Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Accepted-Technical 39 BHUVANESHVARI VATIKA VISTAR MEENAWALA PANCHYAWALA SIRSI ROAD MEENAWALA PANCHYAWALA SIRSI ROAD JAIPUR RAJASTHAN 302034 | JAIPUR | RAJASTHAN | 302034 | Accepted-Technical Qualified |
| 2 | Accepted-Technical G 41 GROUND FLOOR AMBER TOWER SC ROAD JAIPUR | JAIPUR | JAIPUR | RAJASTHAN | Accepted-Technical Qualified |
| 3 | Accepted-Technical | Accepted-Technical Qualified |
Tender Value
₹1.9 Cr
EMD Value
₹3.7 L
Closing Date
12 Oct 2026, 2:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
UNIT HEAD ABUROAD
Unit Office ABuroad
Providing and laying of Power line at I/A Chadual, Abu Road.
2026_RIICO_601258_1
2026-27/Abu Road/04
Open Tender
Electrical Works
Percentage
365 days
Industrial Area Chadual
Please refer Tender documents.
3 documents required · 3 mandatory
₹5,900
RIICO ABUROAD
₹3.7 L
19 Oct 2026
29 Sept 2026
13 Oct 2026
29 Sept 2026
12 Oct 2026
29 Sept 2026
90 days
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply and erection of P.C.C. pole as per REC manual no 15/1979 (ammended upto date) and as per latest Discom specifications with factor of safety 2.5 including excavation of pit upto pole planting depth 1/6th of pole length. and back filling with stone aggregate/boulders and soil by ramming and watering etc complete as required. All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure 'A' attached with this BSR, 9.0 Mtr long PCC pole of 400 Kg Working Load | 294 | Each | 5,918 | ₹17,39,892 |
| 2 | Supply and erection of GI stay set confirming to pattern-1 of BS:16/1974 and as per latest Discom Specifications complete with stay rod with anchor plate fitted with cast iron cross head and steel bow, in cement concrete 1:3:6 including excavation of pit-re-filling etc complete as reqd. All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure 'A' attached with this BSR, Stay set of dia 20mm, 2.4m long stay rod and anchor plate 380 x 380 x 4.0 mm | 60 | Each | 1,358 | ₹81,480 |
| 3 | Supplying and drawing overhead steel core Aluminium conductor (ACSR) ISI marked(IS 398 part II-1996) on existing cross arms through insulator with all necessary T&P required including binding and twisting etc. complete in all respect as required. All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure 'A' attached with this BSR, 100 sqmm of (6/4.72 mm+1/1.57 mm) (Dog) | 20,627 | mtr. | 117 | ₹24,13,359 |
| 4 | Supply and fixing of V type cross arms with top hamper and clamps as per latest Discom specifications made of MS angle on the existing poles complete including all necessary nut and bolt, clamps with two coats of Red oxide and two coats of Aluminium paint etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure A attached with this BSR | 239 | Each | 1,417 | ₹3,38,663 |
| 5 | Supply and fixing of MS. Channel Bracket with clamp as per Discom Specifications including Nut, Bolt with two coats of Red oxide and two coats of Aluminium paint etc. as Required. All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure 'A' attached with this BSR, 1.4 Mtr. Long | 90 | Each | 1,676 | ₹1,50,840 |
| 6 | Supply and fixing of 11 kV pin insulator confirming to IS:731:1971 with latest ammendment on existing bracket including all accessories like MS forged hot dipped GI Pin confirming to IS 2486(Part-I)/1993 & IS:2486 (Part-II)/1989 with latest amendment, and as per latest Discom specs. etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure 'A' attached with this BSR | 1,070 | Each | 175 | ₹1,87,250 |
| 7 | Supply and fixing of 11kV Disc insulator and Hot dipped galvanized Hardware confirming to IS:731:1971 with latest ammendment and as per latest Discom Specs. on existing bracket including all accessories etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure 'A' attached with this BSR, B & S type hardware 45 KN | 135 | Each | 640 | ₹86,400 |
| 8 | Supply and fixing of 11kV Disc insulator and Hot dipped galvanized Hardware confirming to IS:731:1971 with latest ammendment and as per latest Discom Specs. on existing bracket including all accessories etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure 'A' attached with this BSR, B & S disc insulator 45 KN | 270 | Each | 374 | ₹1,00,980 |
| 9 | Supply and fixing of 100 Amp, 11kV Horn gap fuse set IS 9385 on existing DP structure with 6 nos 24kV/22kV post insulator (IS:5350 part III), hot dipped hard ware,fuse wire of required size etc. complete in all respect as per Discom specification etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . | 109 | Each | 9,071 | ₹9,88,739 |
| 10 | Supply and fixing of 11kV, 400 Amp 3 pole, central pot rotating double break type isolator (IS:9921 part I toV) without earth blade operating mechanism with GI spring loaded reverse loop type fixed contact, solid hard drawn electolytic copper tubular moving contact with silver/ nickel plated at end points, 9 nos post insulator of 12 kV (IS:2554 & IS 5350 part III), hot dipped galvanising hard ware, nut, bolts etc complete in all respect as per Discom specification etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . | 109 | Each | 22,632 | ₹24,66,888 |
stage.html
html • 0.02 MB
tech_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.36 MB
SpecialtermandconditionSLPL.pdf
Other Document • 0.41 MB
TenderdocumentsPLCH.pdf
Tender Documents • 0.20 MB
BOQ_1065809.xls
BOQ • 0.56 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .