Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.4 LAccepted-AOC 15 BOH ROAD DEFENCE ENCLAVE AMBALA CANTT 133001 HR | AMBALA | HARYANA | 133001 | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹29.4 L+₹5.0 L (20.5%)Rejected-Finance GARDEN AVENUE PLOT NO 242 243 244 RH 4 SECTOR 21 NERUL NAVI MUMBAI 400 706 | THANE | MAHARASHTRA | 400706 | L2 | Rejected-Finance BEING NOT L1 | |
| 3 | L3₹29.5 L+₹5.2 L (21.1%)Rejected-Finance | L3 | Rejected-Finance BEING NOT L1 | |
| 4 | L4₹30.2 L+₹5.8 L (23.8%)Rejected-Finance | L4 | Rejected-Finance BEING NOT L1 |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
2 Mar 2022, 6:00 pmClosed
GE NW KARANJA
NAVAL STATION KARANJA, URAN, RAIGAD, MAHARASHTRA
REPAIRS TO SUNKEN FLOOR, AC SHEET, TILING WORK AND MISC B/R WORKS UNDER AGE B/R-II AREA AT NAVAL STATION KARANJA
2022_MES_505885_1
8490/E8
Open Tender
Civil Works
Item Rate
180 days
GE NW KARANJA
REPAIRS TO SUNKEN FLOOR, AC SHEET, TILING WORK AND MISC B/R WORKS UNDER AGE B/R-II AREA AT NAVAL STATION KARANJA
8 documents required · 8 mandatory
₹500
Yes
GE NW KARANJA
₹90,000
Yes
9 Mar 2022
4 Feb 2022
4 Mar 2022
4 Feb 2022
2 Mar 2022
18 Feb 2022
4 Feb 2022 - 18 Feb 2022
Amount
Demolition of cement concrete (unreinforced) in ground floors and paving not exceeding 15 cm thickness (below or above ground level) complete all as specified and directed.
M&L PCC 1:4:8 type D-2 using 40 mm graded aggregate as in sub base to flooring complete all as specified and as directed.
Dismantling of stone slabs & tiles of any description or thickness in floor aprons, cills etc laid bedded & pointed in any mortar complete all as specified and directed.
M&L for chequered cement concrete tile 30cmX30cmX 20 to 25mm thick set jointed and pointed in neat cement siurry in floor with grey cement and pig ments over 20mm thick screed bed or bedding layer of CM (1:6) complete all as specified and as directed.
M&L for 80 mm thick pre-cast cement concrete interlocking shot blasted, heavy duty mono layer paver block (coloured), machine pressed of approved size and shape laid and compacted with using vibrator complete all as specified & directed .
Material and labour for 50 mm thick sand cushioning for laying interlocking paver block complete all as specified and directed.
S&F Granite tile of 20mm thick vertical surfaces such as skirting/dado, machine cut bedded and jointed with grey white cement slurry and pointed with white cement with add mixture of pigment to match the shade of granite stone including cutting and polishing including 15mm thick screed bed or bedding layer of mortar in CM 1:4 for laying in vertical surfaces, complete all as specified and directed
S&F green marble 17/18 mm thick machine cut, jointing and pointing with white cement slurry including 20mm thick screed bed or bedding layer of mortar in CM 1:6 complete all as specified and directed.
M&L for 100mm thick PCC (1:2:4) type B-2, using 40mm graded stone aggregate as in hardstanding, surface finished even & fair without using extra cement complete all as specified and as directed.
Dismantling, floor, hearth or wall tiling including cement mortar bedding complete.
M & L for Non Skid ceramic tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match incl 20 mm thick screed bed in cm (1:6) for laying floor fineshes complete all as specified and directed.
M&L non skid coloured ceremic tiles 7 to 8 mm thick (Square/rectangular) area of each tile exceeding 0.18 Sqm but not exceeding 0.38 Sqm, as in floors over screed bed or bedding layer of morar 15 mm in cement mortar 1:6 set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface complete all as specified and as directed.
M&L for Glazed ceramic colour tiles 300x200x5 to 7 mm thick as in skirting,dados, risers to steps,etc,set and jointed in neat cement slurry and pointed in colour cement to match tiles, over and including 10 mm thick rendering or bedding layer in cement mortar 1:4 complete all as specified and directed.
M & L for Glazed ceramic tiles in vertical surface 350mmx250mm x7mm / 450X350X7mm thick, set and jointed in neat cement slurry and pointed in white or coloured cement to match incl 15 mm thick screed bed in cm (1:4) for laying floor fineshes complete all as specified and as directed. Make : KAJARIA/ORIENT BELL / JOHNSON / SOMANY
Taking down cement plaster on brick or stone walls, etc., including raking out joints, hacking for key, scrubbing down with water, etc. complete all as specified and directed.
Demolition of brick work built in cement or cement lime mortar including rubbish off the premises complete all as specified and directed.
M&L for Brick work with sub class ‘B’ bricks, straight or curved on plan exceeding 6m mean radius, built in cement mortar 1:6 complete all as specified and directed.
M&L using ready mix plaster for rendering 20 mm thick on fair faces of brick/concrete surfaces with two coats i.e (15 mm thick backing coat and 5mm thick finishing coat) , finished even and smooth complete all as specified and directed. (Note:- Item rate shall be include any height of Bldgs for scafolding as all arrangement.)
M & L using ready mix plaster Rendering 8 mm thick on fair faces of brick work or concrete surfaces finished even and smooth including Sagol finish complete all as specified. (Note:- Item rate shall be include any height of Bldgs for scafolding as all arrangement.)
S&F in repair 12 mm thick vertical toughened glass as in door shutters / partition with including stainless steel SS-304 patch fitting fixed with Anchor fastner, each glass panes shall be exceeding 1.5sqm, but not exceeding 2 sqm each, all edges of glass shall be diamond polished of make as approved by GE.
S&Fin repair 30 mm dia stainless steel handle of 60 cm long and fixed to toughned glass as per manufacturer's instructions of make- Enox or equivalent make as approved by GE.
S&F in repair stainless steel glass lock fixed to toughened glass as per manufacturer's instructions of make-Enox or equivalent make as approved by GE.
Taking down aluminium doors shutters only and dismantling all members and reassembling the same with and including new screws, new rubber gasket, new aluminium beads & cleats of existing make and also refixng the handles & mortice lock in existing postiion with and including new screws including refixing the door shutters in same opening complete all as specified and directed. Note : If broken or unserviceable glass/aluminium wire mesh/floor spring/concealed lock is replaced same will be paid separately under relevant items.
Taking down aluminium windows shutters only and dismantling all members and reassembling the same with and including new screws, new rubber gasket, new aluminium cleats of existing make and also refixng the locks & roller in existing postiion with and including new screws including refixing the window shutters in same opening complete all as specified and directed. Note : If broken or unserviceable glass/aluminium wire mesh/floor spring/concealed lock is replaced same will be paid separately under relevant items.
Taking down chowkhat or frame with shutter (without taking off shutter from the frame) not exceeding 1.5 Square Metre each , removing from the site including cutting holes required for taking out existing hold fast etc. complete all as specified and as directed.
Taking down chowkhat or frame with shutter (without taking off shutter from the frame) exceeding 1.5 sqm not exceeding 4.0 Square Metre each , removing from the site including cutting holes required for taking out existing hold fast etc.complete all as specified and as directed.
Taking down of shutters of any description n exc 1 sqm each including iron mongrey & removing from site complete all as specified and directed by Engr-in-charge.
Taking down shutter from frame exc 1 sqm but n.exc 2 sqm each including iron mongrey & removing from site complete all as specified and directed by Engr-in-charge.
S & F 2nd class hard wood plain solid straight chowkats and frame of wrought framed rebated on the solid rounded or chamfered put together with glue pinned at joints complete all as specified and directed.
S & F 30mm thick second class hard wood plain, framed,panelled shutters(any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers: supplied and fitted to chowkats complete all as specified and as directed.
Cutting holes in brick wall for inserting holdfast and making good dismantled portion by filling PCC (1:3:6) type C1 exc. half brick but n.exc one brick incl existing surface finishes complete all as specified and as directed.
S&F mild steel work, Grade Fe-410-0 or Fe- 310-0, as in flat iron (for holdfast) complete all as specified and as directed.
S&F in repairs mild steel tubing of 25 mm dia with PVC coating for curtain rod fancy type including fancy type PVC rings and brackets (wall to wall or flush to wall) for securing to curtain rod, fixed in repair complete all as specified and directed.
Supply & Fixing solid PVC door frame of size 50 mm x 47 mm made out of 5 mm plain colour PVC sheet reinforced with MS square tube and edgeswill be painted to match will printed sheet fixed in opening as per specification & drawings complete all as specified and as directed.(Make : Rajshree,Plastiwood, Sintex or equivalent as approved)
Supply and fixing factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of mild steel tube top & bottom rail mild steel frame shall be covered with heat moulded plain colour PVC “c” channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap inserted for top rail & bottom rail; Paneling of plain colour PVC sheet to be fitted in the mild steel frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement supplying & fixing in the frame at site as per specification and drawing complete all as specified and directed.
S&F for aluminium door/window/ventilator/partition, made out of extruded powder coated aluminium sections, with sliding or openable shutters including frame & necessary jointing cleats, glazing clips, powder coated aluminium snap beading,screws etc, complete and also including powder coated aluminium fittings such as cobra hinges, butt hinges, tower bolts, hooks & eyes, peg stays and handles including connected items,with and including making good to the disturbed portion with its original specifications complete all as specified and directed.
S&F for concealed star lock powder coated for aluminium window fixed as per manufacturers instructions complete all as specified & as directed.
S&F aluminium alloy wire cloth, 0.45mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed.
Hacking out old broken glass (any thickness, size, quality or description) from metal/wooden frame complete all as specified and directed.
S&F 4 mm thick sheet glass, ordinary quality , glazing with oil putty or with wooden beads, area n. exceeding 0.50 Square Metre each pane complete all as specified and as directed.
S&F 4 mm thick sheet glass, ordinary quality , glazing with oil putty or with wooden beads, area exceeding 0.50 Square Metre each pane complete all as specified and as directed.
S&F for rubber beading suitable for fixing 4mm / 5mm thick glass in aluminium window / doors etc complete all as specified and as directed.
S&F for aluminium anodised grill of design DG 104 pattern made out of 10mm dia rod fixed with and including standard aluminium frame of F section of size 23.40mmx15.30mm & 1.4mm thick all as per manufactures instructions complete all as specified & directed. Make- Deco grill or equivalant
M & L for Double action floor spring hydraulically regulated made up of minimum 1.25mm thick alum,inium alloy sheet foundation box, main ody with stainless steel cover, governing pivot made of brass, other plart made of mild steel heavy duty and fixed.
S & F floor door stopper of Aluminium alloy body and tongue, over all length of cover plate 150mm anodised with hard drawn steel spring, fixed to shutters complete all as specified and as directed.
S & F Mortice lock vertical type size 100mm 04 lever complete all as specified and as directed.
S & F Pre-laminated 18/19 mm thick partilcle baords, exterior grade, prelaminated both sides with decorative choice lamiantions complete all as specified and as directed.
S&F butt hinges size 100 extruded aluminium alloy with galvanised mild steel hinges pin anodised and fixed C-21 complete all as specified and as directed.
S&F Aluminium handle, cast type anodized size of handle 150 mm complete all as specified and as directed.
S&F 125mm long Extruded aluminimum alloy handles, fabricated type complete all as specified and as directed.
S&F Aluminium anodized, barrel tower bolt of extruded section, length of bolt 150 mm complete all as specified and as directed.
S & F in repairs Bib tap15mm dia standard of CP any colour screwd for iron pipes and fixed (minimum weight 15mm - 90 gms ) complete all as specified and directed.
S & F in repairs stop valve of CP any colour high presure screwd for iron pipes and fixed (minimum weight 15mm - 90 gms ) complete all as specified and directed.
Supply and fixing in repair PVC flushing cistern of 10 ltrs capacity including flush pipe PVC connection etc complete all as specified and directed.
Supply and fixing in repair 15 mm bore pillar taps cast copper alloy with capstan heads chromium plated screwed down high pressure with long screws shanks and fly nuts complete all as specified and directed.
Supply and fixing in repair white vitreous china wash down water closet pan (Pedestal pattern) with and including P or S trap, plastic seat cover closed pattern, fixing bolt etc complete all as specified and directed.
S & F in repairs Vitreous China Half stall urinal White complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60 mm long brass screws, pointing around urinal back in cement complete all as specified and directed
S&F in repair vitreous China squatting pan, ‘Orissa’ pattern, of size 580 mm x 440 mm white with integral foot rest complete including provn of cement concrete bedding and connection to trap, outgoing flushing pipe, anti syphonage pipe,CI trap 100 mm Bore of pipe etc complete all as specified and directed.
S & F in repair vitreous China wash hand basin white, flat back of size 550x400mm fixed on and including cast iron cantilever bracket, 32mm dia waste coupling including fixing of tap, waste fitting etc complete all as specified and directed.
S&F 32mm dia PVC waste pipe for WHB and urinals complete all as specified and directed.
.M&L for providing 15 mm dia PVC connection 450mm longwith brass fly nut complete fixed in repairs complete all as specified and directed.
M&L for 100 mm diameter of outlet PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and directed.
Cutting holes into or through bricks wall built in cement mortar or cement mortar exc 150 sq cm but n. exc 400 sq. cm and making good in cement mortar 1:3 or cement concrete 1:2:4 type B-1 as required complete all as specified and directed.
Roughning of old concrete floor of concrete surfaces by picking, sweeping, cleaning and washing down with water to remove dust etc complete all as specifed and directed
M&L for brushing neat cement slurry with 3Kg of cement per square metre all as specified and directed.
M&L for applying evenly a tack coat of industrial bitumen 85/25 grade at the rate of 1.2Kg/Sqm on vertical surfaces and floors of sunken portion of slabs of bath and WC after laying all CI connection brach pieces etc after covering joints with PCC (1:2:4), mixed with integral water proofing compound and inlcuding cleaning surfaces all as specified and directed.
M&L 75mm thick lime concrete with lime mortar 1:2 mix and 40mm garded coarse aggregate in sub floors complete all as specified and directed
M&L 40mm thick PCC 1:2:4 type B1, using (20mm graded stone aggregate) as in floors in sub floors complete all as specified and directed.
Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan necks, etc, removal to store (measured overall as fixed along the centre line over fittings and accessories). complete all as specified and directed.
S &F 160 mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall with stock clamps complete all as specified and directed.
S&F for PVC (SWR) bends any radius 160mm bore complete all as specified and as directed
S&F in repair 75mm bore PVC(SWR) bends any radius with access door complete all as directed.
S&F in repair 110mm bore PVC(SWR) bends any radius with access door complete all as directed.
S&Fin repair 75mm PVC(SWR) pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed.
S&Fin repair 110mm PVC(SWR) pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed.
Taking up or down steel tubing and connections 15 mm bore complete all as specified and directed.
Taking up or down steel tubing and connections 20 mm bore complete all as specified and directed.
M&L for 15 mm dia steel tube medium grade galvanized with all fittings and fixed complete in wall, ceiling or laid in floor complete all as specified and directed.
M&L for 20 mm dia steel tube medium grade, galvanised with all fitting and fixed complete to wall.
Excavating post hole ( or similar holes each exc 0.5 cum getting out returning filling in and ramming earth or broken rubble mixed with earth around with earth around in layers not exc 25 cm thick complete all specified and directed.
M&L for PCC 1:3:6 type C1 using 20mm agg for fixing angle iron post etc all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided complete all as specified and directed.
S & F steel work as in tubular trusses including special shaped washer etc complete using ERW or induction butt welded tubes confirming to IS 1161 1979 grade St 240 complete all specified and directed.
S&F for rolled sections of FE 410W (Gde-E-250)as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates complete all specified and directed.
Dismantling to plain or corrugated MS sheet any gauge, thickness including nainital or similar pattern as in roof covering complete all as specified and directed.
S&F 0.50mm thick pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet of any colour having tensile strength of 550 Mpa as in roof covering, fixed with self tapping screws etc complete all as specified and directed.
S&F 0.50mm thick pre-painted galvalume aluminium zinc coating GI based plain steel sheet of any colour having tensile strength of 550 Mpa as in valley gutter, ridge hips etc. fixed with self tapping screws etc complete all as specified and directed.
M&L Preparation of new previously untreated steel and iron surfaces of any description not other wise described over 10 centimetre width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed.
M & L applying two coats of synthetic enamel paint on new wooden surfaces incl preparation of surfaces of any description over 10 cm width or girth over a coat of pink primer including preparation of surfaces complete all as specified and directed.
Material and labour for three coat white wash on walls including preparation of new wall surfaces complete all as specified and as directed
Material and labour for preparation of new plastered surfaces of walls and applying two coat of oil distemper over and including 1-2mm thick wall care putty, and filling cavities with wall care putty filling after completely removal of existing treatment complete all as specified and as directed.
M&L for preparation of new or previously untreated plastered surfaces of walls and applying two coats of acrylic antifungal paint exterior grade paint on one coat of primer complete all as specified and as directed.
M&L for preparation of new or previously untreated plastered surfaces of walls and applying two coats of acrylic antifungal paint exterior grade paint CAMOUFLAGE PATTERN on one coat of primer complete all as specified and as directed.
Dismantling of wall paneling any type, any fixing etc. complete all as specified and directed
S&F for 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC Frame as per specification and drawing.
S&F for Solid PVC Wall Lining consisting of 5mm thick Plain colour PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specifications and drawing.
Complete removal of existing water proofing treatment of any description in any position including cleaning, wire brushing, watering, removal of debris upto 1500mtr distance as directed by Engineer-in-charge complete all as specified and as directed.
M&L for brushing neat cement slurry with 3.00 Kg of cement per Sqm complete all as specified and directed.
M&L for 40mm thick PCC (1:2:4) type B-1, using 20mm graded stone aggregate as in roof pedding, sub floor surface finished even & fair without using extra cement complete all as specified and directed.
M & L using ready mix plaster for rendering 10mm thickon roof top surface including WPC by weight of 3% of total cement content complete all as specified and as directed. Note : WPC will be measured separately
M&L for cleaning the new surfaces concrete with wire brushing and applying water proofing treatment as under:- (i) Apply oil bound bitumen primer @ 0.40 Litre/Sqm manufactured by the same agency as that of APP with density of 0.87 to 0.89 Kg/Litre at 25 degree cesius on the pepared dry roof surface. (ii) Laying torch applied APP polymer modified membrane 4mm thick with non-wooven ployster mat as reinforcement weighing n.less than 4.50 Kg/Sqm with white gravel/mineral finished by thermo fusion process all as decribed under particular specification The APP membrane shall be of:- (a) M/s Taxsa India Ltd Mumbai-'MOPLY FP OR (b) M/s Chemical Adhesive (P) Ltd-'Chemistic'OR (c) M/s STP-'Super Thermolay' OR (d) M/s India Ltd, Chennai-'Hyper Plus' or (e) M/s Percept Engrs Pvt Ltd, Kochi-POLYPLUS NOTE: The contractor will be permitted to use materials procured from any one of the manufacturer mentioned above. However , the materials for the entire work shall be of from one manufacturere only.
Complete removal of existing PVC tiles /sheets, of any description in any position including cleaning, wire brushing, watering, removal of debris upto 1500mtr distance complete all as specified and as directed
S&F for PVC tiles /sheets, of 2mm thick laminated plain coloured homogenous, laid with approved rubber based adhesive in floors all as specified and directed.
Removing Chipping ,removing carefully loose and broken concrete by chiselling ,low impact hammer /picking etc upto a depth of 80 mm or of complete loose portion from soffit of slab, column, beams and similar structural members, cutting edges, clearing the dismantled portion with wire brushes etc to remove dust, dirt and other foreign particles etc and washing with clean water with pressure including necessary scaffolding etc,and removal of debris to out of MD land, complete all as specified and as directed.
M&L for Clean existing reinforcement with wire/ rotary wire brush, making the surfaces free from loose material dirt etc. complete and applying two coats of alkaline rust converting primer FEOVERT of Krishna Conchem or Roff rust cleaner of Piddilite or Dr. Fixit Rust removal or ShaliRust of STP Ltd. on the rebars, including cleaning the reinforcement, wirebrushing to remove loose rust spalls, wash the rebars with clean water within 3 min and wipe it dry.
M&L for applying two coats of Epoy based Zinc primer in a span of four hours over the treated rebars and allow to dry for six hours. The application shall be by brush. Epoxy primer for steel of make / brand - Corroseal-ZR of Krishna Conchem or Dr. Fixit Epoxy zinc primer
M&L for cleaning all loose laitance on the concrete substrate and applying one coat of epoxy bonding agent on exposed concrete surface to ensure bond between old concrete & new concrete by brush application. Make / brand Monobond SBR of Krishna Conchem or Dr. Fixit epoxy bonding agent or Shalicrete URP of STP Ltd.
M&L for rendering minimum 20mm to 40 mm thick polymer modified mortar in cemet mortar (1:3) with graded quartz sand with additive Monolith - PMM of Krishnaconchem or polymer mortar HB of Dr. Fixit or Shalifix RM SG 01 of STP Ltd. 15% by weight of cement in one coat with and including curing as per manufacturer's instruction complete all as specified and as directed
M&L for Providing and applying jacketing around columns with Micro concrete (Molith-MC) M40 including all lifts, shuttering, drilling holes and fixing shear anchor as per specification complete.Note: Reinforcement shall be measured and paid separately.(Rates including jacketing, formwork and micro concrete)
M&L for applying concrete protection coating on finished structural members exposed to atmosphere make or brand IPNET of Krishna Conchem or New Coat from Dr. Fixit complete all as specified and directed.
M&L for Drilling and fixing Rohibb Teflon nozzles in RCC members, including drilling holes of 12mm dia, 50 to 100mm deep holes. Works shall be carried out as under :- (i) Cleaning of holes. Clean the holes by air blower prior to fixing nozzles. (ii) Fixing of nozzles. Insert 12mm dia. Rohibb Teflon nozzles in cleaned holes. External end of nozzles to be machine to receive outlet of grouting gun.Fix it inside the holes by applying thixotropic epoxy putty to ensure complete sealing. Cure the system for min.12 hrs. (iii) Cutting of nozzles. Cut the nozzles by chisel after completion of grouting without damaging structural elements. (iv) In case crack upto 2mm wide, fix the injection nozzels directly over the cracks, at intervals of 6 to 9 inches, using a drilling machine. Fix PVC/MS nozzels in these holes with fast-setting epoxy putty & let it dry for 2 to 3 days. Also, seal the crack between the ports with epoxy putty. (v) In case where the crack is wider than 2mm upto 4 to 5mm, drill holes at the sides of the crack in a staggered fashion, at intervals of 6 inches and affix them with epoxy putty as mentioned above. (vi) Also, seal the face of the carck with a liberal application of the epoxy putty.
M&L for Injecting of site mixed cement slurry grout, mixed in specified proportion containing cement, sand water with addition of plasticizers (approved make) & migratory corrosion inhibitors, water cement ratio shall be varied between 0.5 to 1.0 for each hole, shrinkage compensating cement slurry mixed to a lump free fresh creamy consistency ,Mixing shall be done by mechanical mixer continuously stirring mechanically to keep cement particles in suspension. Injection of approved/specified grout by means of pump at a pressure of 3-5 Kg/cm2 etc complete till the grout mix flows out from the nozzle indicating complete filling of grout in the holes drilled. Make / brand of Epoxy grout - Dr. Fixit Epoxy injection or EPCO KP-HP-250 of M/s Krishna Conchem or Shaligrout EI of STP Ltd.
M&L for Injecting low viscosity (3-5cps) high molecular weight monomer by pressure and using mechanized injector gun with accessories till nozzles refuses to accept the grout, Including,Mixing of materialas:Mixing of material components(part a&b) in the required quantities as per manufacturer's instruction by weigh batching.Grouting:Fill the grouting gun with concrete penetrating corrosion inhibitor EPCO-KP-100/Protectsil CIT or Ferogard 903. Maintain desired pressure in the gun by air compressor; maintain the pressureat exit(2 to 3kg/cm2) by monitoring pressure guage at exit.Grout the material through prefixed nozzles in the structural elements@ 100ml per nozzle. Repeat the process for all the nozzles.
Replacement of steel reinforcement with TMT bars of appropriate size where 30% of cross section is reduced including dismantling of rusted steel complete all as specified and directed.
Providing and fixing additional main steel bar or stirrupsof designed diameter in various structural elements like column ,beams and foundations including drilling ,bending and fixing the bars with epoxy putty etc. complete (Steel provided on the basis of 1% of volume of concrete).
M&L for Injecting of site mixed cement slurry grout, mixed in specified proportion containing cement, sand water with addition of plasticizers (approved make) & migratory corrosion inhibitors, water cement ratio shall be varied between 0.5 to 1.0 for each hole, shrinkage compensating cement slurry mixed to a lump free fresh creamy consistency ,Mixing shall be done by mechanical mixer continuously stirring mechanically to keep cement particles in suspension. Injection of approved/specified grout by means of pump at a pressure of 3-5 Kg/cm2 etc complete till the grout mix flows out from the nozzle indicating complete filling of grout in the holes drilled. Make / brand of Epoxy grout - Dr. Fixit Epoxy injection or EPCO KP-HP-250 of M/s Krishna Conchem or Shaligrout EI of STP Ltd.
Dismantling wall and ceiling boards or insulation boards, any thickness, any description, including cover fillets complete. (Note:- Item rate shall be include any height of Bldgs for scafolding as all arrangement.)
S&F Anodised aluminium snap grid of size 600x600 mm frame work for false ceiling complete all as specified and directed by Engr in Charge.
S&F Hangers 6 mm dia GI ( upto 1200 mm length ) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40x3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified and directed.
S&F for PVC False ceiling consisting of 600 mm x 600 mm, 5 mm thick prelaminated self design PVC sheet of density 600 kg/cum solid PVC panel insert in a frame work made using aluminium T section of size (25mm x 25 mm, 19 gauge or 1mm thick) in square pattern of grid size of 600 x 600 mm. The aluminium frame work is supported from the ceiling with the help of GI wire/6 mm MS rods of required size sato maintain for proper level etc. The aluminium frame work is supported on side wall with the use of aluminium 25 mm X 25 mm angles complete as per direction of Engr-in-charge, Manufacturer's specification & drawing.
S&F false ceiling with Armstrong XL 24mm grid system of grid size 600x600mm with 14mm thick ceiling board of RH-90. Grid shall be suspended from ceiling using 4mm dia pre straighten GI wire with 6mm nylon rawl plug & screws at 1200mm intervals complete all as manufacturers instructions and as directed by Engr-in-Charge.
S&F in repair 4 mm thick asbestos cement plain building board fixed to aluminium grid frame work in ceiling all as specified and directed. (Note:- Item rate shall be include any height of Bldgs for scafolding as all arrangement.)
M & L for preparing asbestos & ceiling board surfaces and applying two coats of oil bound distemper over a coat of chalk whitening on plastered surfaces complete all as specified and directed. (Note:- Item rate shall be include any height of Bldgs for scafolding as all arrangement.)
M&L for PCC (1:2:4) type B0 (using 12.5mm graded aggregate) in coping bed black etc including nessesary form work complete all as specified and directed.
M/s S.D Construction Co
Dinesh Enterprises
REALTECH PROJECTS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .