Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹75.3 LAccepted-AOC 24 A RAGHBIR MARG NEAR 22 NO PHATAK PATIALA 147001 PB | PATIALA | PATIALA | PUNJAB | 147001 | L1 | Accepted-AOC The lowest tenderer | |
| 2 | L2₹76.4 L+₹74,710 (0.99%)Rejected-Finance | L2 | Rejected-Finance Not the lowest tenderer | |
| 3 | L3₹77.8 L+₹2.1 L (2.73%)Rejected-Finance 04 L BLOCK MARKET SECTOR 11 NOIDA 201301 UP GAUTAM BUDHA NAGAR | GAUTAM BUDDHA NAGAR | UTTAR PRADESH | 201301 | L3 | Rejected-Finance Not the lowest tenderer | |
| 4 | L4₹82.7 L+₹7.0 L (9.23%)Rejected-Finance | L4 | Rejected-Finance Not the lowest tenderer | |
| 5 | L5₹82.9 L+₹7.2 L (9.51%)Rejected-Finance 33 CHANDASI HOUSE LANE NO 11 S K PURAM ARYA SAMAJ MANDIR ROAD RPS MORE BAILEY ROAD DANAPUR PATNA BIHAR 801503 | PATNA | PATNA | BIHAR | 801503 | L5 | Rejected-Finance Not the lowest tenderer |
Tender Value
Refer Docs
EMD Value
₹1.6 L
Closing Date
17 Jun 2024, 6:00 pmClosed
HQ CWE SRI GANGANAGAR
HQ CWE POST BOX 48 SRI GANGANAGAR-335001 (Rajasthan)
SPL REPAIR TO HT TRANSFORMERS AGAINST BER AT SRI GANGANAGAR MIL STN
2024_MES_655870_1
CA NO CWE SGNR T-06 OF 2024-25
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE SRI GANGANAGAR
as per NIT
9 documents required · 9 mandatory
₹1,000
Yes
GE SRI GANGANAGAR
₹1.6 L
31 Aug 2024
25 May 2024
18 Jun 2024
25 May 2024
17 Jun 2024
10 Jun 2024
Amount
Supply, installation, Testing, Commisioning of Oil Cooled, Copper wound, Step down transformer of Capacity 400 KVA plinth mounted indoor type with latest feature complete with standard fitted HT 11 KV 3 phase, LT 433 V 3 phase 4 wire,50 C/S oil immerese, naturally cooled externally cooling tube delta connection on primary HT 11 KV side and star connection on secondary LT 433V with tapping at + 2.5 %to + 5 % & + 7.5 % on HV side and to be changed by means of hand operated off load/ tap changing gear including first filling of new transformer oil of dilectric strength not less than 55 KV with all fitting and accessories such as LT box with gland, HT box with gland, Silica gel,breather, Oil level indicatorgauge, drain out valve (oil tank),exhaust vent, air release valve, temp gauge, cast iron wheel etc comply with EEL 3, IS 1180 2014 with amendment 1,2 & 3 or EEL 2 IS 1180 2014 with amendment 1,2,3 & 4 effective after 30.03.2022 having total loss at 50% load 1080 W and at 100% load 3214 W complete all as specified and directed by Engineer -in-charge . Following items/ Accessories included in this rate therefore No any extra cost will be paid for these items:-
(a) Name , rating & diagram plate. (b) Off circuit tap changing switch if not opted for OLTC. (c) Eearthing terminals. (d) Lifting lugs. (e) Magnetic oil level indicator (having contact for alarm and trip). (f) Oil drain valve with plug. (g) Oil filter valve with plug. (h) Conservator with oil filling hole with cap. (j) Thermometer pocket. (k) 4” dial type thermometer stem type & with MRP (if OTI not opted). (l) Air release plug. (m) Silica gel breather. (n) Removable inspection opening on top cover (on & above 160 KVA). (o) Explosion vent (if PRV not opted). (p) Bidirectional CI. rollers (on & above 1000 KVA) otherwise unidirectional. (q) Oil temp indicator 6'' dial type (having contact for alarm and trip). (r) Winding temp indicator (having contact for alarm and trip). (s) Pressure relief valve (having contact for alarm and trip).
Supply, installation, Testing, Commisioning of Oil Cooled, Copper wound, Step down transformer of Capacity 250 KVA plinth mounted out door type with latest feature complete with standard fitted HT 11 KV 3 phase, LT 433 V 3 phase 4 wire,50 C/S oil immerese, naturally cooled externally cooling tube delta connection on primary HT 11 KV side and star connection on secondary LT 433V with tapping at + 2.5 %to + 5 % & + 7.5 % on HV side and to be changed by means of hand operated off load/lap changing gear including first filling of new transformer oilof dilectric strength not less than 55 KV with all fitting and accessories such as LT box with gland, HT box with gland, Silica gel,breather, Oil level indicatorgauge,drain out valve (oil tank),exhaust vent, air release valve, temp gauge, cast iron wheel etc comply with EEL 3, IS 1180 2014 with amendment 1,2 & 3 or EEL 2 IS 1180 2014 with amendment 1,2,3 & 4 effective after 30.03.2022 having total loss at 50% load 864 W and at 100% load 2488 Wcomplete all as specified and directed by Engineer -in-charge . Following items/ Accessories included in this rate therefore No any extra cost will be paid for these items:-
(a) Name , rating & diagram plate. (b) Off circuit tap changing switch if not opted for OLTC. (c) Eearthing terminals. (d) Lifting lugs. (e) Magnetic oil level indicator (having contact for alarm and trip). (f) Oil drain valve with plug. (g) Oil filter valve with plug (on & above 160 KVA). (h) Conservator with oil filling hole . (j) Thermometer pocket. (k) 4” dial type thermometer stem type & with MRP (if OTI not opted). (l) Air release plug. (m) Silica gel breather. (n) Removable inspection opening on top cover (on & above 315 KVA). (o) Explosion vent (if PRV not opted). (p) Bidirectional CI. rollers (on & above 1000 KVA) otherwise unidirectional (on & above 160 KVA). (q) Oil temp indicator 6'' dial type (having contact for alarm and trip). (r) Winding temp indicator (having contact for alarm and trip). (s) Pressure relief valve (having contact for alarm and trip).
Supply, installation, Testing, Commisioning of Oil Cooled, Copper wound, Step down transformer of Capacity 200 KVA plinth mounted out door type with latest feature complete with standard fitted HT 11 KV 3 phase, LT 433 V 3 phase 4 wire,50 C/S oil immerese, naturally cooled externally cooling tube delta connection on primary HT 11 KV side and star connection on secondary LT 433V with tapping at + 2.5 %to + 5 % & + 7.5 % on HV side and to be changed by means of hand operated off load/lap changing gear including first filling of new transformer oilof dilectric strength not less than 55 KV with all fitting and accessories such as LT box with gland, HT box with gland, Silica gel,breather, Oil level indicatorgauge, drain out valve (oil tank),exhaust vent, air release valve, temp gauge, cast iron wheel etc comply with EEL 3, IS 1180 2014 with amendment 1,2 & 3 or EEL 2 IS 1180 2014 with amendment 1,2,3 & 4 effective after 30.03.2022 having total loss at 50% load 670 W and at 100% load 2100 Wcomplete all as specified and directed by Engineer -in-charge . Following items/ Accessories included in this rate therefore No any extra cost will be paid for these items:-
(a) Name , rating & diagram plate. (b) Off circuit tap changing switch if not opted for OLTC. (c) Eearthing terminals. (d) Lifting lugs. (e) Magnetic oil level indicator (having contact for alarm and trip). (f) Oil drain valve with plug. (g) Oil filter valve with plug (on & above 160 KVA). (h) Conservator with oil filling hole . (j) Thermometer pocket. (k) 4” dial type thermometer stem type & with MRP (if OTI not opted). (l) Air release plug. (m) Silica gel breather. (n) Removable inspection opening on top cover (on & above 315 KVA). (o) Explosion vent (if PRV not opted). (p) Bidirectional CI. rollers (on & above 1000 KVA) otherwise unidirectional (on & above 160 KVA). (q) Oil temp indicator 6'' dial type (having contact for alarm and trip). (r) Winding temp indicator (having contact for alarm and trip). (s) Pressure relief valve (having contact for alarm and trip).
Supply, installation, Testing, Commisioning of Oil Cooled, Copper wound, Step down transformer of Capacity 100 KVA plinth mounted Out door type with latest feature complete with standard fitted HT 11 KV 3 phase, LT 433 V 3 phase 4 wire,50 C/S oil immerese, naturally cooled externally cooling tube delta connection on primary HT 11 KV side and star connection on secondary LT 433V with tapping at + 2.5 %to + 5 % & + 7.5 % on HV side and to be changed by means of hand operated off load/lap changing gear including first filling of new transformer oilof dilectric strength not less than 60 KV with all fitting and accessories such as LT box with gland, HT box with gland, Silica gel,breather, Oil level indicatorgauge,drain out valve (oil tank),exhaust vent, air release valve, temp gauge, cast iron wheel etc comply with EEL 3, IS 1180 2014 with amendment 1,2 & 3 or EEL 2 IS 1180 2014 with amendment 1,2,3 & 4 effective after 30.03.2022 having total loss at 50% load 435 W and at 100% load 1500 W complete all as specified and directed by Engineer -in-charge . Following items/ Accessories included in this rate therefore No any extra cost will be paid for these items:-
(a) Name , rating & diagram plate. (b) Off circuit tap changing switch if not opted for OLTC. (c) Eearthing terminals. (d) Lifting lugs. (e) Magnetic oil level indicator (having contact for alarm and trip). (f) Oil drain valve with plug. (g) Oil filter valve with plug (on & above 160 KVA). (h) Conservator with oil filling hole . (j) Thermometer pocket. (k) 4” dial type thermometer stem type & with MRP (if OTI not opted). (l) Air release plug. (m) Silica gel breather. (n) Removable inspection opening on top cover (on & above 315 KVA). (o) Explosion vent (if PRV not opted). (p) Bidirectional CI. rollers (on & above 1000 KVA) otherwise unidirectional (on & above 100 KVA). (q) Oil temp indicator 6'' dial type (having contact for alarm and trip). (r) Winding temp indicator (having contact for alarm and trip). (s) Pressure relief valve (having contact for alarm and trip).
Supply, laying & testing cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 11000 volts grade, of size 3 core 120 sq mm including taking down complete all as specified and directed.
Supply, laying & testing cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 11000 volts grade, of size 3 core 95 sq mm including taking down complete all as specified and directed.
Supply, laying & testing cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 1100 volts grade, of size 3.5 core 240 sq mm including taking down complete all as specified and directed.
Supply, laying & testing cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 1100 volts grade, of size 3.5 core 120 sq mm including taking down complete all as specified and directed.
Supply and fix cable jointing kit for 11 KV grade cable for outdoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Al conductor cable of size 120 Sqmm complete all as specified and directed.
Supply and fix cable jointing kit for 11KV grade cable for Indoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Aluminium conductor cable of size 50 to 95 sqmm complete all as specified and as directed.
Supply and fix cable jointing kit for 11 KV grade cable for indoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Al conductor cable of size 120 Sqmm complete all as specified and directed.
Supply and fix cable jointing kit for 11KV grade cable for Outdoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Aluminium conductor cable of size 50 to 95 sqmm complete all as specified and directed.
M&L for site clearance including surface dressing not exceeding averaging 15cm deep in soft/ loose soil and getting out including cutting of grass roots, bushes, tree branches and tree not exceeding 15 cm girth if any and filling of lower portion with soil obtained from cutting or dressing complete all as specified & directed by Engr-in-Charge.
Excavation in trenches, not exc 1.5 m wide and n. exc 1.5 m depth; or n exc 10 Sqm on plan and n exc 1.5 m in depth for foundations of poles, struts, stays etc. or laying underground cable etc. in soft/loose soil, & getting out complete all as specified and directed by Engineer-in-Charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers n.exc 25cm thick complete all as specified and directed by Engineer-in-Charge
Removal of excavated surplus soil to a distance n.exc 50m and depositing where directed at level not exceeding 1.5 m above the starting point complete all as specified & directed by Engineer-in-charge .
M & L for sand cushioning with dry coarse sand to under ground cable below and around after laying the cable jointly punning down complete all as specified and directed by Engineer-in-Charge. Note : Thickness after punning shall be considered for payment.
Supply and lay reinforced pre cast concrete cable cover class HV type 1 flat size 300 x 180 mm x 40mm all as specified and directed.
Supply and lay reinforced pre cast concrete cable cover class LV type 1 flat size 250 x 150 mm x 40mm all as specified and directed.
M & L for boring hole across the Road/plinth/hard standing by trench less technology method suitable for 100mm bore pipe for 0.4 mpa working pressure for cable passing without damaging Road / Plinth /Floor complete all as specified and directed.
M & L GI pipe light grade 80mm bore for cable protection complete all as specified and directed.
M & L for danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with MS clamps, bolts and nut of approved size for HT 25x20cm complete all as specified and directed.
Supply, Installation, Testing and Commissioning of Chemical Earthing based on 3 meters long GI earth pipe C grade as a electrode 50mm bore duly fixed with connector at top for connection of copper strip 32 x 6mm riveted/nut bolt after 12 mm boring. The Electrode is surrounded by mixture of TERRA GEL 20 kg and TERRA ECO 22Kg Chemical compund powder including providing of pit cover heavy duty plastic of suitable size all as per manufacturer specification complete all as specified and directed. Note : (i) Rate included for Testing commissioning including checking of earth continuity and earth result complete all as specified and as directed. (ii) Bidder are bound to get earthing result less than 1 ohm. If the result of earthing not achieved less than 1 ohm by one earthing then another additional earthing will be provided by the contractor as bi-pot including interconnecting with copper strip of same configuration at no extra cost to achieve test result as specified and all as directed by Engr-in -charge. (iii) Rates for copper strip of size 32x6 mm up to 7.5 RM will deemed to be included in quoted rates. (iv) GI earth strip beyond 7.50 Mtr shall be measured and paid Separately under relavent items
M&L GI strip of size 32x6mm buried in ground and connected one end to electrode terminal and other end to terminal box with suitable size of GI nut, bolt & washers complete all as specified and directed.
Taking Down old existing BER distribution Transformers and shifting to MES Store Yard safely complete all as specified and as directed for desposal action.
Material and Labour for repair of broken or damanged plinth of existing transformers by using Bricks, Brickwork with sub- class ‘B’ bricks straight or curved on plan exc 6 m mean radius, old size bricks bedded in jointed in sub pointed Cement mortar 1:6 complete all as specified and directed by Engineer-in-Charge.
M&L for 10 mm thick rendering on brick surface in cement mortar 1:3 finished even and smooth without using extra cement complete all as specified and directed.
Vinod Kumar Bajaj
GEPS PROJECTS
M/S YOGANSH CONSTRUCTION CO.
Roy and Sons Infrastructures
Raman Electric Trading Co
Aggarwal brothers and company
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .