Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.7 LAccepted-Finance | ₹2.7 L | L1 | Accepted-Finance L1 |
| 2 | L2₹5.1 LAccepted-Finance | ₹5.1 L | L2 | Accepted-Finance L2 |
| 3 | L3₹7.3 LAccepted-Finance | ₹7.3 L | L3 | Accepted-Finance L3 |
| 4 | L4₹12.4 LAccepted-Finance | ₹12.4 L | L4 | Accepted-Finance L4 |
| 5 | Rejected-Technical | - | - | Rejected-Technical Eligibility has not been fulfilled |
| Sl No | Description | Qty | Unit | AAYANSH ELECTRICAL SOLUTIONS L3 | M/S YASH TRADERS HAPUR L2 | Singh Heavy Electricals L1 | M/s Ashu Brothers L4 |
|---|---|---|---|---|---|---|---|
| 1.00 | Carriage of all petty material of estimate, from Electricity store center, Hapur to 33/11KV Sub-Station/site of work with loading and unloading at both ends on Kachha Packka road, as per direction of site incharge from JE Store/Store center Hapur/Ghaziabad/Bulandshar (0-50 Km) | 1 | Qtl. | 500 ₹500 | 1,000 ₹1,000 | 280 ₹280 | 500 ₹500 |
| 2.00Carriage of following material from Electricity store center, Hapur/J.E. Store to site of work with loading and unloading at both ends on Kachha Packka road, as per direction of site incharge from JE Store/Store center Hapur/Ghaziabad/ Bulandshar (0-50 Km). | |||||||
| 2.01 | ST Pole 11/13 mtrs. Long | 1 | Nos. | 1,200 ₹1,200 | 900 ₹900 | 400 ₹400 | 1,200 ₹1,200 |
| 2.02 | PCC Pole 11 mtrs. Long | 1 | Nos. | 2,000 ₹2,000 | 2,500 ₹2,500 | 750 ₹750 | 2,000 ₹2,000 |
| 2.03 | PCC Pole 8.5/9.0 mtrs. Long | 1 | Nos. | 1,200 ₹1,200 | 500 ₹500 | 500 ₹500 | 1,200 ₹1,200 |
| 2.04 | STP Pole 9.0 Mtrs long | 1 | Nos. | 2,000 ₹2,000 | 500 ₹500 | 500 ₹500 | 1,200 ₹1,200 |
| 2.05 | 11KV Xlpe Cable 3x70/3x120/3x185/3x300 sq.mm | 10 | Mtrs | 100 ₹1,000 | 70 ₹700 | 30 ₹300 | 20 ₹200 |
| 2.06 | 33KV Xlpe Cable 3x120/3x185/3x300 sq.mm | 10 | Mtrs | 100 ₹1,000 | 110 ₹1,100 | 65 ₹650 | 20 ₹200 |
| 2.07 | Single phase AB Cable 35/50/95 sq.mm | 1 | Nos. | 100 ₹100 | 60 ₹60 | 15 ₹15 | 5 ₹5 |
| 2.08 | Three phase AB Cable 3x50/3x95/3x120 sq.mm | 10 | Mtrs | 100 ₹1,000 | 80 ₹800 | 20 ₹200 | 5 ₹50 |
Tender Value
₹50 L
EMD Value
₹50,000
Closing Date
2 Jan 2026, 12:00 pmClosed
SUPERINTENDING ENGINEER
SUPERINTENDING ENGINEER EDC HAPUR
FOR VARIOUS ELECTRICITY LINE WORK AND OTHER ASSOCIATED WORKS, IN DEPOSIT SCHEME (RUNNING CONTRACT), IN THE JURISDICTION OF EDD-HAPUR, UNDER EDC., HAPUR.
2025_PVVNL_1101982_1
42(W)/EDCH/2025-26
Open Tender
Electrical Works
HAPUR
Please refer Tender documents.
2 documents required · 2 mandatory
₹3,540
SUPERINTENDING ENGINEER, EDC, HAPUR
₹50,000
9 Jan 2026
26 Dec 2025
2 Jan 2026
26 Dec 2025
2 Jan 2026
26 Dec 2025
Amount
Carriage of all petty material of estimate, from Electricity store center, Hapur to 33/11KV Sub-Station/site of work with loading and unloading at both ends on Kachha Packka road, as per direction of site incharge from JE Store/Store center Hapur/Ghaziabad/Bulandshar (0-50 Km)
Carriage of following material from Electricity store center, Hapur/J.E. Store to site of work with loading and unloading at both ends on Kachha Packka road, as per direction of site incharge from JE Store/Store center Hapur/Ghaziabad/ Bulandshar (0-50 Km).
ST Pole 11/13 mtrs. Long
PCC Pole 11 mtrs. Long
PCC Pole 8.5/9.0 mtrs. Long
STP Pole 9.0 Mtrs long
11KV Xlpe Cable 3x70/3x120/3x185/3x300 sq.mm
33KV Xlpe Cable 3x120/3x185/3x300 sq.mm
Single phase AB Cable 35/50/95 sq.mm
Three phase AB Cable 3x50/3x95/3x120 sq.mm
11 KV CT/PT Unit
33 KV CT/PT Unit
11 KV Metering Cubical
33 KV Metering Cubical
11 KV VCB
Carriage of following capacity transformer from Electricity store center, Hapur to site of work with loading and unloading at both ends on Kachha Packka road, as per direction of site incharge from JE Store/Store center Hapur/Ghaziabad/ Bulandshar (0-50 Km).
(C) 250 to 400 KVA
Erection of 11KV Four-pole structure after digging of suitable pits on following pole with fabrication and fixing of M.S. Top & Dropper Channel, M.S. T/F Angle, E-Bracket, 11 KV Pin insulator with Pin, Disc Insulator with Disc fitting etc., as per RESPO Drawing/Norms by providing all clamps made of M.S. Flat of size 50x6 mm with proper size nuts and bolts and Stone Pad with jumpering etc work, and as per direction of site incharge. All Clamp & Nut bolt will be provided by contractor.
PCC Pole 8.5 Mtrs
PCC Pole 11 Mtrs
ST Pole 13 Mtrs
Erection of 33KV Four-pole structure after digging of suitable pits on following pole with fabrication and fixing of M.S. Top & Dropper Channel, M.S. T/F Angle, E-Bracket, 33 KV Pin insulator with Pin, Disc Insulator with Disc fitting etc., as per RESPO Drawing/Norms by providing all clamps made of M.S. Flat of size 65x8 mm with proper size nuts and bolts and Stone Pad with jumpering etc work, and as per direction of site incharge. All Clamp & Nut bolt will be provided by contractor.
PCC Pole 11 Mtrs
ST Pole 13 Mtrs
Erection & Fixing of single pole structure of following pole of I l KV line along with X-Arm and pin insulator after digging of suitable pits including fixing of requisite all accessories as per RESPO Drawing norms by providing F-Bracket and holding Clamps made of M.S. Flat of size 50x6 mm with proper size nuts and bolts, Stone Pad with as per direction of site incharge.
PCC Pole 8.5 Mtrs
PCC Pole 11 Mtrs
ST Pole 9 Mtrs
ST Pole 13 Mtrs
Erection & Fixing of single pole structure of following pole of 33 KV line along with X-Arm and pin insulator after digging of suitable pits including fixing of requisite all accessories as per RESPO Drawing norms by providing F-Bracket and holding Clamps made of M.S. Flat of size 65x8 mm with proper size nuts and bolts and Stone Pad with as per direction of site incharge.
PCC Pole 11 Mtrs
PCC Pole 9 Mtrs
ST Pole 13 Mtrs
Erection & Fixing of single pole structure of following pole of LT line along with with shakle insulator after digging of suitable pits including fixing of requisite all accessories as per RESPO Drawing norms by providing holding Clamps made of M.S. Flat of size 35x5 mm with proper size nuts and bolts and Stone Pad with as per direction of site incharge.
PCC Pole 8.5 Mtrs
ST Pole 9 Mtrs
Erection of double pole structure for 33KV Line after digging of suitable pits on following pole. with fabrication and fixing of M.S. Top & Dropper Channel, M.S. T/F Angle, E Bracket, 33KV Pin insulator with Pin, Disc Insulator with Disc fitting etc., as per RESPO Drawing/ Norns by providing all clamps made of M.S. Flat o size 65x8 mm with proper size nuts and bolts and Stone Pad with jumpering etc work, as per direction of site incharge. All Clamp & Nut bolt will be provided by contractor.
PCC Pole 11 Mtrs
PCC Pole 9 Mtrs
ST Pole 13 Mtrs
Erection of double pole structure for 11KV Line after digging of suitable pits on following pole. with fabrication and fixing of M.S. Top & Dropper Channel, M.S. T/F Angle, E Bracket, 11KV Pin insulator with Pin, Disc Insulator with Disc fitting etc., as per RESPO Drawing/ Norns by providing all clamps made of M.S. Flat o size 50x6 mm with proper size nuts and bolts and stone pad with jumpering etc work, as per direction of site incharge. All Clamp & Nut bolt will be provided by contractor.
PCC Pole 8.5 Mtrs
PCC Pole 11 Mtrs
ST Pole 9 Mtrs
ST Pole 13 Mtrs
Grouting of following ST/PCC supports in CC 1:3:6 (Cement, sand & 40mm brick ballast) Grouting will be done in the block of size (450x450)mm x1/6th of full length of the support, up to ground level, 300mm plinth above the ground level with CC 1:3:6 (Cement, core sand and Stone grit) with mufting as per drawing, work includes back filling & proper ramming by providing all required grouting materials, as per direction of site incharge.
STP 13 Mtrs Long
PCC/STP Pole 8.5/9.0 mtr. Long
ST/PCC Pole 11 mtr. Long
Erection & Fixing of 11KV. Fuse set on STP/PCC Pole, by providing all required fixing materials as per RESPO/Norms and as per direction of site incharge. (Only Fuse Set will be provided by the Department.
Providing, Erection & Fixing of 11KV. TPMO set on STP/PCC Pole, by providing all required fixing materials as per RESPO/Norms and as per direction of site incharge. (Only TPMO Set will be provided by the Department).
Providing Erection & Fixing of 3 Phase LT Distribution Box on pole by providing 02 Nos. DIB Clamps & proper size nut & bolts, Jumpring wire as per direction of site incharge.
Construction of T/F plinth suitable for 160/250/400 KVA T/F (size 2x2x1.5 mtr) after digging of earth and construction with 14 bag cement, fine sand, Coarse.sand, Brick Ballast, 1st Class Bricks 6000, Stone Ballast (40mm), MS Channel 125x65mm (54 kg), MS Twisted bar 20 mm (50 kg) & ramming the same, including cost of all material & labour, as per direction of site incharge. (all matreial/ labour/ T&P use for construction of plinth will be provided by contractor)
Construction of safety fencing (MS) size 3x3x2 mtr. for Dist. Transformer 11/0.4 KV Sub Station, With supply of material required for MS fencing (50X50X3 MM) M.S. wire mesh construction utilizing vertical post duly grouted/fitted in ground/on floor. Horizontal angle/T-iron to be fitted on vertical posts. Pickets (if required) fitted to rail and gate to facilitate entry and exit. The vertical Posts/Horizontal post shall be made of M.S. angle 65x65x6mm. Such post shall be kept preferably at distance of 800-1000 MM. and shall be grounded with CC ratio 1:4:8. The length of vertical post shall be sufficient to take care of fencing as requirement at site, and as per direction of site incharge. (all matreial/ labour/ T&P use for construction of plinth will be provided by contractor)
Safely installing and fixing the New following capacity transformer with the help of crane/manual labour at LT Sub-Station Double Pole/Plinth, as per direction of site incharge. All clamps and nut bolt will be provided by contractor
(C) 250 to 400 KVA
Safely installing and fixing the following CT/PT Unit with the help of crane/manual labour at Sub-Station Double Pole, as per direction of site incharge. All clamps and nut bolt will be provided by contractor
11 KV CT/PT
33 KV CT/PT
Laying of overhead 11KV ABC/XLPE of various capacity on STP/PCC Pole. Work include hanging of 11 KV Cable properly with the help of necessary clamps and complete work properly as per RESPO Norms and as per direction of site incharge.(Rate will be charge as per actual length of work). All clamps and nut bolt will be provided by contractor
Laying of overhead LT ABC of various capacity on STP/PCC Pole. Work include hanging of LT Cable properly with the help of necessary clamps and complete work properly as per RESPO Norms and as per direction of site incharge.(Rate will be charge as per actual length of work). All clamps and nut bolt will be provided by contractor
(a) Single Phase LT ABC
(b) Three Phase LT ABC
Laying of following LT PVC Cable of all size on STP/PCC pole overhead and complete work properly, as per RESPO Norms, and as per direction of site incharge. All clamps and nut bolt will be provided by contractor.
Single Core
Three Core
Laying of following O/D PN-4PE-80 PN-4 grade UV stabilized HDPE pipe from drill method/trenchless as per IS of 6meter, for laying of underground Cable as per RESPO/Norms, including cost of above HDPE pipe, as per direction of site incharge. (Rate will be charge as per actual length of work)
140 mm dia
160 mm dia
200 mm dia
Laying of following XLPE Cable undergound into HDPE Pipe, spare cable shall be left in the loop shape at both ends as per RESPO/Norms, as per direction of site incharge.(Rate will be charge as per actual length of work)
(a) 33 KV XLPE Cable of size 3x185/3x240/3x300 sq.mm
(b) 11 KV XLPE Cable of size 3x70/3x120/3x185/3x240/3x300 sq.mm
Digging of earth 30 cm width single core cable 1.0 meter deep and refling and finishiung as same with road restoration charge for laying of 33 KV/11 KV XLPE Cable as per RESPO/Drawing Norms. (The Firm will be fully responsible for this work and taking necessary permission), as per direction of site incharge (Rate will be charge as per actual length of work).
Foot path/ Kaccha Road
Pucca Road
Digging of earth 60 cm width double cable 1.0 meter deep and refling and finising as same with road restoration charge for laying of 33 KV/11 KV XLPE Cable as per RESPO/Drawing Norms. (The Firm will be fully responsible for this work and taking necessary permission), as per direction of site incharge (Rate will be charge as per actual length of work).
Foot path/ Kaccha Road
Pucca Road
After digging of pit laying of underground Cable with 1st class pucca brick and concrete sand as per RESPO/Norms as per direction of site incharge. Only XLPE/ PVC Cable will be provided by department.
11KV 3x70 sq.mm.
11KV 3x120 sq.mm.
11KV 3x185 sq.mm.
33 KV 3x120 sq.mm.
33 KV 3x300 sq.mm.
Fabrication & Fixing of T off-Channel on pole by providing Holding Clamps, F-Clamps & Proper size nuts & bolts, as per RESPO/Norms and as per direction of site incharge.
Fabrication of Guarding Angle other requisites material for guarding by drawing 02Nos G.I Wire and making loop at suitable distance as per RESPO drawing/Norms by providing holding clamps, 02Nos. Eye bolts made of M.S. round size 12mm dia-100mm long & Cross Arm clamps made of M.S. Flat of size 50X6mm and bolts as per norms of RESPO Lucknow, and as per direction of site incharge. (only Guarding Angle & GI Wire will be provided by Department).
Wrapping of barbed wire on ST/PCC poles as anti-climbing device for a length of 0.9mtrs. Wire pitch/gap 13mm and fixing upper and lower end keeping lower end at a hieght of 2.75 mtr from the ground complete, including providing & fixing of lower end & upper end clamps made of M.S. Flat 40X5mm complete with nuts & bolts and all other required material and T&P., as per direction of site incharge.
Grouting & fixing of stay rods (20x1800)mm including all work of excavation, cement concrete in size (0.60x0.60x0.30)m in ratio 1:4:8 cement, sand, 40mm brick ballast as per drg. Including back filling, proper ramming etc and fixing tightening & nozzling of stay wire with stay rod with the poles of required tension as per drawing as per RESPO Drawing/Norms by providing all grouting material and stay clamp made of M.S. Flat of size 50x6mm with proper size bolts & nuts & loops, as per direction of site incharge.
Earthing of supports with MS earth Rod of (20x2500)mm long including excavation of pit and driving M.S. Rod 3.0 M apart from support and 0.5m below the ground level and connection below the earth electrodes with the help of G.I. wire & earthing lugs as per RESPO Drawing/Norms by providing proper size nuts & bolts, as per direction of site incharge. only earth rod and GI wire will be provided by department.
Providing and fixing Earthing of neutral & body of T/F By Boring and lowering of G.I. Pipe size 32 mm dia… into the ground up to water level 120 fit. With the lower end of solid copper cone approx. 225mm long and 750 gm. in weight shall be provided and screwed in pipe as well as bringing out a continuous copper wire 6 SWG from the cone up to the ground surface where it will be bolted to the M.S. earth strip for T/F neutral connection, the earth strip will be welded to the G.I. pipe and neutral earthing support, as per direction of site incharge.
Providing & Fixing of G.I. pipe 6"dia Class-B over 11KV/33 KV XLPE cable before mounting the cable at double pole. The work includes fitting of clamps, sealing of top and bottom of pipe and one end of pipe is to be burried under earth about 500mm earch including mounting and clamping the cable on double pole structure and making connection with overhead line at both ends, as per direction of site incharge.
Providing and fixing of Suspension Clamp with Eye Hook as per RESPO/Norms and as per direction of site incharge.
Providing and fixing of Dead End Clamp with Eye Hook, as per RESPO/Norms and as per direction of site incharge.
Providing & Fixing of Stone Pad 300x300x75 mm as per RESPO/Drawing Norms and per direction of site incharge.
Providing and Fixing of complete LT Pannel with arrangement of 3 phase LT MCCB and Bus Bar for 24 Nos cable service as per instruction of site incharge
Providing & Fixing of Danger Board, including fixing of all accessories by providing all required materials (like suitable clamps, nuts & bolts etc.) as per RESPO/Drawing Norms and as per direction of site incharge.
Providing & Fixing of Number Plate alongwith all required accessories (like suitable clamps, nuts & bolts etc.) as per RESPO/Drawing Norms and as per direction of site incharge.
Making and filling of 11KV Cable Jointing Kit, Indoor/outdoor type, after duly plumbing and taping of suitable XLPE Cable, providing, fixing and crimping of proper size good quality lugs, including cost of lugs and tape etc., as per RESPO Norms, and as per direction of site incharge.
Making and filling of 33KV Cable Jointing Kit, Indoor/outdoor type, after duly plumbing and taping of suitable XLPE Cable, providing, fixing and crimping of proper size good quality lugs, including cost of lugs and tape etc., as per RESPO Norms, and as per direction of site incharge.
Installation of Metering Cubical Complete work as per RESPO Norms, and as per direction of site incharge.
Providing 2 coat Red Oxide paint ISI Make & Painting of 11/13 Mtr ST supports its as per RESPO/Norms and as per direction of site incharge. All material provided by contractor.
Providing 2 coat alluminium paint & Painting of 11/13 Mtr ST supports by its as per RESPO/Norms and as per direction of site incharge. All material provided by contractor.
diging of pit with Manual digging method and laying of O/D PN-6PE-80 PN-4 grade UV stabilized HDPE pipe as per IS of 6 meter long, for laying of underground Cable as per RESPO/Norms, including cost of above HDPE pipe, as per direction of site incharge.
140 mm dia
160 mm dia
200 mm dia
Laying , Stringing and final sagging of ACSR Weasel Conductor, as per RESPO/ Drawing Norms and as per direction of site incharge.
Laying , Stringing and final sagging of ACSR Rabbit Conductor, as per RESPO/ Drawing Norms and as per direction of site incharge.
Laying , Stringing and final sagging of ACSR Dog Conductor, as per RESPO/ Drawing Norms and as per direction of site incharge.
Providing and fixing of Al Lugs of T/F
Providing and installation of maintenance free multifaceted proactive and corrosion free chemical earthing electrod size 80mm x 3000mm complete with 50KG backfill compound with all required accessories for Body/neutral earthing of Transformers, including cost of M.S. earth strip for connection the earth strip will be welded to the earthing and neutral support, as per RESPO/Norms and as per direction of site incharge.
Jumpheing work of LT/HT line for proper energization of line.
Safely dismantling work properly and carriage of old & used STP pole & other material from site of work to Electricity store center, Hapur with loading and unloading at both ends on Kachha Packka road, as per direction of site incharge.
ST Pole 11/13 mtrs. Long
Iron Scrap
ABC/PVC/XLPE Cable
Rail pole
Safely dismantling/removal and carriage of old & used ACSR Conductor from site of work to Electricity store center, Hapur with loading and unloading at both ends on Kachha Packka road, as per direction of site incharge.
Saftly dismantling work properly and carriage of old & used Transformer's from site of work to Electricity store center, Hapur with loading and unloading at both ends on Kachha Packka road, as per direction of site incharge.
(C) 250 to 400 KVA
Saftly dismantling work properly and carriage of old & used 11 KV CT/PT, 33 KV CT/PT and metering cubical from site of work to Electricity store center, Hapur with loading and unloading at both ends on Kachha Packka road, as per direction of site incharge.
11 KV CT/PT
33 KV CT/PT
33 KV/ 11KV Metering Cubical
Carrage of old & used conductor and opening of all accessories. (Iron/steel Scrap) including carriage of above material from site of work to JE Store/ESC-Hapur. With loading and unloading at both ends on Kachha Packka road as per direction of site incharge.
Installing of 11 KV VCB properly with grouting and making all connection properly for safe energization.
Providing and making jointing kit of 3 phase LT Cable as per RESPO/Norms and as per direction of site incharge.
3x120 sq.mm
3x240 sq.mm
3x400 sq.mm
Providing and making jointing kit of 1 phase LT Cable as per RESPO/Norms and as per direction of site incharge.
1x120 sq.mm.
1x240 sq.mm
1x400 sq.mm
M/S YASH TRADERS HAPUR (BID ID -5785976)
AAYANSH ELECTRICAL SOLUTIONS (BID ID -5774261)
M/s Ashu Brothers (BID ID -5786226)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.79 MB
BOQ_2031740.xls
BOQ • 0.32 MB
Standbidnew42.pdf
Tender Documents • 0.70 MB
Download all tender documents and submit your bid