| Sl No | Description | Qty | Unit | M/s Evergreen Electrical Works L3 | M/s. Sahida Electrical Works L1 | UNIVERSAL PROJECT AND MAINTENANCE L2 |
|---|---|---|---|---|---|---|
| 1.00 | Providing of HRC Fuse Link (Power) for Short Circuit Protection of Rating 315A, DIN Type for 415V,90KW submersible pump starter. | 3 | Nos. | 900 ₹2,700 | 555 ₹1,665 Lowest | 650 ₹1,950 |
| 2.00 | Providing of MCB , SP-MCB-10KA "C" Curve for Control Circuit Protection of Rating 6A for 415V,90KW & 550V,180KW submersible pump starter. | 6 | Nos. | 200 ₹1,200 | 129 ₹774 Lowest | 160 ₹960 |
| 3.00 | Providing of C.T Operated Thermal Magnetic Overload Relay for Overload Protection of Range 90-150A for 415V,90KW submersible pump starter. | 2 | Nos. | 7,000 ₹14,000 | 3,987 ₹7,974 Lowest | 5,000 ₹10,000 |
| 4.00 | Providing of Voltage Sensing Single Phase Preventor of Rating-600V for 415V,90KW & 550V,180KW submersible pump starter. | 2 | Nos. | 6,000 ₹12,000 | 5,135 ₹10,270 | 5,000 ₹10,000 Lowest |
| 5.00 | Providing of Electronic Earth Leakage Relay with CBCT Test-Reset Push Buttun and Visual Indication on ELR.E/L Protection (ELR Door Mounting) of Rating-415V and Range 0.5A-2.5A for 415V,90KW & 550V,180KW submersible pump starter. | 2 | Nos. | 15,000 ₹30,000 | 9,009 ₹18,018 | 8,000 ₹16,000 Lowest |
| 6.00 | Providing of CT Ring Type tape insulated of Rating-15VA, Class-1 Accuracy, 200/5A for Ammeter for 415V,90KW submersible pump starter. | 6 | Nos. | 1,500 ₹9,000 Lowest | 1,716 ₹10,296 | 1,500 ₹9,000 Lowest |
| 7.00 | Providing of 96sqmm. Analog Moving Iron CT operated six time suppressed scale Ammeter of Rating-0-200-1200/5A for 415V,90KW submersible pump starter. | 2 | Nos. | 1,200 ₹2,400 | 907 ₹1,814 Lowest | 1,500 ₹3,000 |
| 8.00 | Providing of 96sqmm. Analog Moving Iron Voltmeter of Rating-0-600V for 415V,90KW & 550V,180KW submersible pump starter. | 2 | Nos. | 1,200 ₹2,400 | 907 ₹1,814 Lowest | 1,050 ₹2,100 |
| 9.00 | Providing of Ammeter Selector Switch of Rating-6A for 415V,90KW & 550V,180KW submersible pump starter. | 2 | Nos. | 800 ₹1,600 | 481 ₹962 Lowest | 600 ₹1,200 |
| 10.00 | Providing of Voltmeter Selector Switch of Rating-6A for 415V,90KW & 550V,180KW submersible pump starter. | 2 | Nos. | 800 ₹1,600 | 481 ₹962 Lowest | 600 ₹1,200 |
Tender Value
₹9.6 L
EMD Value
₹12,000
Closing Date
18 May 2026, 5:00 pmClosed
SO EnM LINGARAJ AREA
OFFICE OF THE GENERAL MANAGER LINGARAJ AREA, AT/PO- DEULBERA COLLIERY, DIST- ANGUL, ODISHA, 759102
Repair, Maintenance and Overhauling of 2 Nos. Pullen Make 800GPM, 415V, 90KW and 1 No. 1000GPM, 550V, 180KW Submersible Starter and 1 No. 630KVA 3.3KV/440V Transwitch of Make- Electrotecknika installed at Deulbeda Pit Top W.r.t. IWSS, Lingaraj Area
2026_MCL_359067_1
GM/LA/SO/EnM/e-Ten/26-27/10 DT-05.05.2026
Open Tender
Electrical and Maintenance Works
Item Rate
45 days
IWSS, LINGARAJ AREA
AS PER NIT
5 documents required · 5 mandatory
₹12,000
28 Jul 2026
5 May 2026
20 May 2026
6 May 2026
18 May 2026
6 May 2026
6 May 2026 - 11 May 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Providing of HRC Fuse Link (Power) for Short Circuit Protection of Rating 315A, DIN Type for 415V,90KW submersible pump starter. | 3 | Nos. | 1,068 | ₹3,204 |
| 2 | Providing of MCB , SP-MCB-10KA "C" Curve for Control Circuit Protection of Rating 6A for 415V,90KW & 550V,180KW submersible pump starter. | 6 | Nos. | 249 | ₹1,494 |
| 3 | Providing of C.T Operated Thermal Magnetic Overload Relay for Overload Protection of Range 90-150A for 415V,90KW submersible pump starter. | 2 | Nos. | 7,669 | ₹15,338 |
| 4 | Providing of Voltage Sensing Single Phase Preventor of Rating-600V for 415V,90KW & 550V,180KW submersible pump starter. | 2 | Nos. | 9,875 | ₹19,750 |
| 5 | Providing of Electronic Earth Leakage Relay with CBCT Test-Reset Push Buttun and Visual Indication on ELR.E/L Protection (ELR Door Mounting) of Rating-415V and Range 0.5A-2.5A for 415V,90KW & 550V,180KW submersible pump starter. | 2 | Nos. | 17,325 | ₹34,650 |
| 6 | Providing of CT Ring Type tape insulated of Rating-15VA, Class-1 Accuracy, 200/5A for Ammeter for 415V,90KW submersible pump starter. | 6 | Nos. | 3,300 | ₹19,800 |
| 7 | Providing of 96sqmm. Analog Moving Iron CT operated six time suppressed scale Ammeter of Rating-0-200-1200/5A for 415V,90KW submersible pump starter. | 2 | Nos. | 1,746 | ₹3,492 |
| 8 | Providing of 96sqmm. Analog Moving Iron Voltmeter of Rating-0-600V for 415V,90KW & 550V,180KW submersible pump starter. | 2 | Nos. | 1,746 | ₹3,492 |
| 9 | Providing of Ammeter Selector Switch of Rating-6A for 415V,90KW & 550V,180KW submersible pump starter. | 2 | Nos. | 926 | ₹1,852 |
| 10 | Providing of Voltmeter Selector Switch of Rating-6A for 415V,90KW & 550V,180KW submersible pump starter. | 2 | Nos. | 926 | ₹1,852 |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Tendernotice_1.pdf
PDF • 1.75 MB
Tendernotice_2.pdf
PDF • 1.18 MB
BOQ_371937.xls
BOQ • 0.31 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .