| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.9 CrAccepted-AOC 4TH FLOOR VOLTAS HOUSE A BLOCK DR BABASAHEB AMBEDKAR ROAD CHINCHPOKLI MUMBAI MAHARASHTRA 400033 | MUMBAI | MAHARASHTRA | 400033 | ₹1.9 Cr | L1 | Accepted-AOC Accepted |
| 2 | L2₹2.1 Cr+₹22.0 L (11.6%)Rejected-Finance | ₹2.1 Cr+₹22.0 L (11.6%) | L2 | Rejected-Finance Quoted Higher Rate |
| 3 | L3₹2.3 Cr+₹40.9 L (21.6%)Rejected-Finance 11TH FLOOR ECO CENTRE BUSINESS TOWER P NO 4 EM BLOCK SECTOR V KOLKATA 91 | KOLKATA | 24 PARAGANAS NORTH | WEST BENGAL | 700091 | ₹2.3 Cr+₹40.9 L (21.6%) | L3 | Rejected-Finance Quoted Higher Rate |
| 4 | L4₹2.3 Cr+₹45.7 L (24.1%)Rejected-Finance | ₹2.3 Cr+₹45.7 L (24.1%) | L4 | Rejected-Finance Quoted Higher Rate |
Tender Value
Refer Docs
EMD Value
₹4 L
Closing Date
13 Nov 2019, 2:00 pmClosed
SE,HEC,PWD
SUPERINTENDING ENGINEER (P.W.D) Health Electrical Circle KIT Annex Building, 5th FLOOR, KOLKATA 700073
Rehabilitation of distressed concrete rof Floor / Roof and some necessary allied works to David Hare Building (EI as well as AC System) within the compound of MCH, Kolkata. --- AC work.
2019_WBPWD_248622_1
WBPWD/SEHEC/NK/NIQ01/19-20/3rd
Open Tender
ELECTRICAL WORKS ORG
Item Rate
180 days
Medical Collage and Hospital
Please refer Tender documents.
4 documents required · 4 mandatory
₹4 L
Office of the SE,HEC,PWD
1 Dec 2020
16 Oct 2019
15 Nov 2019
17 Oct 2019
13 Nov 2019
25 Oct 2019
24 Oct 2019
Amount
SUB-HEAD A - CHILLER
Supply, Positioning, Starting, Testing & Commsioning of AHRI / Eurovent certified Air Cooled Screw Chiller of capacity stated below at operating condition mentioned below having single/multiple screw compressor driven by suitably rated hermetic / semi hermetic motor complete with all standard accessories. Air cooled condenser with factory coating against corrosion, insulated flooded / Dx chiller, flow switch at chiller outlet, interconnecting insulated refrigerant piping, refrigerant & oil (first charged), micro processor based control panel, 1" deflection screen isolator of suitable capacity all mounted on MS baseplate. Motor shall be suitable for 415V ±10%, 50 Hz ± 5%, 3-Ph AC supply. Operating conditions are furnished below:
Minimum Refrigeration Capacity - 85 TR (Actual) at the following operating conition and AHRI condition (2 Working + 1 Standby)
Refrigerant - 134 A
Chilled Water Inlet Temp - 14.50C
Chilled Water Outlet Temp - 9.0 0C
Ambient Temparature : 40ºC
Fouling factor Evaporator & condenser as per ASHREE and AHRI
IPLV as per latest BEE circular for ECBC buildings.
IKW/TR at design condition shall be as specified by AHRI
Required cushy foot mounting & flexible below arrangement
[Make - As per Approved Make]
SUB-HEAD D- CHILLED WATER PUMP
Supply, Installation, Testing and Commissioning of Back - Pullout Casing Chilled water pump set capable of delivering 255 USGPM of water . duly insulated with 32mm thik Nitrite Rubber , Each comprising of Suitable HP, TEFC Squirrel Cage Induction Motor with class "F" insulation, 1440 rpm synchronous speed, suitable for operatation on 415 ± 10% volts, 3 phase, 50 Hz A.C. supply. The Pump / Motor shall confirm to IE2 Standard and 81.4% Efficiency. 150 mm dia dial type pressure gauges for inlet & outlet, mounted on common MS base plate, complete as per specifications etc. as required. (2 Working + 1 Standby) , The motor shall have IP65, all weather proof, isolator with lockable arrangement.
The item included suitable cush foot mounting arrangement with rubber flexible below.
[Make - As per Approved Make]
SUB-HEAD G - AHU
FLOR MOUNTED AHU
SITC of factory built floor mounted chilled water double skin type horizontal/vertical air handling units made of 25 mm thick panels consisting of preplasticized G.I. casing of thickness 0.8mm outside layer and 0.8 mm inside layer with polyurethane foam (PUF) insulation factory injected between them by injection moulding machine, complete with blower section with blower suitable for static pressure as required, minimum 2 bend GSS/PVC eliminators,cooling coil section with aluminium finned copper tubes (tubes thickness not less than 0.5 mm) cooling coil of 6 row deep, filter section with 50 mm thick metal viscous/ washable synthetic
pre-filter (90% down to 10 micron) and fine filter (95% down to 5 micron), belt drive package with TEFC drive motor of efficiency class IE3 suitable for 415 ± 10% V, 50Hz, 3 Phase AC supply suitably designed for varialbe frequency drive applications including SITC of suitable VFD (Make as per approved Make list) drain connections, stainless steel (18G) drain pan with PUF insulation, 150 mm dia. dial type pressure gauges (2 Nos.)and industrial type thermometres (2 Nos.) at the inlet and outlet of coil, autopurge valve wherever required, necessary vibration isolation arrangement etc. complete as per specification and of following Capacities
[Make - As per Approved Make]
60 MM total Static Pressure
SITC of factory built floor mounted chilled water double skin type horizontal/vertical air handling units made of 43±2 mm thick panels consisting of preplasticized G.I. casing of thickness 0.8mm outside layer and 0.8 mm inside layer with polyurethane foam (PUF) insulation factory injected between them by injection moulding machine, complete with blower section with blower suitable for static pressure as required, minimum 2 bend GSS/PVC eliminators,cooling coil section with aluminium finned copper tubes (tubes thickness not less than 0.5 mm) cooling coil of 8 row deep, filter section with 50 mm thick metal viscous/ washable synthetic
pre-filter (90% down to 10 micron) and fine filter (95% down to 5 micron), belt drive package with TEFC drive motor of efficiency class IE3 suitable for 415 ± 10% V, 50Hz, 3 Phase AC supply suitably designed for varialbe frequency drive applications including SITC of suitable VFD (Make as per approved Make list) drain connections, stainless steel (18G) drain pan with PUF insulation, 150 mm dia. dial type pressure gauges (2 Nos.)and industrial type thermometres (2 Nos.) at the inlet and outlet of coil, autopurge valve wherever required, necessary vibration isolation arrangement etc. complete as per specification and of following Capacities.
The AHU must have frsh air arrangement for recommended capacity with return air and fresh air dampers & mixing chamber, and should have thermal break profile.
[Make - As per Approved Make]
125 mm / 60mm total Static Pressure
3800 CFM with 125mm TSP
3900 CFM with 125mm TSP
4000 CFM with 125mm TSP
64000 CFM with 60mm TSP with 6row deep cooling coil
CEILING SUSPENDED AHU
SITC of factory built ceiling suspended type double skinned chilled water air handling units fabricated out of extruded aluminium section with 0.6mm pre-plasticized / pre coated galvanised steel sheet outside & 0.6mm plane galvanised steel sheet inside with farward curved blower, blower section and blower motor TEFC type suitable for operation on 415 ± 10% V, 50Hz± 5% , 3 Phase AC supply, 6 row cooling coil made of Aluminium finned copper tube with coil section, pre filter section with non woven synthetic media of 10 micron particle size with an efficiency of 90% and fine filter 95% down to 5 micron (fine filter for 60 TSP AHU or Higher), polished stainless steel drain pan made out of 22SWG sheet duly insulated complete with motor , direct / belt drive as mentioned below etc. without face and bypass dampers. All direct driven fan motor shall be sourced from fan manufacturer & factory fitted only.
The AHU panel shall be insulated with 23mm thick & 36 kg/m3 density PU foam. The motor & blower assembly shall be mounted on Aluminium extruded section only. The complete AHU shall conform to standard specification. The face velocity across cooling coil shall be limited to 152 MPM maximum. The supply blower motor shall be VFD operated including SITC of suitable VFD & their necessary control etc as required. The capacity of Air handlers shall be as follows :
[Make - As per Approved Make]
60 MM total Static Pressure
40 MM total Static Pressure
1600 CFM 40MM Total Static Pressure
2000 CFM 40MM Total Static Pressure
3200 CFM 40MM Total Static Pressure
4460 CFM 40MM Total Static Pressure
6500 CFM 40MM Total Static Pressure
VARIABLE AIR VOLUME
Variable air volume box to control the air delivery volume complete with actuator, thermostat, corded remote and linkages. Make - Honeywell / Systemair / JCI / Trane/Diakin/Trox/Johnson
UVC EMITTER.
a) SITC of UVC EMITTER for the above AHU's for prevention of fungus in the chilled water cooling coils. The minimum UV intensity in the coils shall be greater than 1000 UW-SEC/CM2 for OTs. The unit shall be UL Listed (UL-1995) [Make - As per Approved Make]
b) SITC of UVC EMITTER for the above AHU's for prevention of fungus in the chilled water cooling coils. The minimum UV intensity in the coils shall be between 600 to 700 UW-SEC/CM2 for other than Ots. The unit shall be UL Listed (UL-1995) [Make - As per Approved Make]
SUB-HEAD H - CHILLED WATER PIPING SECTION [Make - As per Approved Make]
Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with following closed cell elastometric nitrile rubber of minimum 45 Kg / m3 density, thermal conductivity 0.037 W/MK or better at 20 deg mean temperature class ‘O’ insulation applied by suitable adhesive complete including repairing of damage to building etc. as per specifications and as required complete in all respect. [ Note:-The Pipes of sizes 150 mm & below shall be M.S. ‘C’ class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35 mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above.
200 mm dia. (32 mm thick insulation)
150 mm dia. (32 mm thick insulation)
125 mm dia. (32 mm thick insulation)
100 mm dia. (32 mm thick insulation)
80 mm dia. (32 mm thick insulation)
65 mm dia. (32 mm thick insulation)
50 mm dia. (32 mm thick insulation)
40 mm dia. (32 mm thick insulation)
32 mm dia. (19 mm thick insulation)
25 mm dia. (19 mm thick insulation)
SUB-HEAD H - CHILLED WATER PIPING VALVES & FITTINGS [Make - As per Approved Make]
BUTTERFLY VALVE (MANUAL) with C I body SS Disc, Nitrile Rubber Seal & O- Ring PN 16 pressure rating for chilled water/ hot heater circulation as specified
125 mm dia.
100 mm dia.
80 mm dia.
65 mm dia.
50 mm dia.
40 mm dia.
32 mm dia.
BALANCING VALVE WITH BUILT IN MEASURING FACILITY with C I body flanged construction with EPDM coated disc with long pitch with protected out pipe insulation & PN 16 pressure rating for chilled / hot water circulation as specified.
125 mm dia
100 mm dia.
80 mm dia.
65 mm dia
50 mm dia.
40 mm dia
32 mm dia.
Auto Air Vent with Ball Valve
NON - RETURN VALVE with duel plate of C I body SS plates vulcanized NBR seal flanged end & PN 16 pressure rating for chilled / hot water circulation including insulation as specified.
125 mm dia Each
Y - STRAINER of Ductile CI Body flanged ends with stainless steel strainer for chilled / hot water circulation including insulation as specified.
125 mm dia
S&F of water Flow switch
Providing and fixing in position the industrial type pressure gauges with gun metal / brass valves complete as required
Providing & fixing in position the mercury in glass industrial type thermometres.
3-WAY MIXING VALVE WITH ACTUATOR, LINKAGE & THERMOSTAT The three way modulating valves shall be provided in chilled water line to the cooling coil of Air- handlers which is actuated by a proportionate thermostat. These valves shall consist of bronze metal valve body with stainless steel trim. Modulating motor shall be suitable for operation with a signal of 0-24 volt DC. The pressure drop across valve for air-handler unit shall not exceed 5.0 PSI. The valve linkages shall be of the same make as of valves & modulating motor.
65 mm dia.
50 mm dia.
40 mm dia.
32 mm dia.
25 mm dia.
Supply and installation of 1500 L HDPE Expansion Tank (Mk.Patton/Syntex) along with 1 No Float Valve and 3 Nos isolation valves for necessary connections including thermal insulation work by 75 mm thick Expanded Polystyrene covered with GI Chicken wire mesh, vapour barrier and 12 mm thick sand cement plaster cover
SUB - HEAD I - DUCT WORKS INCLUDE ALL ACESSORIES [Material Make - As per Approved Make]
Supply, installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular/ round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.
Supply, installation, testing and commissioning of Motorized (ON-OFF Type) duct mounted GI volume control damper with enthalpy sensor and necessary control wire (minimum 1.5 sq. mm) for integration within AHU room
Damper
Actuator
Supplying & fixing of powder coated extruded aluminium Supply Air Grills with aluminium volume control dampers as per specifications.
Supplying & fixing of powder coated extruded aluminium Return Air Grills with louvers but without volume control dampers complete as required.
Supplying, fixing testing commissioning of supply air diffusers of powder coated aluminium with aluminium volume control dampers with anti smudge ring & removable core.
Supplying, fixing testing commissioning of Return air diffusers of powder coated aluminium without volume control dampers with anti smudge ring & removable core.
Supplying, Fixing,testing and commissioning of fire dampers in supply air duct/main branch and return air path as and where required of required sizes i/c control wiring,the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal complete as required and as per specifications.
Fire damper
Actuator
Supply and fixing of Opposed blade GI Duct Damper of 18 G GI sheet and frame.
Supplying, fixing, testing & commissioning of powder coated extruded aluminium section fresh air grill in AHU room with aluminium volume control dampers, bird screen etc complete as required.
a) 4.5 kw in 3 Banks
S & F of HEPA Filter with efficiency of 99.99% down to 0.3 microns of size 600 mm x 600 mm x 150 mm (Thk) as per actual site requirement for OT area and to accommodate inside the laminar bench chamber as per approved drawing.
SITC of Aluminium laminar bench with perforated sheet cover to accommodate inside HEPA filter bank along with necessary support as per standard of minium 6 ft X 8 ft dimension for OT Area as per approved drawing.
Supply and fixing of acoustic lining of supply air duct and plenumn with 25 mm thick resin bonded glass wool having density of 32 kg/m³, with 25 mm X 25 mm GI section of 1.25 mm thick, at 600 mm centre to centre covered with Reinforced Plastic tissue paper and 0.5 mm thick perforated aluminum sheet fixed to inside surface of ducts with cadmium plated nuts, bolts, stick pins, CPRX compound etc. complete as required and as per specifications.
Supply & fixing of underdeck insulation with 50mm thick TF quality Expanded polysterene slab.
Supplying and fixing of following thickness duly laminated aluminum foil of mat finish closed cell Nitrile rubber (Class “O”) insulation on existing duct after applying suitable adhesive for Nitrile rubber. The joints shall be sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required.
DUCT THERMAL INSULATION FOR DUCT FOR NON-AC ZONE
Supplying & fixing of Thermal insulation of the duct running in non AC Zone with 75 mm thick expanded polysterene finishised with with 12 mm thick sand cement plaster. Make - Beardsell/ Astha/ Thermowell
SITC of Inline fan for OT exhaust as per actual site requirement for successful performance. [ Make - As per Approved Make]
a) Exhaust Fan of Capacity - 650 CFM 10 mm WC
b) Exhaust Fan of Capacity - 840 CFM 10 mm WC
c) Exhaust Fan of Capacity - 920 CFM 10 mm WC
DRAIN PIPE FOR CHILLED WATER SYSTEM WITH INSULATION:-
SITC of Drain piping with GI B Class pipes with fittings duly insulated with 25 MM THICK "TF" qulaity (16 Kg/CuM density) EPS section, Vapour barrier and covered with sand, cement and plaster with GI chicken wire mesh along with necessary quantities of supports, flanges, bends, elbows, fittings, nutbolts,gaskets etc:
a) 50 mm NB
b) 40 mm NB
ELECTRICAL PANEL [ Make - As per Approved Make]
VFD Bypass AHU Starter Panel Wall Mounted Microprocessor Based Electrical Panel Board consisting of 1 No Main Incoming MCB (ABB/Siemens/L&T), 2 nos Outgoing feeder consisting of MCB (ABB/Siemens/L&T) along with Ammeter (AE), ON/OFF indicating Lamps (siemens)and DOL Starter (ABB/Siemens/L&T) and other control units as per requirement / necessity for starting / running / control the system all complete as per direction & ssatisfaction of EIC & as per relevent IS. Panel should have provision of interconnect / inlocking arrangement with VAV, Fire Damper, Fire Panel etc. An Autocadd generated drawing with Bill of Materials must be approved from EIC before starting the construction of panel. (CPRI Approved Panel Manufacturer)
VFD Bypass AHU Starter Panel for OT Area Wall Mounted Microprocessor Based Electrical Panel Board consisting of 1 No Main Incoming MCB (ABB/Siemens/L&T), 2 nos Outgoing feeder consisting of MCB (ABB/Siemens/L&T) along with Ammeter (AE), ON/OFF indicating Lamps (siemens)and DOL Starter (ABB/Siemens/L&T) for Air Handling Units FOR OT AREA, 1 no. MCB for Exhaust Fans and 1 no. MCB for Heater and other control units as per requirement / necessity for starting / running / control the system all complete as per direction & ssatisfaction of EIC & as per relevent IS. An Autocadd generated drawing with Bill of Materials must be approved from EIC before starting the construction of panel. (CPRI Approved Panel Manufacturer)
Supplying of one number 1.1 KV Grade XLPE insulated and PVC sheathed aluminium conductor cable ( Armoured ) Al cable conforming to IS: 7098 / 1988 with its latest amendment of following size.
4Core 150 Sq. mm
4Core 16 Sq. mm
4Core 10 Sq. mm
4Core 4 Sq. mm
Supplying of one number 1.1 KV Grade XLPE insulated Cu cable
7 core 2.5 sq.mm
4 core 2.5 sq.mm
3 core 2.5 sq.mm
Laying of cable as below, through existing cable tray/surface on wall as per direction of the EIC.
4Core 150 Sq. mm
4Core 16 Sq. mm
4Core 10 Sq. mm
4Core 4 Sq. mm
7 core 2.5 sq.mm
3/4 core 2.5 sq.mm
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below including finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials
4Core 150 Sq. mm Al-Armoured cable
4Core 16 Sq. mm Al-Armoured cable
4Core 10 Sq. mm Al-Armoured cable
4Core 4 Sq. mm Al-Armoured cable
7 core 2.5 sq.mm Cu cable
3/4 core 2.5 sq.mm Cu cable
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall as per GS
Connecting the equipments to earth busbar including S & F Solid GI (Hot Dip) wire of size as below as per GS
Supply & Fixing of perforated GI cable tray with perforation not more than 17.5% suspended from ceiling incl. S&F GI connector, 6mm dia MS suspender, bolts & nuts, steel fastener etc. as required of the following size. Incl. Al painting of MS support With S&F 25x25x3mm angle iron support
Supply & Fixing of perforated GI cable tray bend with perforation not more than 17.5% suspended from ceiling with two nos. suspenders & 25x25x3mm angle iron for supporting the cross member incl. S&F GI connector, 6mm dia MS suspender, bolts & nuts, steel fastener etc. as required of the following size. Incl. Al painting of MS support.
Supply & Fixing of perforated GI cable tray tee as per GS
Supply & Fixing of perforated GI cable tray cross member as per GS
Supply & Fixing of perforated GI cable tray reducer as per GS
a. 250mm thick brick work with 1st class bricks in cement morter (1:4) in ground floor.
b. Plastering of surface upto 20 mm thick by cement morter (1:4) in ground floor.
c. Neat cement punning about 1.5 mm thick in wall - do - - do - window, sillis, floor, drain etc.
e) Dismantling all types of plain cement concrete / brick works, stacking serviceable materials at site & removing rubbish as directed by EIC within a lead of 75 Mtr. (upto 150 mm thick)
f) Ordinary cement concrete (mix. 1:2:4) with graded stone chips (20 mm size) excluding shuttering & reinforcement, if any, in ground floor as per relevant IS code (Pakur variety)
g) Cleaning all the sites (where civil dismantling & new work done) & restoring the area (for Public Use) & remove all the rubbish outside hospital (KMCH) premises as per direction of EIC.
M.S. structural works with C-Channel, Equal Angle confirming to relevent IS, as per design, drawing & direction of Engineer-in-charge complete including cutting requisite shape and size, fabrication including metal arc welding conforming to relevent IS: 816-1956 & IS: 9595 using electrodes of approved make and brand conforming to IS: 814- 1957, haulage, hoisting and erection all complete. The rate includes the cost of all M.S. structural materials, all consumables such as electrodes, gas and hire charges of all tools and plants and labour requrired for execution and all incidental charges (such as electricity, labour insurance) etc. complete. Payment to be made on the basis of calculated weight of structural members as specified in relevant IS code in finished work. The rates are considered for a height of erection 8m. / 3rd floor / roof level from the ground / floor level. (PWD Bldg Schedule)
Terms and condition
The Agency must procure the materials from the Manufacturer / OEM or from their authorised sales channel so that the standard warranty / support of the Manufacturer / OEM becomes applicable to the products to be delivered and installed by them.
Documents that authenticates such procurement from the Manufacturer / OEM or from their authorized sales channel and standard warranty / support should be sent from the e-mail of the Manufacturer / OEM / authorized sales channel to the e-mail of Engineer-in-Charge and hard copy of it to be submitted during execution, of work/submission of bill.
If any refurbished material is supplied and installed, penal action will be taken as per existing rules
Defect Liability period 1 (One) Year
(Rates should be Quoted inclusive of all taxes & duities and L.W.C. @ 1% as applicable)
SUVIDHA ENGINEERS INDIA PVT. LTD
BLUE STAR LIMITED
EVAC ENGINEERING PROJECTS PVT. LTD
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .