| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹41.3 LAccepted-AOC NO 1A 1 SHALOM VALLUVAR STREET SIVANANDHA COLONY COIMBATORE TAMIL NADU 641 012 | COIMBATORE | TAMIL NADU | 641012 | ₹41.3 L | L1 | Accepted-AOC BEING L1 |
| 2 | L2₹44.1 L+₹2.8 L (6.82%)Rejected-Finance THE JEHOVAH SHALOM 21 THIRUMALAISAMY STREET LAKSHMI NAGAR EXTN KAVUNDAMPALAYAM COIMBATORE 641030 | COIMBATORE | COIMBATORE | TAMIL NADU | 641030 | ₹44.1 L+₹2.8 L (6.82%) | L2 | Rejected-Finance BEING NOT LOWEST TENDER |
| 3 | L3₹48.1 L+₹6.9 L (16.7%)Rejected-Finance 25 A RR SAMY LANE KATTOOR COIMBATORE 641009 | COIMBATORE | COIMBATORE | TAMIL NADU | 641009 | ₹48.1 L+₹6.9 L (16.7%) | L3 | Rejected-Finance BEING NOT LOWEST TENDER |
| 4 | L4₹48.4 L+₹7.2 L (17.4%)Rejected-Finance | ₹48.4 L+₹7.2 L (17.4%) | L4 | Rejected-Finance BEING NOT LOWEST TENDER |
| 5 | L5₹48.8 L+₹7.6 L (18.3%)Rejected-Finance | ₹48.8 L+₹7.6 L (18.3%) | L5 | Rejected-Finance BEING NOT LOWEST TENDER |
Tender Value
Refer Docs
EMD Value
₹96,000
Closing Date
27 Apr 2021, 6:00 pmClosed
GE AF SULUR
Garrison Engineer AF Sulur Military Engineer Services Kangayampalayam Post Sulur Coimbatore 641 401
REPAIR MAINT OF CEILING FANS EXHAUST FANS WALL MOUNTED FANS PEDESTAL FANS AIR CIRCULATORS AND CERTAIN MISC E AND M WKS AT AFS SULUR
2021_MES_434942_1
8389/E8
Open Tender
Miscellaneous Works
Item Rate
303 days
GE AF SULUR
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
Yes
GE AF SULUR
₹96,000
Yes
31 May 2021
7 Apr 2021
28 Apr 2021
7 Apr 2021
27 Apr 2021
21 Apr 2021
7 Apr 2021 - 20 Apr 2021
Amount
SCHEDULE A BOQ
M&L for taking down of ceiling fan of size 1200/1400mm for safety checking by replacing defective parts/painting/rewinding and re-fixing the ceiling fan after repairs,all as specified and as directed by Engr-in-charge. (Note:- The replacement of unserviceable items like capacitor, Bearings, Bush, Canopy, down rod etc.shall be made as directed by the Engineer-in-Charge which will be measured and paid separately under respective items as Supply only. However, parts of minor nature such as screws, lugs, insulation tape, nuts, bolts, washers etc after cleaning the metal surface, greasing/lubricant etc to make it functional and making connection by replacing PVC insulated unsheathed cable of copper conduct of size 1.5 Sqmm from ceiling rose/ connector fan (minimum 0.50 Mtr length) including cost of labour for above replacement are deemed to be inclusive in quoted rate all as directed.
Note for item No 2 : The following items shall be deemed to be inclusive in the unit rate quoted against Sl Item No 2:- (a) In each job, checking the functioning of fan including its connections, cleaning of fan, greasing of fan and mechanical check i.e. tightening of loose screw, nuts, bolts, etc are inclusive in unit quoted rate.
(b) The above job shall be carried out by a trained electrician having qualified in ITI ( electrician Trade), documentary proof of the education of tradesman shall be produced, before commencement of work.
(c) Replacement of unserviceable parts like rubber bush, clamps, bolts, nuts, washers, safety pin, bearing etc will be paid under respective item here-in-after as supply only through proper documentation.
(d) The entire job will be carried out in Air Force stn Sulur and necessary documents showing qtr No, bldg No supported with user signature shall be prepared as per format directed by Engr-in-charge and will be deposited to concerned JE (E/M) within 24 hrs.
(e) Maitenance of documents ie complaint slip/complaint register & other stationery required shall be of contractor's responsibility.
(f) Necessary T&P such as ladder, required manpower for taking down and refixing after repair shall be of contractor's responsibility.
(g) All types of T&P, PVC insulation tape, minor nuts, bolts, washers etc required for maintaining the services shall be provided by contractor without any cost to the department.
(h) Any fan found defective/not working shall be brought to AGE E/M store yard & re-fixed after repairing.
(j) In case of major defects, entire job shall be completed within 10 days from the date of registration of complaint, failing which penalty charges @100/- per day shall be recovered.
(k) In case of minor defects, entire job shall be completed within12 hrs from the time of registration of complaint, failing which penalty charges @ 50/- per job shall be recovered.
(l) The contractor shall maintain a record of all urgent/ routine works and if the work is repeated due to poor workmanship, he will be liable to repair the same without any extra expenditure to the Govt.
Supply only rotor of ceiling fan of any size
Supply only fan canopies for ceiling fan size of 1200mm/1400mm
Supply only gun metal bush of suitable size for ceiling fan 1200mm /1400 mm sweep
Supply only fan bearing suitable for ceiling fan 1200mm /1400 mm sweep (bearing with 8 balls shall be used ) Make:- NBC/TATA/SKF
Supply only down rod for ceiling fan with 15mm dia (of length not less than 45cm and not more than 60cm) with hanging clamps for ceiling fan complete all as specified and directed.
Supply only Rubber reel bushes for ceiling fan of size 1200/1400mm
Supply only 'U' clamp for hanging ceiling fan with all nuts, bolts and washers.
Supply only outer body of ceiling fan of any size
Supply only blades (made of aluminum) suitable for 1400mm sweep ceiling fan of any make with set of screws complete all as specified and directed.
Supply only safety pins 40mm to 50mm long with nuts and bolt with washers for ceiling fan of size 1200/1400mm
Supply only steel screw (for fixing of fan blade) as per site requirement for any make of ceiling fan complete all as specified and directed.
Supply only blades (made of aluminum) suitable for 1200mm sweep ceiling fan of any make with set of screws complete all as specified and directed .
Supply only down rod for ceiling fan with 15mm dia (of length not less than 90cm and not more than 120cm) with hanging clamps for ceiling fan complete all as specified and directed.
Supply only down rod for ceiling fan with 15mm dia (of length not less than 180cm and not more than 210cm) with hanging clamps for ceiling fan complete all as specified and directed.
M&L painting the ceiling fan 1200mm /1400 mm sweep with one coat of syntetic enamel paint as existing colour and writing the MES No- as directed by Engr in Charge.(taking down of fan,and re hanging measured under item No. 2 seperately. Note:- Painting of ceiling fan shall be done inside MES complex only.
Material and labour for winding of ceiling fan motor 1200 mm sweep of any make with super enameled copper winding wire of existing gauge (wt of copper winding wire per fan 350 to 500 gms) including cutting and getting out old burnt winding, sleeve work, varnishing with E class insulation varnish, threading, connections with twin core copper flexible wire of size 0.0076mm of length not more than one meter with each fan complete all as specified and directed. Note :- (i) Motor shall be wound with machine inside MES complex only. (ii) Old burnt wire shall be contractor’s property and necessary credit shall be recovered as per credit shedule. (iii)taking down of fan,and re hanging measured under item No. 2 seperately.
Description all as per Sl item No 29 here in above but ceiling fan of 1400 mm sweep
Supply and fixing in replacement of unserviceable energy efficeint Ceiling fan 1200mm sweep, energy efficient ISI mark with 5 star rating 230 Volts AC 50 Hz, single phase including provision of fixing arrangement, nut and bolt and flexible 3 core of size 1.5 sqmm not less than 0.5 m long complete including taking down existing one, writing MES No with synthetic enamel paint all as specified and as directed. Make : Havells cat Part No. ES Neo or equivalent in Bajaj/ Orient. Note:- (a) The contractor shall given a written guarantee of minimum two years from completion of work. (b) Old Unserviceable ceiling fan shall be deposited to MES store yard.
Taking down of exhuast fan any size/capacity after disconnecting cable connection, and refixing same in original position after necessary repair/over hauling including replacement of parts of minor nature such as screws, lugs, insulation tape, nuts, bolts, washers etc after cleaning the metal surface, greasing/lubricant etc to make it functional and making connection by replacing PVC insulated unsheathed cable of copper conduct of size 1.5 Sqmm from ceiling rose/ connector fan (minimum 0.50 Mtr length) are deemed to be inclusive in quoted rate all as specified and as directed. (Note:- Repair, rewinding, over hauling and materials to be replaced are measured seperately.)
Note for item No 32 : The following shall be deemed to be inclusive in the unit quoted rate :- (a) In each job checking of functioning of fan including its connections, cleaning of fan, greasing of fan, mechanical check i.e. tightening of loose screw , nuts, bolts, are inclusive in unit quoted rate.
(b) The above job shall be carried out by a trained electrician having qualified in ITI ( electrician Trade), documentary proof of the education of tradesman shall be produced, before commencement of work.
(c) Defecting unserviceable part like fan bush, bearing etc will be paid under respective item here-in-after as supply only through proper documentation.
(d) The entire job will be carried out in Air Force stn Sulur and necessary documents showing qtr No, bldg No supported with user signature shall be prepared as per format directed by Engr-in-charge and will be deposited to concerned JE (E/M) within 24 hrs.
(e) Necessary complaint slip/complaint register & other stationery required shall be contractor responsibility.
(f) Necessary T&P such as ladder, helper shall be contractor responsibility.
(g) All types of T&P, PVC insulation tape, minor nuts, bolts, washers etc required for maintaining the services shall be provided by contractor without any cost to the department.
(h) Any fan found defective/not working shall be brought to AGE E/M store yard & re-fixed after repairing.
(j) In case of major defects, entire job shall be completed within 10 days from the date of registration of complaint, failing which penalty charges @100/- per day shall be recovered.
(k) In case of minor defects, entire job shall be completed with 12 hrs from the time of registration of complaint, failing which penalty charges @ 50/- per job shall be recovered.
(l) The contractor shall maintain a record of all urgent/ routine works and if the work is repeated due to poor workmanship, he will be liable to repair the same without any extra expenditure to the Govt.
Material and labour for winding of Exhuast fan 450 mm sweep of any make with super enameled copper winding wire of existing gauge (wt of copper winding wire per fan 250 to 500 gms) including cutting and getting out old burnt winding, sleeve work, varnishing with E class insulation varnish, threading, connections with twin core copper flexible wire of size 0.0076mm of length not more than one meter with each fan complete all as specified and directed. Note :- (i) Motor shall be wound with machine inside MES complex only. (ii) Old burnt wire shall be contractor’s property and necessary credit shall be recovered as per credit shedule.
Description all as per Sl item No 44 here in above but 300 mm sweep
Description all as per Sl item No 44 here in above but 230 mm sweep
Supply only fan bush of suitable size for exhaust fan of the any sweep
Supply only 4 mfd capacity ceiling /exhaust fan condensors. Make:- Asian/ Tyton/ CG/ Usha
Supply only metal louvers of suitable size for exhaust fan of the 450mm sweep
Supply only fan bearing of suitable size for exhaust fan of 450mm sweep including greasing.
Supply only 3.15 mfd capacity ceiling /exhaust fan condensors. Make:- Asian/ Tyton/ CG/ Usha
Supply only metal louvers of suitable size for exhaust fan of the 300mm sweep
Supply only fan bearing of suitable size for exhaust fan of 300mm sweep including greasing.
Supply only 2.5 mfd capacity ceiling /exhaust fan condensors. Make:- Asian/ Tyton/ CG/ Usha
Supply only metal louvers of suitable size for exhaust fan of the 230mm sweep
Supply only fan bearing of suitable size for exhaust fan of 230mm sweep including greasing.
M&L painting the exhaust fan of 450mm sweep with one coat of syntetic enamel paint as exiting colour and writing the MES No and return to MES storeyard /user unit from the work shop .as directed by Engr in Charge. Note:- Painting of ceiling fan shall be done inside MES complex only.
All as per item No 57 above but 300 mm sweep
All as per item No 57 above but 230 mm sweep
S&F Domestic Exhaust Fans for kitchen, 300 mm sweep, 230 volt suqare type, heavy duty, 1400 RPM, corrosion less mild steel body of motor, plastic/ fibre blade for noise less operation, self operating louvers gives powerful performance round the clock, including necessary cutting, making holes on stone/brick walls where required, fixing arrangement with MS pipe 350 mm dia of required length for protect deshape of stone masonery, suitable hold fast with necessary nut, bolts / screws including taking down existing one writing MES No with synthetic enamel paint all specified and directed. Make- havells model-Ventil Air-DB or equivalent in bajaj, Almonard. Note:- Old Unserviceable domestic exhaust fan shall be deposited to MES store yard.
S&F Exhaust fan 200 mm sweep 230 volt square type, heavy duty with louvers of PVC body including necessary nut, bolts / screws including taking down existing one writing MES No with synthetic enamel paint all specified and directed. Make-Havells Cat No Ventil DX-WH/BLK or equivalent in bajaj, Crompton Greaves etc. Note:- Old Unserviceable Exhaust fan shall be deposited to MES store yard.
Shifting of pedestal fan of any size/capacity from site/MES store to MES Complex for replacement of defective part/ painting/winding & reposition same. Note :- Repair, rewinding material to be replaced are measured separetely.
M&L for winding of pedastal fan of 630 mm sweep of any make, cleaning the slots with super enameled copper winding wire of existing gauge (wt of copper winding wire per fan 350 to 500 gms) including cutting and getting out old burnt winding, sleeve work, varnishing with E class insulation varnish, threading, connections with twin core copper flexible wire of size 0.0076mm of length not more than one meter with each fan complete all as specified and directed. Note :- (i) Motor shall be wound with machine inside MES complex only. (ii) Old burnt wire shall be contractor’s property and necessary credit shall be recovered as per credit shedule
Description all as per Sl item No 63 here in above but 450 mm sweep
Description all as per Sl item No 63 here in above but 400 mm sweep
Supply only fan bush of suitable size for peadstal fan of any sweep
Supply only of fan bearing of suitable size for peadstal fan of 630 mm sweep
Description all as per Sl item No 67 here in above but 450 mm sweep
Description all as per Sl item No 67 here in above but 400 mm sweep
M&L painting the pedastal fan of 630 mm sweep with one coat of syntetic enamel paint as exiting colour and writing the MES No and return to MES storeyard /user unit from the work shop as directed by Engr in Charge.
Description all as per Sl item No 70 here in above but 450 mm sweep
Description all as per Sl item No 70 here in above but 400 mm sweep
Taking down of wall mounted fan any size/capacity after disconnecting cable connection, and refixing same in original position after necessary repair/over hauling . (Note:- Repair, rewinding, over hauling and materials to be replaced are measured seperately.)
Supply only fan bearing of suitable size for wall mounted fan of 630mm sweep make-: SKF/TATA/NBC
Description all as per Sl item No 74 here in above but 400 mm sweep.
Supply only fan bush of suitable size for wall mounted fan of the any sweep
Material and labour for winding of wall mounted fan 630 mm sweep of any make with super enameled copper winding wire of existing gauge (wt of copper winding wire per fan 350 to 500 gms) including cutting and getting out old burnt winding, sleeve work, varnishing with E class insulation varnish, threading, connections with twin core copper flexible wire of size 0.0076mm of length not more than one meter with each fan complete all as specified and directed. Note :- (i) Motor shall be wound with machine inside MES complex only. (ii) Old burnt wire shall be contractor’s property and necessary credit shall be recovered as per credit shedule.
Description all as per Sl item No 77 here in above but 400 mm sweep
S&F wall mounted fan 300 mm sweep, power input 55 watt, 1380 RPM, air delivery-75 CMM, single phase 230 volts high performance motor with over heat protection world class styling & finish, facility to control wind & nature mode, aerodynamically designed balanced AS blades including fixing arrangement on wall including taking down existing one writing MES No with synthetic enamel paint all as specified and directed. Make:- Havells Model -Swing HS, Bajaj or Polar. Note:- Old Unserviceable wall mounted fan shall be deposited to MES store yard.
M&L for winding of table fan of any sweep of any make, cleaning the slots with super enameled copper winding wire of existing gauge (wt of copper winding wire per fan 350 to 500 gms) including cutting and getting out old burnt winding, sleeve work, varnishing with E class insulation varnish, threading, connections with twin core copper flexible wire of size 0.0076mm of length not more than one meter with each fan complete all as specified and directed. Note :- (i) Motor shall be wound with machine inside MES complex only. (ii) Old burnt wire shall be contractor’s property and necessary credit shall be recovered as per credit shedule
Supply only of bearing of suitable size for table fan of any sweep
Supply only blades (made of aluminum) suitable for any sweep table fan of any make with set of screws complete all as specified and directed .
Taking down aluminum/copper point wiring on & including hard wood battens, surface conduit and board/ blocks etc or through conduits for light, socket or power point, fan point complete (Taking down of fittings such as switches, sockets, bells, ceiling rose, holders , regulators light fittings, MCB, lamps etc shall be measured and paid seperately) and making good the disturbed plaster surfaces of wall, floor, ceiling and apply 2 coat of white wash/distemper to meet the existing surface and removing materials and debris to reinstate the premise neat and clean complete all as specified and directed.
M&L for point wiring using approved colour coding as per IS with 1.5 sqmm single core PVC insulated, unsheathed FRLS cable 1100 volts grade ISI 694 marked, multi stranded with copper conductor drawn through and incl concealed PVC conduit heavy duty, 19/20mm dia, ISI marked with accessories in wall/roof/ceiling etc incl terminal boxes fabricated with 1.6mm MS/ cast iron sunken boxes duly painted with two coats of anticorrosive paint over a coat of red oxide primer on surface in touch with wall and synthetic enamel paint over a coat of red oxide on other side, covered with 3mm thick plastic laminated sheet for mounting switches, regulators, sockets etc including 1.5 sqmm (nominal area) copper conductor PVC insulated, unsheathed, multi stranded FRLS cable as earth wire and connected to earth dolly complete all as specified and as directed. Make of conduit : Avon Plast/Supreme/Diplast Make of wire : Plaza/Havells/Poly Cab Note:- (a) Switches, sockets outlets, blanking plate, Light fittngs, fans, bells & regulators will be measured and paid for separetely. (b) Connection of wire with switch, socket shall be done through copper thimble (lugs) only.
One light point/fan/bell point controlled by one switch
Description all as per Sl item No 84 here in above but for one 3 pin socket out 5 amp on the same board
Description all as per Sl item No 84 here in above but for one switch socket outlet 3 pin 5 Amps on independent board
Description all as per Sl item No 84 here in above but Wiring with 4 Sqmm copper multistranded unsheathed cable and 4 Sqmm copper cable for earth continuity conductor controlled by one 15A switch socket independently
Sub main wiring with PVC insulated unsheathed FRLS 1100 volts grade multi stranded copper conductor cable 4 runs of 4 sqmm drawn through in and incl suitable size PVC casing capping and all accessories fixed to wall/floors along with 2 runs of 4 sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring all as directed. Make of Casing capping -Poly Cab/Modi/ Presto Plast Make of Cable : Plaza/Polycab/Havells Note: 4 runs of 4 sqmm cable along with two run of 4 sqmm cable for earth conductor alongwith suitable size PVC casing capping shall be measured as one length.
Sub main wiring with PVC insulated unsheathed FRLS 1100 volts grade multi stranded copper conductor cable 4 runs of 4 sqmm drawn through in and incl suitable size PVC conduit and all accessories fixed to wall/floors along with 2 runs of 4 sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring all as directed. Make of conduit : Avon Plast/Supreme/Diplast Make of Cable : Plaza/Polycab/Havells Note: 4 runs of 4 sqmm cable along with two run of 4 sqmm cable for earth conductor alongwith suitable size PVC conduit shall be measured as one length.
S&F in replacement factory made powder coated distribution board SP & N 8 way, including bus bar, Neutral bar, standard DIN rail, earth bar acomplete all as specified and conforming to IS: 8623 all as specified. Make/Model : Legrand/ Schnieder/ ABB.
S&F in replacement of MCB four pole, 32 Amp ultimate breaking capacity 16 KA complete conforming to IEC -61439-1 complete all as specified. Make : Legrand / Schnieder/ABB.
S&F in replacement of double pole MCB 40 amp, 240 v, 50 Hz AC suitable for ‘C’ curve, 10 KA breaking capacity complete conforming to IS 8828 of 1996 all as specified (Make/Model : Legrand/Schnieder/ ABB.
Sub main wiring with PVC insulated unsheathed FRLS 1100 volts grade multi stranded copper conductor cable 4 runs of 10 sqmm drawn through in and incl suitable size PVC casing capping and all accessories fixed to wall/floors along with 2 runs 10 sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring all as directed. Make of Casing capping -Poly Cab/Modi/Presto Plast Make of Cable : Plaza/Polycab/Havells Note: 4 runs of 10 sqmm cable along with two run of 10 sqmm cable for earth conductor alongwith PVC casing capping shall be measured as one length.
M&L for point wiring using approved colour coding as per IS with 1.5 sqmm single core PVC insulated, unsheathed FRLS cable 1100 volts grade multi stranded with copper conductor drawn through and incl PVC Casing capping with accessories in wall/roof/ceiling etc incl MS/ cast iron sunken boxes duly painted with two coats of anticorrosive paint over a coat of red oxide primer on surface in touch with wall and synthetic enamel paint over a coat of red oxide on other side, covered with 3mm thick plastic laminated sheet for mounting switches, regulators, sockets etc including 1.5 sqmm (nominal area) copper conductor PVC insulated, unsheathed, multi stranded FRLS cable as earth wire and connected to earth dolly complete all as specified and as directed. Make of Casing capping -Poly Cab/Modi/ Presto Plast Make of Cable : Plaza/Polycab/Havells Note:- (a) (Switches, sockets outlets, blanking plate, Light fittngs, fans, bells & regulators will be measured and paid for separetely). (b) Connection of wire with switch, socket shall be done through copper thimble (lugs) only.
One light point/fan/bell point controlled by one switch
Description all as per Sl item No 95 here in above but for One 3 pin socket out 5 amp on the same board
Description all as per Sl item No 95 here in above but for one switch socket outlet 3 pin 5 Amps on independent board
Description all as per Sl item No 95 here in above but Wiring with 4 Sqmm copper multistranded unsheathed cable and 4 Sqmm copper cable for earth continuity conductor controlled by one 15A switch socket independently
Supply and fixing switch piano flush type 5 Amps 240 volts single pole one way. Make :- Anchor (Model Pental PC), Havells (Reo), SSK (Topline)
Description all as per Sl item No 100 here in above but 15 Amp Make :- Anchor (Model Pental PC), Havells (Reo), SSK (Topline)
Suuply and fixing shuttered socket out let 2 in 1, 3 pin 5 amp Make :- Anchor (Model Pental PC), Havells (Reo), SSK (Topline)
Supply and fixing shuttered socket outlet 2 in 1, 5 pin, 5 and15 amps Make :- Anchor (Model Pental PC), Havells (Reo), SSK (Topline)
Supply and fixing switch socket combination out let 3 pin 5 amps, flush type. Make :- Anchor (Model Pental PC), Havells (Reo), SSK (Topline)
Supply and fixing switch socket combination out let 5 in 1, 5 pin 5 and 15 amps, flush type. Make :- Anchor (Model Pental PC), Havells (Reo), SSK (Topline)
M&L for Ceiling rose flush type 6 Amps,250 volts AC ISI marked, Make :- Anchor (Model Pental PC), Havells (Reo), SSK (Topline)
Supply and Fix electronic fan regulator switch type stepped type 230 volts hum free 100/ 240 Watt complete all as specified and as directed. Make : Havells /Crabtree/Indo Asian
Supply and Fix electronic fan regulator socket type stepped type 230 volts hum free 100/ 240 Watt complete all as specified and as directed. Make : Havells /Crabtree/Indo Asian
S&F PVC rectangular/square block 75x75x35mm
M&L Sub main wiring with PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable 2 runs of 6 sqmm drawn through in and incl suitable size PVC casing capping and all accessories fixed to wall/floors along with 6 sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring all as directed. Make of Casing capping -Poly Cab/Modi/ Presto Plast Make of Cable : Plaza/Polycab/Havells Note: 2 runs of 6 sqmm cable along with one run of 6 sqmm cable for earth conductor alongwith suitable size PVC casing capping shall be measured as one length
M&L Sub main wiring with PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable 2 runs of 6 sqmm drawn through in and incl suitable size PVC conduit and all accessories fixed to wall/floors along with 6 sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring all as directed. Make of conduit : Avon Plast/ Supreme/ Diplast Make of Cable : Plaza/Polycab/Havells Note: 2 runs of 6 sqmm cable along with one run of 6 sqmm cable for earth conductor alongwith suitable size PVC conduit shall be measured as one length
S&F in replacement factory made powder coated distribution board SP & N 12 way, including bus bar, Neutral bar, standard DIN rail, earth bar acomplete all as specified and conforming to IS: 8623 all as specified. Make/Model : Legrand/ Schnieder/ ABB.
S&F in replacement of MCB four pole, 63 Amp ultimate breaking capacity 16 KA complete conforming to IEC -61439-1 complete all as specified. Make : Legrand/Schnieder/ ABB.
S&F in replacement of single pole MCB 6 to 32 Amps, 240 v, 50 Hz AC suitable for ‘C’ curve, 10 KA breaking capacity conforming to IS 8828 of 1996 all as specified (Make/Model : Legrand/Schnieder/ ABB.
S&F in replacement 4 feet surface mounted battern type luminaire with a power consumption not more than 16 W, luminaire lumen output of 2000 lumens, luminaire efficacy > 120 lm/W with an operanting voltage range from 140V-270V. The luminaire shall have a white CRCA housing with a poly carbonate diffuser to provide uniform light and sleek design with width not more than. The luminaire shall have a CCT of 6500 K, CRI>80, power factor>0.95, SDCM<5, THD<10% and 50,000 burning hours as per L70B50 criteria. The luminaire shall have flicker content<5% and shall have high and low cut off with auto restart feature. The luminaire shall be EMI/ EMC complaint and shall have a internal surge protection of 4 KV. The luminaire shall have Class-1 Electrical insulation, Class-B serviceability (The driver can be replaced at site level). The luminaire shall not weight more than 7 Kg and the luminaire and driver shall be BIS approved with "R" number mentioned. Make : Philips Cat No BN308C LED20S 6500 L120 PSU WH or equivalent in Bajaj or Wipro.
Note for item No 115 :- (a) LED Chip make shall be Nichia, Osram, Cree, Lumilid. (b) The contractor shall submit to Engineer-in-Charge LM-80 and LM-79 report from the NABL approved lab of LED Chip used and luminaise respectively while getting sample and material approved. (c) The contractor shall also submit test report from the manufacture to comply with all requirements and specifications given in the contract. (d) The contractor shall submit warranty certificate from manufacturer for minimum 02 years.
Excavation in trenches not exc 1.5m depth and not exe 1.5m width in hard/dense soil and getting out
Riddling Sand obtained from excavation for cable protection 8cm under the cable and 15cm above the cable in trench and get the thick layer of 18cm after ramming. Note :- In case sufficient sand not obtained from execution, the required additional qty obtain from out side land as directed by the Engineer-in-Charge. The rate is deemed to be included.
M&L Fly ash cable protection cover including taking down existing bricks of any size.
Returning, filling in including spreading, leveling, watering and well ramming in layers not exe.25cm in hard and dense soil
Removal of surplus soil to a distance not exe 50m and depositing where directed at a level not exe1.5m above the starting point
Supply & Laying XLPE insulated,screened ,PVC Bedded, galvanised steel strip of wire armoured, electric power cable heavy duty with aluminium condutor 1100Volts grade cross sectional area 16 Sqmm 4 core laid in trenches /ducts/fixed to wall/pole/ inside panel/ drawn through pipe including cable glands and terminal sockets etc including taking down existing cable all as specified and directed. Make of cable : Havells/KEI/Poly Cab Note : Excavation and earth work shall be measured and paid seperately.
Supply & Laying XLPE insulated,screened ,PVC Bedded, galvanised steel strip of wire armoured, electric power cable heavy duty with aluminium condutor 1100Volts grade cross sectional area 10 Sqmm 2 core laid in trenches /ducts/fixed to wall/pole/ inside panel/ drawn through pipe including cable glands and terminal sockets etc including taking down existing cable all as specified and directed. Make of cable : Havells/KEI/Poly Cab Note : Excavation and earth work shall be measured and paid seperately.
Wiring complete with 1.5 sqmm single core PVC insulated, unsheathed FRLS cable 1100 volts grade, multistranded copper conductor drawn through ERW conduit with all accessories fixed to the surface of wall/ roof/ ceiling etc and MS terminal boxes fixed surface/ concealed in walls covered with plastic laminated top cover 2.8mm fixed with cadmium plated iron screws etc including 1.5 sqmm PVC insulated, unsheathed copper conductor multistranded FRLS cable 1100V grade as earth continuity conductor and connecting to common earth dolly all as specified for one light/ fan point controlled by one switch.
Description all as per Sl item No 124 here in above but wiring with 4 sqmm copper multistranded unsheathed cable and 4 sqmm copper cable for earth continuity conductor controlled by one 15A switch socket independently.
S&F switch flame proof rotary type with termination box in LM6, 16 Amps single pole 250 V, Make : Sudhir, Bajaj, Baliga.
S&F switch flame proof switch socket and plug combined in LM6 cable termination box in LM6, 16A, 250V, 2P + earth, Make : Sudhir, Bajaj, Baliga.
S&F Fluorescent tube light fitting, 2 x 36W flameproof type FLP-WP made of aluminium alloy LM6, with electronic ballast, bipin holders, connector block, etc. complete with all accessories prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable size.
S&F flame proof exhaust fan 450mm sweep 230 volts, with all accessories fixed on wall/ceiling including taking down existing one writing MES No with synthetic enamel paint all specified and directed. Make : Sudhir or equivalent in Bajaj, Baliga. Note:- Old Unserviceable flame proof exhaust fanshall be deposited to MES store yard.
S&F water proof 16A switch socket, IP 55 protection, 3 module enclosure with 16A switch and socket surface mounting, shock proof 240V AC. Make : C&S, Legrand, Schneider.
Earthing with Galvanised Earth Plate Electrode 600x600x 6mm thick burried directly in Ground (Earth Pit not less than 2.25 Metre below Ground Level) with Top edge of the Plate not less than 1.50 Metre below Ground Level, connected with Galvanised Earth Strip of size 25x6mm by means of Bolts, Nuts, Check Nuts and Washers of GI or Steel and connected Earthing Testing Point/Bus-bar including GI 40mm bore (dia) light grade Protection Pipe, Earth Plate surrounded by a packed thickness of Char Coal or Coke Dust mixed with Common Salt, Magneisum Sulphate (1 : 1 : 0.5) in alternate layers of not exc 150mm thick, PCC Pit in Cement Concrete 1:3:6 (20mm graded stone aggregate) and Pre-cast RCC Cover Slab of size 350x350x50 mm in Cement Concrete 1:2:4 (20mm graded stone aggregate), reinforced with 10mm dia TMT Bars @ 100mm Centre to Centre in both ways, GI Wire Mesh, Funnel with GI Watering Pipe 20mm bore (dia) medium grade including necessary Excavation in any type of soil, Returning, Filling in and Removal of surplus Spoil disposal to out side MD land and all as shown in Electrical Plate No. 3 of MES Schedule Part-I and Testing on Completion including taking down old unserviceable one, complete all as per specified and as directed.
Note for item No 131 :- (a) All Joints should be joined by Exothermic Welding or Brazing.
(b) After completion of work earthing shall be tested by the contractor in presence of Engineer-in-Charge, User and proper record shall be maintained.
(c) Earth resistance tester shall be provided by the contractor. It should be caliberated from authorised company/ lab.
(d) After testing if desired earth resistance of less than 5 Ohm is not obtained, the earthing will be redone at no extra cost to Govt till desired result is obtained.
M&L Galvanised Earth strip of size 25 x 6 mm fixed on proper post insulator at the instrument end including taking down.
KUMAR AGENCIES
rvelectricals
A.GOVINDARAJ
SARAVANARAJA CONSTRUCTIONS
LAKSHMI ELECTRICAL ENTERPRISES
T C KARUNANITHI
NAVEEN ENTERPRISES
Neptune Engineers and Builders
SUPER COOL
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .