Loading…
New: tenders and results on WhatsApp
New: Find tenders, results and companies on WhatsApp, by text or voice note
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.9 LAccepted-Finance 19 62 1ST FLOOR WEST MOTI BAGH SARAI ROHILLA NEW DELHI 110035 | NEW DELHI | NEW DELHI | DELHI | 110035 | L1 | Accepted-Finance Lowest bidder | |
| 2 | L2₹4.0 L+₹10,400 (2.68%)Rejected-Finance WZ 831 NANGAL RAYA PANKHA ROAD NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹4.0 L+₹10,900 (2.81%)Rejected-Finance RZ 14D 2ND FLOOR GALI NO 5 SYNDICATE ENCLAVE NEAR DABRI MORE NEW DELHI 110045 | SOUTH WEST | DELHI | 110045 | L3 | Rejected-Finance Other than lowest bidder | |
| 4 | L4₹4.0 L+₹12,099 (3.12%)Rejected-Finance RZF 498 MG MARG RAJ NAGAR II PALAM DELHI CANTT 110077 | NEW DELHI | DELHI | 110077 | L4 | Rejected-Finance Other than lowest bidder |
| Sl No | Description | Qty | Unit | DUBEY ENTERPRISES L3 | Tushar engineers L2 | SNOWY ENGINEERING INC L1 | MRITUNJYA ASSOCIATES L4 |
|---|---|---|---|---|---|---|---|
| 1.00 | Comprehensive maintenance of Fire alarm and Gas based fire suppression system
comprising 2X60 Kgs seamless cylinder with valves and all connected electromag
netic actuators and kit complete including MS seamless pipes as ASTMA 106-250
etc in Old Server Room Automatic battery charger, 24 volts sealed lead acid batter
ies sufficient for 24 hours normal working and then be capable of operating the
system for 2 hours during an emergency conditions as required. (1.5 Months)
Comprehensive maintenance of Gas based fire suppression system SINOREX
1230 system comprising 2 X 90 Kgs seamless cylinder with valves and all connec
ted electromagnetic actuators and kit complete including MS seamless pipes as
ASTMA 106-250 etc in New Server Room Automatic battery charger, 24 volts
sealed lead acid batteries sufficient for 24 hours normal working and then be
capable of operating the system for 2 hours during an emergency conditions
as required. (1.5 Months)
Comprehensive maintenance of microprocessor based networkable analogue
addressable type 1-2 fire alarm control panel expandable to 10 loops each loop
are connected 252 analog addressable devices in one loop each loop are loaded
to 90% of its full capacity including comprising hooter cum storable red colour with
99 db sound output VESDA detector for New Server Room. Automatic battery
charger, 24 volts sealed lead acid batteries sufficient for 24 hours normal
working and then be capable of operating the system for 2 hours during an
emergency conditions as required. (1.5 Months) | 1 | Job | 3,98,800 ₹3,98,800 | 3,98,300 ₹3,98,300 | 3,87,900 ₹3,87,900 Lowest | 3,99,999 ₹3,99,999 |
Tender Value
Refer Docs
Closing Date
8 Oct 2026, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE UTILITY PLANT AND MACHINERY DELHI CANTT-10
GE UTILITY PLANT AND MACHINERY KIRBY PLACE DELHI CANTT-10
COMPREHENSIVE MAINTENANCE OF FIRE ALARM SYSTEM AND FIRE ALARM CUM GAS SUPPRESSION SYSTEM FOR OLD NEW SERVER ROOM AT DIPAC UNDER GE U P AND M DELHI CANTT
2026_MES_791579_1
GE(U)/PM/3011/B/JO/34/E3
Limited
Miscellaneous Works
Piece-work
30 days
Delhi Cantt
PLEASE REFER NOTICE INVITING QUOTATION
1 document required · 1 mandatory
₹0
Exempted
10 Oct 2026
29 Sept 2026
10 Oct 2026
29 Sept 2026
8 Oct 2026
29 Sept 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Comprehensive maintenance of Fire alarm and Gas based fire suppression system
comprising 2X60 Kgs seamless cylinder with valves and all connected electromag
netic actuators and kit complete including MS seamless pipes as ASTMA 106-250
etc in Old Server Room Automatic battery charger, 24 volts sealed lead acid batter
ies sufficient for 24 hours normal working and then be capable of operating the
system for 2 hours during an emergency conditions as required. (1.5 Months)
Comprehensive maintenance of Gas based fire suppression system SINOREX
1230 system comprising 2 X 90 Kgs seamless cylinder with valves and all connec
ted electromagnetic actuators and kit complete including MS seamless pipes as
ASTMA 106-250 etc in New Server Room Automatic battery charger, 24 volts
sealed lead acid batteries sufficient for 24 hours normal working and then be
capable of operating the system for 2 hours during an emergency conditions
as required. (1.5 Months)
Comprehensive maintenance of microprocessor based networkable analogue
addressable type 1-2 fire alarm control panel expandable to 10 loops each loop
are connected 252 analog addressable devices in one loop each loop are loaded
to 90% of its full capacity including comprising hooter cum storable red colour with
99 db sound output VESDA detector for New Server Room. Automatic battery
charger, 24 volts sealed lead acid batteries sufficient for 24 hours normal
working and then be capable of operating the system for 2 hours during an
emergency conditions as required. (1.5 Months) | 1 | Job | - | - |
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
finance_887476.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.37 MB
Fwdltr1.pdf
Tender Documents • 0.19 MB
TermaAndCondition1.pdf
Additional Documents • 0.35 MB
BOQ_887476.xls
BOQ • 0.25 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .