Tender Value
₹4.0 Cr
EMD Value
₹3.5 L
Closing Date
22 Dec 2025, 3:00 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
Above/Below/Par
WORKS
13 conditions · 2 needing a document upload
The tender is more than 50 lakhs and eligibility criteria is applicable. The firm has to submit the Annexure VIB along with relevant documents i.e Profit and loss statement and Balance sheet duly signed by CA and all the terms and conditions as per GCC 2022 with latest amendments.
The tender is more than 50 lakhs and eligibility criteria is applicable.
4 conditions
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Consignee of the tender :- SSE(SIG)Nagpur Maintenance Period:- 12 Months PVC clause in not applicable.
Improvement in earthing & surge protection arrangements for S&T equipment's for improving reliability of the S&T gears over Nagpur Division
56-2025-NGP-SNT-EARTHING~CR
56-2025-NGP-SNT-EARTHING
Open
Works - General
11 Months
Nagpur, Maharashtra
₹0
₹3.5 L
22 Dec 2025
26 Nov 2025
8 Dec 2025
83 items across 3 schedules
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 1,41,64,039.52 | ||
| — | 6.00 | — | — | ||
| Supply of PVC flexible copper cable single core multistrand 1 x 10 Sq.mm (80 conductor each diameter 0.40 +/- 0.01) as per IS 694/2010 with latest amendment if any.with insulation thickness of 1.0mm nominal conductor resistance 1.91 ohms/Km and test parameters are as per IRS (S)76/89 (Amd.3).(Insp Agency-RDSO) | — | — | — | 7,43,557.92 | |
| — | 6.00 | — | — | ||
| Supply of PVC flexible copper cable single core multistrand 1 x 16 Sq.mm (126 conductor each diameter 0.40 +/- 0.01) as per IS 2465/1984 & IS:694/2010 with latest amendment if any with insulation thickness of 1.0mm nominal conductor resistance 1.121 ohms/Km and test parameters are as per IRS (S)76/89 (Amd.3).(Insp Agency-RDSO) | — | — | — | 11,06,583.18 | |
| — | 2.00 | — | — | ||
| Supply of PVC flexible copper cable single core multistrand 1 x 25 Sq.mm (196 conductor each diameter 0.40 +/- 0.01) as per IS 2465/1984 & IS:694/2010 with latest amendment if any with insulation thickness of 1.2mm nominal conductor resistance 0.780 ohms/Km and test parameters are as per IRS (S)76/89 (Amd.3).(Insp Agency-RDSO) | — | — | — | 5,21,554.9 | |
| — | 58.00 | — | — | ||
| A CLASS EARTHING- Supply of ESR ALTEC TERRA STREAMER Lightnig Arrester with SS adaptor (TSP30, 50 Mtr. Radius) SPN: NFC-17-102-2011. (Insp Agency-Consignee) | — | — | — | 36,46,868.32 | |
| — | 58.00 | — | — | ||
| Supply of FRP Mast with GI Mast (FRP mast at top minimum 1.5 Mtr. along with GI mast 3 Mtr.) Total 4-5 Mtr. Std mast required for mounting the terminal & adaptor to mount the Air terminal with coupler/ reducer. Multi strand stray wires, joints, clamps & accessories as per IS 2309:1989. (Insp Agency-Consignee) | — | — | — | 5,43,205.38 | |
| — | 58.00 | — | — | ||
| Supply of Test Link Joint Kit in a IP65 weather proof enclosure of suitable dimension and approved make & desig.(Insp Agency-Consignee) | — | — | — | 1,39,744.04 | |
| — | 58.00 | — | — | ||
| Supply of Lightning Strike Recorder LSC 6 digit shall be weather proof type. It should have 6 digit event count & the capacity to count smallest strike (3KA). It should be voltage sensing type counter. So that it will register nearby strikes & static discharge due to induction effect as per IS 2309:1989. (Insp Agency-Consignee) | — | — | — | 8,55,375.88 | |
| — | 1160.00 | — | — | ||
| Supply of Down Conductor (recommended:70 Sqmm 19 strand copper insulated cable for lightning current dissipation to earth with necessary fixing clamp, connector accessories etc.) (Insp Agency-Consignee) | — | — | — | 4,99,090 | |
| — | 40.00 | — | — | ||
| Maintenance Free Earth as per RDSO/SPN.197/ 2008 or latest consisting of : 1) Copper bond steel electrode 3 Mtr long 17mm dia with copper bonding thickness of min. 250 micron & UL listed & marked-01 No. 2) Earth enhancement compound RDSO Approved in sealed bag of 10 Kgs - 03 No. 3) Copper strip 150 x 25 x 6mm - 02 No. 4) Copper strip 300 x 25 x 6mm - 01 No. 5) 35 Sqmm Copper Cable to connect earth electrode to MEEB - 15 Mtr Approx. (Insp Agency-RDSO) | — | — | — | 5,90,288.4 | |
| — | 1800.00 | — | — | ||
| Supply of 35 Sq.mm Multistrand Single Core PVC Insulated Copper for connecting earth bus bar to earth electrode. (Insp AGency-Consignee) | — | — | — | 7,31,394 | |
| — | 3000.00 | — | — | ||
| Supply of Copper Tape 25x6 mm (Bonding ring conductor) mounted on insulated standoff (1 round).(Insp AGency-Consignee) | — | — | — | 23,86,200 | |
| — | 10.00 | — | — | ||
| Supply of Microprocessor based universal earth resistance sensing unit 12 channel AC/DC as per RDSO/SPN/256/2002 with latest amendments. (Insp Agency-RDSO) | — | — | — | 10,99,412.5 | |
| — | 10000.00 | — | — | ||
| Supply of PVC jacketed wire rope for Track Lead connections. PVC jacketed wire rope should be of Galvanised steel wire rope 6 mm dia (6x19 stranded wire with steel core of 6 mm dia) sheathed with PVC 2mm wall thickness, overall thickness being 10 mm. PVC sheath should be made of type 6 compound as per IS 5831 of 1984 Reaffirmed 2001 and steel wire rope as per IS: 2266:2019. Reclaimed or recycled material should not be used. (Insp Agency-Consignee) | — | — | — | 4,33,900 | |
| — | 10000.00 | — | — | ||
| Supply of 8 SWG GI wire (4mm dia) suitable for track circuit rail bonding. As per IRS Specification S:13@45>46@ (Insp Agency-Consignee) | — | — | — | 7,20,400 | |
| — | 500.00 | — | — | ||
| Supply of Paints as per relevant IS specification preferably Asian/ Apcolite/Dulux make in different colours in 1 Kg/2 Kg pack (Insp AGency-Consignee) | — | — | — | 1,46,465 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .