| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹1.3 CrAdmitted-Finance | -23.58% | ₹1.3 Cr | L1 | Admitted-Finance |
| 2 | L2₹1.3 Cr+₹1.8 L (1.37%)Admitted-Finance | -22.53% | ₹1.3 Cr+₹1.8 L (1.37%) | L2 | Admitted-Finance |
| 3 | L3₹1.5 Cr+₹16.5 L (12.4%)Admitted-Finance | -14.11% | ₹1.5 Cr+₹16.5 L (12.4%) | L3 | Admitted-Finance |
| 4 | L4₹1.6 Cr+₹23.3 L (17.5%)Admitted-Finance | -10.21% | ₹1.6 Cr+₹23.3 L (17.5%) | L4 | Admitted-Finance |
| 5 | L5₹1.7 Cr+₹32.3 L (24.3%)Admitted-Finance | -5.00% | ₹1.7 Cr+₹32.3 L (24.3%) | L5 | Admitted-Finance |
Tender Value
₹1.7 Cr
EMD Value
₹3.5 L
Closing Date
16 Feb 2026, 6:00 pmClosed
Xen PHED Begun
Xen PHED Begun
NIT No 99/2025-26
2026_PHCJA_534515_1
NIT No 99/2025-26
Open Tender
Civil Works
Percentage
270 days
Begun
Tender Documnets
5 documents required · 5 mandatory
₹2,000
Secretary, RREIS
₹3.5 L
Yes
20 Feb 2026
2 Feb 2026
17 Feb 2026
2 Feb 2026
16 Feb 2026
2 Feb 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Construction of Tube Well up to 100 mtr. depth in all type of rocks by DTH system & over burden to accommodate casing pipe of following sizes in all types of soils & over burden including lowering of casing pipes, (if required) excluding cost of casing pipes, as per IS:2800 Part 1: 1991 and IS:2800 Part II: 1979 (both amended up to date) and technical specifications. The work would be completed after obtaining sand free water. The tube well should have a through out bore as per nominal dia of casing pipe. | - | - | - | - |
| 2 | Nominal bore 200 mm dia.( for 3 nos tw -> 100*3=300) | - | Mtr | 1,089 | - |
| 3 | Add 15% extra on above item (Item No 2.4.1 to 2.4.2) for drilling depth beyond 100 mtr and up to 200 mtr from ground level, rate shall be applicable for only extra depth beyond 100 mtr and up to 200 mtr. (for 3 no's tw -> 80*3=240) | - | Mtr | - | - |
| 4 | Supply of ERW M.S. black casing pipe ISI marked (IS: 4270/2001) or amended up to date of following sizes | - | - | - | - |
| 5 | 200 mm dia NB (Thickness of pipe 5.4mm & mass of tube 28.46 Kg/m) (for 3 nos tw -> 15*3=45) | - | Mtr | 2,734 | - |
| 6 | Supply & Installation of 3 phase ISI marked submersible motor pump set of three star or better rating of BEE and as per IS: 8034-2018 (pump) and IS 9283-2013 (motor) or as amended up to date of approved make of following duty condition with required accessories including making connection suitable for tube well/DCB. The job includes lowering of motor pump, installation of complete fitting & accessories, jointing of electrical cables up to switch board, testing of submersible pump set and interconnection up to water mains, complete in all respect. | - | - | - | - |
| 7 | Up to 5.5 KW (7.5 HP) & head above 120 mtr.(for 3 no's tw -> 5.5*3=16.5 ) | - | KW | 9,628 | - |
| 8 | Supply and Fixing of electric control feeder panel comprising of suitable rating MCCB , fully automatic star-delta starter, over load relay, ampere meter with CTs, volt meter, phase preventer, suitable starting capacitors, phase indicators, lighting arrangement etc. complete suitable for three phase pump set. The panel should have space for energy meter ( supplied by DISCOM). All these equipments shall be housed by panel box made out from 18 gauge M.S. Sheet with powder coating. Panel should be of minimum size 900 x 600 x 450 mm with Stand ( made of angle iron of size 35x35x5mm) duly bolted/screwed with enclosure box having 4 legs, each leg’s length 18" and double door including in built locking system. The legs should be embedded in M-15 cement concrete plat form. The size of CC platform should be equal or bigger than the base size of panel having height of at least 200 mm from ground level. The panel should have opening of suitable size in front of space for energy meter with glass for meter reading. The operation of panel should be suitable for on 440 Volt AC Supply. | - | - | - | - |
| 9 | Above 5 HP and up to 10 HP (for 3 no's tw -> 1*3 = 3 ) | - | Each | 24,273 | - |
| 10 | Supply & Fixing of ISI marked three core PVC flat submersible cable as per IS 694:1990 or amended up to date and conductor as per class 5 of IS 8130:1980 including making connection etc. | - | - | - | - |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.96 MB
FinalTDBegun.pdf
Tender Documents • 5.60 MB
BOQ_952412.xls
BOQ • 0.39 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .