| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.7 LAccepted-AOC | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹9.6 L+₹72,984.38 (8.21%)Rejected-Finance 26M NEEM SARAI DHOOMANGANJ PRAYAGRAJ 211011 | PRAYAGRAJ | UTTAR PRADESH | 211011 | L2 | Rejected-Finance BEING NOT LOWEST | |
| 3 | L3₹10.2 L+₹1.3 L (14.9%)Rejected-Finance | L3 | Rejected-Finance BEING NOT LOWEST | |
| 4 | L4₹10.2 L+₹1.4 L (15.3%)Rejected-Finance 145 SAINIK NAGAR RAIBARELLI ROAD TELIBAGH LUCKNOW | L4 | Rejected-Finance BEING NOT LOWEST | |
| 5 | L5₹10.4 L+₹1.5 L (16.6%)Rejected-Finance 5 31 EWS PREETAM NAGAR ALLAHABAD 211011 | ALLAHABAD | ALLAHABAD | UTTAR PRADESH | 211011 | L5 | Rejected-Finance BEING NOT LOWEST |
Tender Value
₹9.5 L
EMD Value
₹19,000
Closing Date
1 Oct 2024, 6:00 pmClosed
Sh Vikash Singh, AE (E/M), AGE(I) AF Manauri
AGE (I) AF MANAURI PRAYAGRAJ
REPAIR / REPLACEMENT OF DISTRIBUTION BOX AND EARTHING SYSTEM IN MD ACCN AREA UNDER AGE (I) AF MANAURI
2024_MES_671076_1
9190/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Manauri Prayagraj
As per tender doc
7 documents required · 7 mandatory
₹500
AGE (I) AF MANAURI
₹19,000
Yes
31 Dec 2024
3 Sept 2024
3 Oct 2024
3 Sept 2024
1 Oct 2024
18 Sept 2024
Amount
S&F in replacement factory made sheet metal enclosure distribution boards, (protection class IP-43) double door, verticle type suitable for mounting MCCBs/ RCCBs/ MCBs conforming to IS : 13032, IS : 8623, BS : 5484 with 200 Amps rating bus bar, triple pole and neutral, 4 ways, TPN 415 volts. Note :- MCCBs/ RCCBs/ MCBs shall be measured and paid for separately under respective item of this schedule.
S&F in replacement factory made sheet metal enclosure distribution boards, (protection class IP-43) double door, verticle type suitable for mounting MCCBs/ RCCBs/ MCBs conforming to IS : 13032, IS : 8623, BS : 5484 with 200 Amps rating bus bar, Single pole and neutral, 12 ways, 240 volts. Note :- MCCBs/ RCCBs/ MCBs shall be measured and paid for separately under respective item of this schedule.
S&F in replacement factory made sheet metal enclosure distribution boards, (protection class IP-43) double door, verticle type suitable for mounting MCCBs/ RCCBs/ MCBs conforming to IS : 13032, IS : 8623, BS : 5484 with 200 Amps rating bus bar, Single pole and neutral, 8 ways, 240 volts. Note :- MCCBs/ RCCBs/ MCBs shall be measured and paid for separately under respective item of this schedule.
S&F in replacement factory made sheet metal enclosure distribution boards, (protection class IP-43) double door, verticle type suitable for mounting MCCBs/ RCCBs/ MCBs conforming to IS : 13032, IS : 8623, BS : 5484 with 200 Amps rating bus bar, Single pole and neutral, 4 ways, 240 volts. Note :- MCCBs/ RCCBs/ MCBs shall be measured and paid for separately under respective item of this schedule.
S&F in replacement MCCB, four pole, 415 Volt ,63 Amp rating, 16 KA ultimate breaking capacity fixed in DBs catered herein before. Make ; Seimens / Legrand / C&S/ L&T/ Havells
S&F in replacement MCCB, four pole, 415 Volt ,125 Amp rating, 25 KA ultimate breaking capacity fixed in DBs catered herein before. Make ; Seimens / Legrand / C&S/ L&T/ Havells
S&F in replacement MCCB, four pole, 415 Volt ,250 Amp rating, 36 KA ultimate breaking capacity fixed in DBs catered herein before. Make ; Seimens / Legrand / C&S/ L&T/ Havells
S&F in replacement MCB, tripple pole and neutral, 415 volts, 40 Amps rating, 10KA, "C" series fixed in DBs catered herein before.
S&F in replacement MCB, single pole and neutral, 240 volts, 32 Amps rating, 10KA, "C" series fixed in DBs catered herein before.
S&F in replacement MCB, single pole, 240 volts, 32 Amps rating, 10KA, "C" series fixed in DBs catered herein before.
S&F in replacement MCB, single pole, 240 volts, 6 to 10 Amps rating, 10KA, "C" series fixed in DBs catered
S&F PVC insulated muilticore strandard copper single & multi flexible round cable size 1.0 Sqmm 3 core ISI marked 660/1100 Volt conforming to IS:694-1990 complete.
S&F PVC insulated muilticore strandard copper single & multi flexible round cable size 2.5 Sqmm 3 core ISI marked 660/1100 Volt conforming to IS:694-1990 complete.
S&F PVC insulated muilticore strandard copper single & multi flexible round cable size 4.0 Sqmm 3 core ISI marked 660/1100 Volt conforming to IS:694-1990 complete.
S&F PVC insulated sheathed aluminium conductor armoured cable with inner sheathing for service connection size 10 Sqmm 2 core 1100 Volt complete.
S&F PVC insulated sheathed aluminium conductor armoured cable with inner sheathing for service connection size 6 Sqmm 2 core 1100 Volt complete.
Earthing complete with galvanised mild steel earth electrode plate 600 X 600 X 6 mm thick buried directly and vertically in ground connected to galvanised iron earth strip 32x6 MM size by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical Plate No 3 of MES SSR Part-I connected to main switch board or main control board all as specified and testing on completion including provision of earth strip protected by galvanised iron 40 mm bore medium grade pipe with all fittings from the earth electrode fixed along pole with and including 25 x 6mm flat iron clamp, bolts, nuts and washers and watering pipe shall be 20 mm bore GI medium grade from top of the earth electrode to bottom of the earth pit including all excavation and earth work in any type of soil and removal of surplus soil upto 50 metre, PCC pit with pre-cast RCC cover with handle, charcoal/salt, funnel , CI frame etc complete all as directed. Notes :-(i) The concrete pit shall be made in PCC 1:3:6 type C-1, 40mm thick precast cover slab of RCC (1:2:4) type B-1 using 20mm graded stone aggregate with suitable MS handle in lieu of cast iron cover shown in electrical plate No 3 of MES SSR Part-I. Reinforcement in RCC cover shall be of 8mm dia TMT bars laid @150mm c/c both ways.(ii) Item includes the cost of 7.5 metre GI pipe for protection of earth strip. Any variation in length shall be adjusted through deviation order. (iii) Item includes cost of 7.5 metre earth strips. Any variation in length shall be adjusted through deviation order. (iv) Plate electrode shall be surrounded by adequate quantity of charcoal dust & salt to a packed thickness of 15 cm on all sides.
Earth continuity conductor or main earthing lead 32x6 mm GI strip laid in pipe or fixed on wall or any other position including jointing by tinned copper/brass nuts, bolts and washers in adition brazing at every joint .
Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried inground or drawn in conduit/pipe or fixed to poles or any other indicatedsituation for loop earthing etc. as required 8 mm dia galvanised iron or steel wire complete .
Earthing complete with galvanised steel pipe electrode, 40mm bore,medium grade, 2.5 metres length,buried directly and preferablyvertically in ground with top edgenot less than 1.25 metres below ground level connected with earthing lead of 4mm dia galvanised iron or steel wire all as shown in Plate No. 2 to the earthing test point all as specified and indicated including testing on completion
S&F Bldg security light fittings 45 watts energy saving incl making all electric connection using three core copper cable drawn through in PVC flexible counduit pipe from ceiling rose to fittings and mounting bracket made out by GI pipe light grade in 25 mm dia of bore in required length bend in 120 degree fixed with clamping of surface of wall using clamp made out by GI strip in size 32 x4 mm using nut bolt and washer etc complete as directed. Make : Bajaj / Philips/ Crompton/Havells
M&L for sub main wiring with two runs of single core PVC FRLS IS-694 cable with unsheathed multi-stranded copper conductor of size 06 Sqmm and drawing through in concelead rigid non metallic PVC conduit pipe medium grade heavy duty in suitable size with all necessary fittings including one run of FRLS insulated unsheathed stranded copper conductor cable of size 06 Sqmm as earth wire (green in colour) and connected to common earth dolly complete including taking down of old unserviceable sub main wiring including taking out to old unsv sub main wiring with accessories complete all as specified and as directed. Note : (i) Two run of 06 sqmm with one run of PVC conduit pipe shall be measured agaist one unit. (ii) Cost of cutting /chasing/ plastering /colouring etc as site shall be included matching to disturbed surface all as existed.
Excavation in trenches not exc 1.5 M wide and not exc 1.5 M in depth for pipe line, etc getting out in soft/ loose soil and levelling of bottom surface to required level complete and as directed.
Returning filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 CM complete and as directed.
Removing excavated material (soil) out side MD land at contractor's own arrangement complete and as directed.
Supply, laying and spreading of dry (Ganga) sand, free from organic impurities for cushioning as in trenches 8cm depth below cable and 15cm above cable and punned to 10cm depth complete all as specified & directed. Note :- Punned thickness shall be considered for measurement purpose.
M&L brick, sub class 'B' bricks laid dry, flat, length equal to width of brick over sand cusioning in trenches for cable protection complete all as specified and directed
Labour only for cutting/boring to plinth protection/hard standing/road etc in suitable depth and corssing of GI pipe of size 80 MM bore so that XLPE under ground cable can be passed and giving mechanical protection to cable complete all as specified and directed. Note:- Quoted rate shall be included the cost of required material for repairing to disturbed surface all as per existing specification and GI pipe shall be measured and paid seperately under respective itmes.
Supply, laid in trench /fixed in replacement with surface of wall/roof etc jointing, thimbling and glanding in suitable size testing to cable XLPE insulated, screened, PVC bedded galvanised steel strip or wire armoured electric LT cable with alumunium conductor 1100 volts, grade cross section area 4 core x 25 Sqmm (earthed) complete all as specified and directed. Make- Havells/ Finolex/ RPG/ Polycab/ Paragon/ Fort Gloster
All as per item No 29.00 above but size of cable 3.5 core x 50 Sqmm (earthed)
S&F in replacement 40 MM dia GI tubing 'light grade' with fixing acessories laid in trenches or on wall or pole with clamp complete all as specified & directed. Make: Tata/ Jindal/ Swastic
Note :- (i) Credit shown in credit schedule of tender document shall be considered by the tenderer while quoting the rates of various items. The same shall be recovered from various payment to contractor before handing over old material. The contract amount shall be arrived at after deduction of Schedule of Credit from the total quoted amount in BOQ. (ii) Make of material shall be as per mentioned in Particular specifications or Appendix 'B' to Particular specifications as approved by AGE (I) AF manauri if not specified in BOQ
bharat construction (BID ID -3109815)
M/S SATISH KUMAR (BID ID -3109831)
M/S KAUSHIK CONSTRUCTION (BID ID -3124362)
M/S vibhuti enterprises (BID ID -3109617)
FRIENDS N FRIENDS (BID ID -3108572)
gangotri enteriprises (BID ID -3109691)
M/S A M ENTERPRISES (BID ID -3105439)
YOU SEE CONSTRUCTION (BID ID -3105476)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .