&F in replacement switch Socket outlet 2 in 1, 5 pin 5 Amp and 15 Amp multi purpose socket outlet AC 230 volt complete all as specified and directed.
S&F in repair ceiling rose of size 65 x 50mm 3 terminal AC 230 volt complete all as specified and directed.
S&F in repair lamp holder angle/ batten holder back light type with base plate suitable for 230 volt complete all as specified and directed.
S&F in repair door bell AC 230 volt ding dong single phase complete all as specified and directed.
S&F in repair electronic Ballast for FTL 36/40 watt 240 volts complete all as specified and directed.
S&F in repair FTL rod 36/40 watt 240 volts complete all as specified and directed.
S&F in repair LED Tubelight rod 20 watt 240 volts complete all as specified and directed.
S&F in replacement for MCB SP 6 to 32 Amps 10 KA 'C' Series,240 V complete all as specified and directed.
S&F in replacement for MCB SPN 40 to 63 Amps 10 KA , 'C' Series 240 V complete all as specified and directed.
S&F in replacement for MCB TPN 63 to 100 Amps 10 KA 'C' Series 415 Volts complete all as specified and directed.
S&F in replacement for MCCB 3 pole , 125 Amps, 415 Volts, 16 KA breaking capacity and connections including spreader terminals complete all as specified and directed.
S&F in repairs MCCB, 3 Pole ,415 V , 160 Amp with breaking capacity 36 KA incuding connected accessories, spreader terminals complete all as specified and directed.
S&F in repairs MCCB, 3 Pole ,415 V , 250 Amp with breaking capacity 36 KA incuding connected accessories, spreader terminals complete all as specified and directed.
S&F in repairs MCCB, 3 Pole ,415 V , 350 Amp with breaking capacity 36 KA incuding connected accessories, spreader terminals complete all as specified and directed.
S&F in repair metal clad socket ,two pin and earth , 20 Amps, 250 Volts suitable for metal clad sheet enclosures complete all as specified and directed.
S&F in repair metal plug top, two pin and earth , 20 Amps, 250 Volts suitable for metal clad sheet enclosures complete all as specified and directed.
S&F in repairs for sheet metal enclosures Single pole and neutral with two pin earth plug and socket with plug top including single pole MCB 20 Amps complete all as specified and as directed.
S&F in repairs for sheet metal enclosures Triple pole and earth enclosure with three pin & earth plug with socket complete including triple pole MCB 32 Amps complete all as specified and as directed.
S&F in repair sheet metal MCCB enclosures for TP/FP MCCBs with inbuilt neutral link for TPN system, IP 30 Protected complete all as specified and as directed.
S&F in repairs for sheet metal enclosures for DBs when MCB to used SPN 8 way double door powder coated factory made with separate neutral and earth links with IP 43 protection, fixed on wall /metal board/wooden board including making all incomming and outgoing connections with suitable copper lugs including disconnecting & taking out old existing enclosure complete all as specified and as directed.
All as per item srl No 33 above but SPN 12 way.
All as per item srl No 33 above but TPN 4 way.
All as per item srl No 33 above but TPN 8 way.
S&F in repair sheet metal enclosure TPN DBs 4 Way 415 Volts , vertical double door type powder coated with busbar neutral link earth rail & din rail, IP-42 Protected, ISI marked for incorporation of MCCB/ ISOLATOR/ RCB etc. Fixing testing & commissioning complete all as specified and directed.
Re-fixing of MCB/MCCB any type/any make retrieved from ser Item No. 33.00 to 37.00 complete all as specified and directed.
S&F Decorative recess mounted 35/36 watt, 220 V AC LED luminaire 600 x 600 mm , full output luminaire for modern offices with CRCA powder coated body and new generation high effciency PMMA diffuser to provide soft glare free light complete with driver,holders & LED Lamps suitable for modular / POP/ Gypsum ceiling complete including disconnecting and taking out old U/S light fittings complete all as specified and directed.
S&F Round shaped recess mounted 15 watt, 220 V AC LED luminaire , full output luminaire for modern offices with CRCA powder coated body and new generation high effciency PMMA diffuser to provide soft glare free light complete with driver,holders & LED Lamps suitable for modular / POP/ Gypsum ceiling complete including disconnecting and taking out old U/S light fittings complete all as specified and directed.
S&F surface and wall mounted 20 Watt LED tube light fitting box type with driver,holder with extruded aluminium housing provided for efficient heat dissipation with polycarbonate diffuser input voltage AC 230 V, 50 HZ complete all as specified and directed
S&F in repairs for bulk head luminarie with LED 10 watt lamps Hexagonal shaped with engineering plastic housing and frame with opal PMMA defuser complete including disconnecting and taking out old U/S light fittings all as specified and directed.
S&F in repair for energy saving decorative wall mounting LED Lighting fixtures as mirror light made out of poly corbonate with high output diffuser, 2 feet , 10 watt LED and making connections complete all as specified and directed.
S&F in repair energy saving decorative wall mounting LED lamp fitting made out of poly corbonate including 1x9/10 watt LED bulb and making connections complete all as specified and directed.
S&F in repairs plastic laminated bakelite hylem sheet of size 12 cm x 12 cm , 3mm thick, cut to required sizes and shapes including making holes and necessary cuttings for fitting of switches/ sockets/ regulators complete all as specified and directed
All as per Item No. 45 above but of size 12cm x 20cm
All as per Item No. 45 above but of size 20cm x 25cm
S&F in repair for PVC Rectangular block for mounting switches, sockets, regulators etc.with 3 mm thick plastic laminates sheet cover of size 100x100x50 mm deep complete all as specified and directed
All as per Item No. 48 above but of size 200x150x50 mm
S&F in repairs for Modular switch 1 Way 6 Amp , 1 Module AC 230 volt complete all as specified and as directed.
S&F in repairs of Modular switch 1 Way 16 Amp , 1 Module AC 230 volt complete all as specified and as directed.
S&F in repairs of Modular socket , 6 A-2/3 pin combined , 2 Module AC 230 volt complete all as specified and as directed.
S&F in repairs of Modular socket , 6 A/16 Amp -2/3 pin combined , 2 Module AC 230 volt complete all as specified and as directed.
S&F in repairs of Modular white cover plate with frame including metal flush box but 4 module complete all as specified and as directed.
S&F in repairs of Modular white cover plate with frame including metal flush box but 8 module complete all as specified and as directed.
S&F in repairs of Modular white cover plate with frame including metal flush box but 12 module complete all as specified and as directed.
S&F in repairs for LED domestic bulb 9 Watt type 240 volts complete all as specified and as directed.
M&L in repairs for rewinding of ceiling fan motor 1200mm any make of fan with super enameled copper winding wire of existing size including cutting and getting out old burnt winding, sleeve work, varnishing with E class insulation varnish, threading, connections complete all as specified and as directed.
M&L in repairs for rewinding of Exhaust fan motor 300 - 450 mm sweep with super enameled copper winding wire of existing size including cutting and getting out old burnt winding, sleeve work, varnishing with E class insulation varnish, threading, connections with three core copper flexible wire of size 40/ 0.0076 mm of length not more than one mtr. with each fan complete all as specified and as directed.
S&F in repairs ball bearing of size 6200 / 6201 complete all as specified and as directed.
All as per srl item No 60 above but size 6202.
M&L for Reshaping of mild steel shaft of ceiling fan to proper fixing the same including necessary lathe (machine) work complete all as specified and directed.
S&F in repairs of fan regulator, electronic type, AC 230 volts suitable for 1200mm/ 1400mm sweep ceiling fan, stepped range, hum free complete all as specified and as directed.
Supply and fixing in repairs capacitor AC 220 volts 2.5 to 3.15 mfd complete all as specified and as directed.
Dismantling and strip opening Water Heater 230 volts 25/35/50 Liters capacity 1500 / 2000 watt rating, taking out geyzer assembly elements and other connected accessories, descaling, cleaning of water tank, tubes assembly after repair reassembling ,Electric supply lead 3 core, flexible, PVC insulated and sheathed stranded copper conductor, 1100 Volts grade, size 2.5 Sqmm (nominal area), replacement of U/S 3 pin top 15 amp, reinstallation and connecting testing after satisfactorily serving and repairs complete all as specified and as directed. Note :- Electric cable 3 core 2.5 sq mm, Syphon assembly for item No 65.00 will be measured and paid separately under respective item of schedule complete all as specified and directed.
S&F in repairs for Syphon assembly complete suitable for 25/35 ltr water heater ISI marked complete all as specified and as directed.
S&F in repairs for Syphon assembly complete suitable for 50 ltr water heater ISI marked complete all as specified and as directed.
S&F in repairs for PVC connection heat resistant 24'' long ISI marked complete all as specified and as directed.
S&F in repairs for Sheet metal bottom cover having two halves circle complete all as specified and as directed.
S&F in repairs for Thermostat 35(R) C to 75(R) C of ISI marked complete all as specified and as directed.
S&F in repairs for Indicating lamp (LED ) red or green any shape and size matching to existing geyser complete all as specified and as directed.
S&F in repairs for Heating Element required size and shape, 2000 watt ISI marked,suitable for 25/35/50 litre water heater complete all as specified and as directed.
S&F in repair for gasket packing set suitable for 25/35/50 liter water heater complete all as specified and as directed.
S&F in repairs for glass wool superior quality for geyser including removing inner tank and refixing properly complete all as specified and as directed.
S&F in repairs 3 core, flexible, PVC insulated and round sheathed stranded copper conductor, 1100 Volts grade, size 2.5 Sqmm (nominal area) ISI marked complete all as specified and as directed.
M & L in repairs of PVC insulated twin core flexible copper conductor cable of size 40/76 gauge complete all as specified and as directed.
S & F installation , testing and commissioning in repair of pressure die-cast aluminium housing with high power LED bldg security light fitting with IP-66 , 1x 25 Watt , fixed in position with and including 40 mm dia light grade GI Pipe bracket made to shape not less than 1.2 Mtr long for mounting fitting with and including suitable size duly painted MS FI 40 x6mm clamps with nut and bolts , washers making electrical connection with and including three core 16/0.20 mm copper conductor flexible cable from connector to fitting complete all as specified and directed
S&F in repairs Decorative LED Luminaire 40 watt ,4ft x 1ft full output luminaire recess or surface mounted (with continuous mounting end cap and suspension kit with main cable) with CRCA powder coated body and new generation high effciency diffuser to provide soft glare free light for POP/ Gypsum ceiling includding necessary cutting/chasing complete including disconnecting and taking out old U/S light fittings complete all as specified and directed.
S & F in repair Post top lantern LED type 20 watt, 230 V AC, outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete including making electrical connection with three core 16/0.20 mm copper conductor flexible cable from connector to fitting complete all as specified and directed.
Supply and fixing LED flood light 100 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and directed.
M&L in repairs Earthing complete with galvanished earth plate electrode of size 600 x 600 x 6.00 mm buried directly in ground (earth pit not less than 2.25 mtr below normal ground level) with top edge of earth plate not less than 1.5 mtr below normal ground level connected to galvanised earth lead wire 4.00 mm dia by means of bolts, nuts, check nuts and galvanised iron or steel including earth work in any type of soil, GI funnel with GI mesh charcoal salt 15cm alternate layer and around the earth plate as shown in electrical plate no 3 of SSR Part I 2010, 20 mm dia watering pipe medium grade 1.70 mtr long GI protection pipe light grade 15mm dia from earth pit to main board & testing on completion:- (a) GI wire 4 mm dia (b) Watering pipe GI medium grade 20mm dia from top of the earth electrode up to MS funnel with wire mesh embeded in floor of PCC earth pit. (GI Funnel should properly tightned on GI watering pipe and embeded in PCC floor of earth pit with open top suitable for watering of earth pits) (c) Excavation & earthwork in any type of soil PCC earth pit 30x30x30cm constructed in PCC 1:2:4 type B1 exposed surfaces smoothly finished with 15mm thick plaster in cement mortar 1:6 including RCC pit cover 50mm thick 1:2:4 type B1 reinforced with 8mm dia steel TMT bar 75mm centre to centre with 2 Nos MS handles of 12mm dia suitable for carrying of pit cover.
M&L in repairs Earthing complete with galvanished earth plate electrode of size 600 x 600 x 6.00 mm buried directly in ground (earth pit not less than 2.25 mtr below normal ground level) with top edge of earth plate not less than 1.5 mtr below normal ground level connected to galvanised iron earth strip 25 x 4mm as earthing lead by means of bolts, nuts, check nuts and galvanised iron or steel including earth work in any type of soil, GI funnel with GI mesh charcoal salt 15cm alternate layer and around the earth plate as shown in electrical plate no 3 of SSR Part I 2010, 20 mm dia watering pipe medium grade 1.70 mtr long GI protection pipe light grade 40mm dia from earth pit to main board & testing on completion:- (a) GI earth strip 25x4mm (b) Watering pipe GI medium grade 20mm dia from top of the earth electrode up to MS funnel with wire mesh embeded in floor of PCC earth pit. (GI Funnel should properly tightned on GI watering pipe and embeded in PCC floor of earth pit with open top suitable for watering of earth pits) (c) Excavation & earthwork in any type of soil PCC earth pit 30x30x30cm constructed in PCC 1:2:4 type B1 exposed surfaces smoothly finished with 15mm thick plaster in cement mortar 1:6 including RCC pit cover 50mm thick 1:2:4 type B1 reinforced with 8mm dia steel TMT bar 75mm centre to centre with 2 Nos MS handles of 12mm dia suitable for carrying of pit cover.
M&L in repairs earthing complete with Copper earth plate electrode of size 600 x 600 x 3.15 mm buried directly in ground (earth pit not less than 2.25 mtr below normal ground level) with top edge of earth plate not less than 1.5 mtr below normal ground level connected to Copper earth lead 20x3mm as earth lead a by means of bolts, nuts, check nuts and galvanised iron or steel including earth work in any type of soil, GI funnel with GI mesh charcoal salt 15cm alternate layer and around the earth plate as shown in electrical plate no 3 of SSR Part I 2010, 20 mm dia watering pipe medium grade 1.70 mtr long GI protection pipe light grade 40mm dia from earth pit to main board & testing on completion :- (a) Copper Earth Lead 20x3mm (b) Watering pipe GI medium grade 20mm dia from top of the earth electrode up to MS funnel with wire mesh embeded in floor of PCC earth pit. (GI Funnel should properly tightned on GI watering pipe and embeded in PCC floor of earth pit with open top suitable for watering of earth pits) (c) Excavation & earthwork in any type of soil PCC earth pit 30x30x30cm constructed in PCC 1:2:4 type B1 exposed surfaces smoothly finished with 15mm thick plaster in cement mortar 1:6 including RCC pit cover 50mm thick 1:2:4 type B1 reinforced with 8mm dia steel TMT bar 75mm centre to centre with 2 Nos MS handles of 12mm dia suitable for carrying of pit cover.
M&L for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or burried in ground or drawn in conduit / pipe or fixed to poles or any other indicated situation for loop earthing etc as required with 20x3 mm copper strip complete all as specified and directed.
S&F in replacement for 3 pole AC control power contractor,415 volts, . Phase 50 hz rated operational current 70 TO 100 amp. & AC 3 rating confirming to IEC-60947 in AMF Panel complete all as specified and directed.
S & F in replacement of 3 pole AC control power contractor,415 volts, . Phase 50 hz rated operational current 200 amp. & AC 3 rating confirming to IEC-60947 in AMF Panel complete all as specified and directed.
S & F in replacement of 3 pole AC control power contractor,415 volts, . Phase 50 hz rated operational current 260 AMP TO300 amp. & AC 3 rating confirming to IEC-60947 in AMF Panel complete all as specified and directed.
S & F in replacement of 3 pole AC control power contractor,415 volts, . Phase 50 hz rated operational current 400 amp. & AC 3 rating confirming to IEC-60947 in AMF Panel complete all as specified and directed.
S & F in replacement of 3 pole AC control power contractor,415 volts, . Phase 50 hz rated operational current 630 amp. & AC 3 rating confirming to IEC-60947 in AMF Panel complete all as specified and directed.
S & F in replacement of contactor coil MNX-140 complete all as specified and directed.
S&F in replacement of AVR suitable for 160 KVA capacity DG set complete all as specified and directed.
S&F AVR suitable for 250/320 KVA capacity DG set complete all as specified and directed.
S&F in replacement of existing voltage relay 415 volt 3 phase complete all as specified and directed.
S&F in replacement of multi control relay as per existing sample complete all as specified and directed. .
S&F in replacement of MCCB ,four pole 100 Amp current rating and ultimate breaking caapacity LCS=100 % Icu 16 KA with thermal magenetic realese and adjustable overload setting confirming to IS 13947 & IEC- 60947 complete all as specified and directed .
S&F in replacement of MCCB ,four pole 160 Amp current rating and ultimate breaking caapacity LCS=100 % Icu 36 KA with thermal magenetic realese and adjustable overload setting confirming to IS 13947 & IEC- 60947 complete all as specified and directed .
S&F in replacement of MCCB ,four pole 250 Amp current rating and ultimate breaking caapacity LCS=100 % Icu 36KA with thermal magenetic realese and adjustable overload setting confirming to IS 13947 & IEC- 60947 complete all as specified and directed .
S&F in replacement of off load change over switch 4 pole 415 volts 100 Amp rating advance neutral, open execution handel assembly having door interloc and padlocking arrangement complete all as specified and directed.
S&F in replacement of off load change over switch 4 pole 415 volts 200 Amp rating advance neutral, open execution handel assembly having door interloc and padlocking arrangementcomplete all as specified and directed.
S&F in replacement of off load change over switch 4 pole 415 volts 400 Amp rating advance neutral, open execution handel assembly having door interloc and padlocking arrangement complete all as specified and directed.
S&F in replacement of digital voltmeter (0.5) 3 phase 0 to 500 volts mains opetated having 2.5 digit LED/LCD/FND display mounting type for measuring phase volts complete all as specified and directed.
S&F digital ammeter (0.5) 3 phase digital meter range 0-300 Amp along with suitable size CTs having 3.5 digit LED/LCD/FND display mounting type for measuring phase volts complete all as specified and directed.
S&F in replacement of digital frequency meter (0.2) having LED/LCD/FND display mounting type for 50-60 hz complete all as specified and directed.
S&F in replacement of self sequentional starting relay unit 24 volts DC with dual interlocking timer for self on ,(3 sec-15 sec) adiacent independently with another timer for set fails to starety alarm complete all as specified and directed.
S&F in replacement of Led illuminating flush push buttons 22.5 mm dia in three colour as red ,yellow & blue without contact block and carrier complete all as specified and directed.
S&F in replacement of Led pilot lamp head 22.5 mm dia in three colours as red, yellow. And blue without contact block and carriers complete all as specified and directed.
S&F in replacement of plug in relay universal type 11 pin contact rating 10 amps 24 volts DC and mechenical indicator with manual testing /latching lever complete all as specified and directed.
S&F in replacement of plug in relay universal type 11 pin contact rating 10 amps 24 volts AC and mechenical indicator with manual testing /latching lever complete all as specified and directed.
S&F in replacement of plug in relay universal type 11 pin contact rating 10 amps 230 volts DC and mechenical indicator with manual testing /latching lever complete all as specified and directed.
S&F in replacement of of self starter 24 volts type SM-130-24 volts7.5 KW cat part no. 269225116A complete all as specified and directed.
S&F in replacement of of self starter 12 voltsSuitable for DG set 160/250/320 KVA complete all as specified and directed.
S&F in replacement of maintence free battery 12 volts,180 AH complete all as specified and directed.
S&F in replacement of battery charger auto type 24 volts x 10 amps complete with all accessories complete all as specified and directed.
S&F in replacement of battery charger auto type 12 volts x 8amps complete with all accessories complete all as specified and directed.
Dismantling and opening of turbo charger assembly of 160 to 320 KVA DG Set and repair/overhauling and replacement of turbo charger kit including refixing, testing complete all as specified and directed.
Blank
Blank
M&L for battery lead heavy duty multi strands copper conductor size 25 sq mm 4 feet long in red and black colour complete all as specified and directed.
M&L for replacement of heavy duty brass terminals suitable for 24 volts /12 volts batteries complete all as specified and directed.
S& F of flywheel ring for 160 KVA to 320 KVA capacity DG Set complete all as specified and directed.
M&L for repair to 24 volts self starter assembly by taking out from DG Set of any make and size including transporting the same to work shop in market for repair . The following spare parts are replaced by new one like armature, field coil with enameled copper conductor of existing gauge including insulating material and heat varnish ,DE bearing bush, CE bush armature, carboun brush including petrol wash all as specified. Refixing the same after repair and testing on full load complete all as specified and directed.
Description all as per item no. 122 above but for 12 volts self starter assembly.
M&L for Repair/servicing of radiator assembly of 160/250/320 KVA DG Set after dismanteling and removing cooling fans, guard plates and lowering the same from engine after draining out water from radiator and scrapping / removing sludge / scale inside tank with acid including replacement MS tank (botom portion) at rusted portion by cutting/ welding / brazing with 2mm thick copper plate including painting. Remounting the same at its original position and repalcement of pre mixed coolent as per the ratio fixed by manufacturer and testing complete all as directed. (Note- Pre mixed coolent shall be measured and paid separately under relevant item of schedule)
M&L for servicing /preventive maintence of DG set of capacity 160KVA to 320 KVA at site comprising of the following check & re adjust valve tapped clearence in cold ,drain out used engine oil by opening the oil chamber ,cleaning the chamber throughly, pouring the new engine oil refixing the chamber cover with new gasket , replacement of diesel filter ,oil filter, air filter,cleaning the diesel tank, clean radiator fins & air to air after coller & AVM pads , check rubber seal and hose pipes replace if found defective , check coupling disc on injection pump, check speed governer for proper functioning and lubricating linkages, check clean air filter element ,check functioning of engine protection unit repair to instruments panel, Check and repair of any leakage etc.and replacement of small minor items such as nut, bolts, washers, etc aren included in quoted rates of sch A' . The above cheks are stictly followed in the duration of six month interval of every 250 hrs of run complete all as specified and directed. Note: Engine oil and filters shall be measured & paid separately under respective items.
Supply only Fuel Filter 160 KVA to 320 KVA complete all as specified and directed.
Supply only Pre fuel filter for 160 KVA to 320 KVA complete all as specified and directed.
Supply only Air clean element primary for 160 to 320 KVA complete all as specified and directed.
Supply only Air clean element secondary for 160 to 320 KVA complete all as specified and directed.
Supply only Oil Filter Assy 160 to 320 KVA complete all as specified and directed.
Supply only Set of rubber ‘O’ ring 160 KVA to 320 KVA complete all as specified and directed.
Supply only Pipe air cleaner to turbocharger 160 KVA to 320 KVA complete all as specified and directed.
Supply only Hose pipe & Flexible pipe for DG set 160 KVA to 250 KVA complete set complete all as specified and directed.
Supply only Fan belt for water pump for DG set 160 KVA to 320 KVA complete all as specified and directed.
Supply only Fan belt for alternator dynamo for DG set 160 KVA to 320 KVA complete all as specified and directed.
Supply and filling in replacement for engine oil 20 W 40 and as type required at site complete all as specified and directed.
Supply and fix in replacement for rotary barrel pumps complete all as specified and directed.
Supply only cotton cloth for cleaning of DG set complete all as specified and directed.
S&Fin replacement for HRC fuse DIN typr breaking capacity 100to 200 Amp with fuse base for DIN type HRC fuse links complete all as specified and directed.
S&Fin replacement for HRC fuse DIN typr breaking capacity 220to 380 Amp with fuse base for DIN type HRC fuse links complete all as specified and directed.
S&Fin replacement for HRC fuse DIN typr breaking cap 400to 600 Amp with fuse base for DIN type HRC fuse links complete all as specified and directed.
S&F for coolant for radiator DAFC 30 % complete all as specified and directed.
S&F in replacement for automatic digital control unit with display of DG set parameters complete all as specified and directed .
S&F in replacement for mono block pump for lifting of diesel to tank of cap 1 HP single phase complete all as specified and directed.
S&F in replacement for FIP assembly for DG set of cap 160 to 320 KVA complete all as specified and directed.
Dismantling and calliberation for fuel pump of DG Set of any capacity including replacement of seal and kit from authorised delears work shop including refixing and testing complete all as specified and directed.
S&F in replacement for water pump assembly complete all as specified and directed.
M&L for in repairs earthing complete with galvanized steel earth plate electrode 600mm x600 mm x 6mm buried directly in ground vertically to a depth not less then 2.25 meter below normal ground level with top edge of the plate not less then 1.50 meter below normal ground level connected to galvanized iron earth strip 32x6mm by means of bolts ,nuts ,check nuts and washers complete up to and including test point made out of 40 x 6mm alum flat including earthing pit , charcoal common salt ,Earthing strip 32x6 mm up to 7.5m, 20mm dia medium grade GI watering pipe ,G.I. protection pipe light grade 40 mm dia up to 7.5m long, complete all as shown in electrical plate No-3 of SSR-2009 (part-I) & testing on completion :- (a) GI earth strip 32x6mm. (b) Watering pipe GI medium grade 20mm dia from top of the earth electrode up to MS funnel with wire mesh embeded in floor of PCC earth pit. (GI Funnel should properly tightned on GI watering pipe and embeded in PCC floor of earth pit with open top suitable for watering of earth pits) (c) Excavation & earthwork in any type of soil PCC earth pit 30x30x30cm constructed in PCC 1:2:4 type B1 exposed surfaces smoothly finished with 15mm thick plaster in cement mortar 1:6 including RCC pit cover 50mm thick 1:2:4 type B1 reinforced with 8mm dia steel TMT bar 75mm centre to centre with 2 Nos MS handles of 12mm dia suitable for carrying of pit cover.
Dismantling and taking down alternator assembly from existing engine and carry out servicing / maintenance of alternator unit of capacity 160/250/320 KVA DG set as per the phase work :- (a) Opening of Alternator and cleaning / remvoing dust from armature and field coil. (b) Cleaning of used / old lubricated substances drive/non drive end bearings. (c) Cleaning end cheeking of AVR unit (d) Cheking and tighting of coupling bolts and replacement of rubber inserts. (e) M&L for carrying out heat varnishing for field and armature coil and kept in heating chamber for 48 hours for drying properly. (f) Replacement of Bearings as per existing size. (g) Reassembling complete unit and carrying out testing at workshop and transportation to installation and coupling with DG Set including necessary alignment, cable connections all as specified and directed by Engr-in-Charge.
Supply only carbon bushes for capacity 160 to 320 KVA complete all as specified and directed.
Supply only petrolium jelly complete all as specified and directed.
Cleaning and scraping of old painted surface of 160/250/320 KVA DG set including removing of oily substances for painting of complete DG Set (such as Engine, alternator, base frame, inlet/out let pipes, fuel tank cylinderical/ square type with stand, LT control panel board, concreate platform) by using first quality automotive paint as per MES colour codes including canopy and letter writting of SM/MES No and out going feeder names on LT panel complete all as specfied and directed.
Supply and fixing sensing / control card for digital control panel for capacity 160 to 320 KVA complete all as specified and directed. .
Supply and fixing in repair governor suitable for 320 KVA Cummins DG set Complete all specified and directed complete all as specified and directed. .
Supply & Fixing in replacement, retro reflective installation board made out of acrylic sheet, size 1.2 x 1.0 Mtr. Writing with computer graphic marking, size of letter not more than 50 mm in length with approved white letter writing on blue back and border of 10mm all around including necessary grouting the installation board with PCC 1:2:4 with 20mm graded stone aggregate upto the depth of not exc. 50mm from ground level and to the ground with angle iron of size 40x40x6mm complete with necessary frame work, welding, bending etc complete all as specified and as directed.
Dismantling and Taking Out old unserviceable LT Panal and Supply, installation, Commissioning and testing LT panel board of size 1500 x 1200 x 300 mm (Approx) for 3 phase, 4 wire, 415 Volts, AC, 50 Hz supply, Indoor cubical type, dust and vermin proof, pedestal mounting type suitable for Indoor applications having suitable shape/ size , made out of 1.6 mm thick MS sheet with using 40mm x 40mm x 5mm angle iron frame and supports, duly finished with powder coated of approved colour over a coat of red oxide primer all over steel surfaces complete with separate compartment of suitable shape and size with shutter and locking arrangement for each switchgear and including PCC work for fixing panel legs 45 cm above ground level and bus bar of aluminium conductor suitable shape and size, including taking out end connectinons of the existing cables and fixing the cable with the panel using new lugs and glands of suitable size including following switchgear & controls complete all as specified and directed.
Charan sales and Service
Mukesh Enterprises
M/S ISLAM AND BROTHERS
Surjit and Sons
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .