Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.4 LAccepted-AOC 2 LOCKHART ROAD NEAR PCDA P OFFICE PRAYAGRAJ U P PIN 211014 | PRAYAGRAJ | UTTAR PRADESH | 211014 | L1 | Accepted-AOC being L1 | |
| 2 | L2₹33.6 L+₹2.7 L (8.69%)Rejected-Finance | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹34.6 L+₹3.7 L (12.0%)Rejected-Finance | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹35.8 L+₹5.0 L (16.1%)Rejected-Finance | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹37.0 L+₹6.1 L (19.8%)Rejected-Finance | L5 | Rejected-Finance Other than L1 |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
30 Sept 2024, 6:00 pmClosed
GE WEST PRAYAGRAJ
GE WEST PRAYAGRAJ PIN-211001
SPL REPAIR TO ROOF FALSE CEILING OF BLDG NO. 584 585 BLDG NO. 16 MI ROOM TRG CELL OF 111 INF BN TA KUMAON TRIVENI VIHAR AT NEW CANTT PRAYAGRAJ
2024_MES_670062_1
8760/E8
Open Tender
Civil Works
Item Rate
180 days
NEW CANTT PRAYAGRAJ
As per tender Documents
8 documents required · 8 mandatory
₹500
GE WEST PRAYAGRAJ
₹98,000
Yes
23 Nov 2024
2 Sept 2024
7 Oct 2024
2 Sept 2024
30 Sept 2024
16 Sept 2024
Amount
Demolition of plain cement concrete in any position including tar felt & cement mortar bedding etc from roof or sunken etc complete all and removing debris as specified and directed.
Demolition of mud in roofs, any thickness, including plastering and leaping ( whether full thickness removed or only a part thereof) & disposal of retrieved material where directed complete all as specified and directed. Note:- Removal of demolished material shall be measured & paid under respective item.
Dismantling of brick tiles or terracing tiles, single layer on roofs complete all as specified and directed.
M&L for plain cement concrete 1:2:4 type B-0 12.5mm graded stone aggregate as in roof padding, roof kerbs, benching on roof slab and other similar works laid as per slop required finished even and fair complete all as specified and directed.
M&L for 10mm thick plaster in CM 1:3, mixed with liquid water proofing compound over concrete surface of roof /chajja on cleaning of surface complete all as specified and directed. (Note : WPC to be measured and paid separately under appropriate item)
Cleaning the dust, dirt and any other foreign material from roof surface and applying a coat of bituminous primer @ 0.40 ltr / Sqm uniformly and primer shall be allowed to dry over night as conforming to IS 3384-1986 complete all as specified and directed.
M&L for Laying of minimum 3mm thick APP membrane of (reinforced with non-woven fabric polyester type wt not less than 150 gms/Sqm) & minimum weighing 3kg/Sqm shall be done using butane torch maintaining 100mm side overlap and 150mm end overlap, sealing all overlaps and bonded to the surface by fusing and bonding torch on method complete all as specified and directed. Note: All water proofing work shall be done as per manufacturer instruction and under supervision of manufacturer technical representative.
Supply only Liquid water proofing compound (ISI marked) complete all as specified and directed.
M&L for 40mm thick brick tiles laid over and including 20mm thick screed bed in CM 1:4 mixed with polymer based liquid water proofing additive @ 5 % by weight of cement or as per manufacturer's instruction and the joints of tiles shall be filled with CM 1:3 mixed with crude oil as per SSR-2009 (Part-I) on roof area and proper curing with water by ponding complete all as specified and directed.
All as per item No 9 but except tiles complete all as specified and directed. Note:- Tile obtained from dismantling shall be used.
S&F in repair rotational moulded polyethylene water storage tank of capacity 500 ltr (Cylindrical/vertical with closed top) double layer construction, ISI marked hoisted & fixed in position including dismantling of old tank and removing from site complete all as specified and directed.
S&F in repair ball/ float valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed 20mm bore minimum weight 210 gms complete all as specified and directed.
Removing building materials (mud phuska) from site etc to a distance of not less than 1 Km including loading unloading and stacking at the destination complete all as specified and directed.
M&L for preparation of newly plastered surface of wall with scrapping machine tools/electric hand grinder with wire brushes, sand papering and applying two coats of cement base paint including one coat of primer complete all as specified and directed.
M&L for RCC M-25 (design mix) using 20 mm graded stone aggregate as in chajja etc and the like with necessary form work complete all as specified and directed. Note:- Reinforcement & formwork to be measured & paid separately under respective item.
Use & waste of formwork to chajja, trough and similar item including edge etc rough finished complete all as specified and as directed.
M&L TMT bar 10 mm dia and over, cut to length, bent to shape required ,including cranking ,bending spirally for hooping for columns, hooking end and binding with and including mild steel wire and annealed not less than 0.9 mm dia or securing with clips complete all as specified and directed.
Taking up or down 15 mm bore GI steel tubing and connections on (walls, ceiling, floors, etc.) including cleaning complete all as specified and as directed
Refixing old 15 mm bore GI steel tubing and connections in new or old position (Walls, ceiling, floors, etc.) complete all as specified and as directed
S&F 15 mm bore GI steel tubing "medium grade" with all fittings and fixed to wall, floor and ceiling etc complete all as specified.
Taking up or down 20 mm bore GI steel tubing and connections on (walls, ceiling, floors, etc.) including cleaning complete all as specified and as directed
Refixing old 20 mm bore GI steel tubing and connections in new or old position (Walls, ceiling, floors, etc.) complete all as specified and as directed
S&F 20 mm bore GI steel tubing "medium grade" with all fittings and fixed to wall, floor and ceiling etc complete all as specified.
Cutting holes in full brick walls, built in cement mortar for inserting of sunken pipe , holdfasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 Type B-1 as required complete all as specified and directed.
S & F in repairs 110 mm bore PVC (SWR) pipes singles socket in any length with rubber ring joints fixed to walls or floor or in trench complete all as specified and directed.
S & F in repair 110 mm bore PVC (SWR) bend any radius complete all as specified and directed.
S & F in repair 110 mm bore PVC (SWR), junction single, (Single T) equal or unequal complete all as specified and directed.
Demolition of brickwork of any description and in any position built in cement or cement lime mortar including all coin, arches, pillars complete all as specified and directed.
M & L for brickwork with old size fly ash, straight or curved on plan exc 6 m mean radius, built in CM 1:6 complete all as specified and directed.
M&L for rendering 15mm thick in CM 1:4 on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed.
Demolition of cement concrete including floor tiles or stone in any description and any position etc removal from site and complete all as specified and directed
Dismantling plain or corrugated steel sheeting any gauge thickness including nanital or similar pattern roof covering complete all as specified and directed.
M & L Prepainted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, north light curves, fixed with zinc coated self drilling fastener including EPDM washer complete laid with one corrugation side laps and min 150 mm end lap laid to slope all as per manufacturer / profile maker instruction & fixed with self tapping screws complete all as specified and directed.
M & L Prepainted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
Dismantling wrought iron or mild steel work, rolling shutters of any description not otherwise provided for complete all as specified and directed.
S & F steel work in tubular trusses, purlins, rafter, column where connected common rafter and running rails fixed with angle cleat or other common plates including special shaped washer etc complete using ERW or induction butt welded tubes conforming to IS.1161-1979 grade St.-240 complete all as specified and directed.
S&F in repair powder coated GI ceiling suspension system false ceiling grid of 600x 600mm size and 0.30 mm thick (MS galvanized (PPP CGS) with main tee, cross tee and wall angle grid hanging with 4mm dia Gl wire and roof fasteners or butterfly clips etc complete all as specified and directed.
S& F in repair hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia, 40mm long complete all as specified all as specified
S&F in repair 4 mm thick non asbestos fiber cement building board of 600x600 mm in size (HPSC E-classic) decorative finish fixed to aluminum /CGI frame work with hold down clips in false ceiling complete all as specified and directed.
Preparation of newly steel surfaces exc 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer with paint sprayers , complete all as specified and directed.
Complete removal of existing treatment on wall of old decorated surfaces by scrapping tools/electric hand grinder and applying 1mm thick wall care putty, after dry the layer of putty, apply two coats of oil bound distemper white or tinted with paint sprayer machine over a coat of primer complete all as specified and directed.
M&L for preparation of newly plaster surface of wall and applying two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 5489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 litre/ 10 sqm over new surfaces including one coat of 3mm birla wall care putty complete all as specified and directed.
M&L for 75 mm thick cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate as in sub base in Path, hard standing complete all as specified & directed.
Dismantling of floor hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises and removing debris complete all as specified and directed.
M&L for vitrified pavement outdoor tiles of 300mm X 300mm X 9-10 mm thick coloured for floor /pavement etc and jointed in solvent and pointed in coloured cement to match the tiles including 15mm thick screed bed or bedding layer in cement mortar 1:6 complete all as specified and as directed.
M & L for vitrified light shade floor tiles (scratch free) 10mm thick (square/ rectangular) area of each tile not exc 0.36 Sqm in floor etc set & jointed in neat cement slurry and pointed in white or coloured cement to match the surface with 15mm thick screed bed or bedding layer in CM (1:6) complete all as specified and directed.
M & L for vitrified light shade floor tiles (scratch free) 10mm thick (square/ rectangular) as in skirting /dado etc with and including 10 mm thick rendering in cement mortar 1:4 on wall complete all as specified and directed.
Taking down chowkat with shutter (without taking off shutters from the frame) area not exc 1.5 Sqm each and removing from site complete all as specified and directed.
Taking down chowkat with shutter (without taking off shutters from the frame) exc 1.5 Sqm but not exc 4.0 Sqm each and removing from site complete all as specified and directed.
S&F providing and fixing factory made UPVC white colour sliding window area not exceeding 2.00 Sqm each, three track made of extruded profiles with wall thickness of 2.3mm (+ -0.2mm). Window profile with hollow section with multi chamber. Frame (88mm x 52mm), sliding sash (42mm x 67mm), sliding mesh sash (42mm x 57mm), sliding interlock (One vertical length in each shutters) (45.5mm x 28mm), Glazing bead (24.5mm x 16mm) will be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware. EPDM gasket, 1.2+ -0.2 mm thick galvanised steel frame (30mm x 18mm) 2 Nos, sliding sash (30mm x 18mm), sliding mesh sash (26mm x 10mm) profile to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fasteners, Hardware [Touch Lock of zinc alloyed (white powder coated), steel roller system & stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40 mm and required accessories complete as per manufacturer's specification and directed. Note: (i) The unit rate quoted by contractor includes all connected accessories. (ii) Net Opening will be measured for payment purpose. (iii) Glass shall be measured & paid separately under respective item. (iv) Area not exceeding 2.00 Sqm each complete.
M&L for 75 mm thick cement concrete 1:3:6 type B2 using 40 mm graded stone aggregate in plinth protection finished even and fair including necessary form work and cutting of joints etc complete all as specified.
Taking down carefully point wiring of any type complete for light, fan socket or power point with fittings & fixtures such as ceiling rose, electric fittings, holders, switches, sockets, regulators, wooden batten, surface conduit/casing capping/conceal etc. removing materials including accessories for taking credit and making good disturbed surface to match the existing complete all as specified & directed.
M&L for point wiring with FRLS PVC insulated unsheathed stranded copper conductor cable 1.5 Sqmm (nominal area) 1100 volts grade, along with one single run of same size and type of copper wire as continuous earth wire to common earth dolly drawn in and including non metallic PVC rigid, medium grade conduit with all fixing accessories of 20mm dia, using new MS sunk terminal boxes of thickness not less 1.2mm, new 3mm thick laminated sheet cover with brass screw and cup washers with all accessories and making good to disturbed surfaces complete all as specified and directed for the following :- Note:(a) Colour code of wire shall be strictly followed , Red for Phase , Black for neutral and green for earth wire (b) The unit rate quoted is deemed to be inclusive of cost of cutting chases in wall for providing concealed conduit and making good to match with existing finish/surface.
One light/fan/bell point controlled by one switch
One point for socket outlet 5 amps on independent board
One point for socket outlet 5 amp same board.
All as per srl item No. 54 above but for one 3 pin socket outlet 15 amps, independent, with cables 2.5 sqmm size on independent board 2.5 Sqmm earth wire complete all as specified and directed.
All as per srl item No. 54 above but for one 3 pin socket outlet 15 amps, independent, with cables 4.0 sqmm size on independent board 4.0 Sqmm earth wire complete all as specified and directed.
Taking down carefully sub main wiring of any type complete with MCB DBs MCB, isolators wooden batten, surface conduit/casing conceal etc. removing materials including accessories for taking credit and making good disturbed surface to match the existing complete all as specified & directed.
M&L for concealed submain wiring using FRLSH PVC insulated, unsheathed stranded copper conductor cable two single core of size 4 Sqmm of voltage rating upto and including 1100 volts drawn in and including PVC concealed conduit of dia not less than 20 mm dia with all fittings and accessories along with one run of PVC insulated unsheathed stranded copper conductor of size 4 Sqmm as earth continuity conductor complete all as specified & directed. Note:- (i) Two runs of single core PVC cable with one run of earth conductor and conduit shall be measured as one length. (ii) The cost for cutting, chases required shall deemed to be included in the quoted unit rate.
M&L for concealed submain wiring using FRLSH PVC insulated, unsheathed stranded copper conductor cable two single core of size 6 Sqmm of voltage rating upto and including 1100 volts drawn in and including PVC concealed conduit of dia not less than 20 mm dia with all fittings and accessories along with one run of PVC insulated unsheathed stranded copper conductor of size 6 Sqmm as earth continuity conductor complete all as specified & directed. Note:- (i) Two runs of single core PVC cable with one run of earth conductor and conduit shall be measured as one length. (ii) The cost for cutting, chases required shall deemed to be included in the quoted unit rate.
S&F in repair ceiling rose surface type bakelite 65x50mm three terminal complete all as specified and directed.
S&F modular Switch piano flush type single pole one way 6 amps complete all as specified & directed.
S&F modular socket outlet 2 in 1, 3 pin, 2 module 6 Amps flush type universal complete all as specified & directed.
S&F modular Switch piano flush type single pole one way 16 amps complete all as specified & directed.
S&F modular Socket out let 2 in one, 5/3 pin 5 & 16 Amp 2 module complete all as specified & directed
S&F fan regulator, modular type, 5 stepped, 120 W, single phase 230 volt including connection complete all as specified & directed.
S&F Modular metal flush box of 6 module complete all as specified & directed
S&F Modular metal flush box of 4 module complete all as specified & directed
S&F Modular metal flush box of 3 module complete all as specified & directed
S&F Modular white cover plate with frame of 6 module complete all as specified & directed
S&F Modular white cover plate with frame of 4 module complete all as specified & directed.
S&F Modular white cover plate with frame of 3 module complete all as specified & directed
S&F in replacement of A C starter unit consisting of one 25 Amp capacity starter, One 240 V 25 Amp 10 KA SPN MCB, one 25 Amp socket and one 25 amp plug top prewired complete all as specified and directed. Make: Havells cat part No. DHDUCDP0253016-25 or Equivalent make as specified in P.S
Taking down existing old /worn out tube/CFL/bulk head/sketch light fittings of indoor type fixed on wall of any type/size with its all accessories including lamp complete all as specified & directed
S&F in replacement of LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver with suitable size of wire complete including connecting with three core flexible copper conductor cable of suitable size complete all as specified by Engr-in-charge
S&F in replacement of existing worn out LED with 10 W mirror light fitting, 2 feet with high output with opal diffuser 230 V AC decorative type with driver holder and LED lamp including connecting with three core flexible copper conductor cable of suitable size complete all as specified.
S&F LED light fitting 1 x 20 watt , 220 volt, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size complete all as specified.
Supply and fixing in replacement LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection bracket for street light made out of 40 mm bore GI pipe medium grade not less than 1.2 mtr length bent at 120 degree to shape fixed on pole/wall with and including 50x6mm FI clamps = 02 Nos with nut bolts, washers including painting of clamps with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
Taking down ceiling fan & cable end, dismantling blades and removing fan and blades, oiling, greasing and painting of ceiling fans complete apply one coat of synthetic enamel paint by spraying including filling cavities with filler after cleaning of all dust etc. and repair/ rewinding with super enameled copper winding wire of existing gauge/ weight of copper coil, quick varnishing, oiling, greasing insulating materials including replacement of worn out parts like u/s cotter pin, nut, screw, check nuts and bolts as required and complete cleaning of body & testing and re-hanging to the same hook and connecting up including provision of cable from ceiling rose to fan complete all as specified and directed. Note - (i) Fans to be collected by the contractor at their own arrangement from AGE E/M store for repair/rewinding and to be deposited at same place after making serviceable duly tested. (ii) Cost of spare parts as required to make the fan serviceable are deemed to be included in the quoted rate.
Supply and fixing in replacement of factory made epoxy polyester powder coated distribution board SP & N 8 way fabricated from minimum 1.6 mm thick CRCA sheet with metal double door (IP-43 protection ) fixed flush to wall and suitable for universal mounting and including copper bus bar, Neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with knockouts and suitable for one DP MCB as incomer and 6 SP MCBs as outgoings complete all as specified and conforming to IS: 8623 along with cable end box for above DB all as specified and directed. NOTE (a) MCBs shall be measured and paid separately. (b) All cables terminating into MCBs shall be connected by using suitable copper lugs/thimbles/sleeves and its cost shall be deemed to be included under respective item of Sch.
Supply and fixing in replacement of factory made epoxy polyester powder coated distribution board SP & N 12 way fabricated from minimum 1.6 mm thick CRCA sheet with metal double door (IP-43 protection ) fixed flush to wall and suitable for universal mounting and including copper bus bar, Neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with knockouts and suitable for one DP MCB as incomer and 8 SP MCBs as outgoings complete all as specified and conforming to IS: 8623 along with cable end box for above DB all as specified and directed. NOTE (a) MCBs shall be measured and paid separately. (b) All cables terminating into MCBs shall be connected by using suitable copper lugs/thimbles/sleeves and its cost shall be deemed to be included under respective item of Sch.
Supply and fixing in replacement of factory made epoxy polyester powder coated distribution board TP & N 4 way (VTPN MCCB DB) with metal double door (IP-43 protection) fabricated from minimum 1.6 mm thick CRCA sheet and fixed on wall and suitable for universal mounting and including 200 Amps copper bus bar, Neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with provn for DPX 160, 4 pole MCCB and ELM as incommer and 16 SP MCBs outgoings complete all as specified and conforming to IS: 8623 along with cable end box for above DB all as specified. NOTE :- (a) MCBs shall be measured and paid separately. (b) All cables terminating into MCBs shall be connected by using suitable copper lugs/thimbles/sleeves and its cost shall be deemed to be included under respective item of Sch.
S&F in replacement of MCB double pole, 40 - 63 amps rating, 240 volts, 50 Hz AC made from moulded self extinguishing thermostate plastic and suitable for 10 KA breaking capacity & making connection complete all as specified and directed.
S&F in replacement of MCB single pole, 6 to 32 amps rating, 240 volts, Hz AC made from moulded self extinguishing thermostate plastic and suitable for 10 KA breaking capacity & making connection complete all as specified and directed.
Supply and fix in replacement of MCCB 100 Amp 4 pole 16 KA at 415 V fixed type complete all as specified and directed.
M &L for Earthing complete with GI earth plate electrode 600x600x6mm thick buried directly in ground (Earth pit not less than 2.25M deep below normal ground level) with top edge of the plate not less than 1.5m below normal GL. Connected to galvanized earth lead wire 4mm dia by means of nut, bolt, check nut and washers including necessary excavation and earth work in soft/loose soil, GI protection pipe light grade 15mm bore for protecting the GI wire mesh funnel alternate layer of charcoal dust, and salt PCC pit 1:3:6 type C1 using 20mm graded stone aggregate and 50mm thick RCC 1:2:4 type B-0 using 20mm graded stone aggregate cover re-inforced with 8 mm dia MS TMT bars 80mm C/C both ways complete all as specified and shown in Electrical plate No.3 SSR part-1 and connected to the earth point and testing complete all as specified and directed.
Schedule of Credit (MINUS) Rs. 146535.00 B/F from Serial Page No. [Note : Details of items for schedule of credit is given on Srl Page No. ] This amount shall be automatically deducted to arrive at tendered sum
Siddhi Constructionn (BID ID -3120573)
Channa Brothers and Co. (BID ID -3121007)
JMD Enterprises (BID ID -3119103)
KHALSA BUILDER (BID ID -3108151)
M/S JAI DURGA CONSTRUCTION (BID ID -3107076)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .