| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.0 LAccepted-AOC 67 KAILASH VIHAR TIWARIPUR BAGIA JAJMAU KANPUR 208010 | KANPUR | KANPUR NAGAR | UTTAR PRADESH | 208010 | ₹20.0 L Quoted ₹20.5 L | L1 | Accepted-AOC L1 BIDDER |
| 2 | L3₹20.7 L+₹15,600 (0.76%)Rejected-Finance 11 82 GROUND FLOOR BLOCK 11 KALYANPURI EAST DELHI DELHI 110091 | EAST DELHI | DELHI | 110091 | ₹20.7 L+₹15,600 (0.76%) | L3 | Rejected-Finance HIGHER THAN L1 BIDDER |
| 3 | L3₹22.0 L+₹1.5 L (7.34%)Rejected-Finance 361 D SHAKTI NAGAR NEAR KHAN DAIRY INDIRA NAGAR LUCKNOW 226016 | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226016 | ₹22.0 L+₹1.5 L (7.34%) | L3 | Rejected-Finance HIGHER THAN L1 BIDDER |
| 4 | L4₹22.3 L+₹1.8 L (8.71%)Rejected-Finance | ₹22.3 L+₹1.8 L (8.71%) | L4 | Rejected-Finance HIGHER THAN L1 BIDDER |
| 5 | L5₹23.0 L+₹2.5 L (12.0%)Rejected-Finance | ₹23.0 L+₹2.5 L (12.0%) | L5 | Rejected-Finance HIGHER THAN L1 BIDDER |
Tender Value
₹24.9 L
EMD Value
₹49,700
Closing Date
12 Dec 2022, 6:00 pmClosed
MAJ SRINATH PL
GE (I) KANPUR
SPECIAL REPAIR FOR REPLACEMENT OF LT OVERHEAD LINE INTO UNDERGROUND CABLES AT SOME CERTAIN AREA OF AGE E/M UNDER GE (I) KANPUR.
2022_MES_556451_2
GE(I)/KAN/T-71 2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
KANPUR
AS PER TENDER DOCUMENT
7 documents required · 7 mandatory
₹500
GE(I) KANPUR
₹49,700
Yes
9 Jan 2023
24 Nov 2022
14 Dec 2022
24 Nov 2022
12 Dec 2022
29 Nov 2022
Amount
Excavation in trenches in any type of soil n exc 1.5 mtr in width and n. exc 1.5 mtr in depth and getting out all as required for laying of cables, foundation filling of poles or stays and for rerouting of cables.
Returning filling, in including spreading, levelling, watering and well ramming in layers not exc 25 cm each all as required and complete all as specified and idrected.
Removing excavated material to a distance not exceeding 50 meters and depositing where directed at a level not exc 1.5 mtr above the starting point and complete all as specified and idrected.
M&L for sand cushioning to underground cables 8 cm thick before laying the cable and 15 cm, thick after laying, stretching and testing the cable and complete all as specified and idrected.
Supplying and laying sub class b bricks old size, size 230mm x 115mm 75mm complete all as specified and directed.
M&L for drilling manually in soft / loose soil under road / hard standing / culvert / nala of suitable bore for protection pipe upto 50 mm bore complete all as specified and as directed by Engineer in Charge. Note: Depth of bore shall not be more than 1 Mtr from original ground level.
Demolition of cement concrete (un-reinforced) in ground, floors or pavings not exceeding 15 cm thick below or above ground level complete all as specified.
M & L for PCC (1:2:4) type B-1 using 20mm graded stone aggregate as in floor / hard-standing, surface finished even and smooth without using extra cement to match with the existing surface complete all as specified.
Supply and laying in trenches or fixing to wall/pole or passing through pipe XLPE insulated heavy duty electric cable with aluminium conductor 1100 volts grade cross sectional area 120 Sqmm 3.5 core.Make of cable Polycab/Plaza/ Grandlay/Havells. (Note : Incl making good all distributed wall surfaces/ flooring/tilling to match with existing specification)
All as per item No-09 but cable of size 70 Sqmm 3.5 core and complete all as specified and idrected.
All as per item No-09 but cable of size 50 Sqmm 3.5 core and complete all as specified and idrected.
All as per item No-09 but cable of size 35 Sqmm 3.5 core and complete all as specified and idrected.
All as per item No-09 but cable of size 25 Sqmm 4 core and complete all as specified and idrected.
All as per item No-09 but cable of size 16 Sqmm 4 core and complete all as specified and idrected.
All as per item No-09 but cable of size 10 Sqmm 4 core and complete all as specified and idrected.
All as per item No-09 but cable of size 6 Sqmm 2 core and complete all as specified and idrected.
Material and labour for GI tubing light grade 50mm bore with fittings laid for protection of cable under road crossing fixed to walls or pole complete all as specified and as directed.Make-Jindal/Tata/Prakash
All as per srl item No 17 but 40mm bore and complete all as specified and idrected.
All as per srl item No 17 but 20 mm bore and complete all as specified and idrected.
Cable jointing kit for 1100 volt grade cable for outdoor/indoor termination end joint heat shrinkable type complete with jointing material and accessories suitable for XLPE/PVC armoured aluminium conductor cable of size 16 to 35 Sqmm 3.5/4 core.
All as per item No 20 but for 50 to 95 Sqmm size and complete all as specified and idrected.
All as per item No 20 but for 120 to 185 Sqmm size and complete all as specified and idrected.
Supply & fix of cable PVC insulated flexible Copper conductor cable of size 1.5 Sqmm 3 core cut to pieces all as required for connetion with proper thimbles, drawn in existing/new GI pipe fixed to wall or pole all as directed by Engr-in-charge.Make-Plaza/Havells/Grandlay
S&F in repair weatherproof junction box of size 400 x 300 x 190mm outdoor type made out of thermo polycorbonate to accommodate 04 Nos aluminium bus bar of size 25x6mm rating 200 Amps and MCB SP 6 Amps IP-65 with hinges door and triangular locks water proof, shocked proof, rust proof, corrosion free, acid resistance/ fire retardent and self extinguishing UV resistance complete fixed on pole with flat iron clamps of size 25 x 3mm, nuts, bolts, washers etc including two coats of synthetic enamel paint over a coat of redoxide zinc chrome primer on iron/ steel parts complete all as specified and as directed. Make Sintex/ Hansel/ Hager as approved by GE(I).
Supply and installation, connecting electically & commissioning of LT feeder pillar box outdoor type of size 0.90 x 0.60 x 0.50 Mtr size factory fabricated made out of MS sheet of thickness 3.15 mm front door openable with locking arrangement mounted on angle iron legs made out of angle iron of size 40x40x6mm, 1.5 mtr long, 1.0 mtr above ground level and 0.50 mtr embedded in PCC blocks of size 0.30x0.30x0.50 mtr- 04 Nos duly painted with two coats of synthetic enamel paint over a coat of red oxide complete with 200 amps rated aluminium bus bar suitable for 3 phase 4 wire supply system duly drilled holes and making all cable connection with proper thimbles mounted on epoxy based post insulators and one MCCB 200 Amps 4 pole 415 Volt, 35 KA of make : Legrand/Havells/L&T complete all as required at site.
Dismantling from insulators and taking down ACSR conductor any size from HT/LT over head lines and depositing to MES store yead and complete all as specified and idrected.
Dismantling insulator any type and any size from LT over head lines and fixing other side or depositing to MES store yard and complete all as specified and idrected.
Dismantling, cross arms, clamps, supports made of channels or angle section etc including nuts and bolts and setting aside for reuse on the same or new location or depositing to MES store yard all as required at site and complete all as specified and idrected.
Dismantling stay assy complete including excavation for taking out PCC block breaking of PCC block for taking out MS plate and depositing iron item to MES store yard and removing of PCC from site.
Dismantling steel poles any type and any size including excavation for taking out pole, breaking of PCC block with due care and setting aside all as spfd and directed .
Supply,installing, testing and commissioning Outdoor type LT feeder piller box of suitable size, padestal mounted, CPRI approved factory made totally enclosed, dust and vermin proof, double door, front side openable, type IP 54 protection made of CRCA sheet 3.15 mm thick of size as per IS and having proper locking arrangement in front side door suitable for 440 volts, 50 Hz, 3 phase 4 wire system including cable glands of suitable size for incoming and outgoing cables and comprising with and including following accessories and mounted on PCC Plat form min 45 cm from ground level and grouted in PCC 1:3:6, 100 mm thick, 0.5 m all round the panel board including dismantling old unsv LT feeder piller box / busbar chamber etc complete with the following items housed in :- BUSBAR :- 400 Amps rated copper bus bar TPN duly insulated with coloured PVC sleeve as per standard colour code and rigidly mounted on bakelite / DMC insulator bus bar support (Square / round) insulators of suitable size and good insulation resistance (Busbar to MCCB shall be connected through suitable size of copper busbar). INCOMING:- (i) 4 pole MCCB of capacity 400 Amps, 415 Volts, 50 Hz, 3 phase breaking capacity 35/36 KA with thermal megnatic release type - 01 No. (ii) Digital multifunctional meter VAF. (iii) Indicator lamp with integral circuit (230/240 volt) and cluster LED (RED, ORANGE, BLUE) -01 set (iv) CT (200/5A) -03 Nos OUTGOING:- (a) 4 pole MCCB of capacity 200 Amp, breaking capacity 25 KA with thermal magnetic release, adjustable type with rotary handle - 02 Nos a) 4 pole MCCB of capacity 100 Amp, breaking capacity 25 KA with thermal magnetic release, adjustable type with rotary handle - 02 Nos. Make of panel : L&T / SIEMENS / LEGRAND / C&S/ SCHNEIDER / ABB / HAVELLS . Panel and its switchgear i.e. MCCB / MCB shall be of same manufacturers.
Supply,installing, testing and commissioning Outdoor type LT feeder piller box of suitable size, padestal mounted, CPRI approved factory made totally enclosed, dust and vermin proof, double door, front side openable, type IP 54 protection made of CRCA sheet 3.15 mm thick of size as per IS and having proper locking arrangement in front side door suitable for 440 volts, 50 Hz, 3 phase 4 wire system including cable glands of suitable size for incoming and outgoing cables and comprising with and including following accessories and mounted on PCC Plat form min 45 cm from ground level and grouted in PCC 1:3:6, 100 mm thick, 0.5 m all round the panel board including dismantling old unsv LT feeder piller box / busbar chamber etc complete with the following items housed in :- BUSBAR :- 315 Amps rated copper bus bar TPN duly insulated with coloured PVC sleeve as per standard colour code and rigidly mounted on bakelite / DMC insulator bus bar support (Square / round) insulators of suitable size and good insulation resistance (Busbar to MCCB shall be connected through suitable size of copper busbar). INCOMING:- (i) 4 pole MCCB of capacity 315 Amps, 415 Volts, 50 Hz, 3 phase breaking capacity 35/36 KA with thermal megnatic release type - 01 No. (ii) Digital multifunctional meter VAF. (iii) Indicator lamp with integral circuit (230/240 volt) and cluster LED (RED, ORANGE, BLUE) -01 set (iv) CT (200/5A) -03 Nos OUTGOING:- (a) 4 pole MCCB of capacity 100 Amp, breaking capacity 25 KA with thermal magnetic release, adjustable type with rotary handle - 04 Nos. a) 4 pole MCCB of capacity 63 Amp, breaking capacity 25 KA with thermal magnetic release, adjustable type with rotary handle - 01 Nos. Make of panel : L&T / SIEMENS / LEGRAND / C&S/ SCHNEIDER / ABB / HAVELLS . Panel and its switchgear i.e. MCCB / MCB shall be of same manufacturers.
M&L for Earthing complete with galvanised cast iron earth plate electrode of size 600x600x6.3 mm thick as earth electrode with top edge of the earth plate not less than 1.5mtr below ground level using galvanised iron strip 32x6mm as earth continuity conductor connected to earth plate by means of GI thimbles nuts bolts washers all as directed including providing earth wire protection pipe GI light grade 40mm dia from earth plate to main switch board/panel, watering pipe 20mm dia with wire mesh and funnel at top, earth pit and RCC pit cover in PCC 1:3:6 adequate quantity of charcoal dust and salt all around the earth plate, earth work in any type of soil reaming surplus excavated material all as required at site and specified in EP No 5 of SSR part I 1991 or directed incl testing on completion and complete all as specified and idrected.
Bharat Sales Corporation
Eco Creations
S B ENTERPRISES
SAKSHAM SUPPLIERS BUILDERS
VEE KAY ENTERPRISES
Sagar Electricals
G S SANDHU & CO.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .