| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹48.8 LAccepted-AOC AZARA THAKURIAPARA AZARA ASSAM 781 017 | KAMRUP METRO | ASSAM | 781017 | L1 | Accepted-AOC Lowest bid | |
| 2 | L2₹51.0 L+₹1.1 L (2.18%)Rejected-Finance VILL KAHIKUCHI PS PO AZARA DIST KAMRUP GUWAHATI ASSAM 781 017 | KAMRUP METRO | ASSAM | 781017 | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹53.0 L+₹3.1 L (6.17%)Rejected-Finance | L3 | Rejected-Finance Other than L1 |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
2 Oct 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) Borjhar
Garrison Engineer (AF) Borjhar, Military Engineer Services, Guwahati Airport- PO, Borjhar Airport, Guwahati, Assam, Pin- 781015 Tele 0361 - 2840127
Repair and Maint of external distribution networks, repair to various equipments and allied works at Mountain Shadow area under GE (AF) Borjhar
2024_MES_671716_1
8425/BOR/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE (AF) Borjhar
MES Contractor enlisted as Class D category b(i) having deposited Standing Security of Rs 50000.00 with dept. Contractors not enlisted in MES should meet the MES enlistment criteria corresponding to appropriate class and category.
8 documents required · 8 mandatory
₹500
Garrison Engineer (AF) Borjhar,
₹96,000
Yes
27 Mar 2025
4 Sept 2024
4 Oct 2024
4 Sept 2024
2 Oct 2024
18 Sept 2024
Amount
Labour for Maintnence and servicing of DG Sets with AMF Panel of following capacities complete all as specified and as dierected (i) Payment for emergency visit for rectifiying deffect and servicing of DG Set shall be measured ,seperately . (ii) Check the under mentioned Qty of DG set from the existing site and preparation of surface by the rust and dust and corrosion by cotton paper /wire brush before repair . (iii) Shifting old u/s spare parts from site to distance not exceed 30 Mtr all as directed. (iv) Cleaning of all dust around the DG Set by using of cleaning materials. (v) Cleaning of all the greasing nozzles /parts by using of emery paper and cotton waste etc. (vi) Carry out the servicing of said DG Set ,Check the oil level of engine oil tupup the same set the tuning of engine if required. (vii) Painting with one coat of existing paint(through spray Gun) should be applied outer side of the engine,writting of Machine No with white paint ,Including of RIM of the said DG Set(Trolly mounted) with black paint and inside of the engine with silver paint with marking of existing Sign should be carried out properly and matching with same. (Cont...)
(viii) Minor spare parts like as rubber gasket , pins, key lock &removing of old engine oil etc shall be replaced under servicing without any extra cost and the proposed rate are excluding consumabale items (Filter, Lube Oil, Coolant) / Component repairing (such as FIP / Self Starter /AC Alternator,s Burning/Battery Charging or Repairing.) shall be measured and paid seperately under respective item of this schedule as supply only and fixing charge shall be deemed included in the unit rate of this of schedule as'each job'. (ix) The repair/ servicing shall be carried out through authorised representative of ORIGINAL EQUIPMENT MANUFACTURER(OEM) only (x) Provide the visual maintenance and service supports to the AC Alternator. (xi) Work site area shall be cleaned properly.and not exceed 30 Mtr all as directed.
DG Set of capacity 125 KVA (with AMF Panel) (Make- Greavs Cotton).(19 Wing Officer Mess, Base Ops, 14 BRD) for emergency visit (DG Set-03 No,s)
DG Set of capacity 25 KVA (with AMF Panel) (Make-Greaves Cotton). (02 ORR and 20 ORR) for emergency visit (DG Set-02 No,s).
All as per Serial Item No. 1.00 here-in-above Labour for Maintenance & Servicing of DG Sets of following capacities complete all as specified and as dierected for servicing of DG Set.
DG Set of capacity 125 KVA (with AMF Panel) (Make-Greavs Cotton). (19 Wing Officer Mess, Base Ops, 14 BRD) for Servicng visit (DG Set-03 Nos)
DG Set of capacity 25 KVA (with AMF Panel) (Make-Greaves Cotton). (02 ORR and 20 ORR) for DG Set-02 Nos)
Supply the following spare parts of DG Set of capacity 03x 125 KVA. required for servicing of DG Set.
FILTER kit (Oil Filter, Diesel filter, Turbo filter and Turbo filter O Ring Kit)
L. O Filter
V Belt
Air Filter primary
Air Filter Secondary
Rotating rectified assembly.
Automatic voltage regulator
Water Pump Assy
Air cleaner hose pipe with clamp.
Radiator hose pipe with clamp.
Safety control valve.
Battery charger for automatic panel.
Supply the following spare parts of DG Set of capacity 2x25 KVA. required for servicing of DG Set.=04 Nos
FILTER kit (Oil Filter, Diesel filter, Turbo filter and Turbo filter O Ring Kit)
L. O Filter
V Belt
Air Filter primary
Air Filter Secondary
Rotating rectified assembly.
Automatic voltage regulator
Water Pump Assy
Air cleaner hose pipe with clamp.
Radiator hose pipe with clamp.
Safety control valve.
Battery charger for automatic panel.
Mahindra
All as per Serial Item No 1.00 here-in-before for Maintenance and emergency visit of DG Sets of following capacities complete all as specified and as dierected for rectified of DG Set.
DG Set of capacity 125 KVA (with AMF Panel) (Make- Mahindra). (19 Wing 59 Sqdn) for emergency visit (DG Set-1 No,s)
DG Set of capacity 63 KVA (with AMF Panel) (Make-Mahidra). (Complain Cell 19 wing) for emergency visit (DG Set-01 No,s).
All as per Serial item No. 1.00 here-in-before, Labour for Maintenance & Servicing of DG Sets of following capacities complete all as specified and as directed for servicing of DG Set.
DG Set of capacity 125 KVA (with AMF Panel) (Make-Mahidra). (19 Wing Officer Mess, Base Ops, 14 BRD) for Servicng visit (DG Set-01 No,s)
DG Set of capacity 63 KVA (with AMF Panel) (Make-Mahidra). (Complain Cell 19 wing) for DG Set-01 Nos)
Supply the following spare parts of DG Set of capacity 1x125 KVA (make -Mahindra). required for servicing of DG Set
FILTER kit (Oil Filter, Diesel filter, Turbo filter and Turbo filter O Ring Kit)
L. O Filter
V Belt
Air Filter Primary
Air Filter Secondary
Rotating rectified assembly.
Automatic voltage regulator
Water Pump Assy
Air cleaner hose pipe with clamp.
Radiator hose pipe with clamp.
Safety control valve.
Battery charger for automatic panel.
Supply and fixing, repairing the following spare parts of DG Set of capacity 63 KVA (Make-Mahindra).
Fuel Filter Secondary
Fuel Filter Primary
L. O Filter
V Belt
Air Filter
R R Assly
Automatic voltage regulator
Water Pump Assy
Air cleaner hose pipe with clamp.
Radiator hose pipe with clamp.
Safety control valve.
Battery charger for automatic panel.
Ashok Leyland
All as per Serial item No. 1.00 here-in-before for Maintenance and emergency visit of DG Sets of following capacities complete all as specified and as dierected for rectified of DG Set.
DG Set of capacity 62.5 KVA (with AMF Panel) (Make- Ashok Layland). (Base ops for IT sec) for emergency visit (DG Set-1 No,s)
All as per Serial item No. 1.00 here-in-before, Labour for Maintenance & Servicing of DG Sets of following capacities complete all as specified and as dierected for servicing of DG Set.
DG Set of capacity 62.5 KVA (with AMF Panel) (Make- Ashok Layland). (Base ops for IT sec) for Servicng visit (DG Set-01 No,s)
Supply the following spare parts of DG Set of capacity 1x 62.5/63 KVA. required for servicing of DG Set
Oil Filter F7A05000
Oil Filter F7A05000
Fuel Stainer
Fan belt X0301750
Jakson(Cummins)
All as per Serial item No. 1.00 here-in-before for Maintenance and emergency visit of DG Sets of following capacities complete all as specified and as dierected for rectified of DG Set.
DG Set of capacity 45 KVA (with AMF Panel) (Make- Jakson (Cumins). (C Cell, Education Sec 19 wing) for emergency visit (DG Set-1 No,s)
DG Set of capacity 62.5KVA (with AMF Panel) (Make- Jakson (Cumins). (C Cell CD Upadhayay Block 19 Wing 59 Sqdn) for emergency visit (DG Set-1 No,s)
All as per Item No (1) above, Labour for Maintenance & Servicing of DG Sets of following capacities complete all as specified and as dierected for servicing of DG Set.
DG Set of capacity 45 KVA (with AMF Panel) (Make- Jakson (Cummins).(C Cell, Education Sec 19 wing) for Servicng visit (DG Set-01 No,s)
DG Set of capacity 62.5KVA (with AMF Panel) (Make- Jakson(Cummins). (C Cell CD Upadhayay Block 19 Wing) for Servicng visit (DG Set-01 No,s)
Supply the following spare parts of DG Set of capacity 1x 62.5 & 1x45 KVA.required for servicing of DG Set
Lube Oil Filter
FILTER kit (Oil Filter, Diesel filter, Turbo filter and Turbo filter O Ring Kit)
V Belt
Air Filter (Inner & Outer)
R R Assy
Water Pump
Supply and fixing for engine stop solenoid switch for DG set of capacity 45/25 KVA as per existing make for DG Set - Greavs Cotton/Jackson
Supply and fixing for engine stop solenoid switch for DG set of capacity 125/63 KVA as per existing make for DG Set - Greavs Cotton/Mahindra/Ashok Lay land/Jackson
Supply only engine oil 20W 40 for diesel engine driven generator in 50 ltrs container . Make : KOEL (Type- Premium)/ Eqvt to Castrol/ Indian Oil
Supply only coolant for diesel engine driven generator in 26 ltrs container . Make : KOEL (Type- K-Cool)/ Eqvt.
Supply only distilled water for diesel engine driven generator.
Supply and fixing for battery of Capacity 12V 130 AH Complete all as specified and as directed. Make: Exide New Express Cat Part No-FXPO-MHD-1800 Or equivalent
Supply and fixing for battery of Capacity 12V 150 AH Complete all as specified and as directed. Make: Exide New Express Cat Part No-FXPO-MHD-1200 Or equivalent
S & F for battery lead with terminal cable of copper conductor size 19 SWG and 90 CM long as in repair complete all as specified and as directed by Engineer -in- Charge
Suplly and fixing for Alternator fly wheel ring gear for DG set capacity 125/63 as per existing make .
Supply only power contactor 4 pole for 125/63/45/25 KVA DGSet (any Make fo DG set) AMF Panel Make: L&T /Suchnieder/Seimens
Supply and fixing for turbo charger repair kit for DG set of capacity 125/63 KVA as per existing make for DG Set - Greaves Cotton /Mahindra /Jakson /Ashok Layland.
Supply and fixing for turbo charger repair kit for DG set of capacity 45/25 KVA as per existing make for DG Set - Jakson /Greaves Cotton.
SELF STARTER REPAIR
Taking out /Removing of unserviceable Self starter assembly complete for repairing to workshop replacing armature, winding with size copper enamelled wire, repair /servicing of commutator, replacing of corbon brush, complete servicing, greasing including re-assembling, re-fixing (testing, commissioning complete all as specified and directed including replacing of small worm out parts) of DG set of capacitty 125/63 KVA Make : Greaves Cotton /Mahindra/Jakson/Ashok Leyland
Taking out /Removing of u/s Self starter assembly complete for repairing to workshop replacing armature, winding with size copper enamelled wire, repair /servicing of commutator, replacing of corbon brush, complete servicing , greasing including re-assembling, re-fixing (testing, commissioning complete all as specified and directed including replacing of small worm out parts) of DG set of capacitty 45/25 KVA Make : Greaves Cotton/Jakson
DYNAMO REPAIR
Taking out /Removing of u/s Dynamo assembly complete for repairing to workshop rewinding of armature with same size copper enamelled wire complete servicing of commutator, replacing roter complete, re-assembliing testing commissioning complete all directed. of DG set of capacitty 125/63 KVA (Make -Greaves Cotton/Mahindra /Jakson/Ashok Leyland)
Taking out /Removing of u/s Dynamo assembly complete for repairing to workshop rewinding of armature with same size copper enamelled wire complete servicing of commutator, replacing roter complete, re-assembliing testing commissioning complete all directed. of DG set of capacitty 45/25 KVA (Make -Jakson/Greaves Cotton)
Supply & Installation PCB controller of AMF panel of DG Set as per existing make & type including taking down old unsv one all as specified and directed.
M&L for repairing of FIP for 25 to 45 KVA DG Set through FIP repair kit, incl replacement of valve and element (where ever reqd) and calibration all as specified and directed. Make of DG Set- Greaves Cotton/ Mahindra/ Cummins/Jakson
M&L for repairing of FIP for 62.5/ 63/ 100/ 125 KVA DG Set through FIP repair kit, incl replacement of valve and element (where ever reqd) and calibration all as specified and directed. Make of DG Set- Mahindra/ Cummins/Greaves Cotton/Jakson/Ashok Layland
S&F Self Starter Complete set 12 V for 25-45 KVA Kirloskar/ Kirloskar Bliss/Mahindra/ Cummins make Gen Set incl replacement of cable of suitable size complete all as specified and directed.
S&F Self Starter Complete set 12 V for 63-125 KVA Kirloskar/ Kirloskar Bliss/Mahindra/ Cummins make Gen Set incl replacement of cable of suitable size complete all as specified and directed.
M&L for dismantling the radiator assembly incl hose/ pipe/ clamps etc after shut off the diesel generator set of 25 to 45 KVA capacity and taking out the same at workshop and cleaning/ servicing the same by following process:- a) Spray the hot water or steam to remove dirt, dust or even insects which are accumulated in the radiator. b) Descaling the radiator by using rust removing acid solution and water or mixture of water, caustic soda and kerosene as per the recommendation of the manufacturer of the generator set c) Transportation to the installation, reconnection, testing & checking etc complete Note: Repairing such as brazing or soldering, replacement of tank, hoses pipe, clamps etc are deemed to be included in the quoated rate.
M&L for dismantling the radiator assembly incl hose/ pipe/ clamps etc after shut off the diesel genrator set of 63 to 125 KVA capacity and taking out the same at workshop and cleaning/ servicing the same by following process:- a) Spray the hot water or steam to remove dirt, dust, or even insects which are accumulated in the radiator. b) Descaling the radiator by using rust removing acid solution and water or mixture of water, caustic soda, and kerosene as per the recommendation of the manufacturer of the generator set c) Transportation to the installation, reconnection, testing & checking etc complete Note:-Rrepairing such as brazing or soldering, replacement of tank , hoses pipe, clamps etc are deemed to be included in the quoated rate.
Supply and fixing for turbo charger repair kit for DG set of capacity 125/63 KVA as per existing make and cat No (For any Make of DG Set- KOEL/Kirloskar Bliss).
Supply and fixing for turbo charger repair kit for DG set of capacity 45/25 KVA as per existing make and cat No (For any Make of DG Set- Kirloskar/ Kirloskar Bliss/Mahindra/ Cummins).
S& F of Flexible pipe for fuel pump to PT pump with benjo nut , bolt & washer for Dg Set of capacity up to 125 KVA
S & F of Flexible pipe for disel tank to filter with benjo nut, bolt & washer for Dg Set of capacity up to 125 KVA
Labour for Dismantling/strip opening of 45 KVA DG Set Make-Kirloskar Bliss (at Mountain Shadow P H No-02) for repairing/ovehauliing complete, re-fixing /reassembling complete including testing commissioning all as directed. Note: (a) The above repair/overhaul shall be carried out through authorised representative of OEM. (b) The spare parts required for repairing /overhaulling shall be measured and paid under relevant items.
Supply only under mentions item for required against item Sr No 53. (Overhaulling of 45 KVA DG Set Make- Kirloskar Bliss)
Piston Assembly
Piston Pin
Piston Circlip
Piston Ring
Cylinder Liner
Con. Rod Bearing
Head Gasket
Rocker Cover Gasket
Cooling Nozzle
Valve Inlet & Exh. Pair
Valve Seat
Valve Seal
Valve Guide
Valve Collet
Fuel Pipe (1.5 Mtr)
Fuel Pipe 3 Feet
Fuel Pipe 2.5 Feet
Radiator hose .
Hose Clamp
Banjo Bolt
Copper Washer
Filter Kit
Air Filter
Liner O ring
Set Of Gasket
Anabond (Big)
Oil Seal (Fornt )
Oil Seal (Rear)
Thrust Bearing
Main Bearing
Cam Bush
Small End Bush
Leak Of Pipe
H. P. Pipe Set
Water Pump
Starter Ring
Self Starter 12V
Charging Alternator 12V
L.O. Supply Hose (FIP)
L.O.P. Sensor
Stop Solenoid
L.O Cooler
L.O Cooler Pipe
Feed Pump
Lube Oil Pump
Expansion Bellow
Banjo Bolt 10 No
FIP & Nozzlel Re-Calibration with spares
Radiator Servicing & Cleaning
Crank shaft Granding & Polising, Main Bearing Setting
Cylinder hard Repairing & Valve Grinding
T.C Repairing with service kit
Con Rod Assembly checking & S.E Bush fitting
Silencer Assembly Repairing
Excavating in trenches manually not exceeding 1.5m wide and not exceeding 1.5 mtr in depth/ width for laying under ground cable / foundations and getting out in soft / loose soil all as specified and directed. Note: During excavation no mechanical excavator is permitted at site, contractor will do the excavation through manually.
Returning, filling in incl spreading, levelling, watering and well ramming in layers not exceeding 25cm all as specified and directed.
Removing of surplus excavating material not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point all as specified and directed.
M&L for sand cushioning for protection of lT under ground cable with screen wash sand and punning to proper reqd cover all as specified and directed.
M & L brick protection with old size sub class ‘B’ brick for PVC under ground cable protection in trench with width equal to length of brick laid dry and flat joining each other with gap between adjacent brick not exceeding 10mm over LT under ground cable all as specified and directed.
M&L for cement concrete in foundations, filling and mass concreteType C2 1:3:6, 40mm graded aggregate all as specified and directed.
M&L for PCC as in foundation or any other works type B1 (1:2:4) (20mm graded aggregate) all as specified and directed. Note: Any form work required for PCC works are deemed to be included in this rate.
M&L rendering 10mm thick in CM 1:6 on fair faces of brick works or concrete surfaces all as specified and directed.
M&L for taking out of old/ unsv cable of any sizes or types for replacement with new one complete all as specified & directed.
M&L for relaying heavy duty LT under ground cable of any sizes and types in pipe /trench /cable duct /fixed on wall by proper size shaped GI clamps with nut bolts etc and making good the disturbed surfaces by cement mortar/paint to match with the existing surface complete all as specified & directed.
M&L for LT Cable fault detection and its rectification by using Cable fault locator machine of span length maximum 2km of cable size 95 to 400 sqmm all as specified and and directed by Engr-in-Charge. Note: Suitable excavation and jointing kit will be measured and paid seperately.
S&L in repair of UG cable XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 Volts grade, cross section area incl taking down of size 185 Sqmm 3.5 core complete all as directed. Note : On ground Factory test to be carried out by the rep of MES and the contractor at manufacturer's godown / factory / testing lab situated at OEM's premises in front of OEM's technician / lab engineer and results shall be recorded duly signed by Engr-in-Charge, contractor and the technician / lab engineer. The material shall only be incorporated after getting satisfactory results and the rates quoted is deemed to be included for the above and no extra claim shall be admissible on this account. The test reports with satisfactory results duly signed shall be forwarded alongwith RAR failing which no payment shall be admissible against this item.
All as per Serial item No. 190.00 here-in-before but size 150 sqmm 3.5 core complete all as directed.
All as per Serial item No. 190.00 here-in-before but size 95 sqmm 3.5 core complete all as directed.
All as per Serial item No. 190.00 here-in-before but size 70 sqmm 3.5 core complete all as directed.
All as per Serial item No. 190.00 here-in-before but size 50 sqmm 3.5 core complete all as directed.
All as per Serial item No. 190.00 here-in-before but size 25 sqmm 3.5 core complete all as directed.
All as per Serial item No. 190.00 here-in-before but size 16 sqmm 4 core complete all as directed.
All as per Serial item No. 190.00 here-in-before but size 10 sqmm 2 core complete all as directed.
M&L for boring under roads or any other specified location by reqd T&P without disturbing the top surface of the road for insertion of GI Pipe of 50 to 100 mm dia etc complete all as specified and directed.
M&L for HDPE Double wall corrugated pipe of size 110/95 mm as per IS: 16098 Part-II-2013 and ISO 21138 & BSEN 13476-1TO 3 laid in trenches/wall for protection cables complete all as specified and directed.
M&L for tubes 50 mm bore light grade galvanized with all fittings laid in trenches/ wall/ pole through MS flat (25X3 mm), nut, bolt & washers [where ever reqd] of proper sizes for protection cables complete all as specified and directed.
All as per Serial item No. 200.00 here-in-before but bore size 40 mm complete all as directed.
M&L for replacement of cable duct cover or any other works made up of chequered plate of thickness 8mm with lifting handle (whereever reqd) including fabrication works such as cutting, welding & bent to shape and painting with two coats of black japan paint over a coat of red oxide primer on steel surfaces of any description over 10cm in width or girth including preparation of new untreated surfaces complete all as specified and directed.
M&L angle iron / flat bar of required sizes with locking arrangements including fabrication works such as such as cutting, welding & bent to shape and painting with two coats of black japan paint over a coat of red oxide primer on steel surfaces of any description over 10cm in width or girth including preparation of new untreated surfaces complete all as specified and directed.
M&L for fixing the aluminium terminal (Cable Lugs) in cable end (through corrosion inhibiting compound) of cable size 185 sqmm all as specified & directed. Note: Corrosion inhibiting compound which will be used during crimping of terminal shall be measured and paid separately.
All as per Serial item No. 204.00 here-in-before but for cable size 150 sqmm all as specified and directed.
All as per Serial item No. 204.00 here-in-before but for cable size 95 sqmm all as specified and directed.
All as per Serial item No. 204.00 here-in-before but for cable size 70 sqmm all as specified and directed.
All as per Serial item No. 204.00 here-in-before but for cable size 50 sqmm all as specified and directed.
All as per Serial item No. 204.00 here-in-before but for cable size 35 sqmm all as specified and directed.
All as per Serial item No. 204.00 here-in-before but for cable size 25 sqmm all as specified and directed.
All as per Serial item No. 204.00 here-in-before but for cable size 16 sqmm all as specified and directed.
All as per Serial item No. 204.00 here-in-before but for cable size 10 sqmm all as specified and directed.
M&L for triming the tree branches falling / touching the HT/LT overhead line in various area of AF Station Borjhar with skilled labours and cutting tools and disposed the branches to a distance not exceeding 50 mtr length complete all as specified and directed.
M&L for replacement of damage/ corroded hinges with new hinges through necessary gas / arc welding works complete on the outdoor feeder pillar box/ LT panel or any other works complete all as specified and directed.
M &L for replacement of corroded sheet metal doors of outdoor/ inddor feeder pillar box or LT panel with new CRCA sheet of 2 or 3mm thick incl painting the same with two coats of enamel paint of existing shade over a coat of red oxide primer complete incl treatment of new surfaces complete all as specified and directed.
M&L for writing letter, figures, index arrows etc not exc 30 cm in height on LT Panel or any other specified location complete all as specified and directed.
M&L for painting of LT Feeder Pillar Box/ Panel Board or any other plant or equipments by two coats of enamel paint of existing shade after treating old painted surfaces complete al as specified and directed.
M&L for cable jointing kit for 1.1KV grade for outdoor end termination heat shrink type joint complete with jointing material and accessories suitable for 4 core PVC/ XLPE armoured aluminium conductor cable of size 25 - 50 sqmm complete all as specified and directed. Make : 3M/ Raychem
All as per Serial item No. 218.00 here-in-before but size 70-150 sqmm all as specified and directed.
All as per Serial item No. 218.00 here-in-before but size 185-300 sqmm all as specified and directed.
M&L for cable jointing kit for 1.1KV grade for outdoor straight through heat shrink type joint complete with jointing material and accessories suitable for 4 core PVC/ XLPE armoured aluminium conductor cable of size 70-150 sqmm complete all as specified and directed. Make : 3M/ Raychem
All as per Serial item No. 221.00 here-in-before but size 185-240 sqmm all as specified and directed.
S&F On-Load Manual Change Over Switch (in sheet steel enclosure) 63 Amps 415 Volts, 4 pole after disconnecting all electrical connection including taking down old unserviceable one complete all as specified and directed. Make : L&T/ Siemens/ABB = 01 No
All as per Serial item No. 223.00 here-in-before but capacity 100 Amp all as specified and directed.
All as per Serial item No. 223.00 here-in-before but capacity 160 Amp all as specified and directed.
S&F moulded case circuit breaker 80 - 100 Amps 415 Volts (with thermal magnetic release), 4 pole 25 KA breaking capacity, Ics=100% Icu, adjustable overload settings 0.8 - 1.0 x In, adjustable short circuit settings 6 - 10 x In after disconnecting all electrical connection incl. taking down old unsv one complete all as specified and directed. Make : L&T/ Siemens/ABB = 01 No
S&F moulded case circuit breaker 125 - 160 Amps 415 Volts (with thermal magnetic release), 4 pole 25 KA breaking capacity, Ics=100% Icu, adjustable overload settings 0.8 - 1.0 x In, adjustable short circuit settings 6 - 10 x In after disconnecting all electrical connection incl. taking down old unsv one complete all as specified and directed. Make : L&T/ Siemens/ABB = 01 No
S&F moulded case circuit breaker 200 - 250 Amps 415 Volts (with thermal magnetic release), 4 pole 25 KA breaking capacity, Ics=100% Icu, adjustable overload settings 0.8 - 1.0 x In, adjustable short circuit settings 6 - 10 x In after disconnecting all electrical connection incl. taking down old unsv one complete all as specified and directed. Make : L&T/ Siemens/ABB = 01 No
M&L steel tubular swaged pole 9 mtr long complete with MS base plate, finial taper plug nut bolts, screws as specified type 410SP-31 as per relevant IS specification including two coats of aluminium paint over a coat of red oxide primer including taking down old unserviceable and removing from site complete all as directed by Engr-in-charge (earth work/excavation PCC shall be measured and paid separately under relevant item of schedule).
M&L for fixing the cable junction boxes of size 155 x 210 x 92 mm, with PVC connector 4 way heavy duty for 10 - 16 sq mm, 4.0 /3.5 C, 1100V cable, IP 66/65, weather proof, outdoor installation type with threaded cable glands & pole mounting brackets etc complete all as specified & directed. Make : Hensel / OBO
M &L 2.5 Sqmm, 3 Core Black PVC Insulated Single solid Aluminium conductor round service cable 1100V for connection from loop /junction box to street light / security light complete all as specified and directed.
M&L for tubes 15 mm bore light grade galvanized with all fittings laid in trenches/ wall/ pole through MS flat (25X3 mm), nut, bolt & washers [ where ever reqd ] of proper sizes for protection cables complete all as specified and directed.
M&L for Earthing complete with copper earth plate electrode of size 600x600x3.15 mm thick buried directly in ground with earth pit not less than 2.25 meter deep below ground level with top edge of plate not less than 1.5 meter below normal ground level connected to 20×3mm copper strip as earth lead by means of nuts, bolts, check nuts, washers of galvanized iron as steel, protected by galvanized iron pipe 40mm bore (Medium grade) all as directed including cement concrete (1:3:6) type C-1 earth pit with precast RCC (1:1.5:3) type A-1 cover slab of size 42 x 42 x10cm thick reinforced with 8mm dia TMT bars @ 15 cm c/c both ways with 10mm dia mild steel round bar of 30 cm long, bent to shape as lifting handle, funnel, wire mesh, 20 mm bore galvanized iron pipe (medium grade) for watering, earth testing point, charcoal or coke and salt in alternate layers with necessary earth work in soft/loose soil complete all as shown in electrical plate No 3 of SSR Part I including testing on completion all complete as specified and directed. (copper strip upto 7.5m including testing consider in this item).
M&L for Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw.
M&L for Copper strip 20 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground.
M&L for Earthing complete with galvanised steel earth plate electrode 60 cm x 60cmx6mm thick buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 meters below normal ground level. connecting to the Galvanised iron earth wire 4.0mm dia by means of bolls, nuts, check nuts and washers of galvanised iron and earth wire protected by provision of GI medium grade pipe 15mm bore including provision of concrete pit in PCC (1:2:4) type B-1 using 20mm graded stone agregates with 40mm thick cover of RCC (1:2:4) reinforeed with XPM weight not less than 4 Kg/Sqm) and frame of angle iron 40x40x6mm with lugs 02 Nos and handle of 6mm dia MS bar made to shape, GI light grade 20mm bore pipe for watering , perforated at botytom. 1.75 metre long placed on top edge of earth plate. charcoal and common salt filled 150 mm thick all around the earth plate test point made out of 40x8mm FI galvanised with fixing arraangement, funnel wire mesh and earth work in any type of soil returing filling in and removal of surplus soil to a distance not exceeding 50 meters all as per electical plate 3 of SSR-2009 Part-I and connecting to earth test point all as specified or indicated including testing on completion.
S&F, including fabrication installation of glow sign board made out of ACP sheet of size 4'x3' fitted with the help of supporting clamps/nuts& blots fitted to stainless steel tubing 50 mm dia light grade, all around the ACP Sheet. Name of the installation/Location to be written on both side of the ACP Sheet with stenciles of good quality. The height of the board will be 4' from ground level to bottom of ACP Sheet and 1.5' for fixing below ground level (so the total height is 3'+4'+1.5'=8.5') with and inclusive necessary excavation/PCC all as directed by Engr-in-Charge. (Sample board is available with AGE E/M Office). Note: Approval of each sign board shall be taken by the contractor before fabrication.
M&L for Writing of MES/SM No on installed equipment/ Machinery with the help of enamel paint of light gray background with letter on white colour. Approx size of letter is 40 mm complete all as specified and directed by Engr-in-Charge.
M&L for fabrication of ACP Sheet 3mm thick of size 1.5'x 2' for writing with stencils such as history of machines, manufacturers name, Srl No, Date of installation, SM No/ MES No/ Machine No all as directed by Engr-in-Charge. Note : For each board, specimen shall be provided by MES Executive duly approved by Engr-in-Charge.
Supply and fix in repairs and testing, commissioning for indication lamps with showing red, yellow and green in colour of 22.5mm dia to monitor on panel board suitable for 240V AC supply as existing at site,as specified and directed.
S & F energy saving LED spike light of IP66 using COB LED of capacity 8/9 W. Make : Havells/Wipro/Philips or equivalent make specified in CA.
M&L for HDPE Double wall corrugated pipe of size 63/50 mm as per IS: 16098 Part-II-2013 and ISO 21138 & BSEN 13476-1TO 3 laid in trenches/wall for protection cables complete all as specified and directed.
S&F Double wall corrugated pipe coupler for pipe size 63/50 mm all as directed by Engr-in-Charge.
S&F Double wall corrugated pipe coupler for pipe size 110/95 mm all as directed by Engr-in-Charge.
R. D. ENTERPRISE (BID ID -3124939)
M/s Bikash Das (BID ID -3124729)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .