| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.3 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹12.5 L+₹12,850 (1.04%)Rejected-AOC | L2 | Rejected-AOC Rejected | |
| 3 | L3₹12.6 L+₹18,700 (1.51%)Rejected-AOC | L3 | Rejected-AOC Rejected | |
| 4 | L4₹12.6 L+₹21,450 (1.73%)Rejected-AOC | L4 | Rejected-AOC Rejected | |
| 5 | L5₹13.5 L+₹1.1 L (8.94%)Rejected-AOC | L5 | Rejected-AOC Rejected |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
27 Aug 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF SRINAGAR
GE AF SRINAGAR 190007
REPAIR / MAINTENANCE OF ELECTRIFICATION SYSTEM AT VARIOUS INSTALLATION AND AREA UNDER GE (AF) SRINAGAR.
2021_MES_461884_1
GE (AF) - 31/2021-22
Open Tender
Civil Works
Item Rate
180 days
GE AF SRINAGAR
Please refer Tender documents.
10 documents required · 10 mandatory
₹500
GE AF SRINAGAR
₹40,000
Yes
22 Sept 2021
22 Jul 2021
28 Aug 2021
22 Jul 2021
27 Aug 2021
14 Aug 2021
60 days
Amount
Excavation in trenches n.exc 1.5 M wide and n.exc 1.5 M depth and getting out for laying of underground cable etc in any type of soil complete all as specified and directed Engineer-in-Charge.
Returning, filling in, including spreading, levelling watering and well ramming in layers n.exc 25 cm thick in any type of soil complete all as specified and directed by Engineer-in-Charge.
Removing of excavated soil to a distance n.exc 50 metre and depositing where directed at a level not exceeding 1.5 m above the starting point, complete all as specified and directed Engineer-in-Charge.
M&L for cutting of existing road surfaces up 100 mm deep & 300 mm wide and making good disturbed portion with 100mm thick plain cement concrete 1:2:4 type B-1 (using 40mm graded crushed stone aggregate) complete all as specified and directed by Engineer-in-Charge.
M&L for dry & clean sand cushioning in trenches spreading and consolidation 8 cm thick before laying the cable and 15 cm of sand after laying the cable and punned the same up to 18 cm complete all as specified and directed by Engineer- in-Charge. Note:- Only punned thickness shall be measured and paid.
S&F 80 mm dia bore mild steel galvanized iron tubes, 'light grade' with all fitting and laid in trenches or fixed to pole or laid in floors for protection of cable complete all as directed.
S&F 50 mm dia bore mild steel galvanized iron tubes, 'light grade' with all fitting and laid in trenches or fixed to pole or laid in floors for protection of cable complete all as directed.
Taking out carefully unserviceable LT under ground cable of following size from trenches / Pipes including taking out bricks, complete all as specified and as directed by Engineer-in-Charge. (Serviceable Bricks obtained shall be cleaned and stacked properly for reuse)
16 sqmm 4 core to 50 sqmm 3.5 core
70 Sqmm 3.5 core to 120 sqmm 3.5 core
Laying only XLPE insulated, PVC inner sheathed, armoured, LT underground cable of following size laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing etc complete all as specified & directed. Note:- (i) Cable will be issued under Sch 'B' Free for laying. (ii) Earthwork, sand cushion, cable cover if required will be measured and paid separately under respective items of this Schedule.
16 sqmm 4 core to 50 sqmm 3.5 core
70 Sqmm 3.5 core to 120 sqmm 3.5 core
Supply and Laying of bricks well burnt sub class B (old size) laid flat for cable protection width equal to the length of bricks complete all as specified and directed by Engineer-in-Charge.
Laying Only of bricks retrieved from items no. 8 here-in-before laid flat for cable protection width equal to the length of bricks complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of old painted steel surface of LT feeder pillar Box, 440 Volts, 3 phase of any size / location and applying two coats of synthetic enamel paint complete all as specified and directed Engineer-in-Charge.
Material and labour for renewal of earthing complete with galvanized iron earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m deep below normal ground, surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 150mm on all side, earth plate connected to galvanized steel strip of size 25 mm x 4 mm by means of bolts nuts check nuts and washer of galvanized steel, watering pipe of 20 mm bore, light grade, and 32 mm bore galvanised iron light grade pipe for earth wire protection including all excavation earth work in any type of soil, PCC pit in PCC 1:2:4 type B-1 and RCC 1:2:4, type B1 for precast chamber cover 50 mm thick, reinforced with welded steel wire fabric or XPM Jali (weight not less than 4.00 Kg / Sqm), including funnel complete all as shown in the electrical plate No 3 of SSR part –I and testing on completion.
Material and labour for renewal of earthing complete with copper earth plate electrode 600 mm x 600 mm x 3.15 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m deep below normal ground, surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 150 mm on all side, earth plate connected to copper strip of size 20 mm x 3 mm by means of bolts nuts check nuts and washer of galvanized steel, watering pipe of 20 mm bore, light grade, and 25 mm bore galvanised iron light grade pipe for earth wire protection including all excavation earth work in any type of soil, PCC pit in PCC 1:2:4 type B-1 and RCC 1:2:4, type B1 for precast chamber cover 50 mm thick, reinforced with welded steel wire fabric or XPM Jali (weight not less than 4.00 Kg / Sqm), including funnel complete all as shown in the electrical plate No 3 of SSR part –I and testing on completion.
S&F in repairs LED street Light fitting 60 Watt, system efficiency not less than 110 lumen / watt, IP66 protection, consisting of high / low voltage cut off, maintenance free isolated Electronic driver circuits, Low THD, PMMA grade high quality Transmittance lens, Epoxy powder coated Die Cast Aluminium housing with weather proof gasket for lamp & driver compartment, fitted in cast aluminium housing with SS screws fixed on existing bracket & connecting, complete.
S&F in repair LED flood Light fitting 100 Watt, system efficiency not less than 100 lumen / watt, IP65 protection, consisting of high / low voltage cut off, maintenance free isolated Electronic driver circuits, Low THD, PMMA grade high quality Transmittance lens, Epoxy powder coated Die Cast Aluminium housing with weather proof gasket for lamp & driver compartment, Heat resistance toughened glass fitted in cast aluminium housing with SS screws fixed on existing bracket & connecting, complete.
Supply and filling transformer oil confirming to IS-335183 having dielectric strength upto 50 KV at 4 mm gap for topping up in transformer complete.
Supply and fix in repair out door, triple pole, gang operated switch single bank, tilting type suitable to vertical / horizontal mounting consisting of hot dipped electro plated galvanised channel iron base with drop out fuse having 12 Nos insulators 11 KV, copper alloy tinned contacts, copper or chromium plated MS arcing chains, capable of making and breaking the magnetising current complete with horizontal bar, GI pipe as down level, coupling and operating handle with locking arrangements and drop out fuses working voltage 11000 volts 200 Amps including testing complete all as specified and as directed by Engr-in-Charge.
M&L for painting of steel tubular poles(perimeter) approximately 5/5.5 meter above GL in height including cross arms and bracings with two coat of aluminium paint painting paint incl numbering of the pole complete all as specified and directed.
Labour only for maintenance of gang operated air break isolators switch out door type 9 / 12 insulators double stack, triple pole, rotating type double break per pole for 11000 volts, 3 phase, 50 Hz, AC supply system having 200 / 400 Amps capacity by oiling, greasing, adjustment of lever and making the same smooth functional complete all as specified.
Supply and fix in repairs of male contact / moving contact blade made out of brass alloy, spasre for gang opertated air break switches 11 KV, 200 Amps complete all as specified.
Supply and fix in repairs of female contact / fixed contact blade made out of brass alloy, spsare for gang operated air break switches 11 KV, 200 Amps completge all as specified.
S&F in repair lightening arressters explusion type complete with all fittings, transmisson class, discharge capacity 65 kA, 11000 Volts.
S&F in repair Danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white, with letters, in English and / Hindi figures and conventional skull and bones in signal red colour and fixed with M.S clamps, bolts and nuts of size, HT, 25 x 20 cm.
Supply and erect in true vertical position 9.00 metre long steel tubular swaged poles complete with cast iron base plate, finial plug, bolts, nuts & screws as specified type 410 SP-31, painting of exposed surface of pole with two coats of aluminium paint over one coat of red oxide primer, painting up to 1.20 meter height above coping in alternate band ( 20 cm wide strip) with two coat synthetic enamel paint over one coat red oxide primer, marking Pole No. in 10 cm dia coloured yellow circle, painting of pole below ground level with two coat anticorrosive paint including taking down old swaged pole complete all as specified & directed. Note:- Excavation, earth work and PCC will be measured and paid separately.
Supply and erect in true vertical position 11.00 metre long steel tubular swaged poles complete with cast iron base plate, finial plug, bolts, nuts & screws as specified type 410 SP-55, painting of exposed surface of pole with two coats of aluminium paint over one coat of red oxide primer, painting up to 1.20 meter height above coping in alternate band ( 20 cm wide strip) with two coat synthetic enamel paint over one coat red oxide primer, marking Pole No. in 10 cm dia coloured yellow circle, painting of pole below ground level with two coat anticorrosive paint including taking down old swaged pole complete all as specified & directed. Note:- Excavation, earth work and PCC will be measured and paid separately.
M&L for PCC (1:3:6) Type C-2 (Using 40 mm grade crushed stone aggregate as in foundation of pole, stay and filling and mass concrete) including providing necessary form work complete all as specified and directed
M&L for for PCC (1:2:4) type B-1 using 20 mm grade crushed stone aggregate as in copping of electric pole at site including providing necessary form work complete all as specified and directed.
Supply & fix Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one coat red oxide primer, two coats aluminium paint including taking down old cross arm complete.
Supply and fix in repair Cable end termination heat shrinkable jointing kit indoor type suitable for HT cable (earthen grade) XLPE insulated aluminium conductor of size 120 Sqmm 3 Core complete all as specified and as directed by Engr-in-Charge.
Supply and fix in repair heat shrinkable jointing kit straight through type suitable for HT cable (earthen grade) XLPE insulated aluminium conductor of size 120 Sqmm 3 Core complete all as specified and as directed by Engr-in-Charge.
Supply and fix in repair heat shrinkable jointing kit straight through type suitable for HT cable (earthen grade) XLPE insulated aluminium conductor of size 95 Sqmm 3 Core complete all as specified and as directed by Engr-in-Charge.
Supply and fix in repair Cable end termination heat shrinkable jointing kit outdoor type suitable for HT cable (earthen grade) XLPE insulated aluminium conductor of size 95 Sqmm 3 Core complete all as specified and as directed by Engr-in-Charge.
Supply and fix in repair Cable end termination heat shrinkable jointing kit outdoor type suitable for HT cable (earthen grade) XLPE insulated aluminium conductor of size 120 Sqmm 3 Core complete all as specified and as directed by Engr-in-Charge.
M/S NEW FAROOQ TRADERS
M/s GHULAM NABI HAJAM
M/s Alam-i-Afroz
M/S TARIQ AHMAD SHEIKH
M/S KHAN ENTERPRISES
yattoo contractors
CHINAR CONSTRUCTION TRADERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .