Staff Officer (EnM),M-S Area
Office of the General Manager M-S Area, Bachra. 829201.
Repairing Rewiring and changing of service wire of qtr. Number C-24 KDH Colony Dakra under Magadh Sanghmitra Area
2023_CCL_281805_1
GM(M-S)/SO(EnM)/e-NIT/23-24/44
Open Tender
Electrical and Maintenance Works
Item Rate
5 days
Office of the general manager M-S Area, Bachra
Please Refer NIT
4 documents required · 4 mandatory
₹1,950
9 Jan 2024
19 Jun 2023
29 Jun 2023
19 Jun 2023
28 Jun 2023
19 Jun 2023
19 Jun 2023 - 26 Jun 2023
Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required Group A
Wring for circuit/ subman wiring alongwith earth wire with 2x2.5 sqmm + 1x2.5 sqmm. FR PVC insulated copper conductor single core cable in surface/recessed steel conduit as required
Supplying and fixing of metal box of 180mmX100mmX60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 15/16 amps socket outlet and 15/16 amps piano type switch connection , painting etc. as required.
Wiring for light/power plug with 2x4sqmm FR PVC insulated copper conductor single core cable in surface/ recessed steel conduit along with 1No. 4 sqmmFR PVC insulated copper conductor single core for loop earthing as required.
(1)Supplying and fixing of 5amps to 32amps rating, 240/415volts "c" curve, miniature breaker suitable for induction load of following poles in the existing MCB DB complete with connections testing and commissioning etc.as required. (1) single pole.
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supply of 2+2 way, SPN single door, MCB distribution box.
Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required.200 mm X 150 mm X 60 mm
Supplying and fixing two modular stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and drawing of 2x6sq.mm of FR PVC insulated copper conductor single core in the existing surface recessed steel/PVC conduit as required.
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Total impact of GST for the purpose of CTC
M/S M. S. Construction
KHALSA ENTERPRISES
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_291784.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .