| 1 | L1₹39.1 LAccepted-AOC G 86 DATA RAM SECTOR 18 ROHINI NEW DELHI DELHI 110085 | NORTH WEST DELHI | DELHI | 110085 | L1 | Accepted-AOC Being lowest and competitive | |
| 2 | L2₹41.8 L+₹2.3 L (5.85%)Rejected-AOC 137 3 STREET NO 4 RAJINDER NAGAR DEHRADUN UK 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | L2 | Rejected-AOC Neither lowest nor competitive | |
| 3 | L3₹43.3 L+₹3.8 L (9.70%)Rejected-AOC C 9 53 IIND FLOOR SECTOR 08 ROHINI DELHI 110085 | DELHI | NORTH WEST DELHI | DELHI | 110085 | L3 | Rejected-AOC Neither lowest nor competitive | |
| 4 | L4₹44.4 L+₹4.9 L (12.3%)Rejected-AOC PLOT NO 10 9 OM VIHAR PHASE 1 A UTTAM NAGAR NEW DELHI 110059 | WEST DELHI | DELHI | 110059 | L4 | Rejected-AOC Neither lowest nor competitive | |
| 5 | L5₹46.9 L+₹7.4 L (18.7%)Rejected-AOC FLAT NO 330 PKT 1 SECTOR 1 DWARKA NEW DELHI 110 075 | NEW DELHI | NEW DELHI | DELHI | 110075 | L5 | Rejected-AOC Neither lowest nor competitive |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
26 Nov 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (Central) Delhi Cantt
GE (Central) Delhi Cantt
PROVN OF CERTAIN SANCTION WORKS IN THE AREA OF AGE B/R-I AND AGE E/M UNDER GE (CENTRAL) DELHI CANTT-10
2020_MES_390755_1
GE/C-55/2020-21
Open Tender
Civil Works
Item Rate
180 days
GE (Central) Delhi Cantt
As per NIT
9 documents required · 9 mandatory
₹500
GE (Central) Delhi Cantt
₹96,000
Yes
22 Dec 2020
31 Oct 2020
28 Nov 2020
31 Oct 2020
26 Nov 2020
14 Nov 2020
31 Oct 2020 - 14 Nov 2020
60 days
Amount
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tile to store and rubbish off the premises complete all as specified and directed by Engineer-in-Charge.
M& L for non skid coloured ceramic tiles (300x300x)7 to 8mm thick in floors, etc, set and jointed in neat cement slurry and pointed in coloured cement to match laid over and including 15mm thick screed bed for laying floor in CM 1:6 complete all as specified and directed by Engineer-in-Charge.
M&L for coloured ceramic tiles (600x300mm)x7mm thick on vertical surfaces on skirting dados and risers to steps etc including 10mm thick cement mortar redering CM 1:4 complete all as specified and directed by Engineer-in-Charge.
S&F Chromium plated shower roses with or without swivel joints, 110 mm any size, including fixing to steel pipe or union complete all as specified and directed by Engineer-in-Charge.
S&f in Toilet paper holder of vitreous china fixed to wall with chromium plated brass screws complete all as specified and directed by Engineer-in-Charge.
S & F in Brass CP wall mixer for mixing hot & Cold water screwed down for iron pipe 15 mm bore and fixed complete all as specified and directed by Engineer-in-Charge.
S & F in Brass CP wash hand basin mixer for mixing hot & Cold water screwed down for iron pipe 15 mm bore and fixed complete all as specified and directed by Engineer-in-Charge.
S&F in Towel rail 600mm long of PTMT fixed with and including Chromium plated brass screws and wooden/Plastic cleats.(Minimum weight 190gms) complete all as specified and directed by Engineer-in-Charge.
S&F in vitreous china wash down water closet pan (pedestal pattern white including fixing bolt flushing cistern and flush pipe and including plastic water closet seat black closed pattern with flat bottom and cover and mild steel chromium plated or aluminium hinging device complete all as specified and directed by Engineer-in-Charge.
S & F in vitreous china wash hand basin white flat back size 630x450mm excluding taps but including waste chain and plug and porcelam sotpper but including brackets complete all as specified and directed by Engineer-in-Charge.
S & F in repair CP bib taps fancy type cast copper alloy with crutch or butterfly handle screwed down screwed for 15 mm bore pipe or for brass ferrule complete all as specified and directed by Engineer-in-Charge.
S & F in 15mm bore angle valve fancy type chromium plated cast copper alloy high pressure with crutch or butterfly handle screwed ends for iron pipe or for union and fixed complete all as specified and directed by Engineer-in-Charge.
S & F in repairs two way angle valve chromium plated with long shank and cup suitable for 15mm bore pipe complete all as specified and directed by Engineer-in-Charge.
S & F grating round 140mm size of PTMT(minimum wt 50 gms) complete all as specified and directed by Engineer-in-Charge.
S & F PVC connections 15mm size with PTMT nuts of length 450mm complete all as specified and directed by Engineer-in-Charge.
Takingup or down steel tubing and connections including cleaning for i.e refixing or removal to store 15 mm bore tubes complete all as specified and directed by Engineer-in-Charge.
S&F steel tubes medium grade 15mm bore galvanised with all fittings and fixed complete to walls and ceilings or laid in floor if in short length, including cutting chasing pinning and making good to pointing complete all as specified and directed by Engineer-in-Charge.
S&F in repairs Glass shelf assembly 450mm long 150mm wide complete all as specified and directed by Engineer-in-Charge.
S &F Health foucet, CP brass with 1.50mm long flexible pipe including two way angle cock suitable for 15mm bore pipe complete all as specified and directed by Engineer-in-Charge.
S&F Glass Corner Shelf 8mm thick including CP railing radius 300mm complete all as specified and directed by the Engineer-in-Charge.
M & L for Granite 16-18mm thick machine cut, bedded and jointed with grey cement over and including 15mm thick screed bed in CM 1:6 complete all as specified and directed by Engineer-in-Charge.
M&L for Prelalminated particle board 18/19mm thick, exterior grade prelaminated both sides with decorative choice laminations in Kitchen cuboards and shutters of Kitchen cupboards / almirahs complete all as specified and directed by Engineer-in-Charge.
S&F in repairs continous (piano hinges, mild steel bright finish or electro galvanized width of flap 30mm when open complete all as specified and directed by Engineer-in-Charge.
S&F in repairs 40mm dia cup board knob fixed with nut screw and washer of mild steel bright finish complete all as specified and directed by Engineer-in-Charge.
M&L for roof treatment as per the description below:- a) Plain cement concrete average 50 mm thick 1:2:4 type B0 (using 12.5 mm graded stone aggrigate )for levelling course for providing slope in the roof @ 1:40 gradient. b) Apply bituminous primer @ 0.3 ltr/Sqm (conforming to IS-3384) on prepared surfaces. After drying of primer apply a coat of hot blown 85/25 grade bitumen conforming to (IS-702 @ 1.20 kg/Sqm of prepared surfaces. c) Laying APP (Atatic Polypropylene) modified five layered membrane 3 mm thick and weighing not less than 4 Kg/Sqm with centre core 160 GSM/ Sqm ; core reinforced and laid with 75 mm side overlap and 150 mm end lap. The membrane shall be laid with LPG torch application and overlaps sealed and finished neatly as per the manufacturer specification And apply two coat of silver aluminum paint complete all as specified and directed by Engineer-in-Charge..
Cuttting chases for concealed water tubing or concealed conduct wiring etc and making good cutting exc 10 cm not exc 20 cm grith in brick wall complete all as specified and directed by Engineer-in-Charge..
S&F powder coated aluminum frames for windows/ventilators with one or more rebates including jointing cleats for fixing etccomplete all as specified and directed by Engineer-in-Charge..(Make : Jindal/Hindalco/Indal)
S&F powder aluminum glazed/gauzed windows and ventilators shutters Top hung type without sash bar aluminum section weighing 0.55 kg per mtr including necessary jointing cleats glazing clips rubber packing anodised aluminum beading screws including fittings such as i no peg stays 150 mm long, 2 nos aluminim hinges 75 mm long ,2 no tower bolt 100 mm long and 1 no aluminim handle 100 mm long etc in each shutter complete all as specified and directed by Engineer-in-Charge.. Make Zindal / Hindalco / Indal)
S & F in repair Rotational moulded polyethylene water storage tanks of 1000 Litres capacity, (cylindrical vertical tanks with closed top) hoisted and fixed in position including making necessary arrangements for fixing inlet, outlet and over flow pipe and provision of wash out pipe etc .Including dismantling of existing water tank complete all as specified and directed by Engineer-in-Charge.
S&F 4 mm thick pin headed glass panes used in anodised aluminum glazed/gauzed windows and ventilators shutters complete all as specified and directed by Engineer-in-Charge.
Taking down old MCCB , TPN DBs , & main switch/ enclosure box of any make and type from the site and making good surface complete all as specified and directed by Engineer-in-Charge.
Taking down old submain wiring of any size and make from the site and making good surface complete all as specified and directed by Engineer-in-Charge.
M&L for submain wiring with two single core PVC insulated FRLS 1100 Volts unseathed stranded copper conductor cable 6 Sqmm concealed in and including new PVC conduit medium grade not less than 20 mm dia, for submain wiring and connection complete FRLS 1100 volts unsheathed stranded copper conuctor cable of 6 Sqmm size stranded conductor as earthwire complete all as specified and directed by Engineer-in-Charge..
M & L Sub main wiring complete with two runs of 6 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable with one run of 6 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through existing metallic/ non metallic conduit in walls complete all as specified and directed by Engineer-in-Charge.
M&L for submain wiring with two single core PVC insulated FRLS 1100 Volts unseathed stranded copper conductor cable 10 Sqmm concealed/surface in and including new PVC conduit medium grade not less than 20 mm dia, for submain wiring and connection complete FRLS 1100 volts unsheathed stranded copper conuctor cable of 10 Sqmm size stranded conductor as earthwire complete all as specified and directed by Engineer-in-Charge..
Supply & fix factory made epoxy powder coated Distribution Board TPN-4 ways with metal door (IP-43 protection) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amp copper bus bar, neutral bar, standard DIN rail, Earth bar and cable ties for cable management, top and bottom removeable gland plates with knockouts and suitable for one TPN- MCCB 125/160 Amp as incomer and 40 to 63 Amp SP MCBs outgoing complete all as specified and conforming to IS : 8623 complete all as specified and directed by Engineer-in-Charge..
M&L MCCB 125 Amps, 16 KA , 4P, 415 Volts, 50Hz , with thermal magnetic setting complete all as specified and directed by Engineer-in-Charge..
Supply and fix MCB DB SPN 8 way Horizontal, IP - 43 Protection double door 240 V AC 50Hz with for MCB SPN as incomer and SP MCBs as out going with tinned copper bus bar ,neutral link earth link complete complete all as specified and directed by Engineer-in-Charge.
M&L for earthing of machinery/equipment/panel/installed at power house/subatation, complete with galvanised steel earth palte electrode 600 x 600 x 6 mm thick buried directly in ground (Earth pit not less than 2.5 mtrs deep below ground level) with top edge of the plate not less than 1.5 mtrs below normal ground level connecting to galvanised iron strip 25 x 4 mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel and earth protected by 40 mm dia GI pipe medium grade and connected to distribution board/earthing test point all as shown in electrical plate No.3 of SSR Part-I )2009) and testing on complete all as specified and directed by Engineer-in-Charge.
M&L earth continuity conductor or main earthing lead fixed to wall on batten or recessed or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc of size 25x4 mm thick galvanised strip duly fixed on suitable size of porcelain/ PVC insulator complete all as specified and directed by Engineer-in-Charge.
S&F in replacement branded steel sheet MCCB enclosure box along with 160 A, 4 pole 16 ka MCCB, completely connected with copper thimble and with all accessories complete all as specified and directed by Engineer-in-Charge.
Taking down carefully unserviceable LT panel including disconnecting of incoming and outgoing connections complete all as specified and directed by Engineer-in-Charge.
S&F in repair bus bar strips of existing sizes making holes for connecting cable lugs and insulators including nuts and bolts and providing epoxy joints for housing bus bar strips including welding joints, providing hinges, provision of locking arrangement complete all as specified and directed by Engineer-in-Charge.
S&F MCB DB SPN 12 way Horizontal, IP - 43 Protection double door 240 V AC 50Hz with for MCB SPN as incomer and DP/SP MCBs as outgoing with tinned copper bus bar ,neutral link earth link complete all as specified and directed by Engineer-in-Charge.
S&F in repair MCB SPN 63 Amps 240 volts 10 KA 50 HZ 'C' curve complete all as specified and directed. Make :- Legrand cat part No 408620 or equivalent make of Havells / Indo Asian
S&F in repair MCB SPN 40 Amps 240 volts 10 KA 50 HZ 'C' curve complete all as specified and directed by Engineer-in-Charge.
S&F in repair MCB SPN 32 Amps 240 volts 10 KA 50 HZ 'C' curve complete all as specified and directed by Engineer-in-Charge.
M&L in replacement MCB SP 6-32 Amps 240 volts, ‘C’ curve, 10KA breaking capacity complete all as specified and directed by Engineer-in-Charge.
M&L in replacement sheet metal enclosure, single pole and neutral with a two pin and earth plug and socket 240 Volts grade 20Amps with one single pole MCB 'C' series 20 Amp capacity complete all as specified and directed by Engineer-in-Charge.
S&F MCCB 100 Amps, FP 415 volts 16 KA 50 HZ with thermal magnetic setting complete all as specified and directed. Make :- Legrand / Havells / Indo Asian
S&F MCCB 160 Amps, FP 415 volts 16 KA 50 HZ with thermal magnetic setting complete all as specified and directed. Make :- Legrand /Havells / Indo Asian
S&F in repair Sub main wiring with two runs of 4 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable with one run of 4 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through including 25 mm dia non metallic rigid PVC conduit and conduit accessories on surface of walls complete all as specified and directed by Engineer-in-Charge.
S&F in repair Sub main wiring with two runs of 10 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable with one run of 10 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through existing conduit and conduit accessories (Concealed) in walls complete all as specified and directed by Engineer-in-Charge.
S&F blank plate of suitable size for open space in distribution boards complete all as specified and directed by Engineer-in-Charge.
M&L providing protection pipe PVC or flexible pipe as reqd at site to out going cables, cleaning of LT panel boards with air blower cleaning inside, dressing in proper alignment, replacement of rusted iron parts with new one with suitable size of angles/strips, painting of new parts with matching colour as per existing, tightening of fixing bolts and nuts, providing thimbles to whole bunch of wires uniformly clean manner etc complete all as specified and directed by Engineer-in-Charge.
S&F switch fuse unit TPN 440V 50Hz AC 200A with HRC fuse including connecting, testing with suitable size aluminium lugs as per site requirement complete all as specified and directed by Engineer-in-Charge.. Make :- Havells / Indoasain /Legrand
M & L in replacement for only twin core PVC insulated unarmoured cable 6 Sqmm Flat 1100 Volts with Aluminium multi stranded conductor complete all as specified and directed by Engr-in-Charge. Make:- " RR KABLE/POLYCAB/ HAVELLS".
S&F switch fuse unit TPN 440V 50Hz AC 100A with HRC fuse including connecting, testing with suitable size aluminium lugs as per site requirement complete all as specified and directed. Make :- Havells / Indoasain /Legrand
Supply and fix MCCB 63 Amps, FP 415 volts 16 KA 50 HZ with thermal magnetic setting complete all as specified and directed by Engineer-in-Charge..
M&L for Sub main wiring complete with FRLS PVC insulated unsheathed stranded copper conductor wire 4 Sq mm 02 Nos. (for Phase & Neutral) along with earth wire FRLS PVC insulated unsheathed stranded copper conductor wire of size 4 sq mm wire drawn through existing PVC conduit 20 mm dia medium grade ISI marked including all fitting accessories fixed on wall/roofs/ceilings etc complete all as specified and directed by engr-in-charge.
M&L in replacement for only twin core PVC insulated unarmoured cable 10 sq mm flat 1100 volts with Aluminium multi stranded conductor and drawing in existing concealed conduits, hanging or suspended over GI wire 4 mm dia and binding with real insulator not more than 1 mtr space complete all as specified and directed by engr-in-charge.
M&L for earthing complete with galvanised steel earth plate electrode 600x600x6.3 mm thick burried directly in ground (earth pit not less than 2.25 mtrs deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level connected to galvanized iron steel wire of 4mm dia by means of bolts nuts check-nuts and washers of galvanized iron or steel as shown in electrical plate No 5 of MES schedule Part-I connecting to earthing test point and testing on completion with including 15mm bore light grade GI protection pipe, RCC 1:2:4 type B1 20mm thick cover reinforced with 6mm thick dia MS bars 3 Nos both ways with lifting hook made out of 6mm dia MS bar, watering arrangement with funnel and wire mesh and 20mm bore light grade GI watering pipe, earthing lead from earth plate to eqipment to point (up to 7.5M long) common salt and charcoal filling, necessary excavation and earth work complete all as specified and directed by engr-in-charge.
Taking down carefully copper/aluminium point wiring (light/fan/ socket/power) complete from the wall by cutting/ chasing including fittings and fixtures such as switches, ceiling roses, pendants holder, regulators,sockets,light fittings etc for credit and making good the disturbed surfaces of wall, floor etc complete all as specified and directed by engr-in-charge.
M & L for Point wiring with PVC unsheathed multi stranded copper conductor cable 1.5 sqmm (nominal dia ) 1100 volts in new PVC concealed conduit and new MS steel terminal boxes not less than 1.6 mm thick of required size (factory made) terminal boxes and with top cover of 3 mm thick hylam sheet of white colour including one run of 1.5 SQMM FRLS 1100 Volts copper conductor cable (green colour) as earth continuity connected to common earth for one light point complete all as specified and directed by Engr-in-Charge for the followings:- Note :- (i) In case the wiring is encountered with any beam/column, then the wiring will run on PVC conduit to avoid any damage to the RCC portion. (ii) No cutting shall be done in the roof for laying PVC conduit for ceiling fan point wiring, in this specified portion wires shall run through the surface new conduit shall be provided as mentioned in note (i) above. (iii) Proper colour code will be used for wiring as per the electrical rule and as directed by EIC.
One light /Ceiling fan/exhaust fan/ bell point controlled by one switch.
One 3 pin 5 Amps socket outlet point controlled by one No one way switch on same board
One 3 pin 5 Amps socket outlet point controlled by one No one way switch on Ind board
All as per item No.75 herein before but with 4 sqmm cable for one 3 pin 15 Amp switch socket outlet and using 4 sqmm PVC single core copper conductor cable multistranded as earth wire complete.
S & F switch piano, flush type, single pole, 5 Amps 230Volts ISI Marked complete all as specified and directed by Engineer-in-Charge.
M&L socket outlet 5 Amps 5 pin flush type complete all as specified and directed by Engineer-in-Charge ISI marked
M& L Socket outlet 2 in 1, 3 pin, 5 and 15 amp flush type complete all as specified and directed by Engineer-in-Charge.
S & F switch piano, flush type, single pole, one way 15 Amps 230 Volts complete all as specified and directed by Engineer-in-Charge. .
Supply & Fix fan regulator electronic step type 5 steps piano type, one module connecting complete all as specified and as directed by engr-in-charge.
S&F ceiling rose PVC /Poly carbonate,surface type with three terminals complete all as specified and directed by Engineer-in-Charge..
Supply and fix LED batten luminaire surface mounted, 4 feet system wattage of 20-22 Watts with lifetime of 50000 burning hours with 70% of its initial lumen maintained. CRI>80, Power Factor > 0.95, THD< 20%, colour temperature - 6500K, surge protection 3KV in CM, IP-20 protected, meets LED IS specifications, Class - 1, Short circuit and over circuit protection, voltage range - 150 to 270 Volts AC, temperature range 0 to 50 Degree C, system efficency at luminaire level > 105 Lumens/watt and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire from ceiling rose to fitting fixed complete all as specified and directed by Engr-in-charge. Note- All the above mentioned specs will be verified through LM 79 and LM 80 report of NABL accredited lab before supply of LED fixtures complete all as specified and directed by Engineer-in-Charge..
Supply and fix LED 2 X 2 ft backlite surface mounted fitting 36/40 Watts not less than 3200lm with Metallic CRCA powder coated body with high efficiency opal/PMMA diffuser with system efficacy > 80 lm/W, CRI>80, color temperature >5700k, IP 20, Power factor<0.95, THD<10%, 50000 burning hours , Ambient temperature 0 to 500 DegC, Driver should meet IEC complaint for safety, with voltage variation range of 150-270 V and surge protection of 2.5 KV including necessary fixing arrangementsfixed complete all as specified and directed by engr-in-charge.
S&F in replacement of LED 10 watts bulkhead fitting with powder coated die cast aluminium housing with glass/ non yellowing polycarbonate cover, IP65 Protection, System level efficacy of the Luminary is > 100 lm/W with a life class of 50,000 burning hours at L70 criteria, Power Factor >0.95, driver with Voltage range 150-270V, Temperature range 0 to 50 Deg, Driver efficiency >85%, THD<20%, CRI>80, Color Temperature-6500K, Surge protection of 4 KV, including connecting up with necessary PVC sheathed 3 core 1.5Sqmm copper conductor flexible wire fixed complete all as specified and directed complete all as specified and directed by Engr-in-charge. Note :- All the above mentioned specs will be verified through LM 79 and LM 80 report of NABL accredited lab before supply of LED fixtures.
Supply and fix surface ceiling mounted, round LED down light fitting 15 watts with die cast aluminium housing and system wattage of 15W, system efficacy at luminary level ≥ 100 Lumens/watt, 50000 burning hours, 6500K color temperature with CRI >80, Power Factor > 0.90, Driver should meet IEC compliant for safety with multi stage high Isolate CC-CV operated driver with voltage variation range - 150 to 270 Volts AC, and surge protection of 3 KV, and including connecting up with PVC sheathed 3 core 1.5Sqmm copper conductor flexible wire fixed complete all as specified and as directed by engr-in-charge. Note- All the above mentioned specs will be verified through LM 79 and LM 80 report of NABL accredited lab before supply of LED fixtures.
S&F 35 W High efficient LED Street light fitting with pressure die cast Aluminum housing and has lenses specially designed for Street Lighting with polycarbonate cover. System level efficacy of the Luminarie should more than 80lm/W. The color temperature is around 6500 K with a color rendering index of 70. The luminaire is IP:66 protected. It has an electronic driver complaint to IEC safety standards with a power factor>.0.9, voltage variation range 120-270V, THD<20%, High and low protection along with a surge protection of 4 KV complete as specified and directed by engr-in-charge.
S&F GI Pipe bracket bent to shape drilled welded made out of light grade GI pipe 25mm dia 1.5 mtr long and fixing on the wall where as directed by the Engr-in-Charge for fixing of building security light fitting including clamps, nuts, bolts and washers complete all as specified and directed by engr-in-charge.
S &F heavy duty exhuast Fan 450 mm sweep, 1400 RPM, metallic body, single phase 240 volts AC 50 Hz and connecting up complete including louvers and provision of copper cable 3 core of size 1.5 sqmm complete all as specified and directed by engr-in-charge
Cutting the existing wall/removing existing steel bar to make a hole for fixing of exhaust fan through packing of wooden ply to support the ventilating/ air circulating fan including necessary nut and bolts of suitable size incl make good of disturbed surface complete all as directed by Engr-in charge.
S &F Ventilating Fan 250 mm sweep, 1250 RPM, non metallic resin body, single phase 240 volts AC 50 Hz and connecting up complete including louvers and provision of copper cable 3 core of size 0.5 sqmm complete all as specified and directed by engr-in-charge
S &F Exhaust fan (Metal body) 300mm sweep with louvers including connecting with suitable size of copper conductor from ceiling rose to fan complete and making holes for fitting etc complete all as specified and directed by Engineer-in-Charge.
Supply and fix LED batten luminaire surface mounted 2 feet system wattage of 10 watts and not less than 1000 lm with life time of 50000 burning hours with 70% of its initial lumen maintained. CRI > 80, power factor > 0.95, THD < 10%, color temperature > 6500 K , surge protection 2.5 KV in CM IP- 20 protected meets LED IS specifications, voltage range - 150 to 270 volts AC, temperature range 0 to 50 Degree C, system efficiancy at luminarie level ≥100 Lumens/watt and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire fixed complete all as specified and directed.
One power point with pre insulated unsheathed standerd copper conductor cable & 2.5 sqmm single core (FRLS) and pre unsheathed copper conductor 2.5 sqmm single core on earth wire connected to earth doly complete all as specified and directed by Engineer-in-Charge.
M&L angle Lamp holder with metallic ring, PVC/Polycorbonate type with back plate complete all as specified and directed by Engineer-in-Charge.
S & F LED bulb 9 watts, 900 lumens output, 6500K suitable for B-22 base complete all as specified and directed by Engineer-in-Charge.
S&F ceiling fan three blade, robust and reliable inverter motor (brush less DC Motor) powdered by ECM technology, BEE 5 star rating for energy saving ISI mark, rated Air delivery>220cum/min, service value>6 AC single phase 230/240 V of size 1200 mm sweep including making connection with three core flexible coper cable pvc insulated of suitable length as specified and directed by Engr in Charge.
Note :- Total amount of Sch of credit is Rs. 44095.00 as per Sch of credit. Net contract sum shall be total quoted amount of bidder (-) amount of Sch of credit.
M/S ANIL KUMAR
L G BUILDERS
LAMBA ENTERPRISES
The new hut furnitures
imran construction company
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .